• 제목/요약/키워드: Discharge voltage characteristics

검색결과 965건 처리시간 0.02초

개방형 유전체 구조를 갖는 교류형 플라즈마 디스플레이의 방전 특성 연구 (Study on Discharge Characteristics in AC Plasma Display Panel with Open Dielectric Structure)

  • 조병권
    • 한국전기전자재료학회논문지
    • /
    • 제25권11호
    • /
    • pp.906-909
    • /
    • 2012
  • The address discharge characteristics of a open dielectric structure compared with the conventional panel structure are investigated by measuring the discharge firing voltage. The open dielectric structure could easily produce the discharge between the scan and the sustain electrodes by erasing the dielectric layer between two electrodes. Due to the changes in the discharge firing characteristics of the open dielectric structure between the two sustain electrodes, the conventional reset waveform including the address waveform needs to be modified. The modified driving waveform suitable for the open dielectric structure is proposed and examined in AC PDP.

권선형기기 On-line 부분방전 측정용 6-6kV급 Ceramic Coupler의 신뢰성 평가 (Evaluation of Reliability on the 6.6kV Class Ceramic Coupler for On-line Partial Discharge Measurement in Winding Machines)

  • 강동식;김용주;윤영호
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제54권2호
    • /
    • pp.69-75
    • /
    • 2005
  • In order to improve the reliability of high voltage rotating machines and mold transformers, it is necessary to understand the breakdown mechanism and life assessment of the high voltage winding parts. Especially the on-line PD test provides the ability to monitor effects, such as slot discharge, internal discharge, and end-winding discharge without interrupting the electrical machines, this method has been proven the major testing technology. Capacitive couplers have been the most widely used sensors for the on-line partial discharge detection in rotating machines nowadays. This paper deals with the electrical characteristics and long-term reliability of a ceramic coupler(CC), which can be easily mounted into high voltage input terminal part, has been developed and tested to continuously measure PD activity during operating condition. This paper presents electrical characteristics (dielectric loss angle, capacitance, PD inception level, breakdown voltage, and frequency response bandwidth) and long-term life test result of the developed 6.6 kV class on-line ceramic coupling sensor. It was found that this sensor had good electrical characteristics to detect PD activity during the operating condition with its detection frequency band is between several and several tens MHz. Also, the voltage life of the 6.6kV class ceramic coupler was calculated over 60 years.

인버터 구동형 저압 유동전동기의 절연특성 분석 (Analysis of Insulation Characteristics of Low-Voltage Induction Motors Fed by Pulse-Controlled Inverters)

  • 박도영
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2000년도 전력전자학술대회 논문집
    • /
    • pp.195-198
    • /
    • 2000
  • In this paper the insulation characteristics test results of 25 low-voltage induction motors($3\phi$, 5HP, 380V) are presented. Five different types of insulation techniques are applied to 25 motors. The maximum partial discharge (PD) magnitude ($\textrm{Q}_{m}$) discharge inception voltage (DIV) dissipation factor tip-up ($\Delta$tan$\delta$) and rate of change in AC current($\Delta$I) are measured by PD and AC current tests. Also the insulation breakdown tests by high voltage pulse are performed and the corresponding breakdown voltage are obtained.

  • PDF

선대 평판형 플라즈마장치의 코로나 방전 및 오존발생 특성에 미치는 바이어스된 3전극의 영향 (Effect of the Biased Third Electrode of a Wire-Plate Type Plasma Reactor on Corona Discharge and Ozone Generation Characteristics)

  • 정재승;문재덕
    • 전기학회논문지
    • /
    • 제57권4호
    • /
    • pp.648-652
    • /
    • 2008
  • Corona discharge and ozone generation characteristics of a wire-plate plasma reactor, with a biased third electrode, have been investigated with an emphasis on the role of the bias voltage and frequency applied on the third electrode. It was found that the wire-plate plasma reactor, with the biased third electrode, had a switching characteristic on its I-V characteristics for negative and positive discharges, which is very different from that of a conventional wire-plate plasma reactor without the third electrode. As a result, the corona discharge and ozone generation characteristics of the proposed plasma reactor could be controlled by adjusting the bias voltage and frequency of the third electrode. The corona onset and breakdown voltages, and ozone generation and yield, were increased compared with those of without the third electrode. These, however, reveal the effectiveness of the biased third electrode.

와이어컷 방전에 의한 합금공구강과 초경합금의 가공특성 (A Study on the Characteristics of Wire-Cut Electric Discharge Machining of Alloyed Tool Steel and Tungsten Carbide)

  • 이재명;허성중;김원일
    • 한국자동차공학회논문집
    • /
    • 제4권1호
    • /
    • pp.123-133
    • /
    • 1996
  • From the experimental study of wire-cut Electric Discharge Machining of alloyed tool steel and tungsten carbide, the characteristics such as cutting speed, surface roughness has been observed and evaluated for various conditions. Cutting speed is improved as peak discharge current and wire tension become increased, and gap voltage and spark cycle decreased. Surface roughness can be better when peak discharge current and gap voltage become smaller, or spark cycle and wire tension become larger. Secondary cut is recommended to obtain high precision and good quality.

  • PDF

저압 방전등 교류 접등 특성의 이론적 예측 (Theoretical Prediction of AC Characteristics of Low Pressure Lamps)

  • 지철근;장우진;여인선;이진우
    • 대한전기학회논문지
    • /
    • 제38권6호
    • /
    • pp.470-476
    • /
    • 1989
  • In order to develop a mathematical model which can predict the operating voltage and current of a discharge lamp, the properties and the physical phenomena of a low pressure gas discharge are investigated. Fluorescent lamp which uses a low pressure mercury-argon gas discharge is used in the model development. In a low pressure mercur-argon gas discharge, the continuity equation for each excited atom and electron, and the electron energy balance equation can predict the physical quantities of discharge. By coupling these equations and the circuit equation, the electrical characteristics of the discharge lamp can be predicted. To verify the validity of the suggested model, we calculated the voltage and current of a fluorescent lamp operating with inductor ballast for source frequency of 5KHz, 8KHz, 10KHz, and 13KHz. The results show good agreements in wave forms between the measured voltage and current, and the difference between the measured and calculated one is less than 5%.

  • PDF

Effects of Panel Temperature on the Discharge Characteristics of Micro Discharge Cells

  • Shim, Kyung-Ryeol;Park, Chung-Hoo;Lee, Ho-Jun
    • KIEE International Transactions on Electrophysics and Applications
    • /
    • 제4C권5호
    • /
    • pp.215-219
    • /
    • 2004
  • The effects of ambient temperature on the discharge characteristics of Ne-Xe based micro discharge cells for ac-PDP (plasma display panel) have been studied. In ramp voltage driving, which is generally used as a reset method of PDP, two dissimilar modes of strong and weak discharge were found. As the interval between the former sustaining discharge and ramp voltage discharge becomes greater, the probability of a strong discharge increases. This suggests that a sufficient number of priming particles is necessary for initiating weak mode (Townsend discharge). It was discovered that under higher ambient temperatures, weak discharge occurs more frequently. The discharge time lag observed in square pulse driving of single cells becomes surprisingly smaller under higher ambient temperatures for the constant gas number density condition.

A Study on the Insulation Characteristics for Stator Windings of IGBT PWM Inverter-Fed Induction Motors

  • Hwang, Don-Ha;Kang, Dong-Sik;Kim, Yong-Joo;Lim, Tae-Hoon;Bae Sung-Woo;Kim Dong-Hee;Ro Chae-Gyun
    • Journal of Power Electronics
    • /
    • 제3권3호
    • /
    • pp.159-166
    • /
    • 2003
  • The winding insulation of low-voltage induction motors in adjustable-speed drive system with voltage-fed Inverters is substantially stressed due to the uneven voltage distribution and excessive voltage stress (dv/dt), which result in the premature insulation breakdown In this paper, the detailed insulation test results of 26 low-voltage induction motors are presented. Six different types of insulation techniques are applied to 26 motors. The insulation characteristics are analyzed with partial discharge, discharge inception voltage, AC current, and dissipation factor tests Also, insulation breakdown tests by high voltage pulses are performed, and the corresponding breakdown voltages obtained.

임펄스전압에 의한 수중방전특성에 대한 연구 (The Study of Underwater Discharge Characteristics against impulse voltage)

  • 이복희;최종혁;박건춘;이봉;김회구;이강수;안창환
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2007년도 춘계학술대회 논문집
    • /
    • pp.271-273
    • /
    • 2007
  • This paper presents the experimental results of underwater discharges in 25 mm point-plane gap caused by impulse voltage. Discharge phenomena were observed by digital cameras and recorded by oscilloscope. As a result, discharge patterns in positive and negative polarity have different shapes according to applied voltage amplitudes. The positive discharge is like root but the negative discharge is similar to bush. As the voltage is increased, the discharge routs are thick and have more branches. Also the time to breakdown is inversely proportional to voltage.

  • PDF

고전압 방전을 이용한 수질분식에 관한 특성 (A Characteristics on Water Quality Analysis Used the High-Voltage Discharge)

  • 조국희;김영배;조문수
    • 조명전기설비학회논문지
    • /
    • 제18권5호
    • /
    • pp.156-161
    • /
    • 2004
  • 본 논문은 수질 오염 항목의 대표격인 대장균 제거를 위해 고전압 펄스 전원과 직류 전원을 비드(SiO$_2$, $Al_2$O$_3$, ZrO$_2$)가 없는 방전관, 비드가 있는 방전관, 그리고 수중 방전관에 사용하였다. 실험 결과에 따르면 대장균 제거 특성은 입력 전압의 비에 따라 나타났는데, 이는 입력전압이 증가할 때 방전관내의 전계영역이 같이 증가하기 때문이다. 그리고 고전압 펄스 전원을 사용했을 때 지르코니아(ZrO$_2$) 비드 방전관이 다른 방전관들보다 우수하였으며, 직류전원을 사용한 수중 방전관이 고전압 펄스를 사용한 방전관들보다 수중 대장균 제거 특성이 우수한 결과를 보였다.