• Title/Summary/Keyword: Discharge time

Search Result 2,624, Processing Time 0.032 seconds

Ignition Characteristics Analysis of Pseudospark Discharge using Fluid Method (유체법을 이용한 유사스파크 방전의 기동 특성 해석)

  • 심재학;주흥진;고광철;강형부
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1997.04a
    • /
    • pp.95-98
    • /
    • 1997
  • Theoritical predictions are given of the time dependence of charged particle densities and electric field in a pseudospark discharge. Our medel is based on a numerical solution of the continuity equation for electrons and positive ions and coupled with Poisson's equation for the electric field. From numerical results, we can identify phisical mechanisms that lead to the rapid rise in current in the onset of a pseudospark discharge.

  • PDF

Discharge Characteristics of Xe-flashlamp for Laser pumping (레이저 펌핑용 Xe-flashlamp 의 방전 특성)

  • Choi, Myeon-Sook;Oh, Chul-Han
    • Proceedings of the KIEE Conference
    • /
    • 1989.07a
    • /
    • pp.409-410
    • /
    • 1989
  • Discharge characteristics of a commercial made Xe-flashlamp have been studied for the pumping source of dye Lasers. The rise-time, FWHM, intensity and energy of pumping light pulses of the lamp were measured as functions of the serial resistor and applied voltage. The grid effects of the lamp on pre-discharge and the spectrum of light pulses also have been investigated.

  • PDF

A LIFE PREDICTION OF LDPE DEGRADATION PROCESSING USING PARAMETERS (파라미터를 이용한 LDPE 절연열화 과정의 수면예측)

  • Kim, Sung-Hong;Seo, Jang-Soo
    • Proceedings of the KIEE Conference
    • /
    • 2000.07e
    • /
    • pp.40-43
    • /
    • 2000
  • Our studies diagnose insulation degradation using the method of computer sensing system, which has the advantages of PD(partial discharge) and AE(acoustic emission) sensing system. To use advantages of these two methods can be used effectively to search for treeing location and PD in some materials. In analysis method of degradation, using statically operator such as the center of gravity (G), the gradient of the discharge distribution(C), we have analyzed for the prediction of life which we can be obtained the time, occurred of many pulse of small discharge amplitude.

  • PDF

전류변화에 따른 Over Cut에 관한 실험적 연구

  • 신근하
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 1996.10a
    • /
    • pp.58-63
    • /
    • 1996
  • A study is drawn up its result's tables and graphs by measuring tools(outside micrometer cylinder gauge and dial caliper gauge) on the difference of diameter volumes from before-discharge and after-discharge under 52 Kind's experimental condition by cupper and graphite electrode of CNC EDM. The EDM is attached with A.V.R. and memory scope for keep up accuracy and the fixed table of work piece is used in order to eliminate the noise by the internal resistance of it and forcing to eradicate the discharge liquid. It is analyzed cutting conditions to compare its wave value and pulse time.(Ton Toff) through voltage and current for decreasing working error.

  • PDF

A Basic Study on the Attachment Process of Lightning Leader to Ground (낙뢰 리더의 대지부착과정에 대한 기초적 연구)

  • Yoo, Yang-Woo;Kim, Seung-Min;Kim, You-Ha;Lee, Bok-Hee
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.28 no.10
    • /
    • pp.82-88
    • /
    • 2014
  • This paper presents the results of model tests for the attachment process of lightning leader to ground which is one of poorly understood processes of cloud-to-ground lightning discharges. In order to simulate the attachment process of lightning leader to ground, we investigated the discharge characteristics of air gap between the tip of needle-shaped electrode and the soil surface as a parameter of moisture content in soils when the positive and negative $1.2/50{\mu}s$ lightning impulse voltages are applied. The breakdown voltage and the discharge light were observed. As a result, the attachment processes of lightning leader to ground are strongly dependent on the grain size and the moisture content of soils. The time to breakdown was shortened with increasing the magnitude of incident impulse voltages. The delay time from application of the highest voltage to breakdown in sand is shortened with increasing the moisture content. The delay time from application of the voltage to breakdown in gravel varied from about $0.5{\mu}s$ to several ${\mu}s$. As the moisture content in soil increases, the breakdown voltages are decreased and the breakdown voltage versus time to breakdown curves are shifted toward the lower side. The results obtained in this work are similar to those for non-uniform air gap stressed by lightning impulse voltages.

Development of Runoff Hydrograph Model for the Derivation of Optimal Design Flood of Agricultural Hydraulic Structures(II) (농업수리구조물의 적정설계홍수량 유도를 위한 유출수문곡선 모형의 개발(II))

  • 이순혁;박명근;맹승진
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.38 no.3
    • /
    • pp.112-126
    • /
    • 1996
  • This study was conducted to develop an optimal runoff bydrograph model by comparison of the peak discharge and time to peak between observed and simulated flows derived by four different models, that is, linear time-invariant, linear time-variant, nonlinear time-invariant and nonlinear time-variant models under the conditions of heavy rainfalls with regionally uniform rainfall intensity in short durations at nine small watersheds. The results obtained through this study can be summarized as follows. 1. Parameters for four models including linear time-invariant, linear time-variant, nonlinear time-invariant and nonlinear time-variant models were calibrated using a trial and error method with rainfall and runoff data for the applied watersheds. Regression analysis among parameters, rainfall and watershed characteristics were established for both linear time-invariant and nonlinear time-invariant models. 2. Correlation coefficients of the simulated peak discharge of calibrated runoff hydrographs by using four models were shown to be a high significant to the peak of observed runoff graphs. Especially, it can be concluded that the simulated peak discharge of a linear time-variant model is approaching more closely to the observed runoff hydrograph in comparison with those of three models in the applied watersheds. 3. Correlation coefficients of the simulated time to peak of calibrated runoff hydrographs by using a linear time-variant model were shown to be a high significant to the time to peak of observed runoff hydrographs than those of the other models. 4. The peak discharge and time to peak of simulated runoff hydrogaphs by using linear time-variant model are verified to be approached more closely to those of observed runoff hydrographs than those of three models in the applied watersheds. 5. It can be generally concluded that the shape of simulated hydrograph based on a linear time-variant model is getting closer to the observed runoff hydrograph than those of three models in the applied watersheds. 6. Simulated hydrographs using the nonlinear time-variant model which is based on more closely to the theoritical background of the natural runoff process are not closer to the observed runoff hydrographs in comparison with those of three models in the applied watersheds. Consequently, it is to be desired that futher study for the nonlinear time-variant model should be continued with verification using rainfall-runoff data of the other watersheds in addition to the review of analyical techniques.

  • PDF

Gasification from Surface during Discharge and Thermal Processes in Plasma Display Panel (PDP)

  • Soh, Hyun;Lee, Sang-Moo;Kim, Young-Chai
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2004.08a
    • /
    • pp.495-498
    • /
    • 2004
  • PDP use the mixture of inert gases to generate a discharge inside display pixels. Inside of PDP, there exist highly reactive conditions in the gap between two glass panels. MgO layer and phosphor have been investigated as a function of discharge and thermal process. Impurities such as CO, $CO_2$, OH and $H_2O$ in discharge region may deteriorate the characteristics of PDP operation during life time. Change of impurity generation of various MgO and phosphor surfaces were measured by using x-ray photoelectron spectroscopy(XPS) and quadropole mass spectrometer (QMS). Carbon containing species such as C, CO and $CO_2$ were drastically increased on the surfaces during discharge and thermal treatment. Carbon impurities on the MgO and phosphor are the dominant factor for their instability.

  • PDF

Effect of auxiliary electrode on the discharge characteristics in AC PDP with long sustain-gap

  • Park, Sang-Dae;Lee, Seung-Hun;Shin, Nam-Hoon;Lee, Kyo-Sung;Park, Sung-Yun;Kim, Sang-Ho;Shin, Bhum-Jae;Choi, Kyung-Cheol
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2004.08a
    • /
    • pp.109-112
    • /
    • 2004
  • The effect of auxiliary electrode on the discharge characteristics in AC PDP with long sustain-gap was investigated. The auxiliary electrode was placed between scan and common electrode. When the pulse was applied to the auxiliary electrode during sustain period, the luminance of Ne + 13%Xe gas-mixture discharge increased and the discharge current decreased. The auxiliary pulse plays a role of improving electron excitation efficiency. When the auxiliary pulse was applied during address period, the address discharge time lag of Ne + 13%Xe gas-mixture could be reduced remarkably.

  • PDF

Measurement of a Threshold Initiation Carrier Density for a Reduction in Gas Breakdown Voltage

  • Park, Hyunho;Kim, Youngmin
    • Journal of Electrical Engineering and Technology
    • /
    • v.13 no.6
    • /
    • pp.2421-2424
    • /
    • 2018
  • A direct measurement of an initiation carrier injection for a low voltage discharge is presented. A self-sustained pulsed discharge is utilized to characterize electrical responses of a glow discharge for varying amounts of injected initiation carriers. It is clearly demonstrated that the initiation carrier injection affects the ignition time and the breakdown voltage of the primary discharge. An abrupt reduction in the breakdown voltage for a $300{\mu}m$ gap pin-plate discharge is observed when a threshold carrier density of $3{\times}10^{11}cm^{-3}$ is injected and the breakdown voltage continues to decrease to 250 V with increasing the initiation carrier injection beyond the threshold density.

Effect of MgO Deposition Condition on the Discharge Characteristic of AC-PDP (AC-PDP에서 MgO 증착조건에 따른 패널특성 연구)

  • Jeong, Joo-Young;Cho, Sung-Yong;Lee, Don-Kyu;Lee, Hae-June;Lee, Ho-Jun;Park, Chung-Hoo
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.58 no.8
    • /
    • pp.1566-1571
    • /
    • 2009
  • The discharge electrodes in ac PDP are coated with dielectric layer, and transparent MgO thin films are deposited on the dielectric layer. The main role of the MgO thin films in ac PDP is to protect the dielectric layer from sputtering by ion bombardment in the glow-discharge plasma. An additional important role of the MgO thin film is the high secondary electron emission coefficient which leads the low firing voltage and low cost of the PDP. In this paper, we investigated the relations of the crystal orientation about deposition thickness, deposition rate, temperature of substrate, and distance between the MgO tablet and the substrate. Additionally, we investigated the discharge characteristics of the AC PDP using nano-powder MgO tablet