• Title/Summary/Keyword: Discharge procedure

Search Result 225, Processing Time 0.021 seconds

Partial Discharge Process and Characteristics of Oil-Paper Insulation under Pulsating DC Voltage

  • Bao, Lianwei;Li, Jian;Zhang, Jing;Jiang, Tianyan;Li, Xudong
    • Journal of Electrical Engineering and Technology
    • /
    • v.11 no.2
    • /
    • pp.436-444
    • /
    • 2016
  • Oil-paper insulation of valve-side windings in converter transformers withstand electrical stresses combining with AC, DC and strong harmonic components. This paper presents the physical mechanisms and experimental researches on partial discharge (PD) of oil-paper insulation at pulsating DC voltage. Theoretical analysis showed that the phase-resolved distributions of PDs generated from different insulated models varied as the increase of the applied voltages following a certain rule. Four artificial insulation defect models were designed to generate PD signals at pulsating DC voltages. Theoretical statements and experimental results show that the PD pulses first appear at the maximum value of the applied pulsating DC voltage, and the resolved PD phase distribution became wider as the applied voltage increased. The PD phase-resolved distributions generated from the different discharge models are also different in the phase-resolved distributions and development progress. It implies that the theoretical analysis is suitable for interpretation of PD at pulsating DC voltage.

A Study on the Optimum Design of Air-Conditioning Duct with Multiple Diffusers (다수의 취출구를 갖는 A/C덕트의 최적설계에 관한 연구)

  • 김민호;이대훈
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.10 no.5
    • /
    • pp.98-106
    • /
    • 2002
  • The airflow characteristics of an air-conditioning duct with multiple diffusers were investigated through one-dimensional analysis, CFD simulation and experimental measurement. One-dimensional program based on Bernoulli's equation and minor loss equations was developed in order to evaluate the air distribution rate at each diffuser. In CFD simulation, three-dimensional flow characteristics inside air-conditioning duct were computed for incompressible viscous flow, adopting the RNG k-$\xi$turbulence model. Also, in an effort to equalize the discharge flow rate at each outlet, the optimization procedure has been performed to obtain the optimum diffuser area. In this process, square of difference between maximum discharge rate and minimum discharge rate is used as an object function. Diffuser area and discharge velocity are established as constraints. After optimization process, determined design variables are applied again in CFD simulation and experiment to validate the optimized result by one-dimensional program. Comparison with the experimental data of airflow rate distribution showed that the developed program seems to be acceptable and can be useful design tool for an automotive air-conditioning duct in an initial design stage.

Development of Analytical Techniques for Human Serum and Urine by Using Glow Discharge (글로우 방전을 이용한 혈청과 뇨의 분석기술 개발)

  • Lee, Sang Chun;Choi, Kyung-Soo;Son, Eun-Ho;Sim, Young-Jin
    • Analytical Science and Technology
    • /
    • v.11 no.3
    • /
    • pp.167-173
    • /
    • 1998
  • An electrothermal vaporization-hollow cathode glow discharge-atomic emission spectrometer(ETV-HCGD-AES) has been developed for detecting heavy metals in human serum and urine samples. Fisrt of all, we designed a glow discharge cell for atomic emission spectrometry and its analytical performance was studied with the standard reference materials(SRMs) purchased from the NIST. Practically, the ETV-HCGD-AES demonstrated better instrumental sensitivity and selectivity for detecting Hg and Pb in the SRMs, serum and urine, than ICP-OES since the ETV-HCGD-AES was not required the complicate sample digestion procedure, which improved sample transportation efficiency.

  • PDF

Tidal behavior changes in Mangyeong reservoir area with permitting sea-water intrusion through the sluice gate (만경수역 해수 유통시 조석환경변화 고찰)

  • Kwun, Soon-Kuk;Park, Yeong-Wook
    • Proceedings of the Korean Society of Agricultural Engineers Conference
    • /
    • 2001.10a
    • /
    • pp.21-24
    • /
    • 2001
  • As one of the phil-environmental alternative plan of Saemankeum project, gradual development is recommended. The procedure of the Saemankeum project start with the completion of 32 km long sea-dikes which contains two discharge gates until the year 2004. Second step is pre-development of Mangyoung area permitting temporary intrusion of sea water, i.e. tides, by the opening of discharge gate until the environmental evaluation on the water quality of this area secures permanent meet to government's water quality standard. Therefore this study is to predict the future condition of this tidal flat with the point of view tidal environments, salt, water quality, soil mechanics, etc. of Mangyoung area when the sea water still passed in the inland reservoir through the discharge gate.

  • PDF

Characteristics of Agricultural Water Rights in national Rivers (국가하천의 농어수리권 특성)

  • 김진수
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.42 no.3
    • /
    • pp.56-65
    • /
    • 2000
  • The characteristics of agricultural water rights were examined for the national rivers in Korea. We suggest that the national rivers could according to the actual management organization of agricultural water right be categorized into national management rivers KOWACO(Korea Agrcultural & Rural Infrastructure COrporation) management river. The agricultural water right between the national and KOWACO management rivers have different characteristics for irrigation period permit procedure water charge and type of water right. The agricultural water rights are granted in the natural discharge less than reference droughty discharge for most of national management rivers and in the developed discharge for the KOWACO and KARICO management rivers. The current system of agricultural water rights is complicated inconsistent and incapable of coping with unusual drought and therefore it needs to be improved.

  • PDF

Analysis of Partial Discharge Signal Using Wavelet Transform (웨이브렛 변환을 이용한 부분방전 신호의 분석)

  • Lee, Hyun-Dong;Kim, Chung-Nyun;Park, Kwang-Seo;Lee, Kwang-Sik;Lee, Dong-In
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.49 no.11
    • /
    • pp.616-621
    • /
    • 2000
  • This paper deals with the multiresolution analysis of wavelet transform for partial discharge(PD). Test arrangement is based on the needle-plane electrode system and applied AC high voltage. The measured PD signal was decomposed into "approximations" and "details". The approximation are the high scale, low-frequency components of the PD signal. The details are the low-scale, high frequency components. The decomposition process are iterated to 3 level, with successive approximation being decomposed in turn, so that PD signal is broken down into many lower-resolution components. Through the procedure of signal wavelet transform, signal noise extraction and signal reconstruction, the signal is analyzed to determine the magnitude of PD.

  • PDF

Comparison of the effects of target-controlled infusion-remifentanil/midazolam and manual fentanyl/midazolam administration on patient parameters in dental procedures

  • Lobb, Doug;Ameli, Nazila;Ortiz, Silvia;Lai, Hollis
    • Journal of Dental Anesthesia and Pain Medicine
    • /
    • v.22 no.2
    • /
    • pp.117-128
    • /
    • 2022
  • Background: Moderate sedation is an integral part of dental care delivery. Target-controlled infusion (TCI) has the potential to improve patient safety and outcome. We compared the effects of using TCI to administer remifentanil/manual bolus midazolam with manual bolus fentanyl/midazolam administration on patient safety parameters, drug administration times, and patient recovery times. Methods: In this retrospective chart review, records of patients who underwent moderate intravenous sedation over 12 months in a private dental clinic were assessed. Patient indicators (pre-, intra-, and post-procedure noninvasive systolic and diastolic blood pressure, respiration, and heart rate) were compared using independent t-test analysis. Patient recovery time, procedure length, and midazolam dosage required were also compared between the two groups. Results: Eighty-five patient charts were included in the final analysis: 47 received TCI-remifentanil/midazolam sedation, and 38 received manual fentanyl/midazolam sedation. Among the physiological parameters, diastolic blood pressure showed slightly higher changes in the fentanyl group (P = 0.049), respiratory rate changes showed higher changes in the fentanyl group (P = 0.032), and the average EtCO2 was slightly higher in the remifentanil group (P = 0.041). There was no significant difference in the minimum SpO2 levels and average procedure length between the fentanyl and remifentanil TCI pump groups (P > 0.05). However, a significant difference was observed in the time required for discharge from the chair (P = 0.048), indicating that patients who received remifentanil required less time for discharge from the chair than those who received fentanyl. The dosage of midazolam used in the fentanyl group was 0.487 mg more than that in the remifentanil group; however, the difference was not significant (P > 0.05). Conclusion: The combination of TCI administered remifentanil combined with manual administered midazolam has the potential to shorten the recovery time and reduce respiration rate changes when compared to manual administration of fentanyl/midazolam. This is possibly due to either the lower midazolam dosage required with TCI remifentanil administration or achieving a stable, steady-state low dose remifentanil concentration for the duration of the procedure.

Unit Mass Estimation and Analysis from Textile Spinning/Weaving Manufacturing Facility Nearby Nakdong River Basin (낙동강 수계에서 제사방적제조 업체에 대한 공정별 원단위산정 및 분석)

  • Lee, Hongshin;Son, Gontae;Gu, Jungeun;Konboonraksa T.;Lee, Hongtae;Lee, Seunghwan
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.22 no.5
    • /
    • pp.541-550
    • /
    • 2008
  • In this investigative study, the unit mass discharge for the major water quality parameters such as flowrate, SS, BOD, CODmn, CODcr, TN, TP from textile spinning/weaving industry nearby Nakdong river basin was estimated. To represent the respective industries, three companies from hundreds of textile spinning/weaving industries located in Nakdong river basin was carefully selected based on its manufacturing goods, flowrate and location for the estimation of unit mass discharge based on unit operation and process. There was a drastic decrease of unit mass discharge estimation between influents and effluents of water quality parameters, which represents the removal capacity of wastewater treatment plant. With the advent of new regulation on the imposed payment proportional to the total amount of pollutants discharge into the water body, the concept of cleaner production technology should be employed in the unit operation/process in wastewater treatment plant as well as textile manufacturing procedure to minimize the levy on the pollutants discharge. Unit mass discharge estimations of unit process (estimated in this study) in major water quality parameters (SS, BOD, COD, TN and TP) based on land were similar to those of composite process (estimated by National Institute of Environmental Research). But the unit mass discharge estimations of unit process in BOD and CODmn based on total sale were much higher than those of composite one while in SS, TN and TP similar to each other. For the detailed estimation of the imposed payment, unit mass estimation based on unit process should be further emphasized.

A Comparative Study on the Selection and Discharge of Arbitrator(s) among Korea, China and America (한.중.미 중재인의 선정 및 기피에 관한 비교연구)

  • Shin, Koon-Jae
    • Journal of Arbitration Studies
    • /
    • v.21 no.1
    • /
    • pp.183-213
    • /
    • 2011
  • China and North America have been South Korea's biggest trading partner long time. As the volume of trade has been increasing, the disputes between Korean companies and Chinese Companies and between Korean companies and North American Companies have been increasing. If these disputes are settled by Arbitration, the parties appoint arbitrators who are empowered to proceed the arbitration procedure and have a power to render an arbitral award. Accordingly, it is very important for the parties to select who is an arbitrators in Arbitration. But if the parties doubt their arbitrator(s)'s fairness and independency, they can discharge them in accordance to law and arbitration institute's rules. In comparison with arbitrator system for way of selection and discharge among Korea, China and North America, some differences are found. First, if parties fail to appoint co-arbitrators or the presiding arbitrator by a mutual agreement, the court has the right to appoint them or him in Korea and North America whereas the Chairman of CIETAC choose him in China. Second, the authority to decide whether arbitrator is discharged owing to his fairness and independency, depends on arbitration institute and court in Korea and North American whereas it depends on the Chairman of CIETAC only.

  • PDF

FE Analysis of Plasma Discharge and Sheath Characterization in Dry Etching Reactor

  • Yu, Gwang Jun;Kim, Young Sun;Lee, Dong Yoon;Park, Jae Jun;Lee, Se Hee;Park, Il Han
    • Journal of Electrical Engineering and Technology
    • /
    • v.9 no.1
    • /
    • pp.307-312
    • /
    • 2014
  • We present a full finite element analysis for plasma discharge in etching process of semiconductor circuit. The charge transport equations of hydrodynamic diffusion-drift model and the electric field equation were numerically solved in a fully coupled system by using a standard finite element procedure for transient analysis. The proposed method was applied to a real plasma reactor in order to characterize the plasma sheath that is closely related to the yield of the etching process. Throughout the plasma discharge analysis, the base electrode of reactor was tested and modified for improving the uniformity around the wafer edge. The experiment and numerical results were examined along with SEM data of etching quality. The feasibility and usefulness of the proposed method was shown by both numerical and experimental results.