• Title/Summary/Keyword: Discharge pressure

Search Result 1,467, Processing Time 0.021 seconds

Displacement Control of Pneumatic Actuator Equipped with PLC and Proximity Sensors (PLC와 근접센서를 이용한 공압 실린더의 변위제어)

  • Kim, Gun-Hoi;So, Jung-Duck
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.17 no.2
    • /
    • pp.90-96
    • /
    • 2008
  • A pneumatic system was proposed to evaluate displacement accuracy of the pneumatic actuator without external load and to analyze capability of integration of the proposed valve system. The proposed pneumatic system consisted of a combination of pneumatic valves, two proximity sensors, and a programmable logic controller(PLC). The position controller is based on the PLC controller connected with the proximity sensors. Displacement accuracy of the pneumatic cylinder stroke was tested by varying air pressures of the supply and discharge-side and strokes of the pneumatic cylinder. The displacement accuracy of the pneumatic cylinder stroke increased as the supply and discharge side of air pressure increased at the stroke length of 133mm. Also the displacement accuracy increased as the stroke length increased with a fixed supply and discharge side of air pressure of the pneumatic cylinder as 3.5 and $4.5kg/cm^2$, respectively. The most accurate displacement of the pneumatic cylinder(i.e., standard deviation of 0.01 mm) was obtained at the supply and discharge side of air pressure of 4.0 and $5.0kg/cm^2$, respectively, and strokes of 170 and 190 mm among arbitrarily selected supply and discharge side air pressures and strokes.

Analysis on DC Glow Discharge Properties of Ar Gas at the Atmosphere Pressure (대기압 Ar 가스의 직류 글로우 방전 특성분석)

  • So, Soon-Youl
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.59 no.4
    • /
    • pp.417-422
    • /
    • 2010
  • Atmosphere Plasma of Gas Discharge (APGD) has been used in plasma sources for material processing such as etching, deposition, surface modification and so on due to having no thermal damages. The APGD researches on AC source with high frequency have been mainly processed. However, DC APGD studies have been not. In order to understand APGD further, it is necessary to study on fundamental properties of DC APGD. In this paper, we developed a one-dimensional fluid simulation model with capacitively coupled plasma chamber at the atmosphere pressure (760 [Torr]). Nine kinds of Ar discharge particles such as electron (e), positive ions ($Ar^+$, $Ar_2^+$) and neutral particles ($Ar_m^*$, $Ar_r^*$, $Ar_h^*$, $Ar_2^*$(1), $Ar_2^*$(3) and Ar gas) are considered in the computation. The simulation was worked at the current range of 1~15 [mA]. The characteristics of voltage-current were calculated and the structure of Joule heating were discussed. The spatial distributions of Ar DC APGD and the mechanism of power consumption were also investigated.

Trichel Pulse in Negative DC Corona discharge and Its Electromagnetic Radiations

  • Zhang, Yu;Liu, Li-Juan;Miao, Jin-Song;Peng, Zu-Lin;Ouyang, Ji-Ting
    • Journal of Electrical Engineering and Technology
    • /
    • v.10 no.3
    • /
    • pp.1174-1180
    • /
    • 2015
  • We investigate in this paper the radiated electromagnetic waves together with the discharge characteristics of Trichel pulse of negative DC corona discharge in air in pin-to-plate and wire-to-plate configurations. The feature of the current pulse and the frequency spectrum of the electromagnetic radiations were measured under various pressures and gas gaps. The results show that the repetition frequency and the amplitude of Trichel pulse current depend on the discharge conditions, but the rising time of the pulse relates only to the radius of needle or wire and keeps constant even if the other conditions (including the discharge current, the gas gap and the gas pressure) change. There exists the characterized spectrum of electromagnetic waves from negative corona discharge in Trichel pulse regime. These characterized radiations do not change their frequency at a given cathode geometry even if the averaged current, the gas gap or the air pressure changes, but the amplitude of radiations changes accordingly. The characterized electromagnetic radiations from Trichel pulse corona relate to the formation or the rising edge of current pulse. It confirms that the characterized radiations from Trichel pulse supply information of discharge system and provide a potential method for detecting charged targets.

Factors influencing on the discharge coefficients of sonic nozzle (소닉노즐의 유출계수에 영향을 미치는 인자에 관한 연구)

  • Yu, Seong-Yeon;Lee, Sang-Yun;Park, Gyeong-Am
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.20 no.12
    • /
    • pp.4027-4035
    • /
    • 1996
  • Accuracy of gas flow measurements using sonic nozzle and factors which influence on the discharge coefficients of sonic nozzle are investigated with high pressure gas flow standard measurement system. The gas flow measurement system comprises two compressors, storage tank, temperature control loop, sonic nozzle test section, weighing tank, gyroscopic scale and data acquisition system. The experiments are performed at various nozzle throat diameter and inlet pressure. Overall uncertainty of discharge coefficients is estimated to less than .+-.0.2% and most of experimental data fall into this range. Dependence of discharge coefficients on the Reynolds number is good agreement with those suggested in ISO document. The influence of swirl on the discharge coefficients becomes greater as the nozzle throat diameter is enlarged. The discharge coefficient of conical nozzle shows about 4.5% lower discharge coefficients than those of toroidal nozzle, but variation trend with Reynolds number is very similar each other and reproducibility of data is very good.

Design and Optimization of Glow Discharge Atomic Absorption Spectrometry System (글로우방전 원자흡수시스템의 구성 및 최적화에 관한 연구)

  • Kim, Hyo Jin;Jang, Hye Jin;Lee, Gae Ho;Jo, Jeong Hwan
    • Journal of the Korean Chemical Society
    • /
    • v.38 no.3
    • /
    • pp.214-220
    • /
    • 1994
  • A glow discharge atomic absorption system for the direct analysis of conducting solid samples has been designed and constructed. An arrestor made of machinable ceramic which is a main component for confining the discharge between cathode and anode is modified to have a better stability in discharge. Discharge voltage or current, shape of arrestor, pressure, and gas flow rate can be controlled by an ADC/DAC board with a personal computer. The effect of discharge parameters such as discharge voltage, pressure, and gas flow rate on the sample loss rate, absorbance, and the surface morphology of sample by SEM has been studied to find optimum discharge conditions.

  • PDF

Electrical and Optical Characteristics of Flat Fluorescent Lamp for LCD Back-lighting (LCD 후면 광원용 FEL의 전기적 및 광학적 특성)

  • 김명녕;권순석
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.7 no.4
    • /
    • pp.725-729
    • /
    • 2003
  • In this paper, a mercury-free flat discharge lamp with opposite electrode structure, a couple of phosphor layer and discharge vessel has been studied for LCD back-lighting. When the drive voltage conditions were set properly, a uniform discharge generates over entires emitting surface. The firing voltage was increased with increasing the discharge gas pressure. It was considered that this tendency was resulted from the decrease of mean free paths due to the increase of discharge gas pressure. The maximum luminance of 2700[cd/m2] was obtained in the green emitting FFL.

The Effect of Distance between $90^{\circ}$Elbow close to Upstream Face of Orifice Plate and Orifice Plate on Discharge Coefficient (오리피스 전단에 인접한 $90^{\circ}$엘보와 오리피스간의 거리가 유출계수에 미치는 영향)

  • Yoon Joon-yong;Sung Nak-won
    • Proceedings of the KSME Conference
    • /
    • 2002.08a
    • /
    • pp.357-360
    • /
    • 2002
  • The effect of distance between ninety degree elbow close to upstream face of orifice plate and orifice plate on discharge coefficient was investigated. The distributions of discharge coefficient and differential pressure caused by elbow and short upstream straight length were examined and modified discharge coefficient was introduced. The results presented in this study could be useful when orifice plate is installed under the condition of simple flow disturbance element and short upstream straight length.

  • PDF

Light-Output Characteristics of a Low-Pressure Mercury-Argon Discharge Lamp in a Transverse Magnetic Field (횡자계 인가시 저압 수은-아르곤 방전등의 광출력특성)

  • 여인선;박왕렬
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 1989.10a
    • /
    • pp.9-12
    • /
    • 1989
  • ABSTRACT -- Recently, a method of magnetically-enhanced discharge columns is considered to increase the luminous efficacy of discharge lamps, which is based upon the face that the diffusion motion of charged particles in the discharge column strongly depends on the applied magnetic fields. This study investigates the effect of applied transverse magnetic fields on the light output of low-pressure Hg-Ar discharge. As a result, it is found that the electric field in the positive column increases according to the applied megnetic field, which causes an increase in the total light output. And this effect is much more pronounced upon the spectral line originating form the higher levels.

  • PDF

A Study on Growth Mechanism of Organic Thin Films by the Plasma Polymerization (플라즈마동합법에 의한 유기피막의 성장기정에 관한 연구)

  • 이덕철;한상옥;박구범
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.36 no.1
    • /
    • pp.29-35
    • /
    • 1987
  • TPolystyrene thin films are prepared by glow discharge of sytrene monomer vapor th establish the growth mechanism of organic thin films by the plasma polymerization. As the discharge parameters, discharge current(5mA-20mA), frequency (10kHz-50kHz, 13.56MHz), gaspressure (0.2torr-1.5torr), and discharge time(2min-12min)are adopted. Plasma-polymerized filmsof styrene vapor are identified as polystyrene by IR spectra. The thickness of plasma-polymerized films increases with gas pressure, frequency and discharge current in the region of the low frequency and below the allowed gas pressure where the polymerization occurs. It is suggested that the growth mechanism can be explained by ionic reaction in d.c. and low frequency region, and by radical reaction in high frequency region.

Application of Air Lift Pump for Sludge Discharger (공기 양정(air lift) 펌프를 응용한 슬러지 배출장치에 대한 연구)

  • Ahn Kab-Hwan;Park Young-Seek
    • Journal of Environmental Science International
    • /
    • v.13 no.10
    • /
    • pp.929-938
    • /
    • 2004
  • Sludge discharger applied the principle of the air lift pump was investigated experimentally for the different design( diameter of discharge pipe, diameter and height of the inside and outside wall) and operating parameters(air flow rate, water level). And it was conducted that performance comparison about sludge discharger and conventional air lift pump. The result indicated that discharged liquid were increased with the increase of air flow rate and water level and decrease distance between inside and outside wall. The discharge pressure was increased with an increase of air flow rate and a decrease of the diameter of the discharge pipe, for both the sludge discharger and the airlift pump. The discharge pressures of the sludge discharger were 3-6 times higher than those of the air lift pump.