• Title/Summary/Keyword: Discharge pressure

Search Result 1,467, Processing Time 0.028 seconds

Monte Carlo Simulation of Thermionic Low Pressure Discharge Plasma (저압 열전자 방전 플라즈마의 Monte Carlo 시뮬레이션)

  • Koh, Wook Hee
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.61 no.12
    • /
    • pp.1880-1885
    • /
    • 2012
  • Nonlinear dynamical behaviors in thermionic low pressure discharge are investigated using a particle-in-cell(PIC) simulation. An electrostatic PIC code is developed to model the plasma discharge system including the kinetic effects. The elastic collision, excitation collision, ionization collision, and electron-ion recombination collision are considered in this code. The generated electrons and ions are traced to analyze physical characteristics of the plasma. The simulation results show that the nonlinear oscillation structures are observed for cold plasma in the system and the similar structures are observed for warm plasma with a shift in values of the bifurcation parameter. The detailed oscillation process can be subdivided into three distinct mode; anode-glow, temperature-limited, and double-layer modes.

Observation of Discharge Mode Transient from Townsend to Glow at Breakdown of Helium Atmospheric Pressure Dielectric Barrier Discharge (헬륨 대기압 유전체 격벽 방전기의 타운젠트-글로우 방전 모드 전이 연구)

  • Bae, Byeongjun;Kim, Nam-Kyun;Yoon, Sung-Young;Shin, Jun-Seop;Kim, Gon-Ho
    • Journal of the Semiconductor & Display Technology
    • /
    • v.15 no.2
    • /
    • pp.26-31
    • /
    • 2016
  • The Townsend to glow discharge mode transition was investigated in the dielectric barrier discharge (DBD) helium plasma source which was powered by 20 kHz / $4.5 kV_{rms}$ high voltage at atmospheric pressure. The spatial profile of the electric field strength at each modes was measured by using the intensity ratio method of two helium emission lines (667.8 nm ($3^1D{\rightarrow}2^1P$) and 728.1 nm ($3^1S{\rightarrow}2^1P$)) and the Stark effect. ICCD images were analyzed with consideration for the electric field property. The Townsend discharge (TD) mode at the initial stage of breakdown has the light emission region located in the vicinity of the anode. The electric field of the light emitting region is close to the applied field in the system. Immediately, the light emitting region moves to the cathode and the discharge transits to the glow discharge (GD) mode. This mode transition can be understood with the ionization wave propagation. The electric field of the emitting region of GD near cathode is higher than that of TD near anode because of the cathode fall formation. This observation may apply to designing a DBD process system and to analysis of the process treatment results.

The Strain of Flexible Ring Type Valve used for Refrigeration Compressor (냉동압축기용(冷凍壓縮機用) 환상형토출(環狀型吐出)밸브의 변형(變形))

  • Jeong, J.W.;Jo, K.O.
    • The Magazine of the Society of Air-Conditioning and Refrigerating Engineers of Korea
    • /
    • v.17 no.2
    • /
    • pp.150-158
    • /
    • 1988
  • On a refrigeration compressor, damage of a discharge valve is one of the annoying troubles for an engineer. Small size compressors, having ring plate type discharge valve are recently used. Therefore, it is very important for engineers to measure and analyze strains of discharge valve. The purpose of this study is to obtain the basic data of the strain of the flexible ring valve. Measurements were performed by the strain gauge bonded on the surface of the flexible ring valve. Stress and strain of the valve were calculated by the method of uniformly loaded circular plates with a central hole. The results obtained are as follows; (1) the strain of flexible ring discharge valve in refrigeration compressor was influenced by tension and compression strain simultaneously. (2) for a given discharge pressure, the tangential and radial strains was increased with increasing discharge pressure. (3) the valve of radial strain was larger than that of tangential strain.

  • PDF

An Empirical Study on the Standard Re-establishment of Water Discharge Performance for the Fire Engine Pump (소방차 펌프의 방수성능 기준 재정립을 위한 실증적 연구)

  • Min, Se-Hong;Kwon, Yong-Joon
    • Fire Science and Engineering
    • /
    • v.26 no.5
    • /
    • pp.85-91
    • /
    • 2012
  • This paper analyzed firefighting officers' use situations such as the use time, maximum working pressure, hose diameter, etc. of fire pumps at fire sites and carried out various performance tests by pressures, hose diameters and quantities of fire pumps based on its results because the waterproof performance criterion for a fire pump installed in a fire engine is different from the operation situations at the site and is not clearly prescribed. As a result of site survey, the site uses a higher pressure than the standard water discharge pressure (0.85 MPa) or the high-pressure water discharge pressure (1.4 MPa) prescribed by the approval Standard of the fire pump performance on fire truck. In addition, as a result of pump performance test, the discharged water flow rate, water discharge pressure, etc. was measured to be very different from the currently prescribed the approval standard depending on the hose diameter and firefighting nozzle, so the result of this study proposes a new standard.

Glow Discharge as Detector for Gas Chromatography (글로우방전을 이용한 가스크로마토그라프 검출기의 개발)

  • 김효진;박일영;장성기;김박광;박만기
    • YAKHAK HOEJI
    • /
    • v.37 no.1
    • /
    • pp.76-83
    • /
    • 1993
  • The changes in discharge current, emission and/or oscillation frequency of the electric oscillation of a glow discharge are the potential sensitive measure of the concentration of an impurity in the argon plasma supporting gas. A single jet enhanced glow discharge has been interfaced with the gas chromatograph via 1/8" O.D. tube with a heating pad to study the changes in discharge current. To investigate the optimum operating conditions of the glow discharge system as detector for gas chromatography, pressure, gas flow rate, discharge current, distance between the anode and the cathode have been studied.

  • PDF

Characteristics of the closed microhollow cathode discharge for DC Plasma Display Panels

  • Park, Hae-Il;Noh, Joo-Hyon;Ryu, Byung-Gil;Baik, Hong-Koo
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2000.01a
    • /
    • pp.105-106
    • /
    • 2000
  • The positive slope of the current-voltage characteristic at pressure up to 850 torr was obtained using the closed microhollow cathode without the individual and/or distributed ballast. This indicates that the stable parallel operation of the discharge was also achieved using the closed microhollow cathode. The parallel operation makes it possible to manufacture de plasma displays with high pressure, small discharge current, and long lifetime.

  • PDF

Characteristics of Laser-Guided DC Discharge by Nd: YAG Laser at Low Pressure

  • Lee, Dong-Hoon;Kim, Hee-Je
    • Journal of Electrical Engineering and information Science
    • /
    • v.3 no.3
    • /
    • pp.316-321
    • /
    • 1998
  • In recent years, concern has been raised about the technique of controlling electrical breakdown by using laser in many fields. Especially, laser has attracted much attention in the Electro-Discharge Macining(EDM) because of its many merits. Therefore, this research has been performed to obtain fundamental data relevant to discharge processing by using a pulsed Nd:YAG laser. The experiments of laser-guided dc discharge by laser radiation have been carried out at low air pressure ranging from 0.2 to 20 torr. The minimum laser-guided dc discharge voltage V\ulcorner at the given pressures P and distances D between an anode and a cathode was measured. It is found that the minimum laser-guided dc discharge voltage is much lower than the natural discharge voltage V\ulcorner\ulcorner, and the values of V\ulcorner and V\ulcorner as a function of P.D has a similar tendency. The laser output energy Eout decreases with input pulse duration tp increasing, and the more the value of tp increases, the higher that of V\ulcorner is obtained because the number of photons during the discharge time N decreases with t\ulcorner increasing. There is the time lag frequently when the discharge by laser radiation is misguided under the condition of the applied voltage less than V_G.min.

  • PDF

Effect of discharge power and pressure in deposition of diamond thin films by MWPECVD (MWPECVD법에 의한 Diamond박막 성장에 있어서 방전전력과 압력의 영향)

  • Rho, Se-Yeol;Choi, Jaog-Kyu;Park, Sang-Hyun;Park, Jae-Yun;Koh, Hee-Seog
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1992.11a
    • /
    • pp.132-135
    • /
    • 1992
  • Diamond thin films by MWPECVD in methane-hydrogen mixed gas were studied, with emphasis on the investigation of the effect of discharge power and pressure. As a result, the growth rate of diamond thin films was affected by discharge power and the surface morphology of diamond thin films was affected by pressure. The growth rate of diamond films was about 1.65 ${\mu}m$/hr under the condition of MW power: 900W, pressure: 60torr, $H_2$ flow rate: 60sccm, $CH_4$ concentration: 1 % and deposition time: 5hr. The deposited diamond films were identified by SEM, XRD and Raman spectrophotometer.

  • PDF

Advanced Microwave Plasma Technology for Liquid Treatment

  • Toyoda, Hirotaka;Takahashi, T.;Takada, N.
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2014.02a
    • /
    • pp.121.1-121.1
    • /
    • 2014
  • Recently, much attention has been given to plasma production under liquid and its applications [1]. However, most of plasma production techniques reported so far utilize high voltage dc, ac, rf or microwave power [2], where damage to discharge electrodes and small discharge volume are remained issues. As an alternative of plasma production method under liquid, we have proposed pulsed microwave excited plasma using slot antenna, where damage to the slot electrode can be minimized and plasma volume can be increased. We have also reported improvement of treatment efficiency with use of reduced-pressure condition during the discharge [3]. To realize low pressure conditions in liquid, various alternative technique can be considered. One possible technique is simultaneous injection of microwave power and ultrasonic wave. Ultrasonic wave induces pressure fluctuation with the wave propagation and is so far used for cavitation production in the water. We propose utilization of reduced pressure induced by ultrasonic cavitation for improvement of the plasma production. Correlation between the plasma production and the ultrasonic power will be discussed.

  • PDF

A study on the discharge characteristics of liquid nitrogen at atmospheric pressure (대기압하에서 액체질소(LN2)방전특성에 관한 연구)

  • 이영근;주재현;김상구;이광식;이동인
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 1993.10a
    • /
    • pp.58-62
    • /
    • 1993
  • This paper shows the discharge characteristics of liquid nitrogen under plane to plane electrode, needle to plance electrode, inserting teflon insulator in plane to plane electrode at atmospheric pressure. The main experimental device of this paper is cryostat. The important results obtained from this study are sa follows. Breakdown voltage of LN2 under N-P electrode is higher than that of under P-P electrode at atmospheric pressure. Breakdown duration time is longer with increase of electode gap under the P-P, N-P electrodes. The formation of bubbles by evaporation is observed in spite of non-applying source at atmospheric pressure and the creation of corona confirmed. Breakdown voltage and breakdown duration time are in proportion to increase of diameter in case of inserting teflon insulator. Partial discharge characteristics of thickness 0.5[mm] is that 채굼 voltage of teflon insulator rose with increase of diameter in each [pps].

  • PDF