The Strain of Flexible Ring Type Valve used for Refrigeration Compressor

냉동압축기용(冷凍壓縮機用) 환상형토출(環狀型吐出)밸브의 변형(變形)

  • 정진웅 (농수산물유통공사 종합식품연구원) ;
  • 조권옥 (부산수산대학 냉동공학과)
  • Published : 1988.04.01

Abstract

On a refrigeration compressor, damage of a discharge valve is one of the annoying troubles for an engineer. Small size compressors, having ring plate type discharge valve are recently used. Therefore, it is very important for engineers to measure and analyze strains of discharge valve. The purpose of this study is to obtain the basic data of the strain of the flexible ring valve. Measurements were performed by the strain gauge bonded on the surface of the flexible ring valve. Stress and strain of the valve were calculated by the method of uniformly loaded circular plates with a central hole. The results obtained are as follows; (1) the strain of flexible ring discharge valve in refrigeration compressor was influenced by tension and compression strain simultaneously. (2) for a given discharge pressure, the tangential and radial strains was increased with increasing discharge pressure. (3) the valve of radial strain was larger than that of tangential strain.

Keywords