• Title/Summary/Keyword: Discharge method

Search Result 3,039, Processing Time 0.029 seconds

A Comparative Study of Maternal Satisfaction with the Mode of Newborn Care Education - Videotaped vs. Verbal - (신생아실의 퇴원교육 방법에 따른 산모의 만족도 비교 연구)

  • Joo, Hyun Sil;Seo, Young Joon;Lee, Kyu Sik;Kim, Chun Bae
    • Quality Improvement in Health Care
    • /
    • v.8 no.2
    • /
    • pp.160-171
    • /
    • 2001
  • Background : This study was conducted to compare the level of satisfaction between mothers who were educated on the care of newborns by video-taped method and those by verbal one before discharge. Methods : Fifty-two mother (verbal method group) from a free standing OB & GY hospital in Wonju City and forty-seven mothers (videotaped method group) from the OB & GY section of Wonju Christian Hospital(WCH) were selected for a study sample. The knowledge and understanding of newborn care and the degree of maternal satisfaction were assessed after the education by self-administered questionnaires. The opinions of the 11 nurses of WCH who were involved in the education were also collected by a questionnaire. Results : With respect of the level of understanding and satisfaction with the discharge education on newborn care, there is no significant difference between the videotaped educated group and verbal educated one. The correlation analysis of the video education group revealed a strong correlation between the score of understanding and satisfaction with the discharge preparation(r=0.409, p=0.01), and between the satisfaction scores for discharge preparation and discharge education(r=0.844, p=0.001). As for the verbal education group, the score of understanding also correlated significantly with both the score of satisfaction with the discharge education(r=0.272, p=0.001) and the discharge preparation(r=.680, p=0.001). Conclusions : This study showed that the discharge education to mothers regarding newborn care by a videotaped method does not improve the understanding or satisfaction of the mothers. However, the response to the mode of discharge education varies by the characteristics of the mothers. In conclusion, the characteristics of the mother should be considered in order to improve the understanding and knowledge of newborn care when the mode discharge education is chosen.

  • PDF

The Noise Removal Methode of Partial Discharge Signal (부분방전 신호 검출 시 노이즈 제거방법)

  • Choi, Mun-Gyu;Cha, Hanju
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.65 no.8
    • /
    • pp.1436-1441
    • /
    • 2016
  • Currently, partial discharge diagnosis in the field of prevention applied technology and diagnostic equipment is a possible strong limit to remove the noise generated by external or internal I still have one unreliable diagnosis. This technology is the noise removal from signal the time lag analysis algorithms technique is applied by a fundamental. Increasing the reliability in terms of technology spectrum frequence of analysis method for by applying the acquisition through the position of the frequency content and sources of traffic lights partial discharge of the acquisition of signal analysis to judge whether a way diagnosis the environment of the scene, and conditions. Partial discharge signal and make the discharge while building blocks were found through the Analysis. Spectrum frequence of Analysis and wide discharge part, to be more precise, in line with the various functions, including the analysis technique band. Diagnosis and comes up with advanced technology that can detect the presence of a position. This method is portable single device developed for maintenance and mobility and ease and convenience of getting caught by discharge of the pattern analysis and position detection method suitable for a new diagnosis will suggest.

An Application of the On Line Partial Discharge Measurement Method in Transformer (온라인 변압기 부분방전 측정기법 적용)

  • Kweon, Dong-Jin
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.50 no.8
    • /
    • pp.394-400
    • /
    • 2001
  • This paper describes an application of the on line partial discharge measurement method in operating transformer. In the operating transformer, the partial discharge signal may be superimposed by radio intereference voltage(RIV) and pulse shaped noise signals generated by external corona. The partial discharge quantity showed about 3,800pC due to very high sinusoidal interferences at the measuring impedance terminal of the transformer bushing tap. In order to reject these noises, this paper applied RIV filter, band-pass filters and noise gating method. The resulting measuring sensitivity was improved from 3,800pC to 160pC.

  • PDF

The Development of HFPD System for Mibile-loading Vehicles (차량탑재형 HFPD의 개발)

  • Kim, Deok-Geun;Im, Jang-Seop;Yeo, In-Seon
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2001.05c
    • /
    • pp.33-37
    • /
    • 2001
  • Recently, the HFPD measurement testing is widely used in partial discharge measurement of HV machines because HFPD measurement testing receives less influence of external noise and has a merit of good sensitivity. Also HFPD testing is able to offer the judgement standard of degradation level of HV machine and can detect discharge signals in live-line. Therefore it is very useful method compare to previous conventional PD testing method and effective diagnosis method in power transformer that requires live-line diagnosis. But partial discharges have very complex characteristics of discharge pattern so it is required continuous research to development of precise analysis method. In recent, the study of partial discharge is carrying out discover of initial defect of power equipment through condition diagnosis and system development of degradation diagnosis using HFPD(High Frequency Partial Discharge) detection. In this study, simulated transformer is manufactured and HFPD occurred from transformer is measured with broad band antenna in real time, the degradation grade of transformer is analyzed through produced patterns in simulated transformer according to applied voltages.

  • PDF

A Study of Electrical and Optical Method of Safety Standards for diagnosis of Power Facility using UV-IR Camera (UV-IR 카메라를 이용한 전력설비 진단을 위한 전기 및 광학적 안전 기준 설정 연구)

  • Kim, Young-Seok;Kim, Chong-Min;Choi, Myeong-Il;Bang, Sun-Bae;Shong, Kil-Mok;Kwag, Dong-Soon
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.27 no.4
    • /
    • pp.54-61
    • /
    • 2013
  • UV-IR camera is being used for predictive maintenance of high voltage equipment together with measurement of temperature on localized heat and corona discharge. This paper was suggested the judgement method that is the discharge count, UV image pattern and discharge matching rate to apply the UV-IR camera on power facility. The discharge count method is counted by UV image pixel value. the UV image pattern method is determined by the UV image shape using neural network algorithm method, separated by Sunflower, Jellyfish, Ameba. The UV discharge matching is compare the breakdown the UV image size and measuring UV image size according to distance.

Derivation of the Synthetic Unit Hydrograph at Ungaged Small Watershed (미계측 소하천수계의 합성단위도 유도)

  • 안상진;이억한
    • Water for future
    • /
    • v.19 no.2
    • /
    • pp.157-166
    • /
    • 1986
  • The objective of this study was to determine the best representative synthetic unit hydrograph that is applicable to ungaged small watershed. A typical unit hydrograph was established with the actual data from a small watershed. Four currently well-known methods for analyzing ungaged small watershed, including Snyder's, Clark's S.C.S. and Nash methods, were evaluated with the data from the same small watershed. The following observations were noted from the analysis of four methods. The Snyder's method yielded the similar peak discharge value as the typical unit hydrograph. With co-ordinates of three discharge values, i.e. 25%, 50% and 75% of peak discharge, were not adequate for deriving a typical unit hydrograph in ungaged small watershed. With Clark's method there shall be some way of obtaining the exact base length of time area diagram and isochrone of each reach of the stream. With Nash method peak discharge and base flow time are affected by the storage constant and gamma function argument; therefore, for deriving a more reliable and workable unit hydrograph one needs to select for the better estimation of storage constant and gamma function argument. In S.C.S. method peak discharge is directly related to the watershed area and inversely related to the time of peak diacharge. Therefore area with faster peak discharge yielded the higer peak discharge value. Although the peak discharge value obtained frome the S.C.S. method higher than the value obtained from the unit hydrograph developed from the actual data, this method contains a number of advantageous factors. The peak discharge value and the time of peak discharge can be claculated easity from the morphological characteristics of the watershed, and in S.C.S method co-ordinates of the unit hydrograph can be calculated easily from that of the dimensionless unit hydrograph. When the four currently used methods were evaluated with a typical unit hydrograph obtained from the actual data, the S.C.S method was show to be the best method in deriving a synthetic unit hydrograph for ungaged small watershed.

  • PDF

A Study of Minimum Ignition Energy Measurement of Explosive Powders Caused by Electrostatic Discharges (정전기 방전시의 분체류의 최소착화에너지 측정에 관한 연구)

  • 이동훈;목연수;최재욱;신중현;류상민;조일건;정준채
    • Proceedings of the Korean Institute of Industrial Safety Conference
    • /
    • 1997.05a
    • /
    • pp.67-75
    • /
    • 1997
  • To establish testing method for ignition energy of explosive powders caused by electrostatic discharge, one testing method using a very small quantity of tested powders ( Frima ) was proposed, and the influence of discharge - limiting resistance connected in series into a capacitive discharge circuit on ignition energies of explosive powders was investigated using, as tested powders. As a result the minimum ignition energy was 9 mJ when discharge-limiting resistance was 300 k$\Omega$. The reason for the dependence of ignition energy on discharge-limiting resistance was thought to the difference in the type of electrostatic discharge, such as arc or glow discharge, from the observation of discharging wave forms.

  • PDF

A Novel Battery Charge/Discharge System with Zero Voltage Discharge Function (영전압 방전 기능을 갖는 새로운 배터리 충방전시스템)

  • Nguyen, Quang Manh;Choi, Woojin
    • Proceedings of the KIPE Conference
    • /
    • 2013.07a
    • /
    • pp.169-170
    • /
    • 2013
  • One important test for formation and grading of the lithium-ion battery is to confirm the performance of the battery while discharging battery down to zero volts. In this paper, a novel charge/discharge converter with zero-voltage discharge function is proposed. The proposed converter is able to discharge the battery until the voltage reaches to zero volts. The phase-shifted full bridge method is used to charge the battery and the current-fed push-pull method with bidirectional switches is used for the discharge. The ZVS turn-on is achieved in the charge operation and the ZVS turn-off in the discharge operation. The performance of the system is verified by the experiments using lithium-ion batteries.

  • PDF

A Study on the Prediction of Discharge by Estimating Optimum Parameter of Mean Velocity Equation (평균유속공식의 최적매개변수 산정에 의한 유량예측에 관한 연구)

  • Choo, Tai Ho;Chae, Soo Kwon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.13 no.11
    • /
    • pp.5578-5586
    • /
    • 2012
  • The accurate estimation of discharge is very essential as the important factor of river design for the utilization and flood control, hydraulic construction design. The present discharge production is using the stage-discharge relationship curve in the river. The rating curve uses the method by predicting the discharge based on regression analysis using the measured stage and discharge data in a flood season. The method is comparatively convenient and has especially advantages in that it can predict the discharge having the difficulty of observation in a flood season. However, this method has basically room for improvement because the method only uses the relationship between stage and discharge, and doesn't reflect the hydraulic parameters such as hydraulic radius, energy slope, roughness, topography, etc.. Therefore, in this study, discharge was predicted using the convenient calculation method with empirical parameters of the Manning and Chezy equations, which were proposed by Choo et at (2011) in KSCE as a new methodology for estimating discharge in open channel. The proposed method can conveniently estimate empirical parameters in both of Manning and Chezy equations and the discharge is estimated in the open channels. There are proved by using data measured in meandering lab. channel and India canal and the accuracies show about determination coefficient 0.8. Accordingly, this method will be used in actual field if this study is continuously conducted.

An Evaluation of River Discharge Estimates in a Junction with Backwater effect using Interpolated Hydraulic Performance Graph (HPG로 산정한 합류부 배수영향 구간의 유량 평가)

  • Kim, Ji-Sung;Kim, Won
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.38 no.6
    • /
    • pp.831-838
    • /
    • 2018
  • This paper presents a method to estimate the flow discharge in a backwater affected river junction. First, unsteady HEC-RAS model was simulated and calibrated using 2 recent real flood and then HPG (Hydraulic Performance Graph) was created by plotting the relationship between upstream and downstream stages and discharge in the reach and performing kriging interpolation. During a flood, the discharge through the reach can be estimated based on the stages at its ends and the developed HPG. These discharge data were in good agreement with the automatic discharge measurements such as ADVM. This study could provide an economical and practical method for estimating discharge in a junction with a high hysteresis of stage-discharge relationships.