• Title/Summary/Keyword: Discharge loading

Search Result 171, Processing Time 0.024 seconds

Effect of Rise Time of a Pulse Bias Voltage on Atmospheric Plasma Generation (대기압 플라즈마 발생시 인가전압의 상승시간에 따른 영향)

  • Kim, Jae-Hyeok;Jin, Sang-Il;Kim, Young-Min
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.57 no.7
    • /
    • pp.1218-1222
    • /
    • 2008
  • We investigate the effect of rise time of a pulse bias voltage on atmospheric plasma generation. With the faster rise time of the pulse bias, the glow discharge appears to be more uniformly generated along the electrodes. I-V measurement confirms that higher loading power can be obtained using the faster rise time. A new understanding for atmospheric plasma generation at a micro-gap electrode is suggested.

Plasma display panels; problems and their analysis via computer simulations

  • Nagorny, V.P.;Khudik, V.N.;Drallos, P.J.;Shvydky, A.
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2005.07a
    • /
    • pp.155-160
    • /
    • 2005
  • Computer simulations of a pdp discharges provide unique information necessary for their analysis, unavailable otherwise. Statistical instability of the ramp discharge and the role of exoemission, nature of striations during sustain discharge, physical mechanism responsible for the propagation of the cathode ionization wave, and line loading effects are just a few examples when simulations can be successfully used.

  • PDF

Impacts of Nitrate in Base Flow Discharge on Surface Water Quality (질산성 질소 기저유출이 지표수 수질에 미치는 영향)

  • Kim, Geonha;Lee, Hosik
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.29 no.1B
    • /
    • pp.105-109
    • /
    • 2009
  • It is a well known fact that baseflow discharge of rainfall runoff impacts on water quality of surface water significantly. In this paper, impacts of nitrate discharged as base flow on stream water quality were studied by using a software, PULSE from USGS to calculate monthly ground water discharge from hydrograph. We used water quality and flow rate data for Ghapcehon2 site in Daejeon city for year 2005 as well as ground water quality data in the watershed acquired from government agencies. Agricultural and forestry land use are dominant for upstream of Ghapcheon2 in the watershed. Base flow contributes about 85~95% of stream flows during spring and fall while 25~38% of stream flow was induced by base flow during summer and winter. Monthly nitrate loading discharged as base flow for Ghapcheon2 was estimated by using averaged nitrate concentration of groundwater in the watershed. Nitrate loading induced by base flow at Ghapcheon2 was estimated as 5.4 ton of $NO_{3}{^-}-N/km^{2}$, which is about 60% of nitrate loading of surface water, 9.2 ton of $NO_{3}{^-}-N/km^{2}$. Seasonal variation of nitrate concentration of base flow was estimated by dividing monthly nitrate loading by monthly base flow discharge. Nitrate concentration of groundwater was increasing from rainy season. From this study, it can be understood that ground water quality monitoring is important for the proper manage of surface water quality.

Non-Point Source Pollutions of the Youngsan River Basins I - The Method of Land-Use Types and Rainfall - (영산강 수계의 비점오염원에 관한 연구 I - 토지이용 및 강우를 중심으로 -)

  • Cha, Jin Myeong;Shin, Sung Euy;Cha, Gyu Suk
    • Journal of Environmental Impact Assessment
    • /
    • v.8 no.1
    • /
    • pp.41-49
    • /
    • 1999
  • This study was carried out to estimate the runoff loading characteristics of the non-point source pollutions in the Youngsan river basins by the method of land-use types and rainfall. The lysimeter test, rainfall and stream flowmeter measurement were performed to develop the pollutant loading unit discharged from the non-point sources. As the non-point sources, the unit pollutant discharge rates were different from the land-use types such as paddy field, upland, forest, housing site and others. The pollutant loading units classified by land-use types in the Youngsan river basins are as follows: The total BOD loading rate is 15.3 ton/day and the housing site is discharged 50.6%, the total T-N loading rate is 6.0 ton/day and the paddy field and upland is discharged 77.6%, and the total T-P loading rate is 0.39 ton/day and the paddy field and upland is discharged 81.2%. The pollutant loadings by rainfall in the Youngsan river basins are about 7,425 ton/year of BOD, 324 ton/year of T-N and 118 ton/year of T-P, respectively.

  • PDF

Estimation for Watershed pollutant loading with SWMM (SWMM 모형을 이용한 유역의 오염부하량 산정)

  • 전지홍;윤춘경
    • Proceedings of the Korean Society of Agricultural Engineers Conference
    • /
    • 1999.10c
    • /
    • pp.689-694
    • /
    • 1999
  • This study estimated average yearly watershed pollutant loading by using SWMM(Storm Water Management Model) which is one of the nonpoint source quality models. Two sites were measured discharge and water quality at dry period and wet period. The rainfall data is used from 1989 to 1998 . During a decade, the average year watershed pollutant loading, which is SS, BOD5 , TN, TP, were 2.39E+06kg, 0.92E +05kg, 2.53E+05kg, 2.66E+04kg respectively. During dry period, SS, BOD5 TN, TP loadings were 1.89E+05kg, 1.7E+05kg, 1.04E+05kg, 1.11E+04kg, and during wet period 1.89E+05kg, 1.17E+05kg, 1.04E+05kg, 1.11E+04kg respectively so wet period loading are more than dry day loadings.

  • PDF

Electrochemical Performances of Lithium-air Cell with Carbon Materials

  • Park, C.K.;Park, S.B.;Lee, S.Y.;Lee, H.;Jang, H.;Cho, W.I.
    • Bulletin of the Korean Chemical Society
    • /
    • v.31 no.11
    • /
    • pp.3221-3224
    • /
    • 2010
  • This study investigates the requirements of lithium-air cathodes, which directly influence discharge capacity. The cathodes of Li-air cell are made by using five different carbon materials, such as Ketjen black EC600JD, Super P, Ketjen black EC300JD, Denka black, and Ensaco 250G. The Ketjen black EC600JD provides discharge capacity of 2600 mAh/g per carbon weight, while that of Ensaco 250G shows only 579 mAh/g. To figure out the differences of discharge capacity from carbon materials, their surface area and pore volume are analyzed. These are found out to be the critical factors in determining discharge capacity. Furthermore, carbon loading on Ni foam and amounts of electrolyte are significant factors that affect discharge capacity. In order to investigate catalyst effect, electrolytic manganese dioxide (EMD) is incorporated and delivered 4307 mAh/g per carbon weight. This infers that EMD facilitates to break $O_2$ interactions and leads to enhance discharge capacity.

A Study on Discharge Capacity of Vertical Drain Considering with In-situ Soil Condition (원지반조건을 고려한 연직배수재의 통수능에 관한 연구)

  • Park, Min-Chul;Kim, Eun-Chul;Lee, Song
    • Journal of the Korean Geosynthetics Society
    • /
    • v.11 no.1
    • /
    • pp.47-56
    • /
    • 2012
  • Discharge capacity of PBD is sensitive in proportion to thickness and ground condition, and drainage of PBD declines due to disturbance effect in surrounding ground by mandrel used for vertical drainage setting and setting machines and type. Also, deviation of discharge capacity gets larger according to ground condition, construction condition and soil properties. But cause and analysis of those problems like reduced discharge of capacity and delayed dissipation of pore water pressure for discharge capacity is lack. Thus, in this text, ground improvement and discharge capacity is investigated by implementing composite discharge capacity test for analysis of an effect factor of PBD discharge capacity with in-situ ground condition. After fixing the vertical drain on a cylindrical cylinder, put churned sample into the cylinder. After in-situ ground and reclamation of ground are dredged, load following the loading step of 30, 70 and 120kPa using a pressure device. Result of the test, The discharge capacity was SM>ML>CL>CL(dredged soil) in situ condition and more fine-grained content, the amount of discharge was greater.

An Estimation of the Amount of Ship's Ballast Water to be Discharged at Korean Major Ports (국내 주요항만에서의 선박평형수 배출량 추정)

  • Choi, Hark-Sun;Kim, Han-Soo;Lee, Seung-Guk
    • Journal of the Korean Society for Marine Environment & Energy
    • /
    • v.12 no.4
    • /
    • pp.284-288
    • /
    • 2009
  • The International Convention for the Control and Management of Ships Ballast Water & Sediments was adopted by consensus at a diplomatic conference of IMO at 2004. To prepare the Ballast Water Management Convention, fundamental technologies such as treatment system, type approval, risk assessment and various technical informations for formulation of the regulation for national strategy shall be developed. The information item of voyage and discharge of ship's ballast water are gathered by visiting vessel and agent at port. Using the 97 results by ships type characteristic analysis on the relation between loading/unloading and discharge/uptake of ballast water, the amounts of discharge/uptake of ballast water at each port and all of country in Korea are predicted. Hence, It is apparent that the uptake of ballast water is predicted to about 70 million ton in total of Busan, Incheon, Kwangyang and Ulsan ports at 2006 which is over 3 times than discharges.

  • PDF

Partial Discharge Measuring System of Mold Transformer (몰드변압기의 부분방전 측정 시스템)

  • Kang, Dong-Sik;Sun, Jong-Ho;Lim, Tae-Hoon;Hwang, Don-Ha;Kim, Yong-Joo;Kweon, Dong-Jin;Oeu, Soo-Young
    • Proceedings of the KIEE Conference
    • /
    • 2003.07c
    • /
    • pp.1891-1893
    • /
    • 2003
  • In order to development of diagnosis system for mold transformer, partial discharge measurement technique is recommended the best effective method for the evaluation of insulation condition. However, this technique was not applied to mold transformer yet. The purpose of this paper is to describe the method of partial discharge measurement for mold transformer. As we reviewed on-line test technique, sensor, transducer of pulse signal processing, set-up of test circuit for loading back device and now testing.

  • PDF

Development of Loading Machine of Culture Medium for Oyster Mushroom Production - Investigation of Physical Properties and Element Design of System - (느타리버섯 재배용 배지 입상 장치 개발(1) - 배지 물성 조사 및 장치요소 설계 -)

  • Lee, Kyung-Jin;Lim, Hak-Kyu;Kim, Tae-Han
    • Journal of Biosystems Engineering
    • /
    • v.34 no.4
    • /
    • pp.211-219
    • /
    • 2009
  • In the process of oyster mushroom production, loading work of culture medium needs the most intensive labor power and cost. Therefore, the development of culture medium loading machine causes to reduce the manpower and cost. The main objectives of this study are identify cultivating environment, physical properties of culture medium and to make an element design of culture medium loading machine. The results are summarized as follows: 1. The moisture content and density of popularly used culture medium were 70%(w.b), $26\;kg/m^3$, respectively. 2. Pressure of the blower increased as the impeller speed increased, and the opening ratio of pressure controller decreased. 3. Recommendable c1earance(${\delta}$) between an impeller plate and a blower case was 25 mm at an impeller speed of 3183 rpm 4. Discharge device of type B with a hopper and suit was better than type A with a hopper.