• Title/Summary/Keyword: Discharge load characteristics

Search Result 194, Processing Time 0.028 seconds

Characteristics of Pollutant Loadings in a Rural Watersheds (농촌유역에서의 오염부하특성)

  • Cho, Jae-Won;Kim, Jin-Soo;Oh, Kwang-Young
    • Proceedings of the Korean Society of Agricultural Engineers Conference
    • /
    • 2002.10a
    • /
    • pp.449-452
    • /
    • 2002
  • Characteristics of pollutant load during irrigation and non-irrigation periods was investigated for streamwater from a rural watershed. Water was sampled and discharge was measured at 5-days intervals at outlet of study area. The mean concentrations of TN and TP in an irrigation period are higher than in an non-irrigation period, while mean COD concentration in an irrigation period is lower than in a non-irrigation period. For increasing discharge during an irrigation period, TN concentration increase, TP concentration is nearly unchanged, and COD concentrations decreases.

  • PDF

Characteristics of Pollutant Loading from Paddy Field Area with Groundwater Irrigation (지하수 관개지역 논에서의 배출부하 특성)

  • 윤춘경;김병희;전지홍;황하선
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.44 no.5
    • /
    • pp.116-126
    • /
    • 2002
  • Discharge pattern and water quality were investigated in the drainage water from about 10 ha of groundwater-irrigated paddy field in the growing season of 2001. Total discharge quantity was about 1,117.2 mm in which about 75% was caused by management drainage due to cultural practice of paddy rice farming and the rest by rainfall runoff where total rainfall was about 515 mm. Dry-day sampling data showed wide variations in constituent concentrations with average of 26.14 mg/L, 0.37 mg/L, 3.54 mg/L at the inlet, and 43.60 mg/L, 0.34 mg/L, 3.58 mg/L at the outlet for CO $D_{cr}$ , T-P, and T-N, respectively. Wet-day sampling data demonstrated that generally CO $D_{cr}$ followed the discharge pattern and T-P was in opposite to the discharge pattern, but T-N did not show apparent pattern to the discharge. Discharge and load are in strong relationship. And based on regression equation, pollutant loads from groundwater irrigation area are estimated to be 288.34, 1.17, and 5.45 kg/ha for CO $D_{cr}$ , T-P, and T-N, respectively, which was relatively lower than the literature value from surface water irrigation area which implies that groundwater irrigation area might use less irrigation water and result in less drainage water, Therefore, total pollutant load from paddies irrigation with groundwater could be significantly lower than that with surface water. This study shows that agricultural drainage water management needs a good care of drainage outlet as well as rainfall runoff. This study was based on limited monitoring data of one year, and further monitoring and successive analysis are recommended for more generalized conclusion.

The Calculation of NPS Load per Unit Area in Orchard to the Nakdong River Basin (낙동강유역 과수재배지의 단위면적당 비점오염부하량 산정에 관한 연구)

  • Lee, Jae-Woon;Kwon, Heon-Gak;Yi, Youn-Jeong;Cheon, Se-Uk
    • Journal of Environmental Impact Assessment
    • /
    • v.22 no.6
    • /
    • pp.557-568
    • /
    • 2013
  • In this study, Calculated the nonpoint sources(NPS) load per unit area about various rainy events in vineyard of Nakdong River basin. NPS monitoring and calculation for NPS load per unit area were estimated from 'Investigation method of precipitation discharge(National Institute of Environmental Research, 2007)'. The evaluation of applicability for NPS load per unit by compared with prior research data and Total Maximum Daily Load(TMDL) data. Five target areas were each $2000m^2$, $1800m^2$, $1943m^2$, $2484m^2$, $864m^2$ and located in Gyeongsangbukdo Gyeongju, Gyeongsangbukdo Sangju, Gyeongsangnamdo Hapcheon in Korea. Since fruits were the only crop on the target area, the characteristics of stormwater discharge at survey sites could be evaluated independently. A total of 115 rainfall events in the Orchard area during five years(2008-2012) was surveyed, and 38 of them became stormwater discharge. In the Nakdong River watershed, average of event mean concentrations(EMCs) in Orchard area for biochemical oxyzen demand(BOD), Chemical oxyzen demand(COD), total nitrogen(T-N), total phosphorus(T-P) were 2.0mg/L, 10.1mg/L, 3.195mg/L, 0.578mg/L, respectively. NPS load per unit area in Orchard area showed BOD : $2.0kg/km^2{\cdot}day$, COD : $10.2kg/km^2{\cdot}day$, T-N : $3.220kg/km^2{\cdot}day$, T-P : $0.606kg/km^2{\cdot}day$.

Application of Nonlinear Dynamics and Wavelet Theory for Discharge and Water Quality Data in Youngsan River Basin (영산강 유역의 유출량 및 수질자료에 대한 비선형 동역학과 웨이블렛 이론의 적용)

  • Oh, Chang-Ryeol;Jin, Young-Hoon;Park, Sung-Chun
    • Journal of Korean Society on Water Environment
    • /
    • v.23 no.4
    • /
    • pp.551-560
    • /
    • 2007
  • The present study analyzed noise reduction and long/short-term components for discharge, TOC concentration, and TOC load data in order to understand the data characteristics better. For the purpose, wavelet transform which can reduce noise from raw data and has flexible resolution in time and frequency domain was applied and the theory of nonlinear dynamics was also used to determine the last decomposition level for wavelet transform. Wavelet function of 'db10' and the 7th level for the last decomposition of wavelet transform were applied for the all data in the present study. Also the results revealed that the energy ratios of approximation components with 187-hour periodicity decomposed from 7th level of wavelet transform were 94.71% (discharge), 99.00% (TOC concentration), and 93.84% (TOC load), respectively. In addition, the energy ratios of detail components showed the range between 1.00% and 6.17%, which were extremely small comparing to the energy ratios of approximation components, therefore, the first and second detail components might be considered as noise components included in the raw data.

Improvement and Application of Total Maximum Daily Load Management System of Korea: 1. Calculation of Total Amount of Pollutant Load in the Anyangcheon Watershed (우리나라 오염총량관리제도의 개선 및 적용: 1. 안양천 유역의 오염부하량 산정)

  • Kim, Kyung-Tae;Chung, Eun-Sung;Kim, Sang-Ug;Lee, Kil Seong;Seong, Jin-Young
    • Journal of Korean Society on Water Environment
    • /
    • v.25 no.6
    • /
    • pp.972-978
    • /
    • 2009
  • This study modifies the present total maximum daily load (TMDL) system of Ministry of Environment and applies to the Anyangcheon watershed. Hydrologic Simulation Program-FORTRAN (HSPF) model is used to simulate both runoff and non-point source pollution, simultaneously, instead of QUAL2E. The drought flow (355th daily flow) is proposed for the target water quantity since it is easier to satisfy low flow (275th daily flow) for the target water quality than drought flow. The increase of discharge is more than the increase of pollutant load except for the period under low flow. The measured unit loads for non-point source are used to consider the regional runoff characteristics. The measured water quantity and quality data are used since the ministry of environment supports only water quality. This analysis results show some reasons for the improvement of the present TMDL system of Korea.

Characteristics of Non-point Pollution Discharge on Stormwater Runoff from Lake Doam Watershed (도암호 유역의 강우시 비점오염물질 유출 특성)

  • Kwak, Sung-Jin;Bhattrai, Bal Dev;Kim, Eun-Jung;Lee, Chang-Keun;Lee, Hyeong-Jin;Heo, Woo-Myung
    • Korean Journal of Ecology and Environment
    • /
    • v.45 no.1
    • /
    • pp.62-71
    • /
    • 2012
  • Lake Doam watershed was surveyed to evaluate non-point source discharge characteristics and discharge load including several water quality parameters in Song Stream from July 2009 to July 2011. Concentrations of water pollutants were high during the rainfall period, especially, SS, TP and COD showed increasing tendencies toward cumulative water discharge but TN did not show much difference. SS, TP and COD had an initial flush effect of over 50 mm rainfall event but there was no clear tendency for rainfalls below that level. Event mean concentration (EMC) regarding the rainy and dry period showed large differences. Especially rainy season EMC (SS, TP, COD) demonstrated an increasingly high tendency. EMCs of COD, SS, TN and TP measured for twelve rain events were as high as 26.1, 866.0, 4.68 and 0.605 mg $L^{-1}$, respectively. COD, SS, TN and TP loadings from the highland agricultural region of the Song Stream watershed were 34,263, 1,250,254, 2,673 and 933 kg $yr^{-1}\;km^{-2}$, respectively, which were relatively higher than the results of other stream systems. Therefore, it is strongly recommended that long-term monitoring and non-point pollution reduction programs for the highland agricultural area to continue. Furthermore, this non-point source pollution loading research acquired from the highland agricultural area could be the base for reassessment.

The Characteristics of Exhaust Gas in Diesel Engine by Corona Discharge-EGR System (코로나 방전-EGR 조합시스템에 의한 디젤기관의 배기 가스 특성)

  • Ha, H.J.;Park, J.Y.;Jung, J.G.;Kim, S.H.;Koh, H.S.;Bae, M.H.
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2003.07b
    • /
    • pp.1115-1118
    • /
    • 2003
  • A great part of flint fuel is Hydrogen and carbon's combination. they should be generated steam and carbon gas when combine with oxygen for perfect combustion in the inside of engine, but the pollutive material especially NOx and Soot are exhausted, even though fuel is combine perfectly. In this paper the characteristics of exhaust material from diesel engine is investigated for the corona discharge-EGR hybrid plasma reactor, which combined corona discharge with EGR system. NOx is decreased in all load and applied voltage to plasma reactor. However Soot is increased as increasing EGR rate and it is decreased as increasing applied voltage.

  • PDF

Characteristics of Pollutants Concentrations at Paddy Field Areas during Irrigation Periods (관개기 광역논에서의 오염물질의 농도 특성)

  • 김진수;오승영;김규성;권순국
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.43 no.6
    • /
    • pp.163-173
    • /
    • 2001
  • This study describes the characteristics of concentrations of pollutants such as total nitrogen(T-N), total phosphorous(T-P), and chemical oxygen demand(COD) at paddy areas during 2-year irrigation periods. The most common order in average concentrations of T-P and COD is podded water > irrigation(or drainage) water > percolated water. Most of pollutants concentrations in drainage water are lower than those in irrigation water after early July due to large uptake of pollutants by rice crop and denitrification. The exponential L (load)-Q(discharge) equations for classified irrigation periods are significant at 0.001 level for irrigation and drainage waters. For drainage water, the concentrations of T-N and COD slightly decrease with discharge, while the T-P concentrations slightly increase with discharge.

  • PDF

Dynamic Analysis of a Discharge Valve for Electrodynamic Oscillating Compressor (전동형 진동식 압축기 토출밸브의 동적해석)

  • 김형진;박윤식
    • Journal of KSNVE
    • /
    • v.10 no.4
    • /
    • pp.615-622
    • /
    • 2000
  • Discharge valve mechanism for an electrodynamic-oscillating compressor is different from that of a conventional reciprocating compressor. It has a larger discharge port area, heavier valve mass and stiffer valve spring comparing with the reciprocating one. Since the motion of piston is not kinematically restricted as in conventional reciprocating compressors, the stroke of the piston can change sensitively with supplied boltage and load. Thus piston can impact with discharge valve occasionally. This work deals on dynamic analysis of discharge valve considering all of those different characteristics. Impact is considered by a spring-mass model, and the pressure fluctuation at the both sides of the valve is also included considering the discharge port area and valve spring preload. It is assumed that piston moves in the region of between top and bottom dead center not by calculating piston motion from an electrodynamic equation but by getting values through experiment. Discharge pressure fluctuation is calculated using Helmholtz modeling. Finally, dynamic model for a discharge valve is constructed. In order to validate the model analysis results, the valve motion is experimentally measured and compared with analysis.

  • PDF

Vibration Analysis of a Valve Model with Nonlinear Stiffness (비선형 강성을 고려한 밸브 모델의 진동 해석)

  • 이수일;주재만;김태식;박윤서
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 1998.04a
    • /
    • pp.143-147
    • /
    • 1998
  • In this study, nonlinear stiffness characteristics of a discharge valve in a small hermetic compressor was considered. It was approximated, with piecewise-linearity, and cubic or quintic nonlinearity by the static load-displacement experimental results. Based on the fluid-structure interaction effects and mass flow rate, the derived 1-DOF equation of motion for the valve model was analyzed. Finally, the dynamic response of the discharge valve was studied with parameters such as the ratio of the running frequency of the compressor to the linear natural frequency of the valve.

  • PDF