• Title/Summary/Keyword: Discharge criteria

Search Result 259, Processing Time 0.023 seconds

The Allocation Methods for Economical Efficiency Using an Optimized Model (최적화 모델을 이용한 경제적인 총량관리 할당기법 연구)

  • Choi, In Uk;Shin, Dong Seok;Kim, Hong Tae;Park, Jae Hong;Ahn, Ki Hong;Kim, Yong Seok
    • Journal of Korean Society on Water Environment
    • /
    • v.31 no.3
    • /
    • pp.295-303
    • /
    • 2015
  • In Korea, Total Maximum Daily Loads(TMDLs) has been enforced to restore and manage water quality in the watersheds. However, some assesment of implementation plan of TMDLs showed that the achievement of the target water quality is not related to the proper allocation loads because difference of flow duration interval. In the United States, the discharge loads are determined by water quality modeling considering standard flow conditions according to purpose. Therefore, this study tried to develop the allocation method considering economical efficiency using water quality model. For this purpose, several allocation methods being used in the management of TMDLs is investigated and develope an allocation criteria considering regional equality and uniformity. Since WARMF(Watershed Analysis Risk Management Framework) model can simulate the time varying behavior of a system and the various water quality variables, it was selected for a decision support system in this study. This model showed fairly good performance by adequately simulating observed discharge and water quality in Miho watershed. Furthermore, the scenario simulation results showed that the effect of annual average water quality improvement to remove 1kg BOD is more than 25 times, even if point pollutants treatment facility is six times more expensive to operate than non-point pollutants treatment facility.

Analysis on the Dielectric Characteristics of Gaseous Nitrogen for Developing Eco-friendly High Voltage Apparatuses (친환경 고전압 전력기기 개발을 위한 GN2의 절연특성 분석)

  • Bang, Seungmin;Lee, Onyou;Kim, Junil;Kang, Jong O;Lee, Hongseok;Ko, Taekuk;Kang, Hyoungku
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.63 no.4
    • /
    • pp.356-360
    • /
    • 2014
  • The environmental pollution caused by green-house gases such as $SF_2$ has been becoming the main issue of industrial society. As a part of these efforts, 180 countries signed the Kyoto Protocol in 1997 to cut back on their green-house gas emissions [1]. Therefore, a study on the dielectric characteristics of the $GN_2$ is important for designing a eco-friendly high voltage apparatuses. In this paper, to develop an electrically reliable, stable, and eco-friendly high voltage apparatus, the breakdown voltage and partial discharge inception voltage characteristics in $GN_2$ considering utilization factors are studied for the establishment of insulation design criteria of an high voltage apparatus. Dielectric experiments are performed by using several kinds of sphere-plane electrode systems made of stainless steel. Also, the dielectric characteristics of the $GN_2$ are analyzed by using a Finite Elements Method (FEM) according to various field utilization factors. The results are expected to be applicable to designing the high voltage apparatuses using $GN_2$ as an insulation gas.

Water Quality Characteristics Evaluation by Flow Conditions Using Load Duration Curve - in Youngbon A Watershed - (부하지속곡선을 이용한 유량 조건별 수질특성 평가 - 영본A 유역을 대상으로 -)

  • Park, Jinhwan;Kim, Kapsoon;Jung, Jaewoon;Hwang, Kyungsup;Moon, Myungjin;Ham, Sangin;Lim, Byungjin
    • Journal of Environmental Impact Assessment
    • /
    • v.22 no.4
    • /
    • pp.319-327
    • /
    • 2013
  • This study was conducted to identify runoff characteristics of pollutants using flow duration curve(FDC) and load duration curve(LDC) in Youngbon A watershed during 2009~2011. A flow rate and pollutant load in the study watershed were estimated by equation of stage-discharge and discharge-loads rating curve. From these methods, BOD, T-N, and T-P have evaluated whether water quality standards would have attained. Results showed that BOD loads of about 50% plotted above the LDC, while T-N and T-P loads of about 50% plotted below the curve. It means that BOD of about 50% have exceeded the water quality criteria, while T-N and T-P of about 50% have complied with the water quality standards. Meanwhile, BOD, TN and T-P loads plotted above the LDC of low flows, implying that they were more affected by point pollution sources than nonpoint pollution sources in the study watershed.

Electrochemical Disinfection for Ballast Water Treatment (발라스트수 처리를 위한 전기화학적 살균처리)

  • Seo, Won-Hak;Jeon, Sun-Ae;Kim, Ji-Hyun;Lee, Tae-Ho;Sang, Byoung-In
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.28 no.11
    • /
    • pp.1162-1167
    • /
    • 2006
  • The discharge of ballast water from the marine vessel without proper treatment causes the ecological disruption. Therefore, International Marine Organization(IMO) has the plan to force the proper treatment of ballast water before its discharge to open sea. To satisfy the IMO's criteria, several processes such as filtration, UV irradiation, and ozonation etc., were introduced. Since the disinfection of ballast water should be conducted within very short hydrolic retention time, electrochemical treatment can be a promissing process. The DSA(dimensional stable anode) electrode for the electrochemical treatment was prepared by thermal deposition method. The disinfection rate of microorganisms increased with the increasing current density and reaction time under low pH condition. The morphology of sterilized microorganisms was shown by SEM and Microscopy.

Chamomile Extract versus Clotrimazole Vaginal Cream in Treatment of Vulvovaginal Candidiasis: A Randomized Double-Blind Control Trial

  • Shiravani, Zahra;Poordast, Tahereh;Alamdarloo, Shaghayegh Moradi;Najib, Fateme sadat;Hosseinzadeh, Fatemeh;Shahraki, Hadi Raeisi
    • Journal of Pharmacopuncture
    • /
    • v.24 no.4
    • /
    • pp.191-195
    • /
    • 2021
  • Objectives: Vulvovaginal candidiasis (VVC) treatment is advised for all women due to its symptoms and complications. In this study, the standard treatment, clotrimazole, was compared with chamomile extract cream in outpatient clinics. Methods: We recruited 73 women with VVC, who were randomly allocated into two groups, clotrimazole versus chamomile extract cream. After two weeks of treatment with the same criteria, cheese-like vaginal discharge, itching and burning sensations, strawberry cervix, and recovery percentage was evaluated. Results: Thirty patients in each group were analyzed. There was no significant difference in age and number of pregnancies between groups (p = 0.85 and 0.09, respectively). Comparing before and after treatment, cheese like discharge (p < 0.001), itching (p < 0.001), burning (p < 0.001) had significantly improved in both groups. Further, the recovery percentage was not significantly different between groups (88.9% vs 75% in the chamomile vs clotrimazole groups, respectively). Conclusion: Chamomile is as effective as clotrimazole in VVC treatment; a higher percentage of women who used this medication recovered, although this did not reach significance. In addition, no complications were reported in either group.

Potentially Inappropriate Medications and Regimen Complexity on Readmission of Elderly Patients with Polypharmacy: A Retrospective Study

  • Sunmin Lee
    • Korean Journal of Clinical Pharmacy
    • /
    • v.33 no.1
    • /
    • pp.1-7
    • /
    • 2023
  • Background: Along with the increase in the elderly population, concerns about polypharmacy, which can cause medication-related problems, are increasing. This study aimed to find out the association between drug-related factors and readmission in elderly patients within 30 days after discharge. Methods: Data of patients aged ≥65 years who were discharged from the respiratory medicine ward of a tertiary hospital between January and March 2016 were retrospectively obtained. The medication regimen complexity at discharge was calculated using the medication regimen complexity index (MRCI) score, comorbidity status was assessed using the Charlson comorbidity index (CCI), potentially inappropriate medications (PIMs) were evaluated based on the Beer 2019 criteria, and adverse drug events (ADEs) were examined using the ADE reporting system. Multivariable logistic regression analysis was used to evaluate the effect of medication-related problems on hospital readmission after controlling for other variables. Results: Of the 206 patients included, 84 (40.8%) used PIMs, 31 (15%) had ADEs, and 32 (15.5%) were readmitted. The mean age, total medications, MRCI, CCI, and PIMs in the readmission group were significantly higher than those in the non-readmission group. Age significantly decreased the risk of readmission (odds ratio [OR], 0.89; 95% confidence interval [CI], 0.84-0.96) after adjusting for sex, length of hospital stay, and ADEs. The use of PIMs (OR, 2.38; 95% CI, 1.10-5.16) and increased CCI (OR, 1.50; 95% CI, 1.16-1.93) and MRCI (OR, 1.04; 95% CI, 1.01-1.07) were associated with an increased occurrence of readmission. Conclusion: PIMs were associated with a significantly greater risk for readmission than MRCI.

Effectiveness of the Eye Care Protocol in the Intensive Care Unit Patients: A Randomized Controlled Trial (중환자실 입원환자의 눈 간호 프로토콜 적용 효과: 무작위 대조군 전후 실험연구)

  • Lim, Kyu Won;Ha, Shin Young;Kang, In Soon
    • Journal of Korean Academy of Nursing
    • /
    • v.54 no.3
    • /
    • pp.432-445
    • /
    • 2024
  • Purpose: This study investigated the effects of an eye care protocol (ECP) on patients in the intensive care unit (ICU). Methods: This study utilized a randomized controlled design. Participants were patients who met the inclusion criteria and were admitted to the ICU (36 in the experimental group and 38 in the control group). The experimental group received an ECP, while the control group received standard eye care, starting the day after admission, for a duration of 10 days. The ECP classifies the degree of eyelid obstruction into three stages based on the degree of exposure to the lower eyelid conjunctiva and cornea. The protocol included cleansing with normal saline gauze, administering eye drops, applying silicone and polyurethane films, and recommending consultation with an ophthalmologist if necessary. The effectiveness of ECP was assessed by analyzing tear volume, hyperemia, chemosis, and eye discharge. Data analysis was conducted using SPSS 27.0, employing the Mann-Whitney U-test and generalized estimating equations. Results: On day 5, the experimental group demonstrated a significant increase in tear volume in both eyes compared with the control group. However, no statistically significant differences were observed in the incidence of hyperemia, chemosis, and eye discharge on days 5 and 10 of the intervention. Conclusion: The application of the ECP in this study increased tear volume in ICU patients, thereby reducing discomfort caused by dry eyes. It has the potential to prevent complications such as damage to the surface of the eyeball resulting from decreased tear volume.

A Comparison and Analysis of the Levee Height Determination Methods in Korea and the USA (우리나라와 미국의 제방고 산정 기법에 대한 비교 분석)

  • Kang, Tae-Uk;Lee, Sang-Ho;Yu, Kwon-Kyu
    • Journal of Korea Water Resources Association
    • /
    • v.44 no.6
    • /
    • pp.497-510
    • /
    • 2011
  • A levee height is determined by adding a deterministic freeboard to a flood water level in Korea. In the USA, a levee height is determined by choosing a value conditionally among the freeboard criteria and the levels resulted from a probabilistic method. The probabilistic method adopts a conditional non-exceedance probability (CNP) which is the probability that the target stage will not be exceeded given a specific flood event. The purpose of the study is to compare Korean criterion for levee height estimation with that of the USA. Levee heights were determined according to the above two criteria at twenty-five cross sections in five streams. The results show that Korean criterion on average yields levee heights 20 cm higher than those calculated by the criterion of the USA. The larger the flood discharges become, the higher the levee height differences are usually. It is caused by the freeboard estimation criterion of Korea that the larger design flood is, the higher freeboard is given. Korean criterion, however, resulted in lower levee heights for smaller streams than those by the criterion of the USA. To sum it up, the Korean levee height criteria can result in overestimation or underestimation depending on flood discharge amount, being compared with the criteria of the USA. The Korean freeboard especially needs to be increased for smaller flood discharges.

A Study on the Effective Half-life after the High Dose Radioactive Iodine (131I) Therapy for Thyroid Cancer Patients (갑상선암 환자에서 고용량 방사성요오드 치료 후 유효반감기에 대한 연구)

  • Kim, Seongcheol;Gwon, DaYeong;Kim, Yongmin
    • Journal of the Korean Society of Radiology
    • /
    • v.11 no.7
    • /
    • pp.597-603
    • /
    • 2017
  • High-dose $^{131}I$ therapy has been generally carried out to remove remaining thyroid tissue or to cure metastasize lesion of patients who received full thyroidectomy due to differentiated thyroid cancers. In case high-dose $^{131}I$ therapy is carried out for a patient, the patient should be hospitalized being isolated for a certain period in order to restrict the amount of exposure to radiation of people at large from the patient within the limit of a level of radiation. Effective half-life is an important value to calculate how family members are exposed to radiation from a patient or to decide the period of isolation of the patient from the family members. Therefore, in this study we calculated the effective decay constant, effective half-life and period of isolation of high-dose $^{131}I$ therapy patient using NM670 SPECT/CT. As a result of carrying out this study, the effective half-life of high-dose $^{131}I$ therapy patients was derived and the time to reach the discharge level of 1.2 GBq was confirmed. When they were compared with each other in each of curative doses, the effective half-life did not have significant difference, but the time when the level of radiation remaining in the interior of the body to reach the criteria of isolation and discharge showed significant difference and it could be confirmed that the higher the curative dose the longer the period of isolation becomes. When the effective half-lives in each type of preparation were compared with each other, they did not show significant difference. However, When the times to reach the level of radiation that is the criteria of isolation and discharge in each type of preparations, they showed significant difference. The cause of the shortening of the isolation period for rhTSH patients group is decided to be low curative dose. Accordingly, if the current national health insurance (the insurance is applied to using of rhTSH in 3.7 GBq or lower) is maintained, while discerning them in each of types of preparation, we would be able to discharge patients at the time earlier than the current period of isolation (2 nights and 3 days).

The Characteristics of Sediment and a Design Method for Preventing Sediment in the beginning Lateral Sewer (단말 오수관거 에서의 퇴적특성과 퇴적방지를 위한 설계법 고찰)

  • Hwang, Hwan Kook;Kim, Young Jin;Han, Sang Jong;Jung, Ho Chan
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.23 no.6
    • /
    • pp.789-797
    • /
    • 2009
  • The flow in the beginning lateral sewer can be characterized as intermittent and unsteady, and a moment maximum flow energy is required to transport fecal solids in the sewer. It is thus difficult to design to satisfy a minimum velocity criteria (0.6m/s), because of the substantially lower discharge in the beginning lateral sewer. This study is the result of a field survey, and aims to determine a design criteria for the minimum slope to prevent sediment in a lateral sewer. The survey performed on the two flat small catchments in Goyang-si consisting of D400mm hume-pipe, aimed to understand the manner in which the scope of a sewer slope has an effect on sediment in the beginning lateral sewer. The survey showed that the sewer slope below 3‰ had sedimentation of 88.7%, while the sewer slope of 3~6‰ had sedimentation of 47.8%. In addition, the minimum design slope was estimated to refer to the result of hydraulic experiments from Public Works Research Institute in Japan. Analysis showed that the D400mm hume pipe should be installed with a slope of 6.5‰ to prevent sediment in the beginning lateral sewer. For future installations, the study results showed that a D300mm plastic pipe requires a minimum slope of 3.5‰, and a D250mm plastic pipe requires a minimum slope of 3.3‰ in the beginning lateral sewer.