• Title/Summary/Keyword: Discharge Tube

Search Result 335, Processing Time 0.028 seconds

The Algorithm of Life Time Diagnostics end Evaluating of Exchanges Time about High Pressure Sodium Vapor Lamp Using the LabVIEW Software Package (LabVIEW 소프트웨어 패키지를 이용한 고압나트륨전등의 교환시점 및 수명진단 알고리듬)

  • Han, Tae-Hwan
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.18 no.6
    • /
    • pp.1-7
    • /
    • 2004
  • It is necessary for starting voltage to him on high pressure discharge lamp. This starting voltage supply to high pressure sodium vapor lamp as electric discharge lamp, Electric field is producted in Electric discharge tube, So accelerative electron collide against vapour atom and second electron is generated, And rapidly the current flow to Electric discharge tube. This paper showed that the life cycle and exchanges time for all electric discharge lamp was different according to each manufactures, This paper is proposed the evaluating algorithm of exchanges time for high pressure sodium vapor lamp, used LabVIEW software package.

A Diamond-like Film Formation from (CH$_4$ + H$_2$) Gas Mixture with the LPCVD Apparatus (LPCVD 장치를 이용한 메탄과 수소 혼합기체로부터 다이아몬드 박막의 제조)

  • Kim Sang Kyun;Choy Jin-Ho;Choo Kwng Yul
    • Journal of the Korean Chemical Society
    • /
    • v.34 no.5
    • /
    • pp.396-403
    • /
    • 1990
  • We describe how to design and construct a LPCVD (Low Pressure Chemical Vapor Deposition) apparatus which can be applicable to the study of reaction mechanism in general CVD experiments. With this apparatus we have attempted to make diamond like carbon films on the p-type (111) Si wafer from (H$_2$ + CH$_4$) gas mixtures. Two different methods have been tried to get products. (1)The experiment was carried out in the reactor with two different inlet gas tubes. One coated with phosphoric acid was used for supplying microwave discharged hydrogen gas stream, and methane has been passed through the other tube without the microwave discharge. In this method we got only amorphous carbon cluster products. (2) The gas mixture (H$_2$ + CH$_4$) has been passed through the discharge tube with the Si wafer located in and/or near the microwave plasma. In this case diamond-like carbon products could be obtained.

  • PDF

Silent Disicharge Characteristics of Alumina Discharge Tube for Ozone Generation (오존발생을 위한 알루미나 방전관의 무성방전특성)

  • 김학규;곽동주
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2001.07a
    • /
    • pp.783-786
    • /
    • 2001
  • Recently deep interests and attractions have been paid on the generation of ozone, which is widely used to remove bad smell and to clear water. Silent discharge is considered as one of the most effective methods to generator ozone. In this paper, silent discharge reactors were made, waich were filled with different dielectric materials, and some silent discharge charactistics were investigated experimantaiiy.

  • PDF

The Study On Safety of Olive Oil Production Ozonized of Hair and Skin Improvement (모발 및 피부 개선의 오존화 올리브 오일 생산에 대한 안전성에 관한 연구)

  • Park, Sun-Yee
    • Journal of the Korean Applied Science and Technology
    • /
    • v.32 no.3
    • /
    • pp.583-587
    • /
    • 2015
  • This Purpose of this study is to develop a system for stable production without troubling side effects, scalp and skin, and sensitivity to temperature and humidity, but the ozone-cream at a constant effective value and the durability of peroxide safe discharge tube. Furthermore, olive oil and ozone is reacted with the wish to apply to the manufacturing technology. If peroxide value of ozonized olive oil exceeded 1200 meg/kg, there may be microbial disinfection. However, to be produced with a minimum of risk because they look to the scalp and skin sensitization is the purpose of the present study. And also the durability of the discharge tube was tested during the production unit for stable production. And the experimental results, Peroxide value of the ozonized olive oil was measured to less than 1300 meg/kg, also it showed a stable result of the discharge tube.

Effects of an Oral Stimulation Program on the Transition from Tube to Bottle Feeding in Premature Infants (미숙아에게 적용한 구강 자극 프로그램이 젖병 수유로의 이행에 미치는 효과)

  • Kim, Hee-Young;Bang, Kyung-Sook
    • Journal of Korean Academy of Fundamentals of Nursing
    • /
    • v.18 no.2
    • /
    • pp.160-167
    • /
    • 2011
  • Purpose: The purpose of this study was to identify the effects of an oral stimulation program on premature infant's transition from tube feeding to bottle feeding, decrease in desaturation during feeding, and early discharge. Methods: This quasi-experimental study was performed in one neonatal intensive care unit (NICU) of an university hospital. The control group data (n=69) were obtained from June 2008 to May 2009, and the experimental group data (n=67), from June 2009 to May 2010. The oral stimulation program (OSP) was provided daily before feeding for the experimental group until transition to bottle feeding was completed. Results: The OSP group began bottle feeding earlier and were on complete bottle feeding earlier than control group. Discharge delay due to feeding desaturation was lower than for the control group. Conclusion: The results indicate that OSP for premature infants was helpful in transition from tube feeding to bottle feeding and early discharge and thus can contribute health and development in premature infants.

Design and Behavior of Validating Surge Protective Devices in Extra-low Voltage DC Power Lines (특별저전압 직류 전원회로에 유용한 서지방호장치의 설계와 특성)

  • Shim, Seo-Hyun;Lee, Bok-Hee
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.29 no.3
    • /
    • pp.81-87
    • /
    • 2015
  • In order to effectively protect electrical and electronic circuits which are extremely susceptible to lightning surges, multi-stage surge protection circuits are required. This paper presents the operational characteristics of the two-stage hybrid surge protection circuit in extra-low voltage DC power lines. The hybrid surge protective device consists of the gas discharge tube, transient voltage suppressor, and series inductor. The response characteristics of the proposed hybrid surge protective device to combination waves were investigated. As a result, the proposed two-stage surge protective device to combination wave provides the tight clamping level of less than 50V. The firing of the gas discharge tube to lightning surges depends on the de-coupling inductance and the rate-of-change of the current flowing through the transient voltage suppressor. The coordination between the upstream and downstream components of the hybrid surge protective device was satisfactorily achieved. The inductance of a de-coupler in surge protective circuits for low-voltage DC power lines, relative to a resistance, is sufficiently effective. The voltage drop and power loss due to the proposed surge protective device are ignored during normal operation of the systems.

Design of Throttle Orifices for an Aircraft Door Damper (항공기의 도어 댐퍼용 교축 오리피스의 설계)

  • Kwon, Y.C.;Kim, C.H.;Hong, Y.S.;Kim, S.B.
    • Journal of Drive and Control
    • /
    • v.9 no.3
    • /
    • pp.23-28
    • /
    • 2012
  • In this study the flow rate-to-pressure difference characteristics of short-tube type damping orifices for an aircraft door damper were investigated by CFD analyses and experiments. As the design parameters of the damping orifice its diameter, inlet and outlet angle, tube length and the viscosity of the working fluid were taken into consideration. The results showed that the discharge coefficient of the orifices are dependant on the inlet and outlet angle and the oil viscosity, while their length plays an little significant role. Although the short-tube type damping orifice was employed to induce a turbulent flow, their discharge coefficient decreases rapidly as the oil viscosity gets higher than 50mm2/s. Therefore, in order to determine the orifice size, satisfying the working temperature range of the door damper, the oil viscosity as well as the friction force on the damper piston should be kept within proper values. For the verification of the CFD analysis results the actual performance of a door damper was measured and compared with them.

Decomposition of Aqueous Anatoxin-a Using Underwater Dielectric Barrier Discharge Plasma Created in a Porous Ceramic Tube (다공성 세라믹관내에서 생성되는 수중 유전체 장벽 방전 플라즈마를 이용한 아나톡신-a의 분해)

  • JO, Jin-Oh;Jwa, Eunjin;Mok, Young-Sun
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.30 no.2
    • /
    • pp.167-177
    • /
    • 2016
  • This work investigated the decomposition of aqueous anatoxin-a originated from cyanobacteria using an underwater dielectric barrier discharge plasma system based on a porous ceramic tube and an alternating current (AC) high voltage. Plasmatic gas generated inside the porous ceramic tube was uniformly dispersed in the form of numerous bubbles into the aqueous solution through the micro-pores of the ceramic tube, which allowed an effective contact between the plasmatic gas and the aqueous anatoxin-a solution. Effect of applied voltage, treatment time and the coexistence of nutrients such as $NO_3{^-}$, $H_2PO_4{^-}$ and glucose on the decomposition of anatoxin-a was examined. Chemical analyses of the plasma-treated anatoxin-a solution using liquid chromatography-mass spectrometry (LC-MS) and ion chromatography (IC) were performed to elucidate the mineralization mechanisms. Increasing the voltage improved the anatoxin-a decomposition efficiency due to the increased discharge power, but the energy required to remove a given amount of anatoxin-a was similar, regardless of the voltage. At an applied voltage of 17.2 kV (oxygen flow rate: $1.0L\;min^{-1}$), anatoxin-a at an initial concentration of $1mg\;L^{-1}$ (volume: 0.5 L) was successfully treated within 3 min. The chemical analyses using LC-MS and IC suggested that the intermediates with molecular weights of 123~161 produced by the attack of plasma-induced reactive species on anatoxin-a molecule were further oxidized to stable compounds such as acetic acid, formic acid and oxalic acid.

A study of the hollow cathode discharge (HOLLOW CATHODE DISCHARGE의 방전 특성 연구)

  • Cho, S.M.;Seo, Y.W.;Kim, M.J.;Whang, K.W.
    • Proceedings of the KIEE Conference
    • /
    • 1989.11a
    • /
    • pp.139-141
    • /
    • 1989
  • The characteristics of the hollow cathode discharge were investigated. Temperature distribution of the hollow cathode was investigated and I-V curves of the hollow cathode discharge were obtained. In this paper variables are chamber pressure, Ar gas flow rate injected through the cathode tube and the gap distance between cathode and anode. The inter electrode electron temperature and density were measured by Langmuir probe.

  • PDF

A Study on Electromagnetic Joining of Aluminum Tubes to Polyurethane Cores (전자기 성형에 의한 알루미늄 합금관과 폴리우레탄봉의 접합연구)

  • Kim, Nam-Hwan;Son, Hui-Sik;Hwang, Un-Seok;Lee, Jong-Su
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.9 no.1
    • /
    • pp.66-74
    • /
    • 1992
  • The joining processes of aluminum alloy tubes and polyurethane cores by electromagnetic impulsive compression are studied. The influences of various geometrical factors (the length of joined part, the thickness of tube, and the clearance between tube and core) and the process factors(the discharged energy and the number of discharge)are examined experimentally and discussed. And the magnetic pressure in metal/polymer joining is calculated and is compared to the pressure in metal/metal joining. The following results are obtained: (1) The joining strength is dependent upon the residual radial strain of the polyurethane cores. (2) The joining strength increases as discharged energy and the number of discharge increase, but decreases as the clearance, thickness and joining length of tube increases. (3) In the case of metal/polymer joining energy loss is increased and the value of magnetic pressure is less than that in the case of metal/metal joining.

  • PDF