• 제목/요약/키워드: Discharge Tube

검색결과 335건 처리시간 0.026초

주파수 변화에 따라 기체 방전관 색상 제어에 관한 연구 (A Study on Color Control in Gas Discharge Tube with the Variation of Frequency)

  • Lee, Jong-Chan;Park, Dae-Hee
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 1996년도 추계학술발표회논문집
    • /
    • pp.53-56
    • /
    • 1996
  • In this paper, the pulsed mode operated gas discharge tube is composed with mixed gas of Hg-Ne (10 Torr), in the tube of 15.0 mm outer diameter and has variable color from red to blue with changing frequency high voltage. As increasing frequency in the gas discharge tube, the phenomena, that the electron temperature in the positive column increases and the radiation from atoms of higher upper state energy levels increases, exist The color have the locus from red (0.4972, 0.3128) to blue (0.2736, 0.2619) in CIE chromacity diagram with increasing frequency. The method of changing frequency has been shown to be suitable for the luminous color control.

  • PDF

수중 방전을 이용한 유해 세균 검출 분석 연구 (A study on Harmful Bacillus Detection used discharge in water)

  • 조국희;김영배;조문수;박보현;신광철;이동훈
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2004년도 춘계학술대회 논문집
    • /
    • pp.285-289
    • /
    • 2004
  • In this research, we used discharge tube without dielectric bead or with dielectric beads$(SiO_2,\;Al_2O_3,\;or\;ZrO_2)$ for removal of Escherichia coli. At the result of experiments, the removal characteristics of Escherichia coli appeared relation ratio to input voltage. Because, the electric field of discharge tube is increased when input voltage is increased. And, discharge tube used dielectric $bead(ZrO_2)$, the removal characteristics of Escherichia coli was better than cases of else.

  • PDF

냉음극방전관의 기동특성에 미치는 각종광원에 의한 광전효과 (On the Photoelectric Effects of the Various Kinds of Light Source influencing to the Starting Characteristics of the Cold Cathode Type Discharge Tube)

  • 채철곤;원종수
    • 전기의세계
    • /
    • 제13권4호
    • /
    • pp.10-15
    • /
    • 1964
  • It is well known that the starting characteristics of the cold cathode type discharge tube have photoelectric effects by the incident light from outside. After making the cold cathode type discharge tubes to be avaiable for popularizing, the present paper was devoted primaliry to a study of relations between the starting characterstics and photoelectric effects of discharge tube under the oight circumstances of day light, incandescent lamp, flouresent lamp, and mercury lamp we used frequently. The result of this investigation show that the photoelectric effects by flourescent lamp emitting short wave length having close ralation to the photoelectric effects is greater than incandescent lamp or day light, and also mercury lamp emitting shorter wave length than flourescent lamp indicates the greatest photoelectric effects.

  • PDF

회색 관계 이론과 실험계획을 이용한 Lance Tube Nozzle 최적화 (Optimization of Lace Tube with Gray Theory and Design of Experiment)

  • 정일갑;이동명;이상범;임진택
    • 전기학회논문지
    • /
    • 제65권6호
    • /
    • pp.1001-1006
    • /
    • 2016
  • As consumption of energy is increasing rapidly, energy saving is emphasized in nowadays. Thermal power plant occupies a large proportion in various type of power plant. Major causes of decreased power generation efficiency on thermal power stations is deposition of fly ash. Soot Blower is a facility to remove the ash which is deposited outside of tube by steam blowing on boiler. Residual stream which caused by lance tube in soot blower cannot be discharged steam effectively in lance tube causes reducing the thickness of lance tube. On the contrary, increasing discharge ratio of steam, lance tube cannot sustain proper pressure to remove ash on tube. This study suggests increasing discharge ratio of steam with proper pressure to remove ash on tube by optimization on shape of lance tube nozzle. To optimize shape of nozzle, discharge ratio and maximum blowing pressure on nozzle is selected as object functions. Diameter of nozzle, distance between nozzles, angle of nozzle and gap between nozzle is selected as design parameters. Then the design of experiment (DOE) with an orthogonal array is performed to analyze the effect of design parameters. And grey relational analysis and analysis of mean (ANOM) is performed to optimize shape of lance tube.

세라믹(Ba-Ti-Si) 방전관의 오존발생특성 (A Study on Ozone Generation Characteristic Using Ba-Ti-Si Ceramic Tube)

  • 이태관;이동훈
    • 대한환경공학회지
    • /
    • 제28권5호
    • /
    • pp.543-548
    • /
    • 2006
  • 본 논문은 Ba-Ti-Si형 고유전체 세라믹촉매방전관의 오존발생특성에 관해 연구이다. 기본적인 실험조건은 방전관의 외부직경 52 mm, 방전관 길이 350 mm, 전원 주파수 900 Hz, 냉각수 온도 $25^{\circ}C$, 유량 5, 10, 20 L/min, 방전관 내부 압력 1.2, 1.4, 1.6 atm 그리고 방전관과 전극 사이는 0.4, 0.6, 0.8 mm이다. 그리고 실험결과의 특성들은 오실로스코프상에 나타난 리사쥬 도형의 값을 환산한 소비전력으로 유량 20 L/min, 방전간격 0.6 mm, 압력 1.6 atm 그리고 반응기 내의 무성방전에 사용된 소비전력 150 W에서 최대 오존발생효율 175 g/kWh를 얻을 수 있었다. 그리고 최대 오존발생효율 영역은 1.6 atm 이하의 압력에서는 유량 20 L/min 이하에서 측정되었다. 또한 최대 오존발생효율의 영역은 1.6 atm 이상의 압력에서는 유량 20 L/min 이상인 경우에 오존발생 효율이 높아졌다.

세라믹 메탈할라이드 램프의 아크튜브 구조에 따른 광학적 특성 (Optical Properties with Arc Tube Structure of Ceramic Metal-Halide Lamps)

  • 김우영;장혁진;양종경;박형준;박대희
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2009년도 하계학술대회 논문집
    • /
    • pp.378-379
    • /
    • 2009
  • High intensity metal halide discharge lamp performance, specifically the generated luminous flux and light color content, depends critically on the arc tube design. Factors influencing the design and consequent lamp efficacy include : lamp size, geometry, arc tube composition, fill chemistry, electrode design and excitation modes. Shaping of Polycrystalline Alumina(PCA) can be realized by conventional ceramic processes. Several processes are applied nowadays. Well-known in the ceramic high pressure field for decades are the pressing and the extrusion method. Newly developed slurry and precious forming technologies give the one-body seamless tubes, which improve thickness uniformity and lighting performance. Now, we reported some optical properties with different arc tube structures of ceramic metal halide lamps.

  • PDF

세라믹 메탈할라이드 램프 아크튜브 구조에 따른 광학적 특성 (Optical Properties with Arc Tube Structure of Ceramic Metal Halide lamps)

  • 이주호;양종경;김남군;장혁진;박대희
    • 전기학회논문지
    • /
    • 제57권12호
    • /
    • pp.2244-2248
    • /
    • 2008
  • High intensity metal halide discharge lamp performance, specifically the generated luminous flux and light color content, depends critically on the arc tube design. Factors influencing the design and consequent lamp efficacy include : lamp size, geometry, arc tube composition, fill chemistry, electrode design and excitation modes. Shaping of Polycrystalline Alumina(PCA) can be realized by conventional ceramic processes. Several processes are applied nowadays. Well-known in the ceramic high pressure field for decades are the pressing and the extrusion method. Newly developed slurry and precious forming technologies give the one-body seamless tubes, which improve thickness uniformity and lighting performance. Now, we reported some optical properties with different arc tube structures of ceramic metal halide lamps.

유전체를 이용한 수처리장치의 전계시뮬레이션 및 수처리 특성 (Electric Field Simulation and Characteristics of Water Treatment Apparatus using Dielectrics)

  • 황인아;이현수;한병성
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2005년도 추계학술대회 논문집 Vol.18
    • /
    • pp.333-335
    • /
    • 2005
  • The simulation of electric field distribution of discharge tube with globular $ZrO_2$ and the removal characteristic of Escherichia coli by the discharge tube with globular $ZrO_2$ were estimated. The removal characteristic of Escherichia coli was related to the input voltage because the electric field is increased according to input voltage. As the particle size of $ZrO_2$ beads increased, the removal time of Escherichia coli was shortened due to the dielectric polarization of $ZrO_2$ beads.

  • PDF

A Direct Detection of $CO_2$ in Sealed-off $CO_2$ Discharge Tube by Optoacoustic Effect

  • Kim Sung-Ho;Choi Joong-Gill;Cho Ung-In
    • Bulletin of the Korean Chemical Society
    • /
    • 제15권1호
    • /
    • pp.23-25
    • /
    • 1994
  • A simple analytical method that allows direct monitoring of small amount of CO$_2$ in a CO$_2$ discharge tube which utilizes the optoacoustic detection technique is described. The dependence of the optoacoustic signal on the mole fraction of CO$_2$ was shown that the system responded linearly to the amount of CO$_2$ present in the miniature discharge cavity equipped with Cu electrodes. It was also found that fraction of dissociated CO$_2$ varied from 14 to 37% of the initial concentration which depended on the current and the pressure in the tube. This simple and easy detection method has proven to possess the practical advantages over the conventional systems for the study of CO$_2$ laser electrodes.

글로우방전을 이용한 가스크로마토그라프 검출기의 개발 (Glow Discharge as Detector for Gas Chromatography)

  • 김효진;박일영;장성기;김박광;박만기
    • 약학회지
    • /
    • 제37권1호
    • /
    • pp.76-83
    • /
    • 1993
  • The changes in discharge current, emission and/or oscillation frequency of the electric oscillation of a glow discharge are the potential sensitive measure of the concentration of an impurity in the argon plasma supporting gas. A single jet enhanced glow discharge has been interfaced with the gas chromatograph via 1/8" O.D. tube with a heating pad to study the changes in discharge current. To investigate the optimum operating conditions of the glow discharge system as detector for gas chromatography, pressure, gas flow rate, discharge current, distance between the anode and the cathode have been studied.

  • PDF