• 제목/요약/키워드: Discharge Test

검색결과 1,604건 처리시간 0.034초

분사기 형상 변화에 따른 축소형 가스발생기 연소 특성 (Effects of Injector Shape Variation on Combustion Performance of a Subscale Gas Generator)

  • 김문기;임병직;강동혁;안규복;김종규;최환석
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2011년도 제37회 추계학술대회논문집
    • /
    • pp.159-162
    • /
    • 2011
  • 축소형 가스발생기를 제작하여 연소시험을 성공적으로 수행하였으며 분사기의 형상 변화에 따른 유량계수의 영향을 파악하였다. 연소시험 결과 연료 및 산화제 분사기의 유량계수는 혼합비와 연소 압에 상관없이 거의 일정하였으며, 모든 시험조건에서 연소 불안정은 발생하지 않았다.

  • PDF

터널배수재 필터의 폐색 및 수리적 특성에 관한 연구 (A Study on Clogging and Hydraulic Properties for Drain Filters of Tunnels)

  • 문준석;한봉수;장연수;이두화
    • 한국지하수토양환경학회:학술대회논문집
    • /
    • 한국지하수토양환경학회 2001년도 총회 및 춘계학술발표회
    • /
    • pp.111-115
    • /
    • 2001
  • Durability of tunnel drains is important, because the accumulation of groundwater around the tunnel due to clogging of filter or reduction of discharge capacity of drain causes reduction of the life time of tunnel linings. In this paper, clogging and discharge capacity of drain and filter of tunnels are evaluated using a gradient ratio test and filter design criteria. The results of the gradient ratio test showed that gradient ratio(GR) is high when fine content is high in the soil samples and equivalent opening size(EOS) of filter materials is small. Measured GR was less than allowable critical gradinet ratio : 3.0, which is the clogging criteria of U.S. Army Corps of Engineers.

  • PDF

십자형 연직배수재의 점성토지반 개량에의 적용성 (Applicability of Cross Shaped Drain to Soft Clay Improvement)

  • 장연수;김영우;김수삼
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2000년도 토목섬유 특별세미나
    • /
    • pp.9-16
    • /
    • 2000
  • Applicability of the cross shaped drain in a soft clay ground is examined using the laboratory discharge capacity test, column consolidation test and 3-D numerical flow analysis. The equivalent diameter of the tested drains is back-calculated from the laboratory experiment and compared with those calculated from the formula suggested in the literature. The effective range of the cross shaped drain about the discharge capacity and coefficient of permeability is analyzed. The results of numerical analysis show that the cross shaped drain which has a cross-sectional area twice of the band shaped drain can reduce the consolidation time by 30% from that for the band shaped drain in a soft clay ground that K is over 1${\times}$10$\^$-7/cm/sec

  • PDF

UHF PD 센서를 이용한 배전기기 상태감시장치 개발 (The Development of the Condition Monitoring Equipment for distribution Facilities by using the UHF Partial Discharge Sensors)

  • 조용준;황철민;김영노;최재옥;송일근;이병성
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 제39회 하계학술대회
    • /
    • pp.406-407
    • /
    • 2008
  • This paper is analyzed the internal type UHF partial Discharge sensors and Condition Monitoring Module that be able to monitor the condition of the distribution facilities. It set the PD cell on the inside of 22.9kV load switchgear and then it executed Partial Discharge test. it introduced the result of the test.

  • PDF

변압기내 부분방전 탐지 및 위치검출 (Detection and Location of Partial Discharge in Transformers)

  • 곽희노;김재철;황선주;권태원;윤용범
    • 한국조명전기설비학회지:조명전기설비
    • /
    • 제6권4호
    • /
    • pp.53-59
    • /
    • 1992
  • This paper describes an instrument for the detection and geometric location of partial discharge (PD) source in transformers. This instrument measures electric current pulses and ultrasonic pulses simultaneously, counts the number of electrical pulses and determines the geometric location of PD in transformers. It was found that there is a relationship between partial discharge magnitude and pulse repetition rate when the applied test voltage and oil temperature were varied. Through the laboratory test using model transformer, it was clarified that this detector could be used for detecting and locating PD in the transformer.

  • PDF

로고스키 코일과 초음파 센서를 이용한 변압기내 부분방전 탐지 및 위치검출 (Detection and Location of Partial discharge in Transformers Using Logoski coil and Ultrasonic sensor)

  • 곽희로;김재철;김웅상;한민구;권태원;윤용범
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1990년도 하계학술대회 논문집
    • /
    • pp.279-282
    • /
    • 1990
  • This paper describes an nstrument for the detection and geometric location of partial discharge(PD) sources in transformers. This instrument measures electric current pulses and ultrasonic pulses simultaneously, counts the number of electrical pulse and determines the geometric location of PD in transformers. It was found that there is a relationship between partial discharge magnitude and pulse repetition rate when the applied test voltage and oil temperature were varied. Through the laboratory test using model transformer, it was clarified that this detector could be used, satisfactory for detecting and locating of PD in the transformer.

  • PDF

아연도금 강재의 용접성에 미치는 돌기 성형 및 피복조건의 영향 (Effects of Projection Height and Post Treatment on the Resistance Projection Weldability of Zn Coated Sheet Steels)

  • 김기철;이목영
    • Journal of Welding and Joining
    • /
    • 제17권5호
    • /
    • pp.83-88
    • /
    • 1999
  • In this paper resistance projection weldability of Zn coated steels with post treatment has been discussed. Projection welding was performed by a condenser discharge type power source which was equipped with welding parameter monitoring system. Mechanical test results indicated that the effect of post coatings on the projection front changed showing very small very small spattering at the weld strength was negligible. However, contamination rate of the block electrode varied depending on the post treatment coatings. Test results also showed that projection height before welding should be kept to be 80-100% of the specimen thickness as far as the surface quality was taken into consideration. Based on the high speed photography, discharge condition at the beginning stage of the welding process. It was considered that the spattering reduced the weld strength slightly at the optimum heat input range.

  • PDF

Considerations on the Long-term Reliability of On-line Partial Discharge Ceramic Sensor for Thermal Power Generators and its Demonstration in the Field

  • Sun, Jong-Ho;Youn, Young-Woo;Hwang, Don-Ha;Kang, Dong-Sik
    • Journal of Electrical Engineering and Technology
    • /
    • 제7권1호
    • /
    • pp.103-108
    • /
    • 2012
  • The present study describes the considerations on the long-term reliability of the on-line partial discharge (PD) ceramic sensor for thermal power generators. Voltage acceleration aging tests were carried out under continuous and impulsive thermal aging at more than $100^{\circ}C$, considering the practical service environment. Experimental results show that the sensors have a life that could last for more than 100 years, excellent dielectric characteristics, and insulation strength. In addition, the ceramic on-line PD sensors were installed in a thermal power generator in Korea for demonstration. The results of the PD calibration and test voltage application prove that the on-line ceramic sensors have satisfactory performances for on-line PD measurement.

첨가재에 의한 저밀도 폴리에틸렌의 내트리잉성 향상 (Improvement of the resistance to Treeing by additive in Low Density Polyethylene)

  • 김봉협;임기조
    • 대한전기학회논문지
    • /
    • 제35권1호
    • /
    • pp.17-25
    • /
    • 1986
  • Discussions on this paper are related to the effects of organic materials to treeing phenomena of low density polyethylene. As additives, 11 kinds of organic compounds are selected by considering the respective features such as melting point, boiling point, electron affinity as well as molecular structure, and then the specimens of low density polyethylene are prepared by blending with 10wt% of the selected additives. For the comparison of effectiveness of treeing resistance and interpretation of the mechanism of compounds as treeing retardants, several investigations such as the tree acceleration test, the prestressed test and the measurement of internally occurred partial discharge are carried out. As the results, meta-Cresol is regard as the most effective retardant among those, and it is supposed that this aromatic compound to be comprised of radical having large electron affinity has strong capability to accept energetic electron to prevent or delay the growth of discharge streamer. Furthermore, by activating partial discharge at the wall of tree pit through the function of trapped electron at this material, the gas pressure in the pit is increased up to prevent the growth of streamer.

  • PDF

대형발전기 고정자권선 절연재료의 열 사이클에 의한 열화에 관한 연구 (A study on the heat cycle aging of insulation materials in large generator stator windings)

  • 김희곤;박영관
    • 대한전기학회논문지
    • /
    • 제45권4호
    • /
    • pp.553-557
    • /
    • 1996
  • Heat cycle aging of insulating materials in large generator stator winding has been investigated using both on-line and off-line test methods. On this study, principally, off-line test against actual generator in service was carried out to acquire information about polarization index(PI) and dissipation factor, dissipation factor tip-up, maximum partial discharge for the purpose of remnant breakdown voltage and life assessment. It was found from the tests that both dissipation factor and maximum partial discharge decreased with the increase of operating hours and starting numbers. It was found from off-line tests that the remnant breakdown voltage had a strong relationship with both dissipation factor and maximum partial discharge the remnant breakdown voltage as a results of both operating hours and starting number and the nondestructive tests were proposed as parameters which can predict the remnant lifetime of insulating materials in large generator stator windings. (author). 8 refs., 8 figs., 2 tabs.

  • PDF