• Title/Summary/Keyword: Discharge Structure

Search Result 1,054, Processing Time 0.026 seconds

Study on Discharge Characteristics in AC Plasma Display Panel with Open Dielectric Structure (개방형 유전체 구조를 갖는 교류형 플라즈마 디스플레이의 방전 특성 연구)

  • Cho, Byung-Gwon
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.25 no.11
    • /
    • pp.906-909
    • /
    • 2012
  • The address discharge characteristics of a open dielectric structure compared with the conventional panel structure are investigated by measuring the discharge firing voltage. The open dielectric structure could easily produce the discharge between the scan and the sustain electrodes by erasing the dielectric layer between two electrodes. Due to the changes in the discharge firing characteristics of the open dielectric structure between the two sustain electrodes, the conventional reset waveform including the address waveform needs to be modified. The modified driving waveform suitable for the open dielectric structure is proposed and examined in AC PDP.

A Study of Discharge Characteristics in Xe-Ne Gas Mixture for ac PDP with Long Gap Hump Electrode (Long Gap Hump 전극구조를 가진 ac PDP에서의 Xe-Ne 가스의 방전 특성 연구)

  • Heo, Jong-Cheol;Ok, Jung-Woo;Lee, Don-Kyu;Lee, Hae-June;Lee, Ho-Jun;Park, Chung-Hoo
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.58 no.1
    • /
    • pp.155-159
    • /
    • 2009
  • To increase the luminance and luminous efficacy in the discharge for alternating current plasma display panel (ac PDP), the increment of Xe contents and long discharge gap are necessary. However, the driving voltage and the cost of driving circuit increases in the high Xe contents and long discharge path condition. In this paper, a long gap ITO hump electrode (LGH) model for discharge cells of ac PDP is evaluated in the various Xe contents($5{\sim}20%$). The discharge voltage of LGH structure is lower about 30V than that of ITa reference structure with same main discharge gap. The LGH structure has lower power consumption and higher luminance than those of reference structure, respectively. Also, the luminous efficacy of LGH structure is higher about 20% than that of ITO reference structure in the 20% Xe contents.

A Case Research of Application of Submarine Structure for Discharge in the Power Plants (발전소 해양 배수 구조물의 적용사례)

  • Park, See-Boum;Bae, Dong-Chan
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2008.10a
    • /
    • pp.1689-1692
    • /
    • 2008
  • In this research, these days extension of electric power station plant and new building plan is tending to more bigger size and much more cooling water for discharge, therefore submarine structure for discharge has needed various types and the large one. The domestic power plant was applied to once-through CW system structure that pipe line type, immersed PC-box culvert type and submarine headrace tunnel type of discharge structure. It is possible that the future structure type of submarine discharge is expected by a case research of application and plan.

  • PDF

The New Structure in AC PDP with Long Discharge Gap for High Luminance and Luminous Efficacy (AC PDP의 휘도 및 효율 향상을 위한 Long Discharge Gap 전극구조 연구)

  • Dong, Eun-Joo;Ok, Jung-Woo;Lee, Don-Kyu;Lee, Hae-June;Lee, Ho-Joon;Park, Chung-Hoo
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.57 no.5
    • /
    • pp.827-832
    • /
    • 2008
  • One of the most important issues in AC PDP is luminance and luminous efficacy. To improve the luminance and luminous efficacy, new sustain electrode structure which contains long discharge gap is necessary. However, it causes a rise of firing voltage. In this experiment, a new structure is proposed in order to solve this problem. To drop the firing voltage, the hump shaped electrode is inserted into the forward area of the main discharge gap. The experimental results show that proposed structures with 160um discharge gap have high firing voltage by 38V, high luminance by 30% and high luminous efficacy by 15% compared with conventional type having 60um discharge gap. In addition, the proposed structure with hump electrode shows lower firing voltage by 24V compared with the test panel with 160um discharge gap which doesn't have hump electrode though they have similar luminous efficacy.

Fabrication of Micro Structure Using Electro Discharge Deposition (Electro Discharge Deposition (EDD)을 이용한 미세 구조물 제작)

  • 오석훈;민병권;박성준;이상조
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2003.06a
    • /
    • pp.1865-1868
    • /
    • 2003
  • This paper provides a new method for hybrid machining, particularly suited to micro fabrication applications such as micro point, micro line, micro structure, micro partition and so on. Developed micro fabrication process by electrical discharge machining (EDM) and electrical discharge deposition (EDD) with metal powder (Ti, Fe) has been studied to build TiC or FeC structure. Titanium powder or iron powder is supplied from working fluid (kerosene or de-ionized water with powder) and adheres on a workpiece by the heat and electric power caused by the electrical discharge. The use of a tool electrode is expected to keep powder concentration high in the gap between a workpiece and a tool electrode and to accrete powder material on the workpiece. The deposition is tried under various electrical conditions (workpiece. tool electrode, working fluid, discharge current, voltage and powder etc.). On the other hand. using electrical discharge machining (EDM) with the same tool electrode, it can be used as a removal process (cutting) by electro erosion at the same time. Therefore. this new method can do a hybrid machining to build up and down a structure with the workpiece.

  • PDF

Study on Improving the luminous Efficiency of AC PDPs using the Dual Mode Discharge Electrode Structure Having Short-Gap and Long-Gap Discharge (Short-gap과 Long-gap의 이중 방전 전극 구조를 갖는 AC형 플라즈마 표시기의 효율 향상에 대한 연구)

  • 신범재;김태준;이주광;황기웅
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.52 no.11
    • /
    • pp.529-535
    • /
    • 2003
  • In this paper, we presents the characteristics of the new electrode structure in an AC Plasma Display Panel(PDP) that can generate dual mode discharges with a combination of short-gap and long-gap discharges. The experiment results show that the discharge voltage of the new electrode structure is mainly determined by short-gap discharge and the luminous efficiency is improved by 20% compared with the conventional electrode structure. The improvement of luminous efficiency is mainly caused by higher VUV generation and broader distribution from Ole ICCD camera measurements.

Optimal cell structure of a wall-cathode and wall auxiliary anode for high performance plasma display panel (벽형의 음극 전극과 보조 전극을 갖는 고효율 플라즈마 표시기의 최적 전극 구조에 관한연구)

  • 신범제;정희섭;서정현;황기웅
    • Journal of the Korean Institute of Telematics and Electronics D
    • /
    • v.34D no.6
    • /
    • pp.33-42
    • /
    • 1997
  • In this paper, a new structure for a dC plasma display pane(PDP) with a wall-catode and a wall-auxilizry anode has been suggested. The wall-cathode with a sufficient discharge area maximizes the discharge volume. The auxiliary anode surrounding the discharge region makes the effective control of the charged particles possible. We have investigated the cahracteristics of the new cell structure with a 2-dimensional computer simulation and a micro gap discharge system, and compared experimentally with those of previous cell structure. The new cell structure with the wall-cathode and auxiliary wall-anode turned out to have improved luminance, discharge forming time and sustain voltage.

  • PDF

Grounding Resistance and Current Characteristics of the Planar Earth Structure using Multiple Discharge Paths (다중방전 경로를 이용한 편상접지체의 접지저항 및 전류특성)

  • Kim, Young-Sun;Kim, Dong-Min;Lee, Ki-Sik
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.65 no.9
    • /
    • pp.1564-1570
    • /
    • 2016
  • This study proposes a newly modified form of existing ground electrodes in order to secure trust of grounding system for large current caused by a stroke of lightning. Proposed planar earth structure has a several needle electrodes around a circular rod and 4 plane electrodes in all directions. The plane electrodes are fused with the insulator on the linear rod, so that they're electrically isolated. The concept is to increase the discharge amount of earth structure using multiple discharge paths like needle and plane electrodes. To check the discharge efficiency of the suggested scheme, the discharge currents are compared with typically used two kinds of ground rods. To ensure accuracy in the measurement of the discharge current, the same material was used for the comparison model. Also, the ground resistance are simulated by CDEGS commercial software and the results are compared with measured data. Based on this kind of experimental study, the suggested ground rod can be used when designing a ground system or when constructing a ground system at the site.

Effect of Protrusion Electrode of the Electro-Optical Characteristics of AC PDP with Long Electrode Gap (Long 전극갭을 가지는 AC PDP의 전기광학적 특성에 미치는 돌기전극의 영향)

  • Heo, Jeong-Eun;Ok, Jung-Woo;Lee, Don-Kyu;Lee, Hae-June;Lee, Ho-Jun;Park, Chung-Hoo
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.57 no.8
    • /
    • pp.1422-1428
    • /
    • 2008
  • In the current PDP technology, one of the most important issues in AC PDP is improvement of luminance and luminous efficacy. To improve luminance and luminous efficacy, new cell structure of PDP containing long discharge path is necessary. However, it causes an increment of firing voltage. In order to decrease firing voltage of AC PDP having long discharge gap, the protrusion electrode is proposed. To drop the firing voltage, the protrusion electrode is inserted into the forward area of the main discharge gap. This paper presents measurements of detailed optical and electrical characteristics of AC PDP with protrusion electrodes. The experimental results show that the proposed structure with gap 80um has lower firing voltage to 27V than that of the conventional long gap structure. Moreover, the ICCD(Intensified Charge Coupled Device) images of the proposed structure show quick discharge generation by 0.07usec and longer continuation by 0.05usec than that of the conventional long gap structure. Therefore, the proposed protrusion electrodes have higher luminance by 12.5% than that of the conventional structure, as having no decrement of Luminous efficacy.

Characteristic of Facing Discharge Front plate Address Electrode Structure in AC PDP

  • Cho, Hyun-Min;Kim, Dong-Hwan;Song, In-Cheol;Kim, Yun-Gi;Ok, Jung-Woo;Kim, Dong-Hyun;Lee, Hae-June;Lee, Ho-Jun;Park, Chung-Hoo
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2009.10a
    • /
    • pp.104-107
    • /
    • 2009
  • In order to improve discharge characteristics in AC PDP, we suggest FDFA (Facing Discharge Front plate Address Electrode) structure. By adopting both long facing discharge electrodes and address electrodes in front plate, the FDFA structure make it possible to gain a high luminance, low power consumption, and a high luminous efficiency.

  • PDF