• Title/Summary/Keyword: Discharge Site

Search Result 460, Processing Time 0.022 seconds

A Study of the hydrological generation - The generation and comparison with annual and monthly dicharge at Wacgwan in the Nakdong River (수문학적 모의기법에 대한 연구 - 낙동강 왜관지점의 연유량과 월유량의 모의발생 및 비교 -)

  • 천덕진;최영박
    • Water for future
    • /
    • v.13 no.1
    • /
    • pp.49-56
    • /
    • 1980
  • The thesis of this analytical study includes 1) the generation of annual and monthly discharge regarding single hydrological variable at single site, 2)comparsion with the historical records and the generation, and 3) changing the monthly generatied discharge into annual. The conclusion of this will be used for the future plan for water resources development. Annual discharges at waegwan are characterized by log-normal distirbution and persistence-absent. Also, the random number generator causes the errors in the generation of annual discharge. The serial correlation coefficients of the generated annual discharge have less value than that of historical records, while the correlation coefficient and slope in January have(+) value and opposite to historical record. To change the monthly generated discharge into annual is not proper.

  • PDF

Diffusion Modelling of Cold Discharge on Coastal waters (연안역의 냉배수 확산모델링)

  • Kim, Jong-Kyu;Kim, Jong-Hwa
    • Journal of Fisheries and Marine Sciences Education
    • /
    • v.13 no.2
    • /
    • pp.132-145
    • /
    • 2001
  • The cold discharge from LNG(liquefied natural gas) terminal makes the water temperature around the terminal fall down. This temperature reduction may result in serious changes on marine ecosystem of the coastal area. The numerical model experiments of material transport and tidal circulation in the inner bay, Chinhae Bay are investigated in the dispersion of cold discharge from LNG terminal. The condition of ambient water is exposed to tide, tidal current and cold discharge temperature. Simple numerical model experiments highlight the importance of tidal circulation and cold discharge at each case and some results are discussed. The results of this study can be used as the guideline for the site selection of LNG terminals and long-term marine environmental impact assessment.

  • PDF

Construction Method of Zero Discharge System for Environmental Energy Complex in Landfill (매립지내 환경에너지단지의 무방류 시스템 구축방안)

  • Chun, Seung-Kyu
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.27 no.5
    • /
    • pp.581-590
    • /
    • 2013
  • A research was performed for zero discharge system of waste water which is produced from energy recovery process of waste and biomass. Leachate and all kinds of waste water should be separated and integrated into three categories in addition to converting existing leachate treatment facility into waste water treatment facility as well as introducing a management system of reverse osmosis membrane facility and bioreactor landfill. Following these conditions to better water treatment process, it was likely to produce over 3,000 tons of low-grade recycling water and 2,000 tons of high-grade recycling water per day when zero discharge system of waste water is applied starting from 2016. Economical efficiency was also surveyed in total treatment fee. Present system costs 18,129 million won per year, and suggested zero discharge system would cost 15,789 million won per year.

Grounding Resistance and Current Characteristics of the Planar Earth Structure using Multiple Discharge Paths (다중방전 경로를 이용한 편상접지체의 접지저항 및 전류특성)

  • Kim, Young-Sun;Kim, Dong-Min;Lee, Ki-Sik
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.65 no.9
    • /
    • pp.1564-1570
    • /
    • 2016
  • This study proposes a newly modified form of existing ground electrodes in order to secure trust of grounding system for large current caused by a stroke of lightning. Proposed planar earth structure has a several needle electrodes around a circular rod and 4 plane electrodes in all directions. The plane electrodes are fused with the insulator on the linear rod, so that they're electrically isolated. The concept is to increase the discharge amount of earth structure using multiple discharge paths like needle and plane electrodes. To check the discharge efficiency of the suggested scheme, the discharge currents are compared with typically used two kinds of ground rods. To ensure accuracy in the measurement of the discharge current, the same material was used for the comparison model. Also, the ground resistance are simulated by CDEGS commercial software and the results are compared with measured data. Based on this kind of experimental study, the suggested ground rod can be used when designing a ground system or when constructing a ground system at the site.

Experimental Investigation on the Change of Water Discharge Capability of Sluice Caisson for Tidal Power Plant Placed on the Rubble Mound (사석마운드 위에 설치되는 조력발전용 수문 케이슨의 통수성능에 대한 실험적 연구)

  • Lee, Dal-Soo;Oh, Sang-Ho;Lee, Jin-Hak;Park, Woo-Sun;Cho, Hyu-Sang;Eum, Hyun-Min
    • New & Renewable Energy
    • /
    • v.4 no.2
    • /
    • pp.94-104
    • /
    • 2008
  • The change of water discharge capability of sluice caisson for tidal power plant according to installation of the rubble mound was investigated by performing laboratory experiment. The experiment was carried out in an open channel flume with a great care to measure flow rate and water level in the flume accurately. Eight different sluice caisson models were used in the experiment. The water discharge capabilities of seven sluice models decreased with respect to the placement of the rubble mound, while increased for only one sluice model. On average, the values of discharge coefficient decreased by approximately 10% when the sluice models were placed on the rubble mound. It is concluded that the shape of the rubble mound can affect the water discharge capability of the sluice caisson, so that its shape should be significantly considered in the design of the sluice caisson, especially when it is deployed in a site of relatively deeper depth.

  • PDF

Reliability Improvement of Insulation Diagnosis Using the Hydro-Generator On-Line Partial Discharge Monitoring System (수력발전기 On-line 부분방전 측정 시스템을 이용한 절연상태 진단의 신뢰성 향상)

  • Ok, Yeon-Ho;Lee, Eun-Woong;Lim, Jae-Il;Park, Ji-Kun;Kwak, Won-Ku;Lee, Jae-Heung;Shin, Jae-Pil;Shin, Byoung-Chol
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.58 no.4
    • /
    • pp.469-475
    • /
    • 2009
  • Accident dangerousness of domestic hydro power generators which are operated in Korea is on the increase because of use at the long term. On this, the Off-line diagnosis techniques developed to the On-line by continued domestic technical development since 2000. Especially, On-line insulation diagnosis of domestic hydro power generator is possible by localization of partial electric discharge sensor and On-line insulation diagnosis system. This paper shows the diagnosis result that is applied localized Ceramic Coupler and PDMS-HG(Partial Discharge Monitoring System for Hydro Generator) at four Chung-ju hydro Generator used for 25 years. Particularly, the confidence of insulation diagnosis is improved by using high frequency filter and sampling the partial discharge signals which occur in site. For reviewing the confidence of On-Line insulation diagnosis system, we measured the outside noises and partial discharge signals during practical operation by using the partial discharge diagnosis system of the Full A/D process. And we reviewed the confidence of the On-Line insulation diagnosis system by comparing and analyzing these data.

Comparison of Fish Species Composition by Trammel Net at the Intake and Discharge of Weolseong Nuclear Power Plant (월성원자력발전소 취수구 및 배수구에서 삼중자망으로 채집된 어류의 종조성 비교)

  • Ryu, Jung-Hwa;Yoo, Jae Myung;Kim, Jin-Koo
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.49 no.6
    • /
    • pp.883-888
    • /
    • 2016
  • We investigated fish species composition seasonally at the intake and discharge of Weolseong Nuclear Power Plant (WS-NPP) from February to November 2008 using a trammel net. At the intake, 121 individuals belonging to 28 species were collected, and 157 fish from 34 species were sampled at the WS-NPP discharge. Dominant species at the intake were Chelidonichthys spinosus (17.2%), Scomber japonicus (11.5%) and Ditrema temminckii (8.2%) at the intake, while Sillago japonica (18.5%), Chelidonichthys spinosus (13.4%) and Konosirus punctatus (8.3%) dominated at the discharge. The species count and diversity index at the discharge were highest during winter, whereas those at the intake were highest during spring, perhaps due to warm seawater at the discharge site. This study is the first to reveal an effect of effluent water on the aggregation of warm water fish species during winter.

Development of Partial Discharge Measuring System Module by use of Wide and Narrow Band (광대역 및 협대역을 동시에 사용하는 부분방전 측정 시스템 모듈 개발)

  • Lee, Jong Oh;Yu, Kyoung-Kook;Shin, In-Kwon;Chang, Doc-Jin;Ahn, Chang-Hwan
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.29 no.8
    • /
    • pp.98-103
    • /
    • 2015
  • Power plant is that very high reliability when industrial and economic impact on the overall electric power system is required, it is essential to improve the reliability, especially the fault prediction diagnosis. Since an accident caused by the partial discharge in the power plant is above state has a faster response characteristic than the other indications in the case of any, the partial discharge generated in the power plant immediately detect the deterioration of insulation due to the accident of the power plant and the non-drawn It should prevent or reduce. Partial Discharge Measuring Systems for UHV SF6 Gas Insulated Switchgear and power transformer on site installed has some probability of abnormal recognition in case of non-flexible deal with on site noise. Many methode to eliminate these kinds of noises, UHF Detection System is chosen as purchase description in Korea, but this system having a bandwidth between 500MHz 1.5GHz wide band. Initial install periods(about 20 years ago), this band had no strong signal source, but in these days this wide band have strong signals, such as LTE. So, module described in this paper is designed as simultaneously use with wide and narrow band for solve this noise problem, and introduce this system.

Canine Uterine Rupture with Septic Peritonitis Results from Adenocarcinoma in a 2-year-old Maltese Dog

  • Kang, Mun-Il;Cho, Kyoung-Oh;Lee, Sang-Ho;Kim, Yong-Min;Lee, Jun-Cheol;Oh, Ki-Seok;Son, Chang-Ho
    • Journal of Embryo Transfer
    • /
    • v.32 no.4
    • /
    • pp.331-336
    • /
    • 2017
  • A 2-year-old female Maltese dog was presented with a history of anemia and vaginal hemorrhagic discharge. Physical examination revealed severe vaginal hemorrhagic discharge, abdominal pain, pale mucous membranes, low blood pressure and dehydration. Results of serum biochemistry, hematology, venous blood gas, and electrolyte canine C-reactive protein (CRP) test revealed severe normocytic normochromic anemia, severe neutropenia, a high level of CRP, hypoglycemia, and imbalanced electrolytes. Abdominal ultrasound examination showed focal hypoechoic defect with loss of layering in uterine horn wall. A laparotomy revealed a clear reddish fluid in the abdomen, the fistula of left and right uterine horn, the purulent discharge from fistula, and symptoms of septic peritonitis near by the fistula site. The bitch underwent ovariohysterectomy and recovered without complication. Histopathological diagnosis of the uterine fistula site was adenocarcinoma.

Discrimination of Insulation Defects in a Gas Insulated Switchgear (GIS) by use of a Neural Network Based on a Chaos Analysis of Partial Discharge (CAPD)

  • Jung, Seoung-Yong;Ryu, Cheol-Hwi;Lim, Yun-Sok;Lee, Ja-Ho;Koo, Ja-Yoon
    • Journal of Electrical Engineering and Technology
    • /
    • v.2 no.1
    • /
    • pp.118-122
    • /
    • 2007
  • In this work, experimental investigation is carried out in order to design and fabricate the UHF sensor that is able to detect the partial discharges produced from 10 artificial defects introduced into the real scale 70kV GIS mock-up under high voltage within a well shielded room. As well, in order to verify the on-site applicability of our method, the newly proposed CAPD (chaos analysis of partial discharge) is combined with spectral analysis for identifying the nature of 10 artificial defects under investigation. The PD pattern recognition of each defect has been fulfilled by applying our ANN software. The result indicates that the recognition rate reaches up to 80% by the newly proposed method while the traditional PRPD analysis method allows us to obtain 41%. In consequence, it can be pointed out that the proposed method seems likely to be applicable to the real GIS at the site.