• Title/Summary/Keyword: Discharge Rate

Search Result 2,252, Processing Time 0.035 seconds

Comparison of Extracorporeal Cardiopulmonary Resuscitation with Conventional Cardiopulmonary Resuscitation: Is Extracorporeal Cardiopulmonary Resuscitation Beneficial?

  • Lee, Seung-Hun;Jung, Jae-Seung;Lee, Kwang-Hyung;Kim, Hee-Jung;Son, Ho-Sung;Sun, Kyung
    • Journal of Chest Surgery
    • /
    • v.48 no.5
    • /
    • pp.318-327
    • /
    • 2015
  • Background: With improvements in cardiopulmonary resuscitation (CPR) techniques, the quality and the effectiveness of CPR have been established; nevertheless, the survival rate after cardiac arrest still remains poor. Recently, many reports have shown good outcomes in cases where extracorporeal membrane oxygenation (ECMO) was used during prolonged CPR. Accordingly, we attempted to evaluate the impact of extracorporeal cardiopulmonary resuscitation (ECPR) on the survival of patients who experienced a prolonged cardiac arrest and compared it with that of conventional CPR (CCPR). Methods: Between March 2009 and April 2014, CPR, including both in-hospital and out-of-hospital CPR, was carried out in 955 patients. The ECPR group, counted from the start of the ECPR program in March 2010, included 81 patients in total, and the CCPR group consisted of 874 patients. All data were retrospectively collected from the patients' medical records. Results: The return of spontaneous circulation (ROSC) rate was 2.24 times better in CPR of in-hospital cardiac arrest (IHCA) patients than in CPR of out-of-hospital CA (OHCA) patients (p=0.0012). For every 1-minute increase in the CPR duration, the ROSC rate decreased by 1% (p=0.0228). Further, for every 10-year decrease in the age, the rate of survival discharge increased by 31%. The CPR of IHCA patients showed a 2.49 times higher survival discharge rate than the CPR of OHCA patients (p=0.03). For every 1-minute increase in the CPR duration, the rate of survival discharge was decreased by 4%. ECPR showed superiority in terms of the survival discharge in the univariate analysis, although with no statistical significance in the multivariate analysis. Conclusion: The survival discharge rate of the ECPR group was comparable to that of the CCPR group. As the CPR duration increased, the survival discharge and the ROSC rate decreased. Therefore, a continuous effort to reduce the time for the decision of ECMO initiation and ECMO team activation is necessary, particularly during the CPR of relatively young patients and IHCA patients.

Effect of Geometrical Parameters on Discharge Coefficients of a Shear Coaxial Injector (전단동축형 분사기의 유량계수에 대한 형상학적 변수들의 영향)

  • Ahn, Jonghyeon;Lee, Keunseok;Ahn, Kyubok
    • Journal of ILASS-Korea
    • /
    • v.25 no.3
    • /
    • pp.95-102
    • /
    • 2020
  • Six shear coaxial injectors for a 3 tonf-class liquid rocket engine using oxygen and methane as propellants were designed and manufactured by considering geometric design parameters such as a recess length and a taper angle. Cold-flow tests on the injectors were performed using water and air as simulants. By changing the water mass flow rate and air mass flow rate, the injection pressure drop under single-injection and bi-injection was measured. The discharge coefficients through the injector oxidizer-side and fuel-side were calculated and the discharge coefficient ratio between bi-injection and single-injection was obtained. Under single-injection, the recess served to reduce the injection pressure drop on the injector fuel-side. For the injectors without recess, the discharge coefficients under bi-injection were almost the same as those under single-injection. However, for the injectors with recess, the taper angle and bi-injection had a significant effect on the discharge coefficient.

Discharge and loss coefficients for viscoelastic fluids in differential pressure flow meters (차압식 유량계에서 점탄성유체의 유출 및 손실계수)

  • Jeon, U-Cheong;Jo, Byeong-Su;Baek, Byeong-Jun;Park, Bok-Chun
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.20 no.4
    • /
    • pp.1501-1509
    • /
    • 1996
  • Differential pressure devices such as an orifice and Venturi are widely used in the measurement of flow rate of fluid mainly due to cost effectiveness and easy installation. In the current study, the viscoelastic effect on discharge and loss coefficients of those flow meters were investigated experimentally. Aqueous solutions of Polyacrylamide (200, 500, and 800 ppm) as viscoelastic fluids were used. Discharge coefficient of an orifice for viscoelastic fluids increased significantly up to approximately 15-20% when compared with that for water, while loss coefficient decreased up to 10-25% depending on the diameter ratio, .betha.. Also, pressure recovery for viscoelastic fluids was extended much longer than that for water. On the other hand, discharge and loss coefficients of Venturi for viscoelastic fluids were found to be strongly dependent on the Reynolds number. In both flow meters, the concentration effect for discharge and loss coefficients was not observed at more over than 200 ppm of aqueous solution. Conclusively, orifice and Venturi flow meters should be calibrated very carefully in the flow rate measurement for viscoelastic fluids.

Development of a Variable Rate Granule Applicator for Environment-Friendly Precision Agriculture (II) - Development of Pneumatic Fertilizer Blow Head and Its Application Uniformity - (친환경 정밀농업을 위한 입제 변량살포기 개발 (II) -송풍식 붐형 분두 개발과 살포균등도 -)

  • Kim, Y.J.;Kim, H.J.;Seo, M.;Rhee, J.Y.
    • Journal of Biosystems Engineering
    • /
    • v.31 no.6 s.119
    • /
    • pp.474-481
    • /
    • 2006
  • In this paper, a new type blow head was developed and pneumatic application system was evaluated. The blow head had one operating factor, inserting length of collecting plate, that was directly related to discharge rate and application pattern. To determine Proper blow head arrangement and application height, a blow head set was tested. Three-way ANOVA was conducted to investigate relationships between CV value, the discharge rate and inserting length of collecting plate. The discharge rate and inserting length of collecting plate were statistically significant at p=0.01, affecting uniformity of application pattern. The best CV value among the application tests was 23.3% when the application rate and application height was 23.5 g/sec and 80 cm respectively. The worst CV value was 63.3% in 111.4 g/sec. Therefore, it is necessary to increase number of blow head in a section of the boom in improve application uniformity.

The Characteristics of plate type ozonizer according to voltage application method (전압인가 방식에 따른 평판형 오존발생기의 특성)

  • Lee, Chang-Ho;Kim, Jong-Hyun;Youn, Byung-Han;Kim, Ki-Chai;Lee, Kwang-Sik
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2007.11a
    • /
    • pp.203-207
    • /
    • 2007
  • Recently, ozone is utilized in various fields and its needs are expanding. In this paper, plate type ozonizer have been fabricated to investigate discharge parameter(input power, flow rate of supplied gas, electrode form, etc.) effect to discharge. And the conditions of discharge parameter have been investigated for optimum ozone generation. Ozone concentration is continuously increased with increasing input power for same discharge space, and ozone yield is also increased until maximum point after that it is saturated. Ozone concentration is inversely proportional to flow rate of supplied gas but ozone generation and ozone yield characteristics are improved.

  • PDF

Experimental Study on Characteristics of Dry Wire Electrical Discharge Machining (EDM) Process (건성 와이어방전가공 프로세스 특성에 관한 실험적 연구)

  • Lee, Sang-Won;Kim, Hong-Seok
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.27 no.1
    • /
    • pp.11-17
    • /
    • 2010
  • This study investigates the non-traditional manufacturing process of dry wire electrical discharge machining (EDM) in which liquid dielectric is replaced by a gaseous medium. Wire EDM experiments of thin workpieces were conducted both in wet and dry EDM conditions to examine the effects of spark cycle (T), spark on-time ($T_{on}$), thickness of work pieces, and work material on machining performance. The material removal rate (MRR) in the dry wire EDM case was much lower than that in the wet wire EDM case. In addition, the thickness of workpiece and work-material were found to be critical factors influencing the MRR for dry EDM process. The relative ratios of spark, arc and short circuit were also calculated and compared to examine the effectiveness of processes of dry and wet wire EDM.

A Study on the Performance Prediction of Automotive Water Pump with Double Discharge Single Suction (자동차용 양토출 단흡입 워터펌프의 성능 예측에 관한 연구)

  • 허형석;박경석;이기수;원종필
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.12 no.3
    • /
    • pp.27-36
    • /
    • 2004
  • A Numerical analysis has been used to predict the performance in the automotive water pump with double discharge single suction. The influence of parameters such as coolant flow rate, rotational speed, ratio of blade height and clearance has been investigated. Also, the prediction of hydraulic performances such as static pressure rise, shaft power, hydraulic power and pump efficiency is carried out on the water pump including an impeller and a volute casing. A full size water pump test bench has been developed to validate the CFD flow model. Discharge flow rate, suction pressure, discharge pressure, rotational speed and torque measurements are provided. Coolant temperature is 8$0^{\circ}C$, water tank pressure is 1 kgf/$\textrm{cm}^2$ and flow rates vary.

The effect of the MgO process on the properties of AC-PDPs

  • Kim, Young-Sung;Park, Min-Soo;Ryu, Byung-Gil
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2007.08b
    • /
    • pp.1376-1379
    • /
    • 2007
  • The effects of the MgO fabrication process on the properties of AC-PDPs were examined. MgO films were deposited by e-beam evaporation with various substrate temperatures and oxygen flow rates. MgO films were analyzed by XRD, CL and ellipsometer. Panel properties such as luminance, efficiency, discharge voltage and discharge delay time were measured with test panels. MgO films with higher temperature, smaller oxygen flow rate showed shorter discharge delay time. Also they showed smaller XRD peak intensity. These results revealed that the discharge delay time was strongly influenced by temperature and oxygen flow rate of the MgO fabrication process.

  • PDF

Decomposition Characteristics of Municipal Solid Wastes in Lysimeter Without Leachate Discharge (침출수 무배출식 모형매립조를 이용한 도시폐기물 분해특성)

  • 류돈식;이해승;이찬기
    • Journal of environmental and Sanitary engineering
    • /
    • v.15 no.2
    • /
    • pp.49-57
    • /
    • 2000
  • The objective of this study is to find solid waste decomposition in landfill without leachate discharge. This study was observed variation of landfill gas production rate and leachate for stabilization assessment, and using four sets of lysimeter as experimental apparatus. Soild waste decomposition was accelerated in without leachate discharge system by sufficient moisture for methane bacteria. And gas production rate was between 54.2ℓ/kg VS∼335.9ℓ/kg VS in each lysimeter. Generation time of methane gas was showed different in each lysimeter, but it was much faster than literature research. The time of stabilization phase were began as follows : L-1 400 day, L-2 350 day, L-3 170 day and L-4 70 day respectively. Decreasing times of BOD/COD ratio and C/N ratio were necessary more than literature research because organic matter was not discharge such as wash out.

  • PDF

강변여과수 취수에 따른 지하수위의 계절적인 변동 특성

  • Jeong Jae-Yeol;Ham Se-Yeong;Lee Jeong-Hwan;Kim Hyeong-Su;Ryu Sang-Hon;Kim Tae-Won;Kim Mun-Su
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2006.04a
    • /
    • pp.68-71
    • /
    • 2006
  • Seasonal fluctuation of groundwater level by pumping amount and stream discharge at the riverbank filtrate site adjacent to the Nakdong River in Daesan-Myeon was characterized. Groundwater level fluctuation shows increase in wet season (June, July, August and September) and decrease in dry season (the other months). Seasonal variation of pumping amount shows similar trend to the groundwater fluctuation due to higher consumption of potable water in summer. The relation of specific capacity, Nakdong River and pumping quantity was analyzed. The logarithmic relationship between specific capacity and the stream discharge gives high correlation coefficient, 0.96. This fact indicates that the increase of stream discharge rate reduces the rate of drawdown in the pumping area in wet season.

  • PDF