• Title/Summary/Keyword: Discharge Performance

Search Result 1,668, Processing Time 0.03 seconds

Influence of Partial Discharge Properties due to Void in Cable Joint Parts (케이블 접속재 부분방전 특성에 미치는 보이드의 영향)

  • 신종열;홍진웅
    • Journal of the Korean Society of Safety
    • /
    • v.18 no.3
    • /
    • pp.69-74
    • /
    • 2003
  • To investigate the partial discharge and electric field distribution in cable joint parts, we measured the partial discharge and electric field in specimen. The specimens which cross-linked polyethylene(XLPE) and ethylene propylene diene ethylene(EPDM) are used to insulating material for underground cable md cable jointing parts. The polymers are used to insulating material in switchgear which is a kind of transformer equipment and in ultra-high voltage cable. Its using is increasing gradually, the electrical insulation properties are not only excellent but also mechanical property is excellent. And because it is possible to be made void of several type in insulator while it is produced, which the electrical field distribution is changed by void, it has a critical influence to insulator performance. The underground cable is connecting by the jointing material, insulating breakdown and the electric ageing which are caused by several mixing impurity and the damage of cable insulator layer, which reduced the life of cable while intermediate joint kit is connected. Therefore, the computer simulation is used to estimating insulator performance, XLPE is used to the insulating material of ultra-high voltage cable and EPDM is used to insulator layer in joint material kit, and which are produced as specimen. And it is analyzed the electric field concentrating distribution and partial discharge by modeling of computer simulation in void and cable joint kit.

회전기 고정자권선의 부분방전 진단용 평면 패치센서의 설계 및 실험

  • Yang, Sang-Hyeon;Park, No-Jun;Kim, Chung-Sik;Park, Dae-Hui
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2009.11a
    • /
    • pp.228-228
    • /
    • 2009
  • In stator windings of a 6.6kV rotating machine, internal discharge, corona discharge, and surface discharge are mainly caused by internal voids and insulation degradation. In the case of the discharge spark and electromagnetic pulse generated from a discharge source, we can detect it using various RF resonators like an EM sensor. In order to detect these types of electromagnetic sources, we designed and fabricated a planar patch sensor using a CST-MWS simulation, and PD signals from artificial defected stator windings were also measured by the sensor proposed in this study. Furthermore, In the results of the experiment, it showed similar performance to the HFCT sensor.

  • PDF

Determination of Electrical Discharge Machining Parameters from the CMM data of a Electrode (전극의 3차원 측정데이터로부터 방전가공조건 결정)

  • 주상윤
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.9 no.5
    • /
    • pp.58-64
    • /
    • 2000
  • This paper proposes a method for determining optimal EDM parameters based on discharge area from the physical model of a tool electrode. Main parameters, which affect the EDM performance, are peak value of currents, pulse-on time, and pulse-off time. Such parameters are closely dependent on the discharge area in EDM process. In this paper the discharge area is estimated from the CMM scanning data to the tool electrode. The method is very useful when any geometric information to the tool electrode is not provided from tool modeler or producer. The method consists of following four steps. First a triangulation mesh is constructed from the CMM data. Secondly, the z-map is modeled from the triangulated mesh. Thirdly, the discharge area is estimated from intersection between the z-map model and a z-height plane. Finally, the machining parameters are easily calculated by some known EDM equations to the discharge area. An example is introduced to show that the machining parameters are calculated from the CMM data to a tool electrode.

  • PDF

Discharge Coefficients of Orifice Hole in the Cartridge of Constant Flow Control Valve (정유량 밸브의 카트리지의 오리피스 구멍의 유출계수)

  • Yoo, Seon-Hak;Kang, Seung-Duk;Yang, Eui-Seok;Park, Kyung-Am
    • 유체기계공업학회:학술대회논문집
    • /
    • 2004.12a
    • /
    • pp.305-308
    • /
    • 2004
  • The constant flow control valve is used to control the flow rate of heating water in the large apartment complex and buildings. It is important to have similar heating flow rate in the apartments, even though the apartment is top or bottom floors. To achieve those purposes, the constant flow control valve was developed. The performance of this control valve is effected by hole area and discharge coefficients of the cartridge holes. The discharge coefficients of orifice hole in the cartridge were testes with various sizes of holes and various flow direction in the holes. The discharge coefficients decreased as the hole size increased due to the collision at the cartridge wall of water jet. The effects of the flow direction at the hole were not significant on the discharge coefficients.

  • PDF

Injector Discharge Characteristics of Liquid Rocket Engine (액체 로켓엔진의 분사기 유출 특성)

  • 조원국;류철성;김영목
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.5 no.4
    • /
    • pp.12-19
    • /
    • 2001
  • The discharge characteristics of the oxidizer injector of liquid rocket engine were investigated. The discharge performance was obtained numerically which agreed quantitatively with the measured data. The discharge coefficient is proportional to the cavitation number for cavitating flow and constant for non-cavitating flow. The Reynolds number, however, affects little the discharge coefficient. The discharge coefficient decreased slightly as the Reynolds number increased because the friction loss decreased relatively at high Reynolds number flow.

  • PDF

A study on NOx removal in double barrier discharge reactor using pulse power supply (펄스방전을 사용한 이중베리어방전 반응기에 있어서 NOx 제거에 관한 연구)

  • 김동욱;김응복;정영식
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1999.11a
    • /
    • pp.169-172
    • /
    • 1999
  • In this experimental study we Proposed the double dielectric barrier discharge (DDBD) reactor to produce as high an electric field as possible. The experiment are conducted for applied voltage from 15 to 20[tV], flow gas rage at 2[1/min] and pulse rate at 120[pulses/s] and 240[pulses/s]. SPD connection of DDBD which combine the surface discharge with the silence discharge was most effective to reduce the NOx. In the decomposition efficiency per watt, the low pulse rate gave hotter efficiency than that of the high pulse rate. However in DeNOx rate, the high pulse rate gave better performance than that of the low pulse rate. NOx removal rate increased with increasing the applied voltage in all reactors.

  • PDF

The Needs for Discharge Education and Educational Performance of Nurses Perceived by Premature Infants Mothers In the ICT Medical Service (ICT 의료시설 기반에서 미숙아 어머니의 퇴원 교육 요구도와 간호사의 교육수행 정도)

  • Kim, Soo-Heui;Choi, Seong-Woo;Ryu, So-Yeon;Han, Mi-Ah
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.11 no.7
    • /
    • pp.707-716
    • /
    • 2016
  • The current research focused on the needs for discharge education and the educational performance of nurses perceived by mothers of premature infants. The subjects for the current research were 54 mothers of premature infants hospitalized in the neonatal intensive care unit at K general hospital in G metropolitan city. The data was collected between June 9, 2014 and September 30, 2014 through self-recording surveys. The needs for discharge education were $4.21{\pm}0.60$ and the perceived educational performance of nurses was $3.95{\pm}0.73$. There was a significant difference between the needs for discharge education and the perceived educational performance in abnormal symptom monitoring and management ($0.55{\pm}0.97$, p=0.001), excrement management ($0.45{\pm}1.11$, p=0.004) and growth development ($0.41{\pm}1.08$, p=0.007). The needs for discharge education was significantly different according to delivery type (vaginal delivery: $4.41{\pm}0.47$, caesarean section: $4.03{\pm}0.47$, p=0.040) and birth order (first: $4.37{\pm}0.53$, second: $4.25{\pm}0.51$, over third: $3.75{\pm}0.72$, p=0.031). Perceived educational performance of nurses was significantly different according to baby sitter (yes: $4.15{\pm}0.66$, no: $3.48{\pm}0.67$, p=0.002). ]

Enhancement Technique of Discharge Measurement Accuracy Using Kalesto Based on Index Velocity Method in Mountain Stream, Jeju Island (지표유속법 기반 제주 산지형 하천 Kalesto 유량 정확도 향상 기법)

  • Kim, Dong-Su;Yang, Sung-Kee;Kim, Soo-Jeong;Lee, Jun-Ho
    • Journal of Environmental Science International
    • /
    • v.24 no.4
    • /
    • pp.371-381
    • /
    • 2015
  • In the mountain streams in Jeju Island, strong turbulence and roughness usually made it nearly impossible to utilize most of intrusive instrumentation for streamflow discharge measurements. Instead, a non-intrusive fixed electro-magnetic wave surface velocimetry (fixed EWSV: Kalesto) became alternatively popular in many representative streams to measure stream discharge seamlessly. Currently, Kalesto has shown noteworthy performance with little loss in flood discharge measurements and also has successfully provided discharge for every minute. However, Kalesto has been operated to regard its measured one-point velocity as the representative mean velocity for the given cross-section. Therefore, it could be highly possible to potentially encompass discharge measurements errors. In this study, we analyzed the difference between such Kalesto discharge measurements and other alternative concurrent discharge measurements such as Acoustic Doppler Current Profiler (ADCP) and mobile EWSV which were able to measure velocity in multi-points in the cross-section. Consequently, Kalesto discharge deviated from ADCP discharge in amount of 48% for relatively low flow, and more than 20% difference for high flow compared with mobile EWSV discharge measurements. These results indicated that the one-point velocity measured by Kalesto should be used as a cross-sectional mean velocity, rather it should be accounted for as an index-velocity in conjunction with directly measured cross-sectional mean velocity by using more reliable instrumentations. After inducing Kalesto Discharge Correction Coefficient (KDCC) that actually means relationship between index velocity and cross-sectional mean velocity, the corrected discharge from Kalesto was significantly improved. Therefore, we found that index velocity method should be applied to obtain better accuracy of discharge measurement in case of Kalesto operation.

Comparison of Artificial Neural Network for Partial Discharge Diagnosis (부분방전 진단을 위한 인공신경망 기법의 비교)

  • Chung, Gyo-Bum;Kwack, Sun-Geun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.9
    • /
    • pp.4455-4461
    • /
    • 2013
  • This paper investigates the diagnosis performance of Artificial Neural Network (ANN) depending on the structure and the input vector type of ANN, which has been used to detect the partial discharge to lead to the electric machinery deterioration. The diagnosis performance of one hidden layer and two hidden layer in ANN are compared. The performance using the 2048 time-series data and the performance using the feature input vector are compared. For measuring the partial discharge signal, the tip-to-plate, the sphere-to-sphere, the tip-to-tip, the tip-to-sphere and the sphere-to-plate electrodes are used respectively. For ANN's learning, Matlab and C-code program are used. For evaluating the diagnosis performance of ANNs, the simulation studies are performed.

Construction of small hydropower facilities performance evaluation system (소수력 발전설비 성능평가 시스템 구축)

  • Kim, Youngjoon;Kim, Yongyeol;Cho, Yong;Ko, Jaemyoung
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2010.06a
    • /
    • pp.193.2-193.2
    • /
    • 2010
  • Domestic hydroelectric power plants has been manufactured as the design condition by the demand. Hydraulic turbine power plants operating at appointed load shall be operate stable in terms of pressure, discharge, rotational speed and torque. A performance guarantees for hydro turbines shall be contain, as a minimum, guarantees covering power, discharge and specific hydraulic energy, efficiency, maximum momentary overspeed and maximum momentary pressure and maximum steady-state runaway speed, as well as guarantees related to cavitation. But, present in Korea, the absence of testing laboratories and technical criteria for the performance test of small hydropower degrades the efficiency of the domestic hydropower machines, and makes it difficult to objectively evaluate the performance of hydro turbine. Therefore We planned making a basis of performance test of small hydropower turbine by using our flowmeter calibration system the largest one in Korea. We planned the maximum measurable power of hydro turbine will be 200 kW in our system.

  • PDF