• Title/Summary/Keyword: Discharge Performance

Search Result 1,678, Processing Time 0.025 seconds

Cavitating Flow in an Impinging-type Injector (충돌형 분사기 내의 캐비테이션 유동)

  • Jo, Won Guk;Ryu, Cheol Seong;Lee, Dae Seong
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.31 no.5
    • /
    • pp.80-86
    • /
    • 2003
  • An anaysis on the discharge performance of an impinging-type injector for cavitating flow has been conducted by both numerical and experimental method. The predicted discharge coefficient for cavitating flow agrees well with the measured data showing less than 1% discrepancy. For the case of non-cavitating flow analysis, the disagreement between CFD results and the experimental data is 8%. The discharge coefficient for the cavitating flow decreases with decrease in the Reynolds number. On the other hand, it increases slightly as the Reynolds number increases for the non-cavitating flow because of the reduced viscous effect. From the present study, it is confirmed that the fact that cavitation phenomena should be included to predict accurately the discharge performance of injectors for cavitating flow regime. The uniformity of density and velocity magnitude degraded at the injector exit, and the secondary flow strength through the injector orifice accentuated due to cavitation.

PD Signal Time-Frequency Map and PRPD Pattern Analysis of Nano SiO2 Modified Palm Oil for Transformer Insulation Applications

  • Arvind Shriram, R.K.;Chandrasekar, S.;Karthik, B.
    • Journal of Electrical Engineering and Technology
    • /
    • v.13 no.2
    • /
    • pp.902-910
    • /
    • 2018
  • In recent times, development of nanofluid insulation for power transformers is a hot research topic. Many researchers reported the enhancement in dielectric characteristics of nano modified mineral oils. Considering the drawbacks of petroleum based mineral oil, it is necessary to understand the dielectric characteristics of nanofluids developed with natural ester based oils. Palm oil has better insulation characteristics comparable to mineral oil. However very few research reports is available in the area of nanofluids based on palm oil. Partial discharge (PD) is one of the major sources of insulation performance degradation of transformer oil. It is essential to understand the partial discharge(PD) characteristics by collecting huge data base of PD performance of nano modified palm oil which will increase its confidence level for power transformer application. Knowing these facts, in the present work, certain laboratory experiments have been performed on PD characteristics of nano $SiO_2$ modified palm oil at different electrode configurations. Influence of concentration of nano filler material on the PD characteristics is also studied. Partial discharge inception voltage, Phase resolved partial discharge (PRPD) pattern, PD signal time-frequency domain characteristics, PD signal equivalent timelength-bandwidth mapping, Weibull distribution statistical parameters of PRPD pattern, skewness, repetition rate and phase angle variations are evaluated at different test conditions. From the results of the experiments conducted, we came to understand that PD performance of palm oil is considerably enhanced with the addition of $nano-SiO_2$ filler at 0.01%wt and 0.05%wt concentration. Significant reduction in PD inception voltage, repetition rate, Weibull shape parameter and PD magnitude are noticed with addition of $SiO_2$ nanofillers in palm oil. These results will be useful for recommending nano modified palm oil for power transformer applications.

A Study on the Performance of Recycled Cells for application to Residential BESS (주택용 BESS에 적용하기 위한 재활용 셀의 성능에 관한 연구)

  • Phil-Jung Kim;Seong-Soo Yang
    • Journal of IKEEE
    • /
    • v.28 no.1
    • /
    • pp.14-19
    • /
    • 2024
  • To determine the performance of recycled cells for application to residential BESS, cells used over the past 5 years were selected. The basic specifications of the cell used in the test are nominal voltage of 3.7[V], nominal capacity of 2,200[mAh], charging voltage of 4.05[V], continuous discharge current of 1[C](2,200[mA]), continuous charging current of 0.5[C](1,100[mA]). For new cells, the internal resistance was 21.3±1[mΩ], but for recycled cells, the average internal resistance was 25.38[mΩ], an increase of about 19.1[%]. The charge·discharge capacity was approximately 18.9~19.3[%] lower than that of a new cell. Because internal resistance and charge·discharge capacity are closely related to cell aging, cells to be applied to BESS need to use products with an initial internal resistance of 1.5 times or less and a charge·discharge capacity performance of 70[%] or more.

Examination on Fire Extinguishing Performance of Full Cone and Hollow Cone Twin-fluid Atomizers: Effects of Supply Gas and Water Mist (중실원추형 및 중공원추형 2유체 미립화기의 화재 소화 성능 검토: 공급 기체와 미분무 영향)

  • Kim, Dong Hwan;Lee, Chi Young
    • Fire Science and Engineering
    • /
    • v.33 no.5
    • /
    • pp.28-36
    • /
    • 2019
  • In the present study, the effects of supply gas and water mist on the heptane pool fire extinguishing performance were investigated using the full cone and hollow cone twin-fluid atomizers. Air or nitrogen of 30 lpm (Liter per minute; L/min) was used as the supply gas, and the experiments were conducted under the water flow rate conditions of 0 lpm (i.e., discharge of air or nitrogen only) and 0.085 lpm (i.e., discharge of water mist with supply gas). Experimental results confirmed that the use of water mist discharge with the supply gas and full cone spray pattern reduced the fire extinguishing time as compared to that of only supply gas discharge and hollow cone spray pattern. In addition, for the discharge of water mist using the full cone twin-fluid atomizer, water mist significantly affected fire extinguishing performance, whereas the effect of the supply gas was less pronounced. On the other hand, for the discharge of water mist using the hollow cone twin-fluid atomizer, the fire extinguishing time was remarkably reduced by the supply of nitrogen, as compared with that of air, indicating that the supply gas as well as water mist can significantly affect fire extinguishing performance.

Performance Characteristics of a Pin-to-Cylinder Superposed Discharge Type Ozonizer (SDO)

  • Md. Fayzur Rahman;Lee, Kwang-Sik
    • KIEE International Transactions on Electrophysics and Applications
    • /
    • v.11C no.4
    • /
    • pp.113-119
    • /
    • 2001
  • This paper presents a model for a pin-to-cylinder discharge type ozonizer, which utilizes the superposition of surface discharge and corona discharge operation. By changing the gas flow rate, the discharge power and the number of SDO units, the characteristics of ozone concentration ( $O_{3con}$), ozone generation ( $O_{3g}$) and ozone yield ( $O_{3Y}$) were investigated. Using one SDO unit the maximum values of $O_{3con}$, $O_{3g}$ and $O_{3Y}$ were found as 8100[ppm], 1623[mg/h] and 213[g/kWh] respectively. With two SDO units the corresponding values were found as 12800[ppm], 2893[mg/h] and 248[g/kWh] respectively. Hence using two SDO units the efficiency was improved by 16[%].y 16[%].

  • PDF

Fundamental Investigation Results on Ozone Generation Characteristics by Superimposed Discharge (중첩방전에 의한 오존생성 특성)

  • ;Chobei YAMABE
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.52 no.2
    • /
    • pp.91-97
    • /
    • 2003
  • In addition to its strong oxidizing power, the ozone has definite advantages over other commercial oxidants, namely, no undesirable by- products or residues are formed. With growing interest in the improvement of the ozone production in the industrial fields, many types of ozonizer using the electrical discharges have been proposed for the higher efficiency and the higher Performance at atmospheric Pressure. Among them, a superposition of different type discharges has been proposed. Especially, since the improvement for the low efficiency of dc discharge and narrow gap of surface discharge is required, a do and an at voltage are applied to same reaction space (or volume) to increase energy density at the same space. An investigation was focused on the superposition with a dc (streamer) corona and 3 surface discharge. This paper describes the investigation results on fundamental ozone generation characteristics by this superimposed discharge.

Implementation of an Inductively Coupled EM Probe System for PD Diagnosis

  • Kim, Hee-Dong;Park, Noh-Joon;Park, Dae-Hee
    • Journal of Electrical Engineering and Technology
    • /
    • v.6 no.1
    • /
    • pp.111-118
    • /
    • 2011
  • In recent years, various types of partial discharge (PD) methods such as capacitive, inductive, electromagnetic, and acoustic coupling techniques have been developed for diagnosing rotating machines. An electromagnetic (EM) probe, which is an inductively coupled type of sensor, is required for detecting corona and internal discharges during off-line tests. In this study, a new technique for enhancing the measurement sensitivities for corona and internal discharge based on an EM inductive position sensor is proposed. An EM probe that winds wires around horseshoe-shaped and cylindershaped ferrites as helices is designed and optimized for the implementation of off-line PD monitoring of the stator winding of a rotating machine. The measurement system based on this design is implemented, and it is verified from the results of the experiment performed in this study that the probe provides similar performance as existing commercial products.

Determination of Machining Parameters Considering Current Density in Three Dimensional Electrical Discharge Machining (3차원 방전가공에서 전류밀도를 고려한 방전가공조건 결정)

  • 이건범;김정두;최병훈;송희덕
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.8 no.3
    • /
    • pp.100-106
    • /
    • 1999
  • Owing to the complexity of electrical discharge machining (EDM) phenomenon, it is very difficult to determine optimal machining parameters fer improving machining performance. This paper proposes a methodology for determining optimal electrical discharge machining parameters, which is maintaining suitable current density for increasing productivity or improving surface roughness. Machining area is closely related on optimal machining parameters in electrical discharge machining process, so calculation of machining area is needed in order to determine optimal machining parameters. In this study machining area, which is corresponding to the machining position, is calculated from intersection curves between the tool surface and a horizontal plane.

  • PDF

Optimal cell structure of a wall-cathode and wall auxiliary anode for high performance plasma display panel (벽형의 음극 전극과 보조 전극을 갖는 고효율 플라즈마 표시기의 최적 전극 구조에 관한연구)

  • 신범제;정희섭;서정현;황기웅
    • Journal of the Korean Institute of Telematics and Electronics D
    • /
    • v.34D no.6
    • /
    • pp.33-42
    • /
    • 1997
  • In this paper, a new structure for a dC plasma display pane(PDP) with a wall-catode and a wall-auxilizry anode has been suggested. The wall-cathode with a sufficient discharge area maximizes the discharge volume. The auxiliary anode surrounding the discharge region makes the effective control of the charged particles possible. We have investigated the cahracteristics of the new cell structure with a 2-dimensional computer simulation and a micro gap discharge system, and compared experimentally with those of previous cell structure. The new cell structure with the wall-cathode and auxiliary wall-anode turned out to have improved luminance, discharge forming time and sustain voltage.

  • PDF

Application of Air Lift Pump for Sludge Discharger (공기 양정(air lift) 펌프를 응용한 슬러지 배출장치에 대한 연구)

  • Ahn Kab-Hwan;Park Young-Seek
    • Journal of Environmental Science International
    • /
    • v.13 no.10
    • /
    • pp.929-938
    • /
    • 2004
  • Sludge discharger applied the principle of the air lift pump was investigated experimentally for the different design( diameter of discharge pipe, diameter and height of the inside and outside wall) and operating parameters(air flow rate, water level). And it was conducted that performance comparison about sludge discharger and conventional air lift pump. The result indicated that discharged liquid were increased with the increase of air flow rate and water level and decrease distance between inside and outside wall. The discharge pressure was increased with an increase of air flow rate and a decrease of the diameter of the discharge pipe, for both the sludge discharger and the airlift pump. The discharge pressures of the sludge discharger were 3-6 times higher than those of the air lift pump.