• 제목/요약/키워드: Discharge Mechanism

검색결과 337건 처리시간 0.028초

유동대전에 의한 절연유중의 정전기 방전기구와 대책에 관한 연구 (A Study on the Mechanism and Countermeasure of Electrostatic Discharge in Insulating Oil by Streaming Electrification)

  • 박광현;임헌찬;김두식;황명환;육재호;이덕출
    • 한국안전학회지
    • /
    • 제8권2호
    • /
    • pp.10-15
    • /
    • 1993
  • In this paper, it is studied the electrostatic discharge In Insulating oil for the purpose of the technical control of the streaming electrification resulted from the interface between an insulating liquid and a solid. The streaming current increases exponentially with flow rate and In region of lower than 50[$^{\circ}C$]but decreases at higher than the same temperature. The phenomena of electrostatic discharge appear at an interface between measuring tank and insulating oil when the seven sheets of gauzes are inserted in electrification apparatus. And those of partial or surface discharge are shown when eight sheets are inserted.

  • PDF

Formation of Difluorobenzyl Radicals from 2,3,4-Trifluorotoluene in Corona Excitation

  • Yoon, Young-Wook;Lee, Gi-Woo;Lee, Sang-Kuk
    • Bulletin of the Korean Chemical Society
    • /
    • 제32권6호
    • /
    • pp.1993-1996
    • /
    • 2011
  • The vibronically well-resolved emission spectrum was recorded from the corona discharge of precursor 2,3,4-trifluorotoluene in a corona excited supersonic expansion with a pinhole-type glass nozzle using a long-path monochromator in the visible region. From the analysis of the observed spectrum, we found the evidence of the presence of the difluorobenzyl radicals in the corona discharge of the precursor. A possible mechanism is proposed for the formation of difluorobenzyl radicals in the gas phase on the basis of the observed emission intensity of the difluorobenzyl radicals produced.

타원계 엽형기어의 설계 및 동특성에 관한 연구 (Design of Elliptical Lobe Type Gear with Involute Profile)

  • 유명섭
    • 한국정밀공학회지
    • /
    • 제15권4호
    • /
    • pp.7-14
    • /
    • 1998
  • Noncircular gears have been used for obtaining the modified anglualr velocity ratio between parallel axes. The elliptical gear, which is a kind of noncircular gears, makes use of ellipse as a pitch curve, and is applied for the measurement of the discharge of liquid. The applications of an elliptical gear are more advantageous than any other mechanism as like a crank-slider linkage or a cam mechanism in view of the accuracy and the reliability to transmit the prescribed motion. In this paper, acceding to the theoretical involute tooth profile, two pairs of the elliptical gears were manufactured by using CNC wire electronic discharge machine. The proper ranges of the operating pressure angle and of module not to generate under cutting are studied on the change of the eccentricity, because it is the eccentricity of the pitch curve that determines most of the characteristics of the elliptical gear and then the vibration analysis is executed for the verification of harmonious rotating.

  • PDF

Response of estuary flow and sediment transport according to different estuarine dam locations and freshwater discharge intervals

  • Steven Figueroa;Minwoo Son
    • 한국수자원학회:학술대회논문집
    • /
    • 한국수자원학회 2023년도 학술발표회
    • /
    • pp.519-519
    • /
    • 2023
  • Estuarine dams are a recent and global phenomenon. While estuarine dams can provide the benefit of improved freshwater resources, they can also alter estuarine processes. Due to the wide range of estuarine types and estuarine dam configurations, the effect of estuarine dams on estuaries is not well understood in general. To develop a systematic understanding of the effect of estuarine dam location and freshwater discharge interval on a range of estuarine types (strongly stratified, partially mixed, periodically stratified, and well-mixed), this study used a coupled hydrodynamic-sediment dynamic numerical model (COAWST) and compared flow, sediment transport, and morphological conditions in the pre- and post-dam estuaries. For each estuarine type, scenarios with dam locations at 20, 55 and 90 km from the mouth and discharge intervals of a discharge every 0.5, 3, and 7 days were investigated. The results were analyzed in terms of change in tide, river discharge, estuarine classification, and sediment flux mechanism. The estuarine dam location primarily affected the tide-dominated estuaries, and the resonance length was an important length scale affecting the tidal currents and Stokes return flow. When the location was less than the resonance length, the tidal currents and Stokes return flow were most reduced due to the loss of tidal prism, the dead-end channel, and the shift from mixed to standing tides. The discharge interval primarily affected the river-dominated estuaries, and the tidal cycle period was an important time scale. When the interval was greater than the tidal cycle period, notable seaward discharge pulses and freshwater fronts occurred. Dams located near the mouth with large discharge interval differed the most from their pre-dam condition based on the estuarine classification. Greater discharge intervals, associated with large discharge magnitudes, resulted in scour and seaward sediment flux in the river-dominated estuaries, and the dam located near the resonance length resulted in the greatest landward tidal pumping sediment flux and deposition in the tide-dominated estuaries.

  • PDF

대체냉매 공기조화기용 로터리 압축기의 성능향상을 위한 최적 토출계에 관한 실험적 연구 (An Experimental Study on the High Performance Optimal Discharge System of a Rotary Compressor for an Air Conditioner using alternative Refrigerant R410a)

  • 윤영;정진택;민만기
    • 설비공학논문집
    • /
    • 제13권2호
    • /
    • pp.96-105
    • /
    • 2001
  • R410a which is one of HFC refrigerants is being considered to be a promising replacement for R22 widely used in domestic air conditioners. The rolling piston type rotary compressors for R410a have lower energy efficiency than those for R22 because of the high pressure difference between a suction chamber and a discharge chamber in the compression mechanism. in addition, the re-expansion gas loss of the rotary compressor for R410a which occurs a ta clearance volume in a discharge port becomes larger than that for R22 due to high density of R410a refrigerant. Therefore, Pressure-Volume analyses for various design parameters of a discharge system were carried out to improve efficiency of a R410a rotary compressor. The results such as performance dta, over-compression loss, and re-expansion loss were acquired by P-V analyses and analyzed quantitatively. As a conclusion, the optimal specifications of several design parameters of a discharge system were obtained by analyzing P-V diagrams.

  • PDF

Alkyl Group Dissociation During Corona Excitation of Alkylbenzenes

  • Yoon, Young-Wook;Lee, Sang-Kuk
    • 대한화학회지
    • /
    • 제55권5호
    • /
    • pp.741-745
    • /
    • 2011
  • Well-resolved vibronic emission spectra were recorded in the visible region from the corona discharge of precursor alkylbenzenes in a technique of corona excited supersonic expansion using a pinhole-type glass nozzle. From the observed spectra, we found the evidence of the presence of benzyl-type radicals generated by dissociation of C-C or C-H bonds of alkyl group. After identification of benzyl-type radicals formed in the corona discharge, we suggest that energy densities in alkyl chain play a crucial role in determining the bond dissociation during corona excitation.

초고압 $SF_6$가스중의 선구방전기구 (Precursor Discharge Mechanism under EHV in $SF_6$ Gas)

  • 이형호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1996년도 하계학술대회 논문집 C
    • /
    • pp.1807-1809
    • /
    • 1996
  • The axial discharge at switching operations of EHV $SF_6$ disconnector can lead to the breakdown to the enclosure. Precursor in periphery zone leads to formation of leader over some time delay. Injected charge value depends on electric field and gap geometry. The calculation method for parameters of $SF_6$ insulation for DS in EHV-GIS is suggested by using the new criterion of leader inception in connection with periphery field nearby the boundary of streamer zone.

  • PDF

Plasma display panels; problems and their analysis via computer simulations

  • Nagorny, V.P.;Khudik, V.N.;Drallos, P.J.;Shvydky, A.
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2005년도 International Meeting on Information Displayvol.I
    • /
    • pp.155-160
    • /
    • 2005
  • Computer simulations of a pdp discharges provide unique information necessary for their analysis, unavailable otherwise. Statistical instability of the ramp discharge and the role of exoemission, nature of striations during sustain discharge, physical mechanism responsible for the propagation of the cathode ionization wave, and line loading effects are just a few examples when simulations can be successfully used.

  • PDF

가전용 커패시터의 소손원인 규명 및 발열 메커니즘 해석 (Examination of the Cause of Damage to Capacitors for Home Appliances and Analysis of the Heat Generation Mechanism)

  • 박형기;최충석
    • 한국안전학회지
    • /
    • 제26권6호
    • /
    • pp.13-19
    • /
    • 2011
  • The purpose of this study is to examine the cause of damage to electrolytic capacitors and to present the heat generation mechanism in order to prevent the occurrence of similar problems. From the analysis results of electrolytic capacitors collected from accident sites, the fire causing area can be limited to the primary power supply for the initial accident. From the tests performed by applying overvoltage, surge, etc., it is thought that the fuse, varistor, etc., are not directly related to the accidents that occurred. The analysis of the characteristics using a switching regulator showed that the charge and discharge characteristics fell short of standard values. In addition, it is thought that heated electrolytic capacitors caused thermal stress to nearby resistances, elements, etc. It can be seen that the heat generation is governed by the over-ripple current, application of AC overvoltage, surge input, internal temperature increase, defective airtightness, etc. Therefore, when designing an electrolytic capacitor, it is necessary to comprehensively consider the correct polarity arrangement, appropriate voltage application, correct connection of equivalent series resistance(ESR) and equivalent series inductance(SEL), rapid charge and discharge control, sufficient margin of dielectric tangent, etc.

열전지용 황철석(FeS2) 입자크기 변화에 따른 전기화학반응 메커니즘 (Electrochemical Reaction Mechanism with Variation of Pyrite (FeS2) Particle Size for Thermal Battery)

  • 박병준
    • 한국전기전자재료학회논문지
    • /
    • 제30권4호
    • /
    • pp.246-252
    • /
    • 2017
  • Pulverized $FeS_2$ (pyrite) gives different discharge test results with as-received $FeS_2$ electrodes. The as-received $FeS_2$ electrode shows three voltage plateaus during the discharge test. However, the ball-milled $FeS_2$ electrode shows two voltage plateaus. To interpret this result, the effect of $FeS_2$ particle size on electrochemical reactions is investigated by unit cell discharge tests, SEM and XRD. As a result, it is found that the transition reaction product ($Li_2+xFe+xS_2$) of $FeS_2$ explains the difference. The as-received $FeS_2$ reacts according to three reaction steps ($FeS_2{\rightarrow}Li_3Fe_2S_4{\rightarrow}Li_2+xFe_1+xS_2{\rightarrow}LiFe_2S_4$). However, ball-milled $FeS_2$ reacts without the $Li_2+xFe_1+xS_2$ stage. In this study, this result is explained by the difference in electrochemical reaction mechanism. The as-received $FeS_2$ has a larger radius than the ball-milled $FeS_2$. Therefore, the lithium ion has to diffuse into the $FeS_2$ unreacted core, and $Li_2+xFe_1+xS_2$, the transition reaction product of as-received $FeS_2$, is formed during this stage.