• Title/Summary/Keyword: Discharge Measurements

Search Result 398, Processing Time 0.031 seconds

Application of EFDC and WASP7 in Series for Water Quality Modeling of the Yongdam Lake, Korea

  • Seo, Dong-Il;Kim, Min-Ae
    • Journal of Korea Water Resources Association
    • /
    • v.44 no.6
    • /
    • pp.439-447
    • /
    • 2011
  • This study aims to test the feasibility of combined use of EFDC (Environmental Fluid Dynamics Code) hydrodynamic model and WASP7.3 (Water Quality Analysis Program) model to improve accuracy of water quality predictions of the Yongdam Lake, Korea. The orthogonal curvilinear grid system was used for EFDC model to represent riverine shape of the study area. Relationship between volume, surface and elevation results were checked to verify if the grid system represents morphology of the lake properly. Monthly average boundary water quality conditions were estimated using the monthly monitored water quality data from Korean Ministry of Environment DB system. Monthly tributary flow rates were back-routed using dam discharge data and allocated in proportion to each basin area as direct measurements were not available. The optimum number of grid system was determined to be 372 horizontal cells and 10 vertical layers of the site for 1 year simulation of hydrodynamics and water quality out of iterative trials. Monthly observed BOD, TN, TP and Chl-a concentrations inside the lake were used for calibration of WASP7.3 model. This study shows that EFDC and WASP can be used in series successfully to improve accuracy in water quality modeling. However, it was observed that the amount of data to develop inflow water quality and flow rate boundary conditions and water quality data inside lake for calibration were not enough for accurate modeling. It is suggested that object-oriented data collection systems would be necessary to ensure accuracy of EFDC-WASP model application and thus for efficient lake water quality management strategy development.

A Study on the Structural and Electrochemical Properties of Li0.99Ni0.46Mn1.56O4 Cathode Material Using Synchrotron based in-situ X-ray Diffraction

  • Choi, Sol;Yoon, JeongBae;Muhammad, Shoaib;Yoon, Won-Sub
    • Journal of Electrochemical Science and Technology
    • /
    • v.4 no.1
    • /
    • pp.34-40
    • /
    • 2013
  • The structural and electrochemical properties of $Li_{0.99}Ni_{0.46}Mn_{1.56}O_4$ ($Fd{\bar{3}}m$, disordered spinel) cathode material were studied and compared with stoichiometric $LiNi_{0.5}Mn_{1.5}O_4$ ($P4_332$, ordered spinel). First cycle discharge capacity of $Li_{0.99}Ni_{0.46}Mn_{1.56}O_4$ was similar to that of $LiNi_{0.5}Mn_{1.5}O_4$ at C/3 and 1C rate, but cycling performance of $Li_{0.99}Ni_{0.46}Mn_{1.56}O_4$ was better than that of $LiNi_{0.5}Mn_{1.5}O_4$ especially at high rate of 1C. This can be explained by performing synchrotron based in-situ XRD and results of GITT measurements. It is considered that faster lithium ion diffusion in the $Li_{0.99}Ni_{0.46}Mn_{1.56}O_4$ cathode results in the improvement of the rate capability. To study structural changes during cycling, synchrotron in-situ XRD patterns of both the samples were recorded at C/3 and 1C rate. Compared to stoichiometric $LiNi_{0.5}Mn_{1.5}O_4$, disordered $Li_{0.99}Ni_{0.46}Mn_{1.56}O_4$ spinel sample has pseudo one phase behavior and one step phase transition between two cubic phases. So, $LiNi_{0.5}Mn_{1.5}O_4$ would experience a much greater strain and stress, originating from the two phase transitions between three cubic phases and suffer from capacity loss during cycling especially at high rate.

Electrochemical Performance of AlF3-Coated LiV3O8 for Aqueous Rechargeable Lithium Ion Batteries

  • Tron, Artur;Kang, Hyunchul;Kim, Jinho;Mun, Junyoung
    • Journal of Electrochemical Science and Technology
    • /
    • v.9 no.1
    • /
    • pp.60-68
    • /
    • 2018
  • In aqueous rechargeable lithium ion batteries, $LiV_3O_8$ exhibits obviously enhanced electrochemical performance after $AlF_3$ surface modification owing to improved surface stability to fragile aqueous electrolyte. The cycle life of $LiV_3O_8$ is significantly enhanced by the presence of an $AlF_3$ coating at an optimal content of 1 wt.%. The results of powder X-ray diffraction, energy dispersive X-ray spectroscopy, X-ray photoelectron spectroscopy, inductively coupled plasma-optical emission spectrometry, and galvanostatic charge-discharge measurements confirm that the electrochemical improvement can be attributed mainly to the presence of $AlF_3$ on the surface of $LiV_3O_8$. Furthermore, the $AlF_3$ coating significantly reduces vanadium ion dissolution and surface failure by stabilizing the surface of the $LiV_3O_8$ in an aqueous electrolyte solution. The results suggest that the $AlF_3$ coating can prevent the formation of unfavorable side reaction components and facilitate lithium ion diffusion, leading to reduced surface resistance and improved surface stability compared to bare $LiV_3O_8$ and affording enhanced electrochemical performance in aqueous electrolyte solutions.

Water Hammer in the Pump Pipeline System with an Air Chamber (에어챔버가 설치된 가압펌프 계통에서의 수격현상)

  • Kim, Sang-Gyun;Lee, Kye-Bock
    • Journal of Energy Engineering
    • /
    • v.16 no.4
    • /
    • pp.187-193
    • /
    • 2007
  • Water hammer following the tripping of pumps can lead to overpressures and negative pressures. Reduction in overpressure and negative pressure may be necessary to avoid failure, to improve the efficiency of operation and to avoid fatigue of system components. The field tests on the water hammer have been conducted on the pump rising pipeline system with an air chamber. The hydraulic transient is modeled using the method of characteristics. Minimizing the least squares problem representing the difference between the measured and predicted transient response in the system performs the calibration of the simulation program. Among the input variables used in the water hammer analysis, the effects of the polytropic exponent, the discharge coefficient and the wave speed on the result of the numerical analysis were examined. The computer program developed in this study will be useful in designing the optimum parameters of an air chamber for the real pump pipeline system. The correct selection of air chamber size and the effects of related parameters to minimize water hammer have been investigated by both field measurements and numerical modeling.

Experiments on granular flow in a hexagonal silo: a design that minimizes dynamic stresses

  • Hernandez-Cordero, Juan;Zenit, R.;Geffroy, E.;Mena, B.;Huilgol, R.R.
    • Korea-Australia Rheology Journal
    • /
    • v.12 no.1
    • /
    • pp.55-67
    • /
    • 2000
  • In this paper, an experimental study of the rheological behavior of granular flow in a new type of storage silo is presented. The main characteristic of the new design is a hexagonal shape chosen with the objective of minimizing the stresses applied to the stored grains, and to reduce grain damage during the filling and emptying processes. Measurements of stress distribution and flow patterns are shown for a variety of granular materials. Because of the design of the silo, the granular material adopts its natural rest angle at all times eliminating collisional stresses and impacts between grains. A homogeneous, low friction flow is naturally achieved which provides a controlled stress distribution throughout the silo during filling and emptying. Secondary dynamic stresses, which are responsible for wall failure in conventional silos of the vertical type, are completely eliminated. A comparison between the two geometries is presented with data obtained for these silos and a number of granular materials. The discharge pattern inhibits powder formation in the silo and the filling system virtually eliminates unwanted material packing. Finally, notwithstanding the rheological advantages of this new design, the hexagonal cells that constitute the silo have many other advantages, such as the possible use of solar energy to control the humidity inside them. The cell type design allows for versatile storage capabilities and the elevation above the ground provides unlimited transportation facilities during emptying.

  • PDF

Synthesis and electrochemical performance of transition metal-coated carbon nanofibers as anode materials for lithium secondary batteries

  • Choi, Jin-Yeong;Hyun, Yura;Park, Heai-Ku;Lee, Chang-Seop
    • Journal of Industrial and Engineering Chemistry
    • /
    • v.68
    • /
    • pp.161-167
    • /
    • 2018
  • In this study, transition metal coated carbon nanofibers (CNFs) were synthesized and applied as anode materials of Li secondary batteries. CNFs/Ni foam was immersed into 0.01 M transition metal solutions after growing CNFs on Ni foam via chemical vapor deposition (CVD) method. Transition metal coated CNFs/Ni foam was dried in an oven at $80^{\circ}C$. Morphologies, compositions, and crystal quality of CNFs-transition metal composites were characterized by scanning electron microscopy (SEM), Raman spectroscopy (Raman), and X-ray photoelectron spectroscopy (XPS), respectively. Electrochemical characteristics of CNFs-transition metal composites as anodes of Li secondary batteries were investigated using a three-electrode cell. Transition metal/CNFs/Ni foam was directly employed as a working electrode without any binder. Lithium foil was used as both counter and reference electrodes while 1 M $LiClO_4$ was employed as the electrolyte after it was dissolved in a mixture of propylene carbonate:ethylene carbonate (PC:EC) at 1:1 volume ratio. Galvanostatic charge/discharge cycling and cyclic voltammetry measurements were taken at room temperature using a battery tester. In particular, the capacity of the synthesized CNFs-Fe was improved compared to that of CNFs. After 30 cycles, the capacity of CNFs-Fe was increased by 78%. Among four transition metals of Fe, Cu, Co and Ni coated on carbon nanofibers, the retention rate of CNFs-Fe was the highest at 41%. The initial capacity of CNFs-Fe with 670 mAh/g was reduced to 275 mAh/g after 30 cycles.

The Analysis of Flood in an Ungauged Watershed using Remotely Sensed and Geospatial Datasets (II) - Focus on Estimation of Flood Inundation - (원격탐사와 공간정보를 활용한 미계측 유역 홍수범람 해석에 관한 연구(II) - 침수 피해면적 산정을 중심으로 -)

  • Son, Ahlong;Kim, Jongpil
    • Korean Journal of Remote Sensing
    • /
    • v.35 no.5_2
    • /
    • pp.797-808
    • /
    • 2019
  • This study evaluated the applicability of spacebourne datasets to the flood analysis in an ungauged watershed where is no discharge measurements. The Duman River basin of North Korea was selected as a target area which was flooded by recent Typhoon Lionrock. Topographical parameters for flood analysis were estimated from the Advanced Spaceborne Thermal Emission and Reflection Radiometer (ASTER) Global Digital Elevation Model (GDEM). GDEM includes the shortcomings of information on river cross-section, and conducted 2 dimensional flood analysis when considering virtual river cross-section and not considering it. As a result of comparative analysis, an error occurs in the inundation area and depth, but when used carefully, it is considered that the satellite image can be used for creating flood hazard map and utilizing information for response and preparation.

Calculation of mean velocity and Discharge Method using Water Surface Velocity Measurements (표면유속측정을 통한 평균유속과 유량산정 방법)

  • Lim, Hyeok Jin;Seol, Myoung Soo;Jung, Moon Soo;Kim, Sam Eun;Kim, Chi Young
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2017.05a
    • /
    • pp.503-503
    • /
    • 2017
  • 대부분의 자연하천에서 유량조사는 하천 횡단면의 유속을 측정하여 수위-유량관계로부터 유량을 산정하고 있다. 유속의 측정은 통상적으로 횡단면을 일정 구간으로 구분하여 회전식, 전자식 유속계, 부자 등과 같은 접촉식 장비를 이용하여 일차원 유속으로부터 구간을 대표하는 평균유속을 기반으로 유량을 산정하고 있다. 그러나 이런 접촉식 장비를 통한 유속 측정은 인력, 장비, 비용 및 돌발 호우사상의 측정자의 안전 등 현장 조건의 한계로 관측자료를 확보하지 못 하는 미측정 영역이 발생한다. 이에 따라 수위와 유량측정성과로 개발된 수위-유량관계곡선식은 미측정 구간인 외삽구간에서 정확도가 낮은 유량자료가 산정될 수 있다. 이에 따라 본 연구에서는 하천 횡단면의 일부 고정된 지점에서 측정된 표면유속을 이용하여 유량규모에 따른 평균유속의 상관관계를 분석하고 수위-유량관계곡선으로 산정된 유량과 비교함으로써 비접촉식 유속 측정방식을 통한 유량산정의 활용성과 적용성을 검토하였다. 이를 통해 표면유속을 활용한 유량산정의 실무적인 방법론을 제시하고 고수위 외삽구간의 유량을 비교 및 검증하였으며 수위 1.23m 이상에서 표면유속(0.62m/s ~ 2.69m/s)과 평균유속의 관계는 구간별로 일정한 선형관계가 나타났으며 각 구간에 대한 상관계수는 $R^2=0.97$ 이상으로 높게 나타났다. 이상의 결과는 비접촉식 표면유속측정으로 홍수기 중고수위 이상에서 접촉식 유속계가 갖는 한계를 보완하여 연속적인 유량생산이 가능하고 개발된 수위-유량관계곡선식의 외삽구간을 검토할 수 있는 참고자료를 획득하여 고수위 유량자료의 신뢰성을 높일 수 있는 것으로 판단된다.

  • PDF

The Jet-fan Model Test for a Road Tunnel Ventilation (도로터널 제트팬 모형 실험)

  • Ryu, Jae-Hong;Yoo, Young-Ho;Kim, Jin
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.15 no.8
    • /
    • pp.630-640
    • /
    • 2003
  • As tunnel ventilation has recently been playing a major role in the tunnel construction and maintenance, longitudinal ventilation systems with jet fans have been utilized a great deal because they are economical and effective. However, due to the length of tunnels and heavy traffic, it is hard to take the field measurements. In this study, therefore, the computer simulation and the model experiment of producing a wind tunnel were carried out simultaneously and the results were compared. The ultimate objective of this research was to interpret the air flow pattern inside the tunnel with a jet-fan was set up, and to offer the useful data for jet-fan installation and operation. The experiment was carried out with varying the jet-fan diameters, location of installation, the discharge velocity. Result showed that as the initial static pressure came up with the negative pressure, the tunnel air flowed into the inside of tunnel from outside due to the entrainment-effect and the backflow-phenomenon by separation-effect was observed in the lower half part of the tunnel. As the jet-fan was getting closer to the tunnel wall, the entrainment-effect caused by the interaction with the wall was increased; however, the mixing distance and irregular flow section became longer, and also the air pressure loss generated by wall friction was large.

Radiation Safety Exploration Using Radio-photoluminescence Dosimeter for Crookes Tubes in Junior and Senior High School in Japan

  • Akiyoshi, Masafumi;Do, Duy Khiem;Yamaguchi, Ichiro;Kakefu, Tomohisa;Miyakawa, Toshiharu
    • Journal of Radiation Protection and Research
    • /
    • v.46 no.3
    • /
    • pp.106-111
    • /
    • 2021
  • Background: Crookes tube is utilized in junior high and high schools in Japan to study the character of electrons and current, and not for radiological education. There is no official guideline or regulation for these radiation source to the public. Therefore, most teachers have no information about the leakage of X-rays from Crookes tube. The peak energy of X-rays is approximately 20 keV, and it is impossible to measure using conventional survey meters. Materials and Methods: Each leakage dose of low energy X-rays from 38 Crookes tube in the education field, such as junior and senior high schools in Japan, was explored by the teachers in the school using radio-photoluminescence (RPL) dosimeters. Before and after the measurements, the dosimeters were sent by postal mails. Results and Discussion: At the exploration in this study, it was estimated that the 70 ㎛ dose equivalent, Hp(0.07) of X-rays from 31 Crookes tubes were smaller than 100 µSv in 10 minutes, at the distance of 1 m, where the Crookes tube was usually observed. However, the highest dose was estimated as 0.69 mSv by an equipment with the full power. Furthermore, one Crookes tube exhibited 0.62 mSv with minimum output power of the induction coil. This relatively large dose was reduced by the shorter distance of discharge electrodes of the induction coil. Conclusion: The leakage dose of low energy X-rays from 38 Crookes tube was explored using RPL dosimeters. It was estimated that the Hp(0.07) of X-rays from 31 Crookes tubes were smaller than 100 µSv in 10 minutes at the distance of 1 m, while some equipment radiated a higher dose. With this study, the provisional guideline for the safety operation of Crookes tube is established.