• 제목/요약/키워드: Discharge Measurements

검색결과 396건 처리시간 0.02초

An Efficient Method Of The Suspended Sediment-Discharge Measurement Using Entropy Concept

  • Choo, Tai-Ho
    • Water Engineering Research
    • /
    • 제1권2호
    • /
    • pp.95-105
    • /
    • 2000
  • A method is presented which enables easily the computation of the suspended sediment discharge as the mean sediment concentration and mean flow velocity. This method has significant advantages over the traditional method, which principally depend on a set of measured concentration data. The method is based on both a new sediment concentration and mean sediment concentration equations which have been derived from the entropy concept used in statistical mechanics and information theory: (1) The sediment concentration distribution equations derived, are capable of describing the variation of the concentration in the vertical direction. (2) The mean concentration equation derived, is capable of calculating easily the mean concentration by using only one measured concentration in open channel. The present study mainly addresses the following two subjects : (1) new sediment concentration and mean sediment concentration equations are derived from the entropy concept : (2) An efficient and useful method of suspended sediment-discharge measurements is developed which can facilitate the estimation of suspended sediment-discharge in open channel. Flume and laboratory data are used to carry out the research task outlined above. An efficient method for determining the suspended sediment-discharge in the open channel has been developed. The method presented also is efficient and applicable in estimating the sediment transport in rivers and the sediment deposit in the reservoirs, and can drastically reduce the time and cost of sediment measurements.

  • PDF

다양한 유량 측정기기와 ADCP를 이용한 유량 비교 분석 (Analysis and Comparison of Flow Rate Measurements Using Various Discharge Measuring Instrument and ADCP)

  • 지주연;박승용;이광우;박경민;황순홍;김동호;이영준
    • 한국환경과학회지
    • /
    • 제22권2호
    • /
    • pp.251-257
    • /
    • 2013
  • Discharge data examine the process of hydrologic cycle and used significantly in water resource planning and irrigation and flood control planning. It makes high quality discharge data, they carry out research on standard and method of discharge measurement, and equipment improvement. Now various flow meters are utilized to make discharge data in Korea. However, accuracy of equipment and exprerimental research data from measurement are not enough. ADCP(Acoustic Doppler Current Profiler) have been introduced and utilized for flow measurements since the end of 1980's. ADCP flow method is a formal method for flow measurement can easily applyd to relatively large rivers gradually recognized. This equipment can measure the non-contact three-dimensional velocity and water depth data very quickly and efficiently. Also, spatial and temporal resolution of the data is more accurate than any other flow measurement methods which measure flow rate by velocity - area measurement method. In this paper, the velocity is measured using various flow meter and verified the effectiveness by applying from the ADCP in Geum-river. Various flow meters which are med for discharge measurements are VALEPORT002, FLOW TRACKER, PRICE AA and ADCP. The average of five times flow measurement result by ADCP was $10.412m^3/s$, with a standard deviation of 0.68. The repeat test by ADCP and comparison between ADCP and other flow devices to verify the most import factor, flow measurement accuracy. In the result, repeat test of the ADCP showed similar values, flow values were similar to other velocity device results and the average error is 7.7%.

자동유량측정에 의한 한강대교 조석영향 분석 (Analysis of Tidal Effect in Hangang Bridge by Automatic Discharge Measurement)

  • 이민호;김창완;유동훈
    • 한국수자원학회논문집
    • /
    • 제42권7호
    • /
    • pp.513-523
    • /
    • 2009
  • 한강대교지점은 조석의 영향을 받고 노들섬으로 인해 흐름이 나누어지는 특수한 지형조건을 가지고 있으며, 홍수예보지점이고 한강유역의 유출량을 분석하는 대표지점이기도 하다. 따라서 정확한 수위-유량관계를 도출하기 위하여 많은 노력을 기울였으나 조석의 영향을 받지 않는 홍수기 이외의 기간에 대한 정확도의 확보가 곤란하였다. 이러한 문제를 해결하기 위한 대책으로 최근 자동유량측정에 관한 연구가 진행되었고, 실무에 적용되어 한강대교지점에서 실시간 유량자료의 획득이 가능하게 되었다. 한강대교지점에는 남단(노량진방향)과 북단(용산방향)에 2대의 자동유량측정 시설을 설치하여 운영하고 있다. 수중에 설치된 도플러방식 수평초음파유속계(H-ADCP)가 23개 각도로 회전하며 10분마다 단면의 유속자료를 생산하고, Chiu의 유속분포(Chiu, 1988)를 이용하여 유량을 계산한다. 본 고에서는 자동으로 측정된 성과와 기존의 유량측정 방법에 의한 성과를 비교하였으며, 월별 유출량에 대한 분석결과를 제시하였다.

Laser Thomson Scattering Measurements and Modelling on the Electron Behavior in a Magnetic Neutral Loop Discharge Plasma

  • Sung, Youl-Moon;Kim, Hee-Je;Park, Chung-Hoo
    • KIEE International Transactions on Electrophysics and Applications
    • /
    • 제11C권4호
    • /
    • pp.107-112
    • /
    • 2001
  • Laser Thomson scattering measurements of electrom temperature and density in a neutral loop discharge (NLD) plasma were performed in order to reveal the electron behavior around the neutral loop (NL). The experimental results were examined by using a simulation model that included effects of a three dimensional electromagnetic field with spatial decay of the RF electric field, and the limitation of the spatial extent of the electron motion and collision effect. From the experiments and modeling of the electron behavior, it was found that NLD plasma posses the electron temeprature $T_{e}$ and density ne peaks around the NL is essential for the formation of plasma. Also, the optimum condition of plasma production could be simply estimated by the calculation of $U_{av}$ and $F_{0}$././.

  • PDF

고성능 유압 베인펌프 개발을 위한 내부 변동압력 측정 (I) (Tne Measurements of internal Dynamic Pressure for Development of a High Performance Oil hydraulic Vane Pump(I))

  • 정재연;정석훈
    • 대한기계학회논문집
    • /
    • 제16권2호
    • /
    • pp.191-199
    • /
    • 1992
  • This paper presents in experimental study of the dynamic internal pressure within an oil hydraulic vane pump. The measurements of the dynamic internal pressures near the vane of a pressure balance type of an oil hydraulic vane pump with intravanes has been made to provide the essential information for the study of the pump dynamics and control, the pump design and the analysis of tribological problems in the sliding components. The influences of the discharge pressure and rotating speed of the vane on the dynamic pressure in four chambers surrounding a vane have been investigated. The results indicate that the surge pressures of the chambers at the instant moment of discharge and closure are affected by the rotating speed. The pressure in the intravane chamber maintains almost constant values, which remarkably effects the pulsating discharge pressure.

Assessment of 23 kV Capacitive Coupler for On-line Partial Discharge Measurements

  • Jeong, J.Y.;Kang, D.S.;Sun, J.H.;Heo, J.C.;Park, C.H.
    • Journal of Electrical Engineering and Technology
    • /
    • 제4권1호
    • /
    • pp.123-130
    • /
    • 2009
  • The partial discharge (PD) measurement is a very effective method to assess the winding insulation condition of high-voltage machines, since most of the insulation failure processes are directly or indirectly caused by PD. On-line PD measurements, which can detect insulation defects of winding in the early stages on rotating machines in operation, have been accepted as the most important technique. The epoxy mica capacitive coupler is currently and extensively used for on-line detection of PD pulses of high-voltage rotating machines. To evaluate the feasibility of developing a capacitive coupler that is easier to manufacture at a lower cost compared to epoxy mica couplers, a 100pF capacitive coupler made of ceramic material is designed, fabricated and tested for on-line PD measurements of 23 kV electrical machines. A series of electrical tests and accelerated aging tests are performed on the ceramic coupler to evaluate the performance requirements, long-term reliability and thermal stability for in field application. The test results show that the newly developed ceramic coupler provides equal and improved performance at a lower cost compared to epoxy mica couplers, and estimated voltage life is anticipated to surpass 100 years.

양산천 수위-유량관계 특성에 관한 현장관측 분석 (Analysis of Field Observations on Characteristics of Stage-Discharge Relationshiup for Yangsan River)

  • 이용희;이상배
    • 한국항만학회지
    • /
    • 제14권1호
    • /
    • pp.107-114
    • /
    • 2000
  • Derivation of stage-discharge relationship and characteristics for Yangsan river is presented in this paper. This research has been conducted as the second one after the first trial in 1997. The determination of discharge at a Yangsan river gauging was best made by measuring the flow velocities with a current meter and rod float. The rating curve obtained through 52 stage-discharge measurements on Yangsan river basin in 1999 is represented by Q=15.3540-140.6076H+182.44372H$^2$, which is discovered to be most excellent among other curves in reliability analysis. The observed stage-discharge data for Yangsan river was tested by HEC-RAS program, and reproduction of discharge by the induced curve was investigated and compared with the computational results. The rating curve of Yangsan river shows characteristics of Yangsan river more accurately compared with those separated in terms of water levels.

  • PDF

송출공의 회전이 송출계수와 압력계수에 미치는 영향 (The Effect of Rotation of Discharge Hole on the Discharge Coefficient and Pressure Coefficient)

  • 하경표;구남희;고상근
    • 대한기계학회논문집B
    • /
    • 제27권7호
    • /
    • pp.948-955
    • /
    • 2003
  • Pressure coefficient in rotating discharge hole was measured to gain insight into the influence of rotation to the discharge characteristics of rotating discharge hole. Pressure measurements were done by the telemetry system that had been developed by the authors. The telemetry system measures static pressure using piezoresistive pressure sensors. Pressure coefficients in rotating discharge hole were measured in longitudinal direction and circumferential direction with various rotating speed and 3 pressure ratios. From the results, the pressure coefficient, and therefore the discharge coefficient, is known to decrease with the increase of Ro number owing to the increase of flow approaching angle to the discharge hole inlet. However, there exists critical Ro number where the decrease rate of discharge coefficient with the increase of Ro number changes abruptly; flow separation occurs from the discharge hole exit at this critical Ro number. Critical Ro number increases with the increase of length-to-diameter ratio, but the increase is small where the length-to-diameter ratio is higher than 3. The decrease rate of discharge coefficient with the increase of Ro number depends on the pressure recovery at the discharge hole, and the rate is different from each length-to-diameter ratio; it has tendency that the short discharge hole shows higher decrease rate of discharge coefficient.

고압전동기 고정자 권선의 PRPD 부분방전 결함신호 해석 (Analysis on Partial Discharge Fault Signals of PRPD for High Voltage Motor Stator Winding)

  • 박재준;이성룡;문대철
    • 한국전기전자재료학회논문지
    • /
    • 제19권10호
    • /
    • pp.942-946
    • /
    • 2006
  • We simulated insulation defects of stator winding wire on high voltage generator by 5 types. 4 types have one discharge source and other one has multi discharge source by simulation. For accurate decision, measurements used to PRPD pattern to occurred partial discharge source of various types. In this research, when PRPD pattern carried out or analyzed pattern recognition of discharge source, it used to powerful tools. In this result, PRPD Pattern defined to have single discharge source of 4 types by insulation defect. When insulation defect simulated, all the defected winding have not the same result. Errors for a little different can make mistakes from a subtle distinction. The difference between internal and void discharge have magnitude of pulse amplitude of inner discharge bigger than void discharge and have a shape of bisymmetry. But void discharge has a shape of bisymmetry against maximum value on polarity respectively. In cases of slot and surface discharge, we confirmed to show similar results those other researchers. In case of multi-discharge, as a result of we could classify not perfect match with occurred patterns in single discharge eachother. In the future, we will have to recognize and classify with results of multi-discharge.

GIS 내 금속입자의 부상전압과 부분방전특성 연구 (Lift-Off Voltage and Partial Discharge Characteristics of Free Metallic Particles in GIS)

  • 윤진열;한상옥
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제48권2호
    • /
    • pp.127-132
    • /
    • 1999
  • Both motion of free metallic particles from which most GIS internal failures are caused and partial discharges from the particles were examined using EHV GIS test chamber. Effects from particle length and gas pressure which are main factors to lead to breakdown failure were investigated theoretically and experimentally. Magnitude of both lift-off voltage and partial discharge inception voltage were measured respectively and, through these measurements, this paper showed the possibility of predicting breakdown fault and of taking action to prevent the fault in advance. The measurement of partial discharge when the particles began to move could be adopted to decide minimum sensitivity in developing predictive diagnostic equipments. Both the amount of apparent discharge and real discharge in GIS were examined theoretically and experimentally, then experimental results were analyzed on the basis of the theory.

  • PDF