• 제목/요약/키워드: Discharge Flow-rate

검색결과 755건 처리시간 0.022초

고주파전원형 오존발생기의 방전 캡 변화 특성 (Characteristics of Ozonizer with Variation of Vaccum in Internal Electrode)

  • 이창호;전병준;이상근;송현직;이광식
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2003년도 학술대회논문집
    • /
    • pp.381-385
    • /
    • 2003
  • In this paper, a co-axial type ozonizer varied with discharge gap was designed and manufactured for investigating $\circled1$ discharge characteristics with variation of output voltage power supply, flow rate and gap $\circled2$ ozone generation characteristics with variation of flow rate, gap and discharge power. pure oxygen was used as process gas of the co-axial type ozonizer. In this paper, a double cylindrical type superposed silent discharge type ozonizer which internal electrode can be produced a vacuum has been designed and manufactured. Discharge and ozone generation characteristics have been investigated in accordance with output voltage of power supply, flow-rate, discharge power and vacuum of internal electrode.

  • PDF

송출공의 회전이 송출계수와 압력계수에 미치는 영향 (The Effect of Rotation of Discharge Hole on the Discharge Coefficient and Pressure Coefficient)

  • 하경표;구남희;고상근
    • 대한기계학회논문집B
    • /
    • 제27권7호
    • /
    • pp.948-955
    • /
    • 2003
  • Pressure coefficient in rotating discharge hole was measured to gain insight into the influence of rotation to the discharge characteristics of rotating discharge hole. Pressure measurements were done by the telemetry system that had been developed by the authors. The telemetry system measures static pressure using piezoresistive pressure sensors. Pressure coefficients in rotating discharge hole were measured in longitudinal direction and circumferential direction with various rotating speed and 3 pressure ratios. From the results, the pressure coefficient, and therefore the discharge coefficient, is known to decrease with the increase of Ro number owing to the increase of flow approaching angle to the discharge hole inlet. However, there exists critical Ro number where the decrease rate of discharge coefficient with the increase of Ro number changes abruptly; flow separation occurs from the discharge hole exit at this critical Ro number. Critical Ro number increases with the increase of length-to-diameter ratio, but the increase is small where the length-to-diameter ratio is higher than 3. The decrease rate of discharge coefficient with the increase of Ro number depends on the pressure recovery at the discharge hole, and the rate is different from each length-to-diameter ratio; it has tendency that the short discharge hole shows higher decrease rate of discharge coefficient.

수면경사를 반영한 하천 유량산정에 관한 연구 (A Study on Development of Estimation for Discharge Rate Reflecting Water Surface Slope)

  • 추태호;홍순헌;박상진;김영환
    • 한국콘텐츠학회논문지
    • /
    • 제17권2호
    • /
    • pp.535-542
    • /
    • 2017
  • 우리나라는 갈수기와 홍수기의 유량차이가 극심하여 수자원 관리에 대한 중요성이 대두되고 있는 실정이다. 하천의 특성을 파악하기 위해 정확한 유량을 산정해야 한다. 유량을 산정하기 위해서는 유량을 구하고자 하는 하도의 단면적을 산정하고, 해당 단면에서의 유속을 측정해 연속방정식을 이용하여 유량을 산출해야 한다. 보편적으로 수위-유량관계식으로부터 유량을 산정하지만, 이 경우에는 동일한 수심 동일한 유량만을 산출할 수밖에 없다는 단점이 있다. 그래서 본 연구에서는 낙동강 교량 강창교 지점의 성서관측소의 수심과 ADVM를 이용하여 측정된 수심을 이용한 수면경사와 ADVM지점의 수심을 이용하여 유량산정식을 개발하였다. 자연하천의 흐름은 정류나 등류가 아닌 부정류 흐름이기 때문에 하상경사가 아닌 수면경사를 반영하고자 본 연구에서는 두 지점의 측정된 수심으로부터 손쉽게 유량을 산정하는 방법을 제안하였다.

수처리용 유전체장벽 플라즈마 반응기에 대한 기초 연구 (A Basic Study of Plasma Reactor of Dielectric Barrier Discharge for the Water Treatment)

  • 김동석;박영식
    • 한국환경과학회지
    • /
    • 제20권5호
    • /
    • pp.623-630
    • /
    • 2011
  • This study investigated the degradation of N, N-Dimethyl-4-nitrosoaniline (RNO, indicator of the generation of OH radical) by using dielectric barrier discharge (DBD) plasma. The DBD plasma reactor of this study consisted of a quartz dielectric tube, titanium discharge (inner) and ground (outer) electrode. The effect of shape (rod, spring and pipe) of ground electrode, diameter (9~30 mm) of ground electrode of spring shape and inside diameter (4~13 mm) of quartz tube, electrode diameter (1~4 mm), electrode materials (SUS, Ti, iron, Cu and W), height difference of discharge and ground electrode (1~15.5 cm) and gas flow rate (1~7 L/min) were evaluated. The experimental results showed that shape of ground electrode and materials of ground and discharge electrode were not influenced the RNO degradation. The thinner the diameter of discharge and ground electrode, the higher RNO degradation rate observed. The effect of height gap of discharge between ground electrode on RNO degradation was not high within the experimented value. Among the experimented parameters, inside diameter of quartz tube and gas flow rate were most important parameters which are influenced the decomposition of RNO. Optimum inside diameter of quartz tube and gas flow rate were 7 mm and 4 L/min, respectively.

Study on Flow Analysis of Three-Dimensional Screw Propeller With Respect to Rotational Speed Variable

  • Moon, Byung-Young;Sun, Min-Young;Lee, Ki-Yeol
    • 한국해양공학회지
    • /
    • 제28권6호
    • /
    • pp.500-507
    • /
    • 2014
  • This study aimed at conducting a flow analysis of the pressure distribution, discharge flow rate, and consequent thrust force according to the rotational speed of a three-dimensional screw propeller, and then investigating the effect of the rotational speed on the characteristics of the screw propeller by varying the relevant speed (3200, 2400, 1600, 800 rpm). In particular, the computational domain was considered by the analysis in the blades and outlet chamber, using boundary conditions. The difference between the minimum and maximum pressures was 5.5 MPa under the given conditions. The discharge flow rate at this pressure difference was on the level of 1956.67 kg/s, as a thrust force of 47083.7 T(N) was obtained. This study showed that the discharge flow rate linearly increased with the rotational speed, proportional to the RPM, while the thrust force was gradually and steadily increased with the relevant speed. In addition, it was proved that the occurrence of cavitation under the given conditions was closely related to the decrease in the durability of the screw propeller because the thrust force depends on the speed.

차압식 유량계에서 점탄성유체의 유출 및 손실계수 (Discharge and loss coefficients for viscoelastic fluids in differential pressure flow meters)

  • 전우청;조병수;백병준;박복춘
    • 대한기계학회논문집B
    • /
    • 제20권4호
    • /
    • pp.1501-1509
    • /
    • 1996
  • Differential pressure devices such as an orifice and Venturi are widely used in the measurement of flow rate of fluid mainly due to cost effectiveness and easy installation. In the current study, the viscoelastic effect on discharge and loss coefficients of those flow meters were investigated experimentally. Aqueous solutions of Polyacrylamide (200, 500, and 800 ppm) as viscoelastic fluids were used. Discharge coefficient of an orifice for viscoelastic fluids increased significantly up to approximately 15-20% when compared with that for water, while loss coefficient decreased up to 10-25% depending on the diameter ratio, .betha.. Also, pressure recovery for viscoelastic fluids was extended much longer than that for water. On the other hand, discharge and loss coefficients of Venturi for viscoelastic fluids were found to be strongly dependent on the Reynolds number. In both flow meters, the concentration effect for discharge and loss coefficients was not observed at more over than 200 ppm of aqueous solution. Conclusively, orifice and Venturi flow meters should be calibrated very carefully in the flow rate measurement for viscoelastic fluids.

Analytical Application of Glow Discharge Atomic Absorption Spectroscopy (GD-AAS) Using Three Types of Jet Configurations Under Power Mode

  • Hwang, Jun Ho;Lee, Ki Beom;Kim, Min Su;Lee, Seong Ro;Kim, Hasuck;Kim, Hyo Jin;Lee, Gae Ho
    • 분석과학
    • /
    • 제8권4호
    • /
    • pp.443-448
    • /
    • 1995
  • Three anode configurations of six-jet, cone-jet and cylindrical-jet are tested for their analytical performance under power mode operation. The effect of pressure, power and gas flow rate on atomic absorption signals have been studied. The increase of atomic absorption signal of sample element is observed at a fixed pressure in all configurations as the gas flow rate increase up to 300-600 seem, and as the power dissipated in the glow discharge cell increase. The lower the pressure is in the glow discharge cell at a fixed discharge power and argon flow rate, the greater the absorbance of sample element is. The optimum conditions are taken from these data and a calibration curve of Cu in low-alloy steel sample is obtained. In this calibration curve, six-jet configuration shows the best analytical results varies as the sample element.

  • PDF

다수의 취출구를 갖는 A/C덕트의 최적설계에 관한 연구 (A Study on the Optimum Design of Air-Conditioning Duct with Multiple Diffusers)

  • 김민호;이대훈
    • 한국자동차공학회논문집
    • /
    • 제10권5호
    • /
    • pp.98-106
    • /
    • 2002
  • The airflow characteristics of an air-conditioning duct with multiple diffusers were investigated through one-dimensional analysis, CFD simulation and experimental measurement. One-dimensional program based on Bernoulli's equation and minor loss equations was developed in order to evaluate the air distribution rate at each diffuser. In CFD simulation, three-dimensional flow characteristics inside air-conditioning duct were computed for incompressible viscous flow, adopting the RNG k-$\xi$turbulence model. Also, in an effort to equalize the discharge flow rate at each outlet, the optimization procedure has been performed to obtain the optimum diffuser area. In this process, square of difference between maximum discharge rate and minimum discharge rate is used as an object function. Diffuser area and discharge velocity are established as constraints. After optimization process, determined design variables are applied again in CFD simulation and experiment to validate the optimized result by one-dimensional program. Comparison with the experimental data of airflow rate distribution showed that the developed program seems to be acceptable and can be useful design tool for an automotive air-conditioning duct in an initial design stage.

ADCP를 활용한 제주 강정천의 평균유속 분포 추정 (A Study on the Mean Flow Velocity Distribution of Jeju Gangjung-Stream using ADCP)

  • 양세창;김용석;양성기;강명수;강보성
    • 한국환경과학회지
    • /
    • 제26권9호
    • /
    • pp.999-1011
    • /
    • 2017
  • In this study, the Chiu-2D velocity-flow rate distribution based on theoretical background of the entropy probability method was applied to actual ADCP measurement data of Gangjung Stream in Jeju from July 2011 to June 2015 to predict the parameter that take part in velocity distribution of the stream. In addition, surface velocity measured by SIV (Surface Image Velocimeter) was applied to the predicted parameter to calculate discharge. Calculated discharge was compared with observed discharge of ADCP observed during the same time to analyze propriety and applicability of depth of water velocity average conversion factor. To check applicability of the predicted stream parameter, surface velocity and discharge were calculated using SIV and compared with velocity and flow based on ADCP. Discharge calculated by applying velocity factor of SIV to the Chiu-2D velocity-flow rate distribution and discharge based on depth of water velocity average conversion factor of 0.85 were $0.7171m^3/sec$ and $0.5758m^3/sec$, respectively. Their error rates compared to average ADCP discharge of $0.6664m^3/sec$ were respectively 7.63% and 13.64%. Discharge based on the Chiu-2D velocity-flow distribution showed lower error rate compared to discharge based on depth of water velocity average conversion factor of 0.85.

에어컨 실외기 토출그릴 형상 최적화 (A Study on the Optimization of Discharge Grille of Outdoor Unit of Air Conditioner)

  • 최석호;오세기;김현종;진근호;오시영;김병순
    • 설비공학논문집
    • /
    • 제23권11호
    • /
    • pp.726-732
    • /
    • 2011
  • The aerodynamic and aeroacoustic performance of discharge grille of outdoor unit of air-conditioner was investigated in this study. Discharge grille is one of outdoor unit's important parts to affect the flow rate and Overall Sound Pressure Level(OSPL). New type of discharge grille was suggested based on the results of numerical simulation. To simulate the flow pattern near the propeller fan, commercial flow solver FLUENT was used. Sliding mesh method was used for rotating propeller fan and initial condition for unsteady model was calculated by Multiple Reference Frame(MRF) method. To minimize the interaction noise between fan blade wake and discharge grille, new discharge grille has radial rib which is aligned with trailing edge of fan blade. And inclined radial rib was adopted for reducing flow rate drop in discharge grille. The optimization of inclined angle of radial grille was performed experimentally.