Particle removal characteristics of high-velocity electrostatic mist eliminator (정전 고속 미스트 엘리미네이터의 포집 효율 특성)

  • Kim, Jin-seon;Kim, Hak-Joon;Han, Bangwoo;Woo, Chang Gyu;Kim, Yong-Jin;Lee, Sangrin;Moon, Sangchul
    • Particle and aerosol research
    • /
    • v.14 no.4
    • /
    • pp.121-133
    • /
    • 2018
  • In this study, we developed a flat-plate type wet electrostatic precipitator that generates stable corona discharge compared to wire type discharge electrode. In order to compare the particle removal efficiency according to the shape of the discharge electrode such as the variation of the horizontal and vertical distance between spiked edges, and the variation of the height of discharge pin support were tested. As a result, when the horizontal distance between spiked edges was increased up to 36 mm, the vertical distance between spiked edges was increased up to 54 mm, and the height of the discharge pin support was increased up to 76 mm, the removal efficiency of PM10 was maintained at approximate 60.0%. Furthermore, the removal efficiency of particles over $5{\mu}m$ was about 80% or more. When the flow rate was 4 m/s, the gap between collection plates was 60 mm, and -14 kV was applied to the discharge electrode. The particle removal efficiency of the flat-plate type electrostatic precipitator was maintained when the horizontal and vertical distance between spiked edges, and the height of the discharge pin support was below a certain level. Those variables may be the important design factors for the shape of the discharge electrode. Therefore, when designing the electrostatic precipitator with multiple channels, the horizontal and vertical distance between spiked edges, and the height of discharge pin support must be selected in consideration of the weight of the discharge electrode and the processing cost.

The Characteristics of a Superposed Discharge Type Ozonizer with Variation of Mesh in Internal Electrode (내부전극 조밀도 변화에 따른 중첩방전형 오존발생기의 특성)

  • Song, Hyun-Jig
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.19 no.5
    • /
    • pp.87-93
    • /
    • 2005
  • In order to develope high concentration$\cdot$yield ozonizer, superposed discharge type ozonizer using overlap of silent discharge and internal electrode of mesh type has been designed and manufactured. It consists of three electrodes(central electrode, internal electrode and external electrode) and double gaps(gap between central electrode and internal electrode, gap between internal electrode and external electrode). Therefore, ozone is generated by overlapping silent discharges generated between the gaps respectively for which the AC high voltages applied to the internal electrode and the external electrode has a $180{[^\circ]}$ phase difference and for which the central electrode is a ground Ozone generation characteristics proportional to mesh of internal electrode by increasing of discharge electrode and controlling of discharge power density. As a result, the in maximum ozone concentration, generation, and yield can be obtained 17,720[ppm], 5.4[g/h], and 205[g/kwh] respectively.

Effect of auxiliary electrode on the discharge characteristics in AC PDP with long sustain-gap

  • Park, Sang-Dae;Lee, Seung-Hun;Shin, Nam-Hoon;Lee, Kyo-Sung;Park, Sung-Yun;Kim, Sang-Ho;Shin, Bhum-Jae;Choi, Kyung-Cheol
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2004.08a
    • /
    • pp.109-112
    • /
    • 2004
  • The effect of auxiliary electrode on the discharge characteristics in AC PDP with long sustain-gap was investigated. The auxiliary electrode was placed between scan and common electrode. When the pulse was applied to the auxiliary electrode during sustain period, the luminance of Ne + 13%Xe gas-mixture discharge increased and the discharge current decreased. The auxiliary pulse plays a role of improving electron excitation efficiency. When the auxiliary pulse was applied during address period, the address discharge time lag of Ne + 13%Xe gas-mixture could be reduced remarkably.

  • PDF

Study on Improving the luminous Efficiency of AC PDPs using the Dual Mode Discharge Electrode Structure Having Short-Gap and Long-Gap Discharge (Short-gap과 Long-gap의 이중 방전 전극 구조를 갖는 AC형 플라즈마 표시기의 효율 향상에 대한 연구)

  • 신범재;김태준;이주광;황기웅
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.52 no.11
    • /
    • pp.529-535
    • /
    • 2003
  • In this paper, we presents the characteristics of the new electrode structure in an AC Plasma Display Panel(PDP) that can generate dual mode discharges with a combination of short-gap and long-gap discharges. The experiment results show that the discharge voltage of the new electrode structure is mainly determined by short-gap discharge and the luminous efficiency is improved by 20% compared with the conventional electrode structure. The improvement of luminous efficiency is mainly caused by higher VUV generation and broader distribution from Ole ICCD camera measurements.

INVESTIGATION OF "STEPPED" DISCHARGE CURVES IN SINTERED TYPE NICKEL-CADMIUM CELL

  • SASAKI, Y.;YAMASHITA, T.
    • Journal of the Korean institute of surface engineering
    • /
    • v.32 no.3
    • /
    • pp.360-362
    • /
    • 1999
  • Formation of the nickel-cadmium alloy in the negative electrode of nickel-cadmium cell subjected to continuous charging at elevated temperatures ($40~45^{\circ}C$) is shown to be one of the causes of the 'stepped' discharge curves. The alloy has been characterized by electrode potential measurement and X-ray diffraction method. The potential lowering during discharge is related to discharge of the alloy. X -ray diffraction suggests that the nickel-cadmium alloy can be formed during charge in negative electrode by interaction of the two metals. Addition of Ni $(OH)_2$ into $Cd{\;}(OH)_2$ active material is found to form the alloy more readily than sintered negative electrode alone.ode alone.

  • PDF

Effect of a Cylindrical Third Electrode of a Point-Plate Type Plasma Reactor on Corona Discharge and Ozone Generation Characteristics (침대 평판형 플라즈마장치의 코로나 방전 및 오존발생 특성에 미치는 원통형 3전극의 영향)

  • Moon, Jae-Duk;Jung, Ho-Jun;Jung, Jae-Seung
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.56 no.5
    • /
    • pp.933-937
    • /
    • 2007
  • A point plate type nonthermal plasma reactor, with a grounded cylindrical third electrode which closely- encompasses the needle point, have been investigated with an emphasis on the role of the third electrode. It was found that the point plate airgap, with the grounded third electrode, had a switching characteristic on its I V characteristics for negative and positive discharges, which is very different from that of a conventional point plate airgap without a third electrode. The corona discharge and ozone generation characteristics of the plasma reactor with the grounded cylindrical third electrode, such as the corona onset voltage. the breakdown voltage. the corona current. and the amount of output ozone, were influenced significantly by the height of the third electrode. and these characteristics can be controlled by adjusting the height of the third electrode.

Discharge Area Characteristics of Ozonizer with $Al_2O_3$ Dielectric ($Al_2O_3$ 세라믹 유전체 오존발생기의 방전면적 특성)

  • Park, Hyun-Mi;Song, Hyun-Jig;Lee, Sang-Gun;Lim, Chang-Ho;Yoon, Bung-Han;Kim, Jong-Hyun;Lee, Kwang-Sik
    • Proceedings of the KIEE Conference
    • /
    • 2005.07c
    • /
    • pp.2214-2216
    • /
    • 2005
  • This paper is researched discharge and ozone generation characteristics of ozonizer using $Al_2O_3$ Ceramic dielectric. The discharge characteristics with variation of the discharge electrode area is studied. The characteristics of ozone concentration. ozone generation and ozone yield were measured to discharge power, discharge electrode area and supplied gas flux for oxygen and air. The solubility of ozone for water concentrations and ozone generations proportional to discharge power and discharge electrode area. Ozone yield has slowly increase with Increasing discharge power at high flow-rate. As the result, the maximum values of ozone characteristics ozone generation and ozone yield, can be obtained 5817[ppm] and 36[g/kWh]. We make enough the ozone concentration as the air in the home. An electric discharge electrode area is apt to shrink gradually into a miniaturization trend of the ozonizer but the enlargement of the occurrence flight of the electric discharge area gives the characteristic enhance the aid in the identity condition through the structure improvement.

  • PDF

Multi-hole RF CCP 방전에서 방전 주파수가 미치는 영향

  • Lee, Heon-Su;Lee, Yun-Seong;Seo, Sang-Hun;Jang, Hong-Yeong
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2011.08a
    • /
    • pp.145-145
    • /
    • 2011
  • Recently, multi-hole electrode RF capacitively coupled plasma discharge is being used in the deposition of microcrystalline silicon for thin film solar cell to increase the speed of deposition. To make efficient multi-hole electrode RF capacitively coupled plasma discharge, the hole diameter is to be designed concerning the plasma parameters. In past studies, the relationship between plasma parameters such as pressures and gas species, and hole diameter for efficient plasma density enhancement is experimentally shown. In the presentation, the relationship between plasma deriving frequency and hole diameter for efficient multi-hole electrode RF capacitively coupled plasma discharge is shown. In usual capacitively coupled plasma discharge, plasma parameter, such as plasma density, plasma impedence and plasma temperature, change as frequency increases. Because of the change, the optimum hole diameter of the multi-hole electrode RF capacitively coupled plasma for high density plasma is thought to be modified when the plasma deriving frequency changes. To see the frequency effect on the multi-hole RF capacitively coupled plasma is discharged and one of its electrode is changed from a plane electrode to a variety of multi-hole electrodes with different hole diameters. The discharge is derived by RF power source with various frequency and the plasma parameter is measured with RF compensated single Langmuir probe. The shrinkage of the hole diameter for efficient discharge is observed as the plasma deriving frequency increases.

  • PDF

A Study on Diagnosis of Partial Discharge Type Using Wavelet Transform-Neural Network (웨이블렛-신경망을 이용한 부분방전 종류와 진단에 관한연구)

  • Park, Jae-Jun;Jeon, Hyun-Gu;Jeon, Byung-Hoon;Kim, Sung-Hong;Kwon, Dong-Jin
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.07b
    • /
    • pp.894-899
    • /
    • 2002
  • In this papers, we proposed the new method in order to diagnosis partial discharge type of transformers. For wavelet transform, Daubechies filter is used, we can obtain wavelet coefficients which is used to extract feature of statistical parameters (maximum value, average value, dispersion, skewness, kurtosis) about high frequency current signal per 3-electrode type (needle-plane electrode, IEC electrode and Void electrode.). Also. these coefficients are used to identify Signal of internal partial discharge in transformer. As a result. from compare of high frequency current signal amplitude and average value. we are obtained results of IEC electrode> Void electrode> Needle-Plane electrode. otherwise. In case of skewness and kurtosis, we are obtained results of Void electrode> IEC electrode > Needle-Plane electrode. As Improved method in order to diagnosis partial discharge type of transformers, we use neural network.

  • PDF

A Study on Iron Electrode of Ni/Fe Battery(II) (니켈/철 축전지의 철전극에 관한 연구(II))

  • 김운석;박성용;조원일;조병원;윤경석
    • Journal of Energy Engineering
    • /
    • v.2 no.3
    • /
    • pp.300-307
    • /
    • 1993
  • To develop high performance nickel-iron secondary battery, the characteristics of charge-discharge reaction of iron electrode were examined by cyclic voltammetry technique, SEM and XRD analysis. The capacity of the test electrodes was determined by the constant current charge-discharge method. It was found that the temperature and concentration of electrolyte were the major determinant factors of electrode capacity, and especially the 1st discharge capacity was increased with the increase of temperature. The effect of fore forming agent on the electrode capacity was negligible. The electrode capacity was above 350 ㎃h/g(36% utility) at 0.25C discharge rate. The stability of electrode was very good, but the activation occurred slowly.