• Title/Summary/Keyword: Discharge Distributions

Search Result 157, Processing Time 0.025 seconds

Study on the Temporal and Spatial Variations of Salinity by Freshwater Discharge in Gyeonggi Bay (경기만내 담수 유입으로 인한 시·공간적인 염분변화에 대한 연구)

  • Jeong, Jeong Ho;Kim, Kuk Jin;Yang, Keun Ho;Chang, Yoon Young;Park, Sun Hwan;Kim, Young Taeg
    • Journal of Environmental Impact Assessment
    • /
    • v.16 no.6
    • /
    • pp.421-432
    • /
    • 2007
  • To investigate temporal and spatial variations of hydrodynamics and environmental conditions in Gyeonggi Bay, including Han River estuary, numerical experiments were performed using 3-dimensional fine grid numerical ocean model. The model successfully reproduced the physical phenomena already known in Gyeonggi Bay where tide and fresh water discharge are dominant forcings. The calculated harmonic constants of tide and tidal current agreed well with those of observations at nine tide stations and two tidal current stations. Tidal asymmetries along the Yeomha Waterway, mainly caused by non-linear effect, were well reproduced and agreed well with observations. Time series of salinity at four stations(A, B, C and D) and horizontal distributions of monthly averaged salinity show that Gyodong and Seokmo Waterways play an important role in fresh water discharge into the Gyeonggi Bay rather than Yeomha Waterway.

Effects of Size and Shape of Drain on Horizontal Vacuum Drain (배수재의 직경과 형상변화가 수평진공배수에 미치는 영향)

  • Yoo, Nam-Jae;Park, Byung-Soo;Jeong, Gil-Soo;Lee, Byung-Kon
    • Journal of Industrial Technology
    • /
    • v.21 no.A
    • /
    • pp.293-301
    • /
    • 2001
  • This paper is experimental results of investigating the efficiency of horizontal vacuum drainage system. Effects of size and shape of drain on horizontal vacuum drainage were studied. Model tests in the laboratory with soft marine clay were carried out with drain pipe of having three different diameters and PBD (Plastic Board Drain) of strip shape so that consolidation settlement of soft clay due to applied vacuum pressure, amount of discharge, ground settlement and distributions of pore pressure and undrained shear strength were measured during testing. From results of model test, amount of discharge due to vacuum pressure was increased with the diameter of pipe drain whereas the drain efficiency of pipe in per unit area of drain surface was decreased with diameter of pipe. The rate of discharge per unit time was reduced very fast with diameter of pipe. Settlement of ground surface with time was increased with diameter of pipe as a result of increase of discharge to drain pipe.

  • PDF

Numerical Simulation of Nitrogen Discharge at Medium Pressure between Point-Plane Electrodes (침-평판 전극 사이에서 중간 압력 질소 방전의 시뮬레이션)

  • Koh, Wook-Hee;Park, In-Ho
    • Journal of the Korean Vacuum Society
    • /
    • v.17 no.6
    • /
    • pp.487-494
    • /
    • 2008
  • The numerical simulation of point-to-plane discharge of nitrogen at medium pressure has been achieved by a quasi-2d numerical model. In the model, we calculate the distributions of electric charges which are varying as temporal and space and determine the electric field depending on space charge distribution by solving Poisson's equation. The continuity equations are treated numerically by using FCT (Flux-Corrected Transport) Algorithm and FEM (Finite Element Method). The numerical simulation results make us to understand the physical characteristics of nitrogen discharge at 50 torr. The comparison with experimental results[1] shows a good qualitative agreement.

A Study on Degradation Pattern of GIS Using Clustering Methode (군집화 기법을 이용한 GIS 열화 패턴 연구)

  • Lee, Deok Jin
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.31 no.4
    • /
    • pp.255-260
    • /
    • 2018
  • In recent years, increasing electricity use has led to considerable interest in green energy. In order to effectively supply, cut off, and operate an electric power system, many electric power facilities such as gas insulation switch (GIS), cable, and large substation facilities with higher densities are being developed to meet demand. However, because of the increased use of aging electric power facilities, safety problems are emerging. Electromagnetic wave and leakage current detection are mainly used as sensing methods to detect live-line partial discharges. Although electromagnetic sensors are excellent at providing an initial diagnosis and very reliable, it is difficult to precisely determine the fault point, while leakage current sensors require a connection to the ground line and are very vulnerable to line noise. The partial discharge characteristic in particular is accompanied by statistical irregularity, and it has been reported that proper statistical processing of data is very important. Therefore, in this paper, we present the results of analyzing ${\Phi}-q-n$ cluster distributions of partial discharge characteristics by using K-means clustering to develop an expert partial discharge diagnosis system generated in a GIS facility.

Evaluation of Indoor Thermal Comfort for Ceiling Type System Air-Conditioner with Various Discharge Angles (천장형 시스템 에어컨의 토출방향 변화에 따른 실내 열쾌적성 평가)

  • Lee, Jin-Hyung;Kim, You-Jae;Choi, Weon-Seok;Park, Sung-Kwan;Youn, Baek;Kim, Youn-Jea
    • Proceedings of the SAREK Conference
    • /
    • 2006.06a
    • /
    • pp.1180-1185
    • /
    • 2006
  • Modern people spend most of time at indoor space, such as office or classroom. Especially, occupants are exposed to the airtight indoor air quality (IAQ) for a long time, At present, many studies on the air-conditioning systems are more focused on the individual thermal comfort than the thermal efficiency due to increase of the concern of health. There are several factors which are influenced thermal comfort, such as temperature, humidity, convection and air movement, etc. Also, the individual factor, such as age, gender, Physical constitution and habit, should be considered. The 4-way cassette type air conditioner is known to bring out better performance about thermal comfort than the traditional one. This study is performed on the higher ceiling environment than the common buildings or classrooms. Also, this study analyzed on the Indoor thermal comfort by diffusing direction of 4-way cassette air conditioner with various discharge angles, $45^{\circ},\;50^{\circ},\;55^{\circ}$ and $60^{\circ}$. Using a commercial code, FLUENT, three-dimensional transient air thermal flow fields are calculated with appropriate wall boundary conditions and standard $k-{\epsilon}$ turbulence model. Results of velocity and temperature distributions are graphically depicted with various discharge angles.

  • PDF

The Influence of the Surrounding Groundwater by Groundwater Discharge from the Subway Tunnel at Suyeong District, Busan City (부산 수영구 지하철 터널에서의 지하수 유출이 주변 지하수에 미치는 영향)

  • Chung, Sang-Yong;Kim, Tae-Hyung;Park, Nam-Sik
    • Journal of Soil and Groundwater Environment
    • /
    • v.17 no.2
    • /
    • pp.28-36
    • /
    • 2012
  • This study carried out several kinds of investigations such as geology, hydrogeology, groundwater level and quality, surface-water quality, and the quantity and quality of groundwater discharge from the subway to identify the causes of groundwater contamination around the subway tunnel at Suyeong District in Busan City. Geostatistical analyses were also conducted to understand the characteristics of groundwater level and quality distributions. There are Kwanganri Beach and Suyeong River in the study area, which are basically influenced by seawater. The total quantities of groundwater utilization and groundwater discharge from the subway tunnel in Suyeong District are 2,282,000 $m^3$/year, which is 2.4 times larger than the sustainable development yield of groundwater. The lowest groundwater level around the subway tunnel is about 32 m below the mean sea-level. The large drawdown of groundwater led to the inflow of seawater and salinized river water toward the subway tunnel, and therefore the quality of groundwater didn't satisfy the criteria of potable, domestic, agricultural and industrial uses. Distribution maps of groundwater level and qualities produced by kriging were very useful for determining the causes of groundwater contamination in the study area. The distribution maps of electrical conductivity, chloride and sulfate showed the extent of seawater intrusion and the forceful infiltration of the salinized Suyeong River. This study revealed that seawater and salinized river water infiltrated into the inland groundwater and contaminated the groundwater around the subway tunnel, because the groundwater level was seriously drawdowned by groundwater discharge from the subway tunnel. The countermeasure for the minimization of groundwater discharge from the subway tunnel is necessary to prevent the groundwater obstacles such as groundwater depletion, groundwater-quality deterioration, and land subsidence.

A Study on the Influence of the Saemangeum Sluice-Gates Effluent Discharge using the Particle Tracking Model (입자추적 실험을 이용한 새만금 배수갑문 유출수의 영향 범위 연구)

  • Cho, Chang Woo;Song, Yong Sik;Bang, Ki Young
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.32 no.4
    • /
    • pp.211-222
    • /
    • 2020
  • This study suggested a method calculating the influence of effluent discharge from Saemangeum sluice-gates using the particle tracking model. For 2017, we presented the seasonal effects of effluent discharge as probability spatial distributions and compared with the results of the water age, one of the indicators of transport time scale. The influence of sluice-gates effluent discharge increases radially around Sinshi or Gaseok gates, which are expected to be biased toward the south in winter and north in summer due to the effect of seasonal winds. Although the results of the prediction are limited to the 2017 situation, the method of calculating the influence of sluice-gates effluent discharge using the Lagrangian particle tracking model can be used to predict the future of the around Saemangeum.

Radial Density Distributions in the Positive Column of a Strongly Modulated Mercury-rare gas AC Discharge (변조된 수은-희유기체 교류방전의 양광주 내의 반경방향 입자분포)

  • 이진우;여인선
    • The Proceedings of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.7 no.2
    • /
    • pp.31-35
    • /
    • 1993
  • The radial density distributions of the positive column of strongly modulated low -pressure gas discharges in mercury - rare gas mixtures at 10 tom pressure have been studied theoretically. The current was modulated inusoidally with a modulation depth of 50%. Calculations have shown that the radial profile of the excited atoms is ditferent form 0th Bessel function $J_0$(2.4r/R) and the invertion of the radial distribution of the excited atom can occur at some frequency. The hybrid method of FDM and 2nd order Runge-Kutta meth od is used for solving differenzial equations.

  • PDF

Magnetic Flux Density Distributions and Discharge Characteristics of a Newly Designed Magnetized Inductively Coupled Plasma

  • Cheong, Hee-Woon
    • Journal of Magnetics
    • /
    • v.20 no.4
    • /
    • pp.360-365
    • /
    • 2015
  • Spatial distributions of magnetic flux density in a newly designed magnetized inductively coupled plasma (M-ICP) etcher were investigated. Radial and axial magnetic flux densities as well as the magnetic flux density on the center of the substrate holder were controllable by placing multiple circular coils around the etcher properly. The plasma density non-uniformity in M-ICP (25 Gauss) can be reduced (1.4%) compared to that in ICP (16.7%) when the neutral gas pressure was 0.67 Pa and a right-hand circularly polarized wave (R-wave) can be propagated in to the etcher by making magnetic flux density increases both radially and axially from the center of the substrate holder.

Neutral Beam Evolution in the KSTAR NBI Test Stand

  • In, S.R.;Shim, H.J.
    • Journal of Korean Vacuum Science & Technology
    • /
    • v.7 no.1
    • /
    • pp.1-7
    • /
    • 2003
  • The pressure distributions in the test stand built for developing KSTAR NBI ion sources were obtained using a network system composed of conductance elements modeling the ion source, the neutralizer, and other beam line components. The allowable regime was defined on the coordinates of the gas supply rate to the ion source and the neutralizer, considering the proper conditions of the three critical parameters, the ion source pressure for good arc discharge, the pressure integral in the neutralizer for sufficient neutralization, and the chamber pressure for minimum neutral beam loss. The neutral beam evolution along the path from the ion source extraction grid to the calorimeter through the neutralizer, the bending magnet and the vacuum chamber was estimated for typical pressure distributions.

  • PDF