• Title/Summary/Keyword: Disaster Area

Search Result 1,514, Processing Time 0.024 seconds

Analysis of PM2.5 Impact and Human Exposure from Worst-Case of Mt. Baekdu Volcanic Eruption (백두산 분화 Worst-case로 인한 우리나라 초미세먼지(PM2.5) 영향분석 및 노출평가)

  • Park, Jae Eun;Kim, Hyerim;Sunwoo, Young
    • Korean Journal of Remote Sensing
    • /
    • v.36 no.5_4
    • /
    • pp.1267-1276
    • /
    • 2020
  • To quantitatively predict the impacts of large-scale volcanic eruptions of Mt. Baekdu on air quality and damage around the Korean Peninsula, a three-dimensional chemistry-transport modeling system (Weather Research & Forecasting - Sparse Matrix Operation Kernel Emission - Comunity Multi-scale Air Quality) was adopted. A worst-case meteorology scenario was selected to estimate the direct impact on Korea. This study applied the typical worst-case scenarios that are likely to cause significant damage to Korea among worst-case volcanic eruptions of Mt. Baekdu in the past decade (2005~2014) and assumed a massive VEI 4 volcanic eruption on May 16, 2012, to analyze the concentration of PM2.5 caused by the volcanic eruption. The effects of air quality in each region-cities, counties, boroughs-were estimated, and vulnerable areas were derived by conducting an exposure assessment reflecting vulnerable groups. Moreover, the effects of cities, counties, and boroughs were analyzed with a high-resolution scale (9 km × 9 km) to derive vulnerable areas within the regions. As a result of analyzing the typical worst-case volcanic eruptions of Mt. Baekdu, a discrepancy was shown in areas between high PM2.5 concentration, high population density, and where vulnerable groups are concentrated. From the result, PM2.5 peak concentration was about 24,547 ㎍/㎥, which is estimated to be a more serious situation than the eruption of Mt. St. Helensin 1980, which is known for 540 million tons of volcanic ash. Paju, Gimpo, Goyang, Ganghwa, Sancheong, Hadong showed to have a high PM2.5 concentration. Paju appeared to be the most vulnerable area from the exposure assessment. While areas estimated with a high concentration of air pollutants are important, it is also necessary to develop plans and measures considering densely populated areas or areas with high concentrations of susceptible population or vulnerable groups. Also, establishing measures for each vulnerable area by selecting high concentration areas within cities, counties, and boroughs rather than establishing uniform measures for all regions is needed. This study will provide the foundation for developing the standards for disaster declaration and preemptive response systems for volcanic eruptions.

GIS Spatial Analysis of Vulnerability of Protected Cultivation Area to Meteorological Disaster : A Case Study of Jeollanambuk Province, South Korea (GIS를 이용한 시설재배의 기상재해 취약지역 해석 - 전라남북도의 사례를 중심으로 -)

  • Kim, Dong Hyeon;Kang, Dong Hyeon;Lee, Si Young;Son, Jin Kwan;Park, Min Jung;Yoon, Yong-Cheol;Yun, Sung-Wook
    • Journal of Bio-Environment Control
    • /
    • v.26 no.2
    • /
    • pp.87-99
    • /
    • 2017
  • Recently the increase in an abnormal climate events and meteorological disasters which causes a great damage to greenhouse facilities. To minimize and evaluate the expected damages it is necessary to prepare countermeasures and a management system in advance. For this purpose, a quantitative analysis of weather and abnormal climate are needed to investigate protected cultivation areas which are vulnerable to natural disasters. This study focused on protected cultivation areas in Jeolla province, South Korea. Surrogate variables were calculated to analyze the vulnerable areas to meteorological disasters, and spatial distribution analysis was also performed by using GIS to present vulnerable areas on map. The map thus created and was compared with actual data of damages by meteorological disasters which occurred in target areas. The result of the comparison is as follows: About 50% of the target areas showed an agreement between the map created in this study and the actual data, these areas includes Gwangju metropolitan city, Naju city, Yeongam County, Jangseong County, Hampyeong County, and Haenam County. On the other hand, other areas, including Gunsan city, Mokpo city, and Muan County, suffered low damage in spite of high levels of vulnerability to meteorological disasters. This result was considered to be affected by such variables as different structural designs and management systems of greenhouses by region. This study carried out an analysis of meteorological data to find out more detailed vulnerability to protected cultivation area and to create a map of vulnerable protected cultivation areas. In addition, the map was compared with the record of natural disasters to identify actual vulnerable areas. In conclusion, this study can be utilized as basic data for preventing and reducing damages by meteorological disasters in terms of design and management of greenhouses.

Wildfire Severity Mapping Using Sentinel Satellite Data Based on Machine Learning Approaches (Sentinel 위성영상과 기계학습을 이용한 국내산불 피해강도 탐지)

  • Sim, Seongmun;Kim, Woohyeok;Lee, Jaese;Kang, Yoojin;Im, Jungho;Kwon, Chunguen;Kim, Sungyong
    • Korean Journal of Remote Sensing
    • /
    • v.36 no.5_3
    • /
    • pp.1109-1123
    • /
    • 2020
  • In South Korea with forest as a major land cover class (over 60% of the country), many wildfires occur every year. Wildfires weaken the shear strength of the soil, forming a layer of soil that is vulnerable to landslides. It is important to identify the severity of a wildfire as well as the burned area to sustainably manage the forest. Although satellite remote sensing has been widely used to map wildfire severity, it is often difficult to determine the severity using only the temporal change of satellite-derived indices such as Normalized Difference Vegetation Index (NDVI) and Normalized Burn Ratio (NBR). In this study, we proposed an approach for determining wildfire severity based on machine learning through the synergistic use of Sentinel-1A Synthetic Aperture Radar-C data and Sentinel-2A Multi Spectral Instrument data. Three wildfire cases-Samcheok in May 2017, Gangreung·Donghae in April 2019, and Gosung·Sokcho in April 2019-were used for developing wildfire severity mapping models with three machine learning algorithms (i.e., Random Forest, Logistic Regression, and Support Vector Machine). The results showed that the random forest model yielded the best performance, resulting in an overall accuracy of 82.3%. The cross-site validation to examine the spatiotemporal transferability of the machine learning models showed that the models were highly sensitive to temporal differences between the training and validation sites, especially in the early growing season. This implies that a more robust model with high spatiotemporal transferability can be developed when more wildfire cases with different seasons and areas are added in the future.

A Model Experiment Study to Secure the Straight Line Distance between the Air Inlet and Exhaust Section of the Living Room (거실제연설비중 공기유입구와 배출구간 직선거리 확보를 위한 모형실험연구)

  • Saeng-Gon Lee;Se-Hong Min
    • Journal of the Society of Disaster Information
    • /
    • v.19 no.2
    • /
    • pp.439-450
    • /
    • 2023
  • Purpose: When conducting fire inspections in Korea, there are objects that violate the fire protection regulations that require a straight line distance of more than 5m between the air inlet and the discharge section if the floor area is less than 400m2, and this paper analyzes the reasons and conducts a model experimental study to support the need for related fire protection regulations. Method: Domestic firefighting objects were investigated and confirmed, domestic and foreign papers, policies, and laws and regulations were examined, and spaces with a straight line distance of less than 5m and more than 5m between the air inlet and discharge section were selected and analyzed through model experiments in a living room of less than 400m2 . Result: When examining the domestic fire protection regulations (NFPCNational Fire Perpormance Code), the separation distance between the air inlet and the outlet is more than 5m when the floor area is less than 400m2 , but as a result of the actual investigation, it was confirmed that there are firefighting objects that cannot keep the separation distance. In addition, when a paper review of overseas fire protection regulations for a straight line distance of more than 5m showed that there was no regulation on the straight line distance between the air inlet and the discharge section, the model experiment showed that the discharge speed was better when the straight line distance between the air inlet and the discharge section was more than 5m than when it was less than 5m. Conclusions: In this study, when examining overseas fire laws and regulations by comparing the performance of the fire protection ratio for the straight line distance between the air inlet and the exhaust section, there is no mandatory regulation for the straight line distance, but the domestic fire protection regulations (NFPCNational Fire Perpormance Code) require more than 5m. It is hoped that this will be reflected in the design stage in the future, and a foundation will be laid to reduce the responsibility and burden of fire superintendents.

Orhtophoto Accuracy Assessment of Ultra-light Fixed Wing UAV Photogrammetry Techniques (초경량 고정익무인항공기 사진측량기법의 정사영상 정확도 평가)

  • Lee, In Su;Lee, Jae One;Kim, Su Jeong;Hong, Soon Heon
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.33 no.6
    • /
    • pp.2593-2600
    • /
    • 2013
  • The main purpose of this study is to carry out the performance evaluation of Ultra-light Fixed Wing UAV(Unmanned Aerial Vehicle) photogrammetry which is being, currently, applied for various fields such as cultural assets, accident survey, military reconnaissance work, and disaster management at home and abroad. Firstly, RMSE estimation of Aerial Triangulation (AT) are within approximately 0.10 cm in position (X, Y). And through the comparison of parcel's boundary points coordinates by terrestrial surveying and by UAV photogrammetry, the analysis shows that RMSE are shifted approximately 0.174~0.205 m in X-direction, 0.294~0.298 m in Y-direction respectively. Lastly, parcel's area by orthophoto of UAV photogrammetry and by that of cadastre register has been shown the difference by 0.118 m2. The results presented in this study is just one case study of orthophoto accuracy assessment of Ultra-light fixed wing UAV photogrammetry, hereafter various researches such as AT, direct-georeferencing, flight planning, practical applications, etc. should be necessary continuously.

Resilience of Cultural Heritage by Integrating Historic Maps and Geospatial Information (고지도와 시계열 공간정보를 활용한 문화재 리질리언스에 대한 연구)

  • Bae, Junsu;Yang, Yunjung;Choi, Yoonjo;Kim, Sangkyun
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.39 no.6
    • /
    • pp.945-954
    • /
    • 2019
  • Cultural property is a valuable asset that connects the past with the present, and cultural heritage is now included in the international agenda of disaster risk reduction. Accordingly, the importance of building resilience of cultural assets has been on the rise, and the necessity of spatial information has been emphasized in building resilience. Therefore, in this study, A methodology for studying the resilience contained in cultural assets through linkage with historical map and time series spatial information is proposed and the proposed methodology was applied to cultural assets located in Gongju area. Georeferencing was performed on time-series images of aerial images and topographical map, and the changes in cultural assets and surrounding areas were found. The width of the river has changed due to the installation of the Keum River Estuary Dam and the dammed pool for irrigation. Nevertheless, the main cultural assets and monuments are located in the high-altitude area and thus have been well preserved. In this study, cultural property resilience was extracted using only map data and in future, it is necessary to conduct research to extract cultural property resilience through analysis of historical records such as geography.

Analysis on the Area by Forest Function and the Reflection of Ecosystem Service Concepts in Korea's National Forest Management Plans (최근 국유림경영계획에서 산림기능별 면적구분과 생태계서비스 개념의 반영에 관한 분석)

  • Ko, Kiyeon;Choi, Jaeyong
    • Journal of Korean Society of Forest Science
    • /
    • v.109 no.2
    • /
    • pp.211-222
    • /
    • 2020
  • This study tried to find out whether there is a change over time in the functional classification of forests in relation to human demand for forests. The level in which the concept of ecosystem services has been considered in national forest management plans was also examined. A total of 98 current and previous national forest management plans were available for this study. The composition ratios of the six functions of forests in both the current and previous national forest management plans were surveyed. We used a parametric t-test when the mean values of two (current and previous) groups were normally distributed and used nonparametric Wilcoxon code rank test when the assumption of normality was not met. Timber production forests were shown to follow a normal distribution, while five others, including water regeneration forests, disaster prevention forests, natural environment conservation forests, recreation forests, and living environment conservation forests were not shown to follow a normal distribution. Timber production forests and natural environment forests showed significant changes in the proportion of forest area between previous and current forest management plans. The concept of 'ecosystem services' began to actively appear in the 6th Basic Forest Plan, which started in 2018. However, the level of frequency of the ecosystem services mentioned varied by Regional Forest Services.

Ground Subsidence Caused by the Development of Underground Karstic Networks in Limestone Terrain, Taebag City Korea (석회암 분포지에서 터널시공에 따른 지표침하 원인 분석)

  • Lee, Byung-Joo;Park, SungWook;Kim, Dea-Hong;Song, Young-Karb
    • The Journal of Engineering Geology
    • /
    • v.26 no.1
    • /
    • pp.63-70
    • /
    • 2016
  • The aim of this study is the safety and an accident prevention in limestone terrain by the underground tunneling. The geology of the study area consists of a Paleozoic sedimentary sequence dominated by limestone, sandstone, shale, and carbonaceous shale. The sequence gently dips to the northeast but the joint contains steep with variable trend. A significant fracture zone is developed in the limestone and shale beds, sub-parallel to bedding, and follows in part the limestone-sandstone contact. Monitoring of groundwater levels in the area shows marked fluctuations in the water table, which repeatedly rose to a level of -4 m before sinking to -15 m. These cycles occurred in mid-May, 2007 and in early and middle June. The data indicate that these fluctuations were unrelated to rainfall that occurred during the study period. We infer that the fluctuations were associated with the development of underground karstic networks along the deep fracture zone, and overlying ground subsidence is likely related to the rapid sinking of groundwater and the associated strong downward suction force.

Combustive Properties of Medium Density Fibreboard (MDF) Specimens Treated with Alkylenediaminoalkyl-Bis-Phosphonic Acid Derivatives (알킬렌디아미노알킬-비스-포스폰산 유도체에 의해 처리된 중밀도섬유판의 연소성)

  • Jin, Eui;Chung, Yeong-Jin
    • Fire Science and Engineering
    • /
    • v.28 no.4
    • /
    • pp.57-63
    • /
    • 2014
  • This study was performed to test the combustive properties of Medium Density Fibreboard (MDF) specimens treated with piperazinomethyl-bis-phosphonic acid (PIPEABP), methylpiperazinomethyl-bis-phosphonic acid (MPIPEABP), and N,N-dimethylethylenediaminomethyl-bis-phosphonic acid (MDEDAP). MDF Plates were painted in three times with 15 wt% solution of the alkylenediaminoalkyl-bis-phosphonic acids at the room temperature, respectively. After drying specimen treated with chemicals, combustive properties were examined by the cone calorimeter (ISO 5660-1). It was indicated that the specimens treated with chemicals showed the later time to peak mass loss rate ($TMLR_{peak}$) = (340475) s than that of virgin plate by reducing the burning rate. In adition, the specimens treated with chemicals showed the higher $CO_{mean}$ production (0.0883~0.0963) kg/kg than that of virgin plate. Especially, the specimens treated with chemicals showed the higher mean smoke extinction area ($SEA_{mean}$) ($5m^2/kg{\sim}21.5m^2/kg$) than that of virgin plate. Thus, It is supposed that the combustion-retardation properties were improved by the partial due to the treated alkylenediaminoalkyl-bis-phosphonic acids in the virgin MDF Plate. However, It gave a negative effect on smoke reduction.

Analysis on Rainwater Harvesting System as a Source of Non-Potable Water for Flood Mitigation in Metro Manila (마닐라의 홍수저감을 위한 잡용수 대체자원으로서의 가정용우수저류시설 분석)

  • Necesito, Imee V.;Felix, Micah Lourdes A.;Kim, Lee-Hyung;Cheong, Tae Sung;Jeong, Sangman
    • Journal of Wetlands Research
    • /
    • v.15 no.2
    • /
    • pp.223-231
    • /
    • 2013
  • Excessive precipitation, drought, heat waves, strong typhoons and rising sea levels are just some of the common indicators of climate change. In the Philippines, excessive precipitation never failed to devastate and drown the streets of Metro Manila, a highly urbanized and flood-prone area; such problems are expected to occur frequently. Moreover, the water supply of Metro Manila is dependent only to Angat Reservoir. Rainwater harvesting can serve as an alternative source of raw water and it can mitigate the effects of flooding. The harvested rainwater can be used for: potable consumption if filtered and disinfected; and non-potable consumptions (e.g., irrigation, flushing toilets, carwash, gardening, etc.) if used untreated. The rainfall data were gathered from all 5 rainfall stations located in Metro Manila namely: Science Garden, Port Area, Polo, Nangka and Napindan rain gauge stations. To be able to determine the potential volume of rainwater harvested and the potentiality of rainwater harvesting system as an alternate source of raw water; in this study, three different climatic conditions were considered, the dry, median and wet rainfall years. The frequent occurrence of cyclonic events in the Philippines brought significant amount of rainwater that causes flooding in the highly urbanized region of Metro Manila. Based from the results of this study, the utilization of rainwater harvesting system can serve as an alternative source of non-potable water for the community; and could also reduce the amount of surface runoff that could result to extreme flooding.