• 제목/요약/키워드: Directional Weight

검색결과 89건 처리시간 0.023초

A Modular Bi-Directional Power Electronic Transformer

  • Gao, Zhigang;Fan, Hui
    • Journal of Power Electronics
    • /
    • 제16권2호
    • /
    • pp.399-413
    • /
    • 2016
  • This paper presents a topology for a modular power electronic transformer (PET) and a control scheme. The proposed PET consists of a cascaded H-Bridge rectifier on the primary side, a high-frequency DC/DC conversion cell in the center, and a cascaded H-Bridge inverter on the secondary side. It is practical to use PETs in power systems to reduce the cost, weight and size. A detailed analysis of the structure is carried out by using equivalent circuit. An algorithm to control the voltages of each capacitor and to maintain the power flow in the PET is established. The merits are analyzed and verified in theory, including the bi-directional power flow, variable voltage/frequency and high power factor on the primary side. The experimental results validated the propose structure and algorithm.

Directional Asymmetry of Gonadal Development in Ayu (Plecoglossus altivelis)

  • Park In-Seok;Zhang Chang Ik;Kim Young Ja;Bang In Chul
    • Fisheries and Aquatic Sciences
    • /
    • 제8권4호
    • /
    • pp.207-212
    • /
    • 2005
  • Directional (sinistral) asymmetry (DA) occurs when the traits of one side of a supposedly bilaterally symmetrical organism differ in a random way from those of the other side. We examined asymmetries in gonadal growth traits within both sexes of hatchery reared ayu, Plecoglossus altivelis. The pattern of the gonadal growth from hatching to 320 days after hatching was a type of DA except for the growth in gonad weight from 140 to 180 days after hatching, although the ovary of the right side tended to exhibit more pronounced DA phenomenon.

안뜰감각 자극운동이 성인여성의 안정성한계, 동적체중이동 및 팔다리 반응시간에 미치는 영향 (Effect of Vestibular Sensory Stimulation Exercise on Limit of Stability, Dynamic Weight Shift, and Upper and Lower Extremities Reaction Time in Adult Women)

  • 김충유;이건철;이연섭
    • 대한통합의학회지
    • /
    • 제10권2호
    • /
    • pp.203-210
    • /
    • 2022
  • Purpose : The purpose of this study was to investigate the effect of vestibular sensory stimulation exercise on the limit of stability, dynamic weight shift, and upper and lower extremities reaction time in adult women. Methods : This study was conducted with 30 female. All subjects were randomly and equally assigned to an experimental group and a control group of 15 each. Subjects assigned to the experimental group received vestibular sensory stimulation training for 6 weeks. For the intervention, vestibular sensory stimulation exercises were conducted by referring to the Hamid exercise method and the Cawthorne-Cooksey exercise method, and the control group did not receive any intervention. All subjects were tested for limit of stability, dynamic weight shift, and upper and lower extremities reaction time before and after the intervention. Results : The results of this study showed significant differences between groups in reaction time, moving velocity, and directional control in the limit of stability test after intervention. In the dynamic weight shift test after intervention, there was a significant difference between the groups in the slow directional control of left and right. And in the upper and lower extremities reaction time test after intervention, both scores and reaction time showed significant differences between groups. Conclusion : As a result, the three vestibular sensory stimulation exercises applied in this study improved the limit of stability, dynamic weight shift, and upper and lower extremities reaction time.

선택적 방향주의를 가지는 수정된 스캔라인 일반화 대칭 변환 (Modified Scan Line Based Generalized Symmetry Transform with Selectively Directional Attention)

  • 김동수;진성일
    • 대한전자공학회논문지SP
    • /
    • 제38권4호
    • /
    • pp.411-421
    • /
    • 2001
  • 일반화 대칭 변환 (generalized symmetry transform, GST)은 주어진 영상에서 사전 분할이 없이 국부성과 반사 대칭성을 결합하여 대칭을 측정하고 관심 영역을 추출한다. GST의 거리 가중치 함수에서 국부적인 대칭성이 반영되며 이 함수의 표준 편차 u에 의해 GST의 수행 범위가 조절된다. 넓은 관심영역을 추출하기 위해 반지름 r이 큰 검색영역 내에서의 대칭성이 추출될 필요가 있다. 이에 따라서 GST의 수행시간은 r에 따라 2차적으로 증가하게 된 본 논문에서는 이를 개선하기 위해 선택적 방향 주의를 가지는 수정된 스캔라인 GST를 제안한다. 제안된 GST는 기존의 GST와 유사한 대칭 특성을 추출하지만 선택적 방향의 기울기만을 고려한 스캔라인 위의 에지 화소쌍에서 GST를 수행함으로써 r에 따라서 이의 수행시간이 선형적으로 증가된다 특히 r이 큰 경우에 선택적 방향에 대해서만 적용하면 기존의 GST의 계산량이 비대해지는 단점을 보완해 줄 수 있다. 제안된 GST가 기존의 GST보다 시간적으로 효과적이며 유용하다는 것이 여러 종류의 영상에 대한 실험으로 확인되었다.

  • PDF

모바일 유압장치에서 부하의 유지와 내림 특성 비교 (Analysis of Characteristics of Load Movement in Mobile Hydraulic Equipment)

  • 조미현;허준영
    • 드라이브 ㆍ 컨트롤
    • /
    • 제15권4호
    • /
    • pp.17-22
    • /
    • 2018
  • Mobile hydraulics require higher energy efficiency, and a simpler as well as robust design, than general industrial hydraulics. The 6/3-way directional control valve is widely used as a mobile hydraulic control valve. However, since the 6/3-way directional control valve is a spool type valve, it is difficult to maintain the load. A counterbalance valve is typically used, to maintain the load, and lift down. However, in an industrial field using a mobile hydraulics device, a pilot controlled check valve may be used to implement holding and lifting operation of the self-weight load, and a relief valve may be used simply to exert back pressure. But no comparative analysis of advantages and disadvantages of each method was revealed. In this study, various methods of holding and unloading load with self-weight in mobile hydraulics are investigated, and compared through simulation using AMESim software. This is experimentally verified by using Festo's mobile hydraulic test rig TP800.

전완부(前腕部) 경혈(經穴) 취혈(取穴)에서 골도분촌법(骨度分寸法)과 일부법(一夫法)의 비교(比較) 연구(硏究) (Comparative study between proportional method and directional method in locating acupoints at forearm)

  • 박히준;채윤병;차웅석;박종배;이혜정;이향숙;인창식;고형균;김수영;최일환;김강식;문정배;배기태;유경환;육근영;정병주;손인철;임사비나
    • Korean Journal of Acupuncture
    • /
    • 제21권4호
    • /
    • pp.31-41
    • /
    • 2004
  • Background : The cun measurement system, an essential and convenient method in locating acupoints, has been widely used in the practice of acupuncture. However, traditional cun measurement has been criticized for its lack of reliability. Objectives : The purposes of this study are to determine if one cun measured by the directional methods have a consistency with that of proportional methods and to investigate which factors are related with these differences, especially in forearm. Methods : The distance between the elbow crease and the wrist crease of forearm was compared to a reference value of one cun obtained by the directional method. In this method, one cun is one third of the distance between index finger and small finger of a subject, measured at proximal interphalangeal joint. In addition, to investigate the factors influencing the differences between these two methods, we measured the height and body weight and calculated body mass index (BMI). Finally we analyzed the factors correlated with these lengths by linear regression test. Results : The results showed that one cun obtained by the directional methods were significantly different from one cun by the proportional methods in forearm. It was demonstrated that the length acquired with the directional method was more correlated with body weight and body mass index, while the length obtained by the proportional method was more correlated with the height. Conclusion : These findings suggest that the directional method is less likely dependable in locating acupoints than the proportional method because the influencing factors are different.

  • PDF

Effect on the Limit of Stability of the Lowered Center of Mass With a Weight Belt

  • Phan, Jimmy;Wakumoto, Kaylen;Chen, Jeffrey;Choi, Woochol Joseph
    • 한국전문물리치료학회지
    • /
    • 제27권2호
    • /
    • pp.155-161
    • /
    • 2020
  • Background: The consequences of falls are often debilitating, and prevention is important. In theory, the lower the center of mass (COM), the greater postural stability during standing, and a weight belt at the waist level may help to lower the COM and improve the standing balance. Objects: We examined how the limit of stability (LOS) was affected by the lowered center of mass with the weight belt. Methods: Twenty healthy individuals participated in the LOS test. After calculating each participant's COM, a weight belt was fastened ten centimeters below the COM. Trials were acquired with five weight belt conditions: 0%, 2%, 4%, 6%, and 8% of body weight. Outcome measures included reaction time, movement velocity, endpoint excursion, maximum excursion, and directional control in 4 cardinal moving directions. Results: None of our outcome variables were associated with a weight belt (p > 0.075), but all of them were associated with moving direction (p < 0.01). On average, movement velocity of the COM and maximum excursion were 31% and 18% greater, respectively, in mediolateral than anteroposterior direction (5.4°/s vs. 4.1°/s; 97.5% vs. 82.6%). Conclusion: Our results suggest that postural stability was not affected by the weight-induced lowered COM, informing the development and improvement of balance training strategies.

초음파 바이오텔레메터리를 이용한 어류의 추적기술 (Tracking Technology of Fish by an Ultrasonic Biotelemetry System)

  • 박주삼
    • 수산해양교육연구
    • /
    • 제19권3호
    • /
    • pp.478-490
    • /
    • 2007
  • A technology of ultrasonic biotelemetry for tracking fish behavior is investigated. The ultrasonic biotelemetry system is constituted by a transmitter and a receiving system. Because a pinger was mainly used for the transmitter, the capability for pinger to possess was investigated and the efficient usage for pinger was examined. A source pressure level and a frequency were synthetically examined so that pinger could realize small size, a light weight, and a long life time. The receiving system is divided roughly into directional hydrophone systems and acoustic positioning systems by the receiving method. The directional hydrophone system is divided into single beam and multiple beam with the number of hydrophone, and the acoustic positioning systems is divided into LBL (Long Base Line), SBL (Short Base Line), and SSBL (Super Short Base Line) on the basis of base line. The present situation, the merits and demerits, and the principle of each receiving method were investigated in detail, and the efficient usage for each receiving method were examined.

접촉 형상과 기구학적 운동형태가 초고분자량 폴리에틸렌의 마멸에 미치는 영향 (Effects of Kinematic Motions and Contact Configurations on the Wear of UHMWPE)

  • 이권용
    • Tribology and Lubricants
    • /
    • 제18권2호
    • /
    • pp.143-146
    • /
    • 2002
  • The effects of contact configuration and kinematic motion on the wear of ultrahigh molecular weight polyethylene (UHMWPE) were investigated. Two different contact configurations were adopted for wear testing under the two different kinematic motions with un-irradiated UHMWPE specimens. Wear of UHMWPE pins against the linear reciprocating stainless steel disks was 8% higher than that against the uni-directional repeat pass rotating disks. Wear of UHMWPE disks moving in the linear reciprocating motion against stainless steel ball was 37% higher than that moving in the uni-directional repeat pass rotating motion. The results in this study show that the contact configuration and kinematic motion of sliding definitely affect the wear of UHMWPE through the differences in the contact stress states of UHMWPE.

접촉 형상과 기구학적 운동형태가 초고분자량 폴리에틸렌의 마멸에 미치는 영향 (Effects of Kinematic Motions and Contact configurations on the Wear of UHMWPE)

  • 이권용
    • 한국윤활학회:학술대회논문집
    • /
    • 한국윤활학회 2001년도 제33회 춘계학술대회 개최
    • /
    • pp.100-104
    • /
    • 2001
  • The effects of contact configuration and kinematic motion on the wear of ultrahigh molecular weight polyethylene (UHMWPE) were investigated. Two different contact configurations were adopted for wear testing under the two different kinematic motions with un-irradiated UHMWPE specimens. Wear of UHMWPE pins against the linear reciprocating stainless steel disks was 8% higher than that against the uni-directional repeat pass rotating disks. Wear of UHMWPE disks moving in the linear reciprocating motion against stainless steel ball was 37% higher than that moving in the uni-directional repeat pass rotating motion. The results in this study show that the contact configuration and kinematic motion of sliding definitely affect the wear of UHMWPE through the differences in the contact stress states of UHMWPE.

  • PDF