• Title/Summary/Keyword: Directional Weight

Search Result 89, Processing Time 0.03 seconds

A Modular Bi-Directional Power Electronic Transformer

  • Gao, Zhigang;Fan, Hui
    • Journal of Power Electronics
    • /
    • v.16 no.2
    • /
    • pp.399-413
    • /
    • 2016
  • This paper presents a topology for a modular power electronic transformer (PET) and a control scheme. The proposed PET consists of a cascaded H-Bridge rectifier on the primary side, a high-frequency DC/DC conversion cell in the center, and a cascaded H-Bridge inverter on the secondary side. It is practical to use PETs in power systems to reduce the cost, weight and size. A detailed analysis of the structure is carried out by using equivalent circuit. An algorithm to control the voltages of each capacitor and to maintain the power flow in the PET is established. The merits are analyzed and verified in theory, including the bi-directional power flow, variable voltage/frequency and high power factor on the primary side. The experimental results validated the propose structure and algorithm.

Directional Asymmetry of Gonadal Development in Ayu (Plecoglossus altivelis)

  • Park In-Seok;Zhang Chang Ik;Kim Young Ja;Bang In Chul
    • Fisheries and Aquatic Sciences
    • /
    • v.8 no.4
    • /
    • pp.207-212
    • /
    • 2005
  • Directional (sinistral) asymmetry (DA) occurs when the traits of one side of a supposedly bilaterally symmetrical organism differ in a random way from those of the other side. We examined asymmetries in gonadal growth traits within both sexes of hatchery reared ayu, Plecoglossus altivelis. The pattern of the gonadal growth from hatching to 320 days after hatching was a type of DA except for the growth in gonad weight from 140 to 180 days after hatching, although the ovary of the right side tended to exhibit more pronounced DA phenomenon.

Effect of Vestibular Sensory Stimulation Exercise on Limit of Stability, Dynamic Weight Shift, and Upper and Lower Extremities Reaction Time in Adult Women (안뜰감각 자극운동이 성인여성의 안정성한계, 동적체중이동 및 팔다리 반응시간에 미치는 영향)

  • Kim, Chung-Yoo;Lee, Keon-Cheol;Lee, Yeon-Seop
    • Journal of The Korean Society of Integrative Medicine
    • /
    • v.10 no.2
    • /
    • pp.203-210
    • /
    • 2022
  • Purpose : The purpose of this study was to investigate the effect of vestibular sensory stimulation exercise on the limit of stability, dynamic weight shift, and upper and lower extremities reaction time in adult women. Methods : This study was conducted with 30 female. All subjects were randomly and equally assigned to an experimental group and a control group of 15 each. Subjects assigned to the experimental group received vestibular sensory stimulation training for 6 weeks. For the intervention, vestibular sensory stimulation exercises were conducted by referring to the Hamid exercise method and the Cawthorne-Cooksey exercise method, and the control group did not receive any intervention. All subjects were tested for limit of stability, dynamic weight shift, and upper and lower extremities reaction time before and after the intervention. Results : The results of this study showed significant differences between groups in reaction time, moving velocity, and directional control in the limit of stability test after intervention. In the dynamic weight shift test after intervention, there was a significant difference between the groups in the slow directional control of left and right. And in the upper and lower extremities reaction time test after intervention, both scores and reaction time showed significant differences between groups. Conclusion : As a result, the three vestibular sensory stimulation exercises applied in this study improved the limit of stability, dynamic weight shift, and upper and lower extremities reaction time.

Modified Scan Line Based Generalized Symmetry Transform with Selectively Directional Attention (선택적 방향주의를 가지는 수정된 스캔라인 일반화 대칭 변환)

  • Kim, Dong-Su;Jin, Seong-Il
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.38 no.4
    • /
    • pp.411-421
    • /
    • 2001
  • The generalized symmetry transform evaluates symmetry without segmentation and extracts regions of interest in an image by combining locality and reflectional symmetry The demand that the symmetry transform be local is reflected by the distance weight function. When calculating large regions-of-interest, we should select a large standard deviation of distance weight function. But such a large standard deviation makes the execution time increase in the second power of r, which is a radius of search area. In this paper we propose modified scan line based GST with selectively directional attention to improve time complexity The symmetry map of our proposed GST is found to be very similar to that of the existing GST. However the computation time of the proposed GST increases linearly with respect to r because our proposed GST evaluates symmetry between a pair of edge pixels along the scan lines. The GST computation decreases considerably when the proposed GST is peformed with selectively directional attention in case of large r. Several experiments in this paper demonstrate the time efficiency and the usefulness of our proposed GST.

  • PDF

Analysis of Characteristics of Load Movement in Mobile Hydraulic Equipment (모바일 유압장치에서 부하의 유지와 내림 특성 비교)

  • Jo, Mi Hyeon;Huh, Jun Young
    • Journal of Drive and Control
    • /
    • v.15 no.4
    • /
    • pp.17-22
    • /
    • 2018
  • Mobile hydraulics require higher energy efficiency, and a simpler as well as robust design, than general industrial hydraulics. The 6/3-way directional control valve is widely used as a mobile hydraulic control valve. However, since the 6/3-way directional control valve is a spool type valve, it is difficult to maintain the load. A counterbalance valve is typically used, to maintain the load, and lift down. However, in an industrial field using a mobile hydraulics device, a pilot controlled check valve may be used to implement holding and lifting operation of the self-weight load, and a relief valve may be used simply to exert back pressure. But no comparative analysis of advantages and disadvantages of each method was revealed. In this study, various methods of holding and unloading load with self-weight in mobile hydraulics are investigated, and compared through simulation using AMESim software. This is experimentally verified by using Festo's mobile hydraulic test rig TP800.

Comparative study between proportional method and directional method in locating acupoints at forearm (전완부(前腕部) 경혈(經穴) 취혈(取穴)에서 골도분촌법(骨度分寸法)과 일부법(一夫法)의 비교(比較) 연구(硏究))

  • Park, Hi-Joon;Chae, Youn-Byoung;Cha, Wung-Seok;Park, Jong-Bae;Lee, Hye-Jung;Lee, Hyang-Sook;Yin, Chang-Sik;Koh, Hyung-Kyun;Kim, Su-Young;Choe, Il-Hwan;Kim, Kang-Sik;Moon, Jung-Bae;Bae, Ki-Tae;Rheu, Kyoung-Hwan;Yook, Keun-Yung;Jeong, Byeong-Ju;Sohn, In-Chul;Lim, Sabina
    • Korean Journal of Acupuncture
    • /
    • v.21 no.4
    • /
    • pp.31-41
    • /
    • 2004
  • Background : The cun measurement system, an essential and convenient method in locating acupoints, has been widely used in the practice of acupuncture. However, traditional cun measurement has been criticized for its lack of reliability. Objectives : The purposes of this study are to determine if one cun measured by the directional methods have a consistency with that of proportional methods and to investigate which factors are related with these differences, especially in forearm. Methods : The distance between the elbow crease and the wrist crease of forearm was compared to a reference value of one cun obtained by the directional method. In this method, one cun is one third of the distance between index finger and small finger of a subject, measured at proximal interphalangeal joint. In addition, to investigate the factors influencing the differences between these two methods, we measured the height and body weight and calculated body mass index (BMI). Finally we analyzed the factors correlated with these lengths by linear regression test. Results : The results showed that one cun obtained by the directional methods were significantly different from one cun by the proportional methods in forearm. It was demonstrated that the length acquired with the directional method was more correlated with body weight and body mass index, while the length obtained by the proportional method was more correlated with the height. Conclusion : These findings suggest that the directional method is less likely dependable in locating acupoints than the proportional method because the influencing factors are different.

  • PDF

Effect on the Limit of Stability of the Lowered Center of Mass With a Weight Belt

  • Phan, Jimmy;Wakumoto, Kaylen;Chen, Jeffrey;Choi, Woochol Joseph
    • Physical Therapy Korea
    • /
    • v.27 no.2
    • /
    • pp.155-161
    • /
    • 2020
  • Background: The consequences of falls are often debilitating, and prevention is important. In theory, the lower the center of mass (COM), the greater postural stability during standing, and a weight belt at the waist level may help to lower the COM and improve the standing balance. Objects: We examined how the limit of stability (LOS) was affected by the lowered center of mass with the weight belt. Methods: Twenty healthy individuals participated in the LOS test. After calculating each participant's COM, a weight belt was fastened ten centimeters below the COM. Trials were acquired with five weight belt conditions: 0%, 2%, 4%, 6%, and 8% of body weight. Outcome measures included reaction time, movement velocity, endpoint excursion, maximum excursion, and directional control in 4 cardinal moving directions. Results: None of our outcome variables were associated with a weight belt (p > 0.075), but all of them were associated with moving direction (p < 0.01). On average, movement velocity of the COM and maximum excursion were 31% and 18% greater, respectively, in mediolateral than anteroposterior direction (5.4°/s vs. 4.1°/s; 97.5% vs. 82.6%). Conclusion: Our results suggest that postural stability was not affected by the weight-induced lowered COM, informing the development and improvement of balance training strategies.

Tracking Technology of Fish by an Ultrasonic Biotelemetry System (초음파 바이오텔레메터리를 이용한 어류의 추적기술)

  • Park, Ju-Sam
    • Journal of Fisheries and Marine Sciences Education
    • /
    • v.19 no.3
    • /
    • pp.478-490
    • /
    • 2007
  • A technology of ultrasonic biotelemetry for tracking fish behavior is investigated. The ultrasonic biotelemetry system is constituted by a transmitter and a receiving system. Because a pinger was mainly used for the transmitter, the capability for pinger to possess was investigated and the efficient usage for pinger was examined. A source pressure level and a frequency were synthetically examined so that pinger could realize small size, a light weight, and a long life time. The receiving system is divided roughly into directional hydrophone systems and acoustic positioning systems by the receiving method. The directional hydrophone system is divided into single beam and multiple beam with the number of hydrophone, and the acoustic positioning systems is divided into LBL (Long Base Line), SBL (Short Base Line), and SSBL (Super Short Base Line) on the basis of base line. The present situation, the merits and demerits, and the principle of each receiving method were investigated in detail, and the efficient usage for each receiving method were examined.

Effects of Kinematic Motions and Contact Configurations on the Wear of UHMWPE (접촉 형상과 기구학적 운동형태가 초고분자량 폴리에틸렌의 마멸에 미치는 영향)

  • 이권용
    • Tribology and Lubricants
    • /
    • v.18 no.2
    • /
    • pp.143-146
    • /
    • 2002
  • The effects of contact configuration and kinematic motion on the wear of ultrahigh molecular weight polyethylene (UHMWPE) were investigated. Two different contact configurations were adopted for wear testing under the two different kinematic motions with un-irradiated UHMWPE specimens. Wear of UHMWPE pins against the linear reciprocating stainless steel disks was 8% higher than that against the uni-directional repeat pass rotating disks. Wear of UHMWPE disks moving in the linear reciprocating motion against stainless steel ball was 37% higher than that moving in the uni-directional repeat pass rotating motion. The results in this study show that the contact configuration and kinematic motion of sliding definitely affect the wear of UHMWPE through the differences in the contact stress states of UHMWPE.

Effects of Kinematic Motions and Contact configurations on the Wear of UHMWPE (접촉 형상과 기구학적 운동형태가 초고분자량 폴리에틸렌의 마멸에 미치는 영향)

  • 이권용
    • Proceedings of the Korean Society of Tribologists and Lubrication Engineers Conference
    • /
    • 2001.06a
    • /
    • pp.100-104
    • /
    • 2001
  • The effects of contact configuration and kinematic motion on the wear of ultrahigh molecular weight polyethylene (UHMWPE) were investigated. Two different contact configurations were adopted for wear testing under the two different kinematic motions with un-irradiated UHMWPE specimens. Wear of UHMWPE pins against the linear reciprocating stainless steel disks was 8% higher than that against the uni-directional repeat pass rotating disks. Wear of UHMWPE disks moving in the linear reciprocating motion against stainless steel ball was 37% higher than that moving in the uni-directional repeat pass rotating motion. The results in this study show that the contact configuration and kinematic motion of sliding definitely affect the wear of UHMWPE through the differences in the contact stress states of UHMWPE.

  • PDF