• Title/Summary/Keyword: Directional Difference

Search Result 229, Processing Time 0.029 seconds

A Design of Microstrip Directional Coupler with the Improved Directivity Characteristic (개선된 지향성을 갖는 마이크로스트립 방향성 결합기 설계)

  • Kim, Chul-Soo;Lim, Jong-Sik;Kim, Dong-Joo;Ahn, Dal
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.15 no.6
    • /
    • pp.548-553
    • /
    • 2004
  • In this paper, single, two, and three-section microstrip directional couplers are implemented for realizing the high directivity characteristics. The achievement of the high directivity with microstrip configuration is carried out by the distributed capacitor to decrease the even and odd mode phase difference. Capacitive compensation is performed by gap coupling of open stub formed in sub-coupled line. Therefore, insertion loss and power handling capability are not affected by the gap coupling. The proposed structure is easy to fabricate and incorporate another microwave device due to the planner microstrip. We designed and fabricated single, two, and three-section directional coupler with 20 ㏈ coupling. In spite of microstrip structure, the capacitive compensation structure shows 30 ㏈, 27 ㏈, and 25 ㏈ of directivity in single, two, and three-section directional couplers, respectively.

Design of Omni-directional Reflector for Synthetic Aperture Radar (합성개구레이더용 전방향 반사기의 설계)

  • Chang, Geba;Oh, Yi-Sok;Yang, Chan-Su
    • Korean Journal of Remote Sensing
    • /
    • v.23 no.6
    • /
    • pp.501-506
    • /
    • 2007
  • Basic research is conducted to identify a target using corner reflectors which are commonly used in calibration of synthetic aperture radar (SAR) systems. At first, an omni-directional reflector is fabricated by combining four 15-cm rectangular trihedral corner reflectors. Then, its radar cross section (RCS) characteristics are measured at C-band (5.3 GHz) for vv-, hh-, hv-, and vh- polarizations at a range of horizontal angle, $-90^{\circ}{\le}{\phi}{\le}90^{\circ}$. The measured RCS angular variation of the omni-directional reflector is much smaller for vv-polarization than other polarizations, and the difference between the maximum and minimum RCSs for vv-polarization is about 8 dB. Peak RCS values are shown at $0^{\circ}$ (normal to plates) and $45^{\circ}$ (direction of bore sight). It is shown that the measurements agree quite well with numerical simulation and theoretical computation results.

Reproducibility of Mandibular Eccentric Movements in Patients with Temporomandibular Disorders (측두하악장애환자에서 하악의 편심운동재현성에 관한 연구)

  • 서명석;한경수
    • Journal of Oral Medicine and Pain
    • /
    • v.22 no.2
    • /
    • pp.295-307
    • /
    • 1997
  • This study was performed to investigate the reproductibility of eccentric mandibular movements according to preferred chewing side, range of mouth opening, type of lateral guidance and involvement of temporomandibular disorders. 50 patients with temporomandibular disorders and 65 dental students without any signs and symptoms were randomly selected for this study as the patients group and the control group, respectively. For recording and observation of eccentric mandibular movement trajectory, BioEGN$^\textregistered$ of Biopak$^\textregistered$ system (Bioresearch Inc., USA) was used. Each eccentric movement to anterior, right and left side was performed three times similar to the movement pattern for Pantronic Reproducibility Index. mandibular path was analyzed by three dimensional positional change and the three paths from one direction were compared with one another. From this, reproducibility index of one-directional lateral movement could be calculated, and total reproducibility index, named BioEGN reproducibility index(BERI), was also computed from three-directional eccentric movement likewise. BioEGN reproducibility Index could have four value of score by small or large scale, and by outgoing or incoming movement. The data were analyzed by SAS/stat program and the results obtained were as follows: 1. Right side chewing subjects showed more consistent pattern In reproducibility index in comparison between patients group and control group than left chewing subjects have done, and reproducibility was low in patients group. However, there was no difference between the two stoups in bilateral chewing subjects. 2. There were no difference in reproducibility index between preferred chewing side and contralateral side in unilateral chewing subjects whereas reproducibility index in left side on outgoing movement were higher than in right side in bilateral chewing subjects. 3. Difference in total reproducibility index(BERI) between canine guidance group and non-canine guidance group were not observed though difference in reproducibility index on lateral movement were observed in part. 4. There were no difference in reproducibility index between affected side and contralateral side in unilaterally affected patients, and between unilaterally affected patients and bilaterally affected patients in patients group. 5. Highly significant positive correlationship were shown among the four 쇼pes of total reproducibility index(BERI) in total subjects, and range of clinical mouth opening was negatively correlated with BEBI on outgoing movements and with index on outgoing movement to preferred side.

  • PDF

Design of ultraprecision hi-directional actuator for nm using a permanent magnet and electromagnet (영구 자석과 전자석의 상호작용을 이용한 초정밀 양방향 구동기 설계)

  • Kim Ki-Hyun;Gweon Dae-Gab
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.22 no.9 s.174
    • /
    • pp.147-154
    • /
    • 2005
  • A precision hi-directional actuator for a high precision leveling system with $Z{\Theta}_x{\Theta}_y$ motions is proposed and designed in this paper. The actuator is composed of a force generation structure, a guide mechanism, and a symmetric structure. At first, its driving force is generated by a change of flux in air gaps by permanent and changeable flux. The permanent flux is generated by a permanent magnet. The changeable flux is created by variable current flowing through coil. The combination of permanent and changeable flux makes various flux densities in air gaps between moving part and fixed yokes. And then, the difference between flux densities in lower and upper gaps creates forces fur the $bi-direction({\pm}z)$ motion. The guide mechanism of this actuator is composed of two circular plates and one shaft. Reducing motions generated by forces except z-motion, these circular plates endow the actuator with high stiffness for fast settling time. And the function of the shaft is to transfer motion to an object. At last, total body has a symmetric structure to be stable on thermal error. The actuator is designed by MAXWELL 2D and ProMECHANICA. The designed actuator is evaluated by 8nm laser doppler vibrometer, dynamic signal analyzer, and simple PID controller.

THREE-DIMENSIONAL FINI6E ELEMENT ANALYSIS OF THE ENDOSSEOUS IMPLANT DESIGNS (삼차원 유한요소 해석에 의한 골내 임프란트의 구조에 관한 연구)

  • Hyun, Young-Keun;Kwon, Jong-Jin
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.35 no.1
    • /
    • pp.181-210
    • /
    • 1997
  • The stress distribution generated in the surrounding bone was calculated and compared for various geometry of the dental implants by means of the finite element methods. The models were designed to represent the screw type endosseous implants(varing the size, shape, direction of the screw thread and the angle of the body) with supporting bone and the cylinder type endosseous implants(varing the lower portion-Round type, tapered type) with supporting bone. Static mean bite forces were applied 100N vertically and 25N horizontally on the center of the implant and three dimensional finite analysis was undertaken using software ANSYS 5.1 Version. The result demonstrated that different implant shape leads to significant variations in stress distribution in the bone. In the case of variation of the screw size, direction and shape the implant model with normally directional and triangular screw implied lower stress than with upper directional or lower directional and quadrangular screw but among models a different screw size, within a variation of 0.2mm there was no meaningful difference in maximum stress. In the case of variation of angle of body the straight implied lower stress than the tapered. As a result of analysis of cylinder type, the implants with larger radius of curvature of the round form and larger diameter of the tapered form implied lower stress.

  • PDF

VALVELESS PUMPING IN OPEN TANK SYSTEM USING ENERGY CONSERVING COMPARTMENT MODEL

  • Jung, Eun-Ok;Kim, Do-Wan
    • Bulletin of the Korean Mathematical Society
    • /
    • v.49 no.5
    • /
    • pp.961-987
    • /
    • 2012
  • A compartment model of the flow driven by pumping without valves (valveless pumping) in an open tank system is proposed. By the open tank system, we mean that two rigid cylindrical tanks are connected with an elastic tube. An incompressible fluid fills this system up to a certain level in tanks under the gravity. The compartment model for analyzing such open system is derived from the energy principle which will be called the energy conserving compartment model or shortly the ECCM. Based on this ECCM of valveless pumping, we explore the occurrence of directional net flow or directional net power by a specific excitation at an asymmetric part of the elastic tube. The interaction between deformable elastic tube and the fluid inside is considered in the ECCM. The reliability of the ECCMis investigated through some physical examples. The ECCM shows the existence of directional net power of the valveless pump system with open tanks and confirms that the direction and magnitude of the net power depend on the pumping frequency as well. Furthermore, the phase synchronization in time between the fluid pressure difference and the external pinching force over the pumping region is highly related to the direction of energy storing or net power.

A Study on the application for Z-Quality steel (Z-Quality 강재 적용에 대한 고찰)

  • Park, Sungjun;Ha, Yunsok
    • Special Issue of the Society of Naval Architects of Korea
    • /
    • 2017.10a
    • /
    • pp.8-13
    • /
    • 2017
  • The rolled carbon steel plate has anisotropic property in Z-direction(thickness direction). This is induced by cooling rate difference of Z-direction and sulfur which make non-metallic inclusion(MnS) at center line of thickness direction. Z-directional mechanical properties of normal steel plate are not generally specified and it is defined for Z-Quality steel only through tensile test in Z-direction. If Z-quality steel is not applied for cruciform joint, the lamella tearing will be occurred by tensile stress after welding & during operation of the structure. In this research, one equation estimating Z-directional(orthogonal to plate) stress was developed to prevent lamella tearing by welding. This equation deals with plate thickness & joint configuration(eccentricity, angle and curvature). Analyses were done by strain boundary method using sectional FE modeling and FE 3D models are also used for some cases. Designers can predict the possibility of lamella tearing by adequately applying the result and can appropriately minimize the application of Z-quality steel by revising welding design to some extent.

  • PDF

Segmentation by Contour Following Method with Directional Angle

  • Na, Cheol-Hun;Kim, Su-Yeong;Kang, Seong-Jun
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2012.10a
    • /
    • pp.874-877
    • /
    • 2012
  • This paper proposes the new method based on contour following method with directional angle to segment the cell into the nuclei. The object image was the Thyroid Gland cell image that was diagnosed as normal and abnormal(two types of abnormal : follicular neoplastic cell, and papillary neoplastic cell), respectively. The nuclei were successfully diagnosed as normal and abnormal. this paper, improved method of digital image analysis required in basic medical science for diagnosis of cells was proposed. The object image was the Thyroid Gland cell image with difference of chromatin patterns. To segment the cell nucleus from background, the region segmentation algorithm by edge tracing was proposed. And feature parameter was obtained from discrete Fourier transformation of image. After construct a feature sample group of each cells, experiment of discrimination was executed with any verification cells. As a result of experiment using features proposed in this paper, get a better segmentation rate(70-90%) than previously reported papers, and this method give shape to get objectivity and fixed quantity in diagnosis of cells. The methods described in this paper be used immediately for discrimination of neoplastic cells.

  • PDF

Context-Based Minimum MSE Prediction and Entropy Coding for Lossless Image Coding

  • Musik-Kwon;Kim, Hyo-Joon;Kim, Jeong-Kwon;Kim, Jong-Hyo;Lee, Choong-Woong
    • Proceedings of the Korean Society of Broadcast Engineers Conference
    • /
    • 1999.06a
    • /
    • pp.83-88
    • /
    • 1999
  • In this paper, a novel gray-scale lossless image coder combining context-based minimum mean squared error (MMSE) prediction and entropy coding is proposed. To obtain context of prediction, this paper first defines directional difference according to sharpness of edge and gradients of localities of image data. Classification of 4 directional differences forms“geometry context”model which characterizes two-dimensional general image behaviors such as directional edge region, smooth region or texture. Based on this context model, adaptive DPCM prediction coefficients are calculated in MMSE sense and the prediction is performed. The MMSE method on context-by-context basis is more in accord with minimum entropy condition, which is one of the major objectives of the predictive coding. In entropy coding stage, context modeling method also gives useful performance. To reduce the statistical redundancy of the residual image, many contexts are preset to take full advantage of conditional probability in entropy coding and merged into small number of context in efficient way for complexity reduction. The proposed lossless coding scheme slightly outperforms the CALIC, which is the state-of-the-art, in compression ratio.