• Title/Summary/Keyword: Direction of rotation

Search Result 698, Processing Time 0.034 seconds

A Design Optimization of Asymmetric Air-gap Structure for Small 3-phase Permanent Magnet SPM BLDC Motor

  • Kam, Seung-Han;Jung, Tae-Uk
    • Journal of Magnetics
    • /
    • v.20 no.1
    • /
    • pp.91-96
    • /
    • 2015
  • As many researchers are relentlessly trying to improve the power generation schemes from the power grid, to meet the constantly increasing electricity demand. In this paper, the results of a finite element analysis are carried out to study on a design optimization of an asymmetric air-gap structure in 3-phase Permanent Magnet Brushless DC Motors. To achieve a high efficiency for a 3-phase PM BLDC motor, the asymmetric air-gap structure is proposed considering the rotation direction of a motor. Generally, a single-phase BLDC motor is applied asymmetric air-gap structure for starting. This is because the asymmetric air-gap structure causes reluctance variation so the motor can utilize reluctance torque toward a rotation direction. In this paper, the asymmetric air-gap is applied to 3-phase BLDC SPM motor so it utilizes reluctance torque with alignment torque. A proposed model is designed by 2-D FE analysis and the results are verified by experimental test.

A study on the development of CW(Continuous-Wave) Doppler system for measuring bi-directional blood flow information. (혈류 방향을 구별하는 연속 초음파 도플러 장치에 관한 연구)

  • Kang, Chung-Sin;Kim, Young-Kil
    • Proceedings of the KIEE Conference
    • /
    • 1987.07b
    • /
    • pp.1239-1242
    • /
    • 1987
  • With the convention CW Doppler velocity meter, bi-directional velocities cannot be separated. The new CW Doppler system usee quadrature detection and phase rotation to Produce simultaneous independent audio and velocity signals for forward and reverse blood flow direction, is fabricated. Specially, this system shows that phase rotation method for flow direction separation provides easy and satisfactory feature. From in vivo blood flow measurement, can easily differentiate typical artery flow from vein flow. and measure both velocity characteristics qualitatively.

  • PDF

Regulation of Star Formation in Turbulent, Multiphase Interstellar Media

  • Kim, Chang-Goo;Kim, Woong-Tae;Ostriker, Eve C.
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.35 no.1
    • /
    • pp.66.1-66.1
    • /
    • 2010
  • Using two-dimensional numerical hydrodynamic simulations, we investigate the star formation rate (SFR) in turbulent, multiphase, galactic gaseous disks. Our simulation domain is axisymmetric, and local in the radial direction and global in the vertical direction. Our models include galactic rotation, vertical density stratification, self-gravity, radiative heating and cooling, and thermal conduction, but do not include spiral-arm features. Turbulence in our models is driven by momentum feedback from supernova explosion events occurring in localized dense regions formed by thermal and gravitational instabilities. Self-consistent radiative heating, representing enhanced/reduced FUV photons from the star formation, is also taken into account. By controlling three parameters (the gas surface density, the stellar disk density, and the angular rotation rate) that characterize local galactic disks, we explore how the SFR depends on the background environmental state. We also discuss the relation between the SFR and the gas surface density found in our numerical models in comparison with observations.

  • PDF

The Effects of Corneal Eccentricity and Shape on Toric Soft Lens Rotation by Change of Postures (이심률 및 각막형상이 자세변화에 의한 토릭소프트렌즈의 회전에 미치는 영향)

  • Kim, So Ra;Hahn, Shin Woong;Song, Ji Soo;Park, Mijung
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.18 no.4
    • /
    • pp.449-456
    • /
    • 2013
  • Purpose: The present study aimed to investigate the effects of corneal eccentricity and shape on the rotational pattern of toric soft lens by the postural change of lens wearers. Methods: The corneal eccentricity of 41 eyes (aged 20s) having -1.0 D with-the-rule corneal astigmatism (WRCA) was measured, and then toric soft lenses were fitted with the amount of total astigmatism. In lying and straight postures, the rotation of toric soft lenses was recorded by a camera attached to slitlamp and analyzed. Results: Most toric soft lens designed with accelerated stabilization rotated to the temporal direction, which was the lying position direction, regardless of corneal eccentricity, and some lenses rotated to the nasal direction for high corneal eccentricity and corneal type of asymmetric bowtie. There was no correlation between the amount of rotation and corneal eccentricity right after of contact lens wearing in straight and lying posture, however, the amount of rotation was the greater for the cornea with the higher eccentricity after the subjects laying down for some period. The speed of lens rotation started to decrease after the subjects laying down, but the speed was not different according to corneal eccentricity difference. The amount of lens rotation for symmetric and asymmetric bowtie-typed corneas increased more than it for oval-typed cornea, and it was same even with time elapsing. The speed of lens rotation in lying posture was the slowest in asymmetric bowtie-typed cornea compared with other corneal types. Conclusions: From the present study, it was revealed that the rotational pattern of toric soft lens was affected by corneal eccentricity and corneal shape when the wearer's posture changed. Thus, it should be considered for the development of the fitting guideline and the design of toric soft lens.

Biomechanical Effects of Facial Mask according to Direction of Forces on the Craniofacial Complex : A Finite Element Study (두개안면복합체에서 Face Mask의 견인방향에 따른 생역학적 연구 : 유한요소법 연구)

  • Hyun, Ha-Young;Cha, Kyung-Suk;Chung, Dong-Hwa
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.23 no.4
    • /
    • pp.359-371
    • /
    • 2007
  • Recently, many studies were reported accurate analysis of facemask effect due to the development of the personal computers and computer programs. The aim of this study is appropriate protraction direction of facemask using finite element study with computer aided design and computer aided measurement. The construction of the three dimensional FEM was based on the computer tomography(CT) scans of 13.5 year-old male subject. Protraction force of 500 mg was applied at 0, 30, 60 and 90 degrees downwards to the Frankfort horizontal plane, and maxillary displacement and stress distribution were measured. When 60 degree force was applied, it showed forward movement of premolar roots area and downward movement of anterior nasomaxillary area, and others showed clockwise rotation movement of the nasomaxillary complex. Finally, we can produce the protraction of maxillary bone without rotation of maxilla about 60 degrees.

Slip Detection and Control Algorithm to Improve Path Tracking Performance of Four-Wheel Independently Actuated Farming Platform (4륜 독립구동형 농업용 플랫폼의 주행 궤적 추종 성능 향상을 위한 휠 슬립 검출 및 보상제어 알고리즘 연구)

  • Kim, Bongsang;Cho, Sungwoo;Moon, Heechang
    • The Journal of Korea Robotics Society
    • /
    • v.15 no.3
    • /
    • pp.221-232
    • /
    • 2020
  • In a four-wheel independent drive platform, four wheels and motors are connected directly, and the rotation of the motors generates the power of the platform. It uses a skid steering system that steers based on the difference in rotational power between wheel motors. The platform can control the speed of each wheel individually and has excellent mobility on dirt roads. However, the difficulty of the straight-running is caused due to torque distribution variation in each wheel's motor, and the direction of rotation of the wheel, and moving direction of the platform, and the difference of the platform's target direction. This paper describes an algorithm to detect the slip generated on each wheel when a four-wheel independent drive platform is traveling in a harsh environment. When the slip is detected, a compensation control algorithm is activated to compensate the torque of the motor mounted on the platform to improve the trajectory tracking performance of the platform. The four-wheel independent drive platform developed for this study verified the algorithm. The wheel slip detection and the compensation control algorithm of the platform are expected to improve the stability of trajectory tracking.

The Studies on the Foot Stability and Kinesiology by Direction of Carry a Load during Gait (보행 시 부하의 위치에 따른 발의 안정성 및 운동학적 분석에 관한 연구)

  • Lee, Sang-Yeol;Bae, Sung-Soo
    • The Journal of Korean Physical Therapy
    • /
    • v.21 no.2
    • /
    • pp.97-101
    • /
    • 2009
  • Purpose: This study examined how the direction of carrying a load affects the foot stability and kinesiology while walking. Methods: The heel rotation, Hallux stiffness, foot balance, metatarsal load, toe out angle, subtalar joint flexibility were measured in 40 adults (men and women) who carried a load back and forth, walking on a 2-meter-long board. The measurement was carried out three times and the mean of the measurements was used to compare the difference between the front, back and the condition without a load. Results: While walking, heel rotation and hallux stiffness occurred most when a front load was applied compared to a back load or no load condition (p<0.05). A metatarsal load also appeared to be the highest with the frond load, but there was no significant difference in the balance of the whole foot. Both the toe out angle and subtalar joint flexibility appeared to increase significantly (p<0.05). Conclusion: Applying the front load causes subtalar joint instability and increases the plantar foot pressure imbalance during walking.

  • PDF

Effects of Abnormal Neck Posture on Postural Stability (목 자세에 따른 선 자세에서의 신체균형능력 평가)

  • Park, Sung Ha
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.41 no.2
    • /
    • pp.16-23
    • /
    • 2018
  • Postural instability can increase the likelihood of hazardous slip and fall accidents in workplaces. The present study intended to extend understanding of the effect of abnormal neck posture on postural control during quiet standing. The effect of body fatigue on the postural control was also of primary concern. Twelve healthy undergraduate students volunteered to participate in the experiment. Standing on a force platform with the neck neutral, flexed, extended, or rotated, subjects' center of pressures (COP) were measured under the two levels of body fatigue. For the fatigue condition, Subjects exercised in a treadmill to meet the predetermined level of body fatigue. Analyzing the position coordinates of COPs, the length of postural sway path was assessed in both medio-lateral (ML) axis and anterior-posterior (AP) axis. Results showed that, in AP direction, neck extension or rotation significantly increased the sway length as compared with neck neutral. Neck extension led to greater sway length compared to neck rotation. Neck flexion did not differ from neck neutral. The sway length in the AP direction also became significantly larger as the body fatigue accumulated after treadmill exercise. In ML direction, as compared to neutral posture, the neck extension, flexion, or rotation did not significantly affect the length of postural sway path. However, the sway length seemed to increase marginally with the neck extended during the fatigued condition. This study demonstrates that abnormal neck posture may interfere with postural control during standing. The ability to maintain postural stability decreases significantly with the neck extended or rotated. Body fatigue leads to postural instability further.

Intraocular Injection of Muscimol Induces Illusory Motion Reversal in Goldfish

  • Lee, Sang-Yoon;Jung, Chang-Sub
    • The Korean Journal of Physiology and Pharmacology
    • /
    • v.13 no.6
    • /
    • pp.469-473
    • /
    • 2009
  • Induced activation of the gamma-aminobutyric $acid_A$ ($GABA_A$) receptor in the retina of goldfish caused the fish to rotate in the opposite direction to that of the spinning pattern during an optomotor response (OMR) measurement. Muscimol, a $GABA_A$ receptor agonist, modified OMR in a concentration-dependent manner. The $GABA_B$ receptor agonist baclofen and $GABA_C$ receptor agonist CACA did not affect OMR. The observed modifications in OMR included decreased anterograde rotation $(0.01\sim0.03\;{\mu}M)$, coexistence of retrograde rotation and decreased anterograde rotation $(0.1\sim30\;{\mu}M)$ and only retrograde rotation $(100\;{\mu}M\sim1\;mM)$. In contrast, the $GABA_A$ receptor antagonist bicuculline blocked muscimol-induced retrograde rotation. Based on these results, we inferred that the coding inducing retrograde movement of the goldfish retina is essentially associated with the GABAA receptor-related visual pathway. Furthermore, from our novel approach using observations of goldfish behavior the induced discrete snapshot duration was approximately 573 ms when the fish were under the influence of muscimol.