• 제목/요약/키워드: Direction detector

검색결과 139건 처리시간 0.023초

혈관 윤곽의 자동적 식별을 위한 방향성 기반의 적응적 추적 알고리즘 (Adaptive Tracking Algorithm Based on Direction Field for Automated Identification of Vessel Contour)

  • 박석일;이종실;구자일;홍승홍
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1997년도 춘계학술대회
    • /
    • pp.414-417
    • /
    • 1997
  • This paper presents vessel contour for extracting features and segmentating narrow blood vessels down to a diameter of two pixels in digital subtraction angiographic image. We present a new tracking algorithm for contour, mainly blood vessels in DSA image, and extracting properties such as their intensities, diameters, and center lines by exploiting spatial continuity. The proposed algorithm comes to detect blood vessel's boundary using difference edge detector one of homogeneity operator and find a next centerline position by direction vector of edge information. This algorithm enhanced variation of vessel's diameter compared to Sun's tracking algorithm and lessoned to compute as direction vector decide adaptively entire vessel's direction field. The processed images are intended to support radiologists in diagnosis, radiation therapy planning, and surgical planning. The algorithm should be useful for automating angiographic analyses of blood vessels.

  • PDF

A Feature of Stellar Density Distribution within Tidal Radius of Globular Cluster NGC 6626 in the Bulge Direction

  • Chun, Sang-Hyun;Lim, Dong-Wook;Kim, Myo-Jin;Sohn, Young-Jong
    • 천문학회보
    • /
    • 제35권2호
    • /
    • pp.82.1-82.1
    • /
    • 2010
  • We have investigated the spatial configuration of stars within the tidal radius of metal poor globular cluster NGC 6626 in the bulge direction. Data were obtained in near-IR J,H,Ks bands with wide-field ($20'\times20'$) detector, WIRCam at CFHT. To trace the stellar density around target cluster, we sorted cluster's member stars by using a mask filtering algorithm and weighting the stars on the color-magnitude diagram. From the weighted surface density map, we found that the stellar spatial distributions within the tidal radius appear asymmetric and distorted features. Especially, we found that more prominent over-density features are extending toward the direction of Galactic plane rather than toward the directions of the Galactic center and its orbital motion. This orientation of the stellar density distribution can be interpreted with result of disk-shock effect of the Galaxy that the cluster had been experienced. Indeed, this over-density feature are well represented in the radial surface density profile for different angular sections. As one of the metal poor globular clusters with extended horizontal branch (EHB) in the bulge direction, NGC 6626 is kinematically decoupled from the normal clusters and known to have disk motion of peculiar motion. Thus, our result will be able to add further constraints to understand the origin of this cluster and the formation of bulge region in early universe.

  • PDF

영상해석을 통한 철도건널목 장애물 검지방법 개선 (Improvement of Obstruction Detecting Method at Railroad Crossing by Image Analyze)

  • 송현삼;김영달;이대동;심재명
    • 전기학회논문지
    • /
    • 제60권7호
    • /
    • pp.1444-1450
    • /
    • 2011
  • An analysis of the causes of railroad crossing accidents reveals that most train collision accidents that occur when safety crossing devices are functioning normally occur because vehicles either experience engine failure on the tracks or because drivers were not notified of the coming train, in which case they get trapped on the tracks when the crossing barriers descend. To prevent such an accident, obstacle detection device by using laser beams detecting the presence of obstacle and crossing bar direction controller by moving direction detection sensor using the Earth's magnetic field detection technology are used in the railroad crossing. Despite using the obstacles detector and crossing bar direction controller in the railroad crossing, the equipments for the railroad crossing does not prevent accidents completely. Therefore, this research has studied new method that can detect obstacles through image analyze and alternate existing equipments. There will be excellent effect to be preventing railroad crossing accident by developing a reliable and new obstacle detecting device.

전기철도 집전장치의 아크량에 따른 비디오 이미지 분석 (Video Image Analysis in Accordance with Power Density of Arcing for Current Collection System in Electric Railway)

  • 박영;이기원;박철민;김재광;전아람;권삼영;조용현
    • 전기학회논문지
    • /
    • 제62권9호
    • /
    • pp.1343-1347
    • /
    • 2013
  • This paper presents an analysis methods for current collection quality in catenary system by means of video image based monitoring system. Arcing is the sparking at the interface point between pantograph and contact wire when the electric trains have traction current values at speed. Percentage of arcing at maximum line speed is measurable parameters for compliance with the requirements on dynamic behaviour of the interface between pantograph and contact wire in accordance with requirement of IEC and EN standards. The arc detector and video is installed on a train aim at the trailing contact strip according to the travel direction. The arc detector presented and measured verity of value such as the duration and power density of each arc and the video image is measured a image when the arc is occurred in pantograph. In this paper we analysis of video image in accordance with power density of arcing from arc detector and compared with video image and power density of arcing so as to produce quality of arcing from image.

Analytic simulator and image generator of multiple-scattering Compton camera for prompt gamma ray imaging

  • Kim, Soo Mee
    • Biomedical Engineering Letters
    • /
    • 제8권4호
    • /
    • pp.383-392
    • /
    • 2018
  • For prompt gamma ray imaging for biomedical applications and environmental radiation monitoring, we propose herein a multiple-scattering Compton camera (MSCC). MSCC consists of three or more semiconductor layers with good energy resolution, and has potential for simultaneous detection and differentiation of multiple radio-isotopes based on the measured energies, as well as three-dimensional (3D) imaging of the radio-isotope distribution. In this study, we developed an analytic simulator and a 3D image generator for a MSCC, including the physical models of the radiation source emission and detection processes that can be utilized for geometry and performance prediction prior to the construction of a real system. The analytic simulator for a MSCC records coincidence detections of successive interactions in multiple detector layers. In the successive interaction processes, the emission direction of the incident gamma ray, the scattering angle, and the changed traveling path after the Compton scattering interaction in each detector, were determined by a conical surface uniform random number generator (RNG), and by a Klein-Nishina RNG. The 3D image generator has two functions: the recovery of the initial source energy spectrum and the 3D spatial distribution of the source. We evaluated the analytic simulator and image generator with two different energetic point radiation sources (Cs-137 and Co-60) and with an MSCC comprising three detector layers. The recovered initial energies of the incident radiations were well differentiated from the generated MSCC events. Correspondingly, we could obtain a multi-tracer image that combined the two differentiated images. The developed analytic simulator in this study emulated the randomness of the detection process of a multiple-scattering Compton camera, including the inherent degradation factors of the detectors, such as the limited spatial and energy resolutions. The Doppler-broadening effect owing to the momentum distribution of electrons in Compton scattering was not considered in the detection process because most interested isotopes for biomedical and environmental applications have high energies that are less sensitive to Doppler broadening. The analytic simulator and image generator for MSCC can be utilized to determine the optimal geometrical parameters, such as the distances between detectors and detector size, thus affecting the imaging performance of the Compton camera prior to the development of a real system.

Brief Introduction to Angle-Resolved Photoemission Spectroscopy

  • 김형도
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2012년도 제42회 동계 정기 학술대회 초록집
    • /
    • pp.82-82
    • /
    • 2012
  • Angle-resolved photoemission spectroscopy (ARPES) is a powerful tool to investigate the electronic structure of a single-crystalline solid. After the development of a two-dimensional electron detector, it became a basic experimental method in solid state physics comparable to other powerful tools such as x-ray and neutron scatterings. In this tutorial, I talk briefly on the basic principle of ARPES and its recent and future direction of development.

  • PDF

PSD 센서를 이용한 모션캡쳐센서의 정밀도 향상을 위한 보정에 관한 연구 (A Study on the Sensor Calibration of Motion Capture System using PSD Sensor to Improve the Accuracy)

  • 최훈일;조용준;유영기
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 학술대회 논문집 정보 및 제어부문
    • /
    • pp.583-585
    • /
    • 2004
  • In this paper we will deal with a calibration method for low cost motion capture system using psd(position sensitive detection) optical sensor. To measure the incident direction of the light from LED emitted marker, the PSD is used the output current ratio on the electrode of PSD is proportional with the incident position of the light focused by lens. In order to defect the direction of the light, the current output is converted into digital voltage value by opamp circuits peak detector and AD converter with the digital value the incident position is measured. Unfortunately, due to the non-linearly problem of the circuit poor position accuracy is shown. To overcome such problems, we compensated the non-linearly by using least-square fitting method. After compensated the non-linearly in the circuit, the system showed more enhanced position accuracy.

  • PDF

수광각을 자동정렬하는 무선광검출기 (Automatic Angle Alignment of a Wireless Optical Detector)

  • 이성호
    • 한국전자파학회논문지
    • /
    • 제14권5호
    • /
    • pp.466-471
    • /
    • 2003
  • 본 논문에서는 포토다이오드의 방향이 항상 신호광의 입사방향과 일치하도록 수광각을 자동정렬하는 광검출기의 구조를 새로이 소개한다. 이 광검출기에서는 신호광을 수신하기 위한 포토다이오드 1개를 중심으로 $\Phi$-축상에 4개의 포토다이오드와 $\theta$-축상에 2개의 포토다이오드를 추가로 배열하여 각각 $\Phi$-축과 $\theta$-축에 해당하는 모터를 구동한다. 이 광검출기는 임의의 모든 방향으로부터 입사하는 신호광에 대하여 약 1초 이내에 수신방향을 신호광 쪽으로 일치시킨다.

Auto-Correlation을 이용한 펄스 도플러 시스템에 관한 연구 (A study on the development of Pulsed Doppler System using Auto-Correlation)

  • 임춘성;강충신;이행세;김영길
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1988년도 전기.전자공학 학술대회 논문집
    • /
    • pp.705-708
    • /
    • 1988
  • Ultrasound Doppler Diagnostic System utilizes the Doppler effect for measurement of blood velocity. The sign of the Doppler frequency shift represents blood flow direction. Pulsed Doppler System uses Phase detector and zerocrossing method to produce simultaneous independent audio and velocity signals for forward and reverse blood flow direction in the time domain, had been fabricated. But time-domain analyzing such as audio evaluation and zerocrossing detection for instantaneous and mean frequency measurement doesn't, provide both an accurate and quantitative result. Therefore, it is necessary to adopt frequency domain technique to improve system performance. In this paper, we describe a unit which is composed of Pulsed Doppler System and real-time spectrum analyzer (installed TMS 32010 DSP Chip). This unit shows time-dependent spectrum variation and mean velocity of blood Signal.

  • PDF

Comparison of Alpha Particle Signals with respect to Incident Direction onto n-Si:H pin diodes

  • Kim, Ho-Kyung;Gyuseong Cho;Hur, Woo-Sung;Lee, Wanno;Hong, Wan-Shick
    • 한국원자력학회:학술대회논문집
    • /
    • 한국원자력학회 1996년도 춘계학술발표회논문집(4)
    • /
    • pp.133-138
    • /
    • 1996
  • For the application of hydrogenated amorphous silicon (a-Si:H) p-i-n structural diode as the alpha particle spectroscopy, the induced charge collection was simulated based on a relevant non-uniform charge generation model. The simulation was accomplished for two extreme cases of the incident direction of alpha particle, p-and n-side, respectively. As expected, for the complete charge collection, the hole collection should be severely considered due to its poor mobility and the full depletion bias required. For the comparison of signal corresponding to the detector configuration or structure, although n-i-p configuration shows a wider range of linearity to the energy, p-i-n configuration is more suitable in the viewpoint of linearity and signal value for the considering energy range.

  • PDF