• 제목/요약/키워드: Direct-shear test

검색결과 421건 처리시간 0.025초

Cyclic behavior of various sands and structural materials interfaces

  • Cabalar, Ali Firat
    • Geomechanics and Engineering
    • /
    • 제10권1호
    • /
    • pp.1-19
    • /
    • 2016
  • This paper presents the results of an intensive experimental investigation on cyclic behavior of various sands and structural materials interface. Comprehensive measurements of the horizontal displacement and shear stresses developed during testing were performed using an automated constant normal load (CNL) cyclic direct shear test apparatus. Two different particle sizes (0.5 mm-0.25 mm and, 2.0 mm-1.0 mm) of sands having distinct shapes (rounded and angular) were tested in a cyclic direct shear testing apparatus at two vertical stress levels (${\sigma}=50kPa$, and 100 kPa) and two rates of displacement ($R_D=2.0mm/min$, and 0.025 mm/min) against various structural materials (i.e., steel, concrete, and wood). The cyclic direct shear tests performed during this investigation indicate that (i) the shear stresses developed during shearing highly depend on both the shape and size of sand grains; (ii) characteristics of the structural materials are closely related to interface response; and (iii) the rate of displacement is slightly effective on the results.

대형 직접전단시험과 대형 삼축압축시험에 의한 조립재료의 전단강도 비교 (Comparison of Shear Strength of Coarse Materials Measured in Large Direct Shear and Large Triaxial Shear Tests)

  • 서민우;김범주;하익수
    • 한국지반환경공학회 논문집
    • /
    • 제10권1호
    • /
    • pp.25-34
    • /
    • 2009
  • 댐이나 항만 건설시 재료로 사용되는 조립재는 입자크기가 일반 토사에 비해 매우 크기 때문에 이러한 재료에 대해서 전단시험을 수행할 때에는 가급적 대형 전단시험장치를 사용하는 것이 보다 정확한 결과를 얻기 위해 바람직하다. 대형 전단시험장치로는 일반적으로 대형 직접전단시험장치와 대형 삼축압축시험장치가 있으나 일반 토질시험장치와 비교해 제작과 보급, 운영 등의 어려움 때문에 현재까지 국내에서 두 시험장치를 사용하여 시험을 수행한 실적은 많지 않은 편이다. 본 연구에서는 댐 축조재로 사용되는 입경이 큰 조립재료를 대상으로 시료의 평균 입자크기와 공시체 크기, 연직응력(구속압) 조건 등에 차이가 있는 총 6개 case에 대해서 대형 직접전단시험과 대형 삼축압축시험을 수행하고 두 시험간 전단강도 특성의 차이를 비교하였다. Mohr-Coulomb 강도규준에 의한 전단강도를 기준으로, 대형 직접전단시험을 통해 산정된 전단강도가 대형 삼축압축시험을 통해 산정된 전단강도보다 전체적으로 크게 나타났으며 또한, 1,000kPa 수직응력에 대해 두 시험간 산정된 전단강도를 비교한 결과 대형 직접전단시험에 의한 전단강도가 대형 삼축압축시험에 의한 전단강도보다 약 10~70% 크게 나타나 입경이 작은 일반 토사와 비교해 그 차이가 크고, 대형 직접전단시험결과의 분산도가 상대적으로 높은 것으로 나타났다.

  • PDF

다양한 시험법에 의해 산정된 토목섬유 사이의 접촉면 전단강도 비교 (Comparisons on the Interface Shear Strength of Geosynthetics Evaluated by Using Various Kinds of Testing Methods)

  • 서민우;오명학;윤현석;박준법
    • 대한토목학회논문집
    • /
    • 제26권2C호
    • /
    • pp.73-80
    • /
    • 2006
  • 4종류 토목섬유 조합으로 구성된 4가지 토목섬유 접촉면의 정적 및 동적 하중 상태에서의 전단거동을 평가하였다. 정적하중 조건에서 경사판 시험과 직접전단 시험을 수행하였으며, 두가지 시험 결과를 상호 비교하였다. 비교 결과 직접전단 시험의 경우, 직접전단 시험이 수행되지 아니한 낮은 응력 단계에서의 접촉면 전단강도를 실제보다 크게 예측할 가능성이 높은 것으로 나타났다. 또한 정적상태에서 수행된 두 종류 시험을 통해 산정된 전단강도를 이용하여 곡선형태의 파괴 포락선식을 구할 수 있었다. 한편 정적 전단강도와 진동대시험을 통해 동적 하중 상태에서 구한 접촉면 전단강도를 비교하여, 하중 특성과 가해진 응력 크기에 따라 각기 다른 마찰 특성을 보임을 확인하였다. 따라서 토목섬유 사이의 접촉면 전단강도를 정확히 평가하기 위해서는 실제 현장에 설치되는 재료를 대상으로 예상되는 응력의 크기와 하중 유형을 고려하여 시험이 수행되어야 할 것이다.

전단파, 전자기파 및 콘 관입저항력을 이용한 직접전단실험시 전단영역 특성 평가 (Evaluation of Shear Zone in Direct Shear Test Using Elastic, Electromagnetic Waves and Cone Tip Resistance)

  • 변용훈;쭝꽝훙;짠밍콰;이종섭
    • 한국지반공학회논문집
    • /
    • 제27권2호
    • /
    • pp.43-52
    • /
    • 2011
  • 조립토로 구성된 지반구조물의 안정성은 전단변형에 따른 전단영역의 특성변화에 의해 영향을받는다. 본 연구의 목적은 전단파와 전기비저항 및 콘 선단저항력을 이용하여 직접전단실험시 발생하는 전단영역의 특성을 파악하는 것이다. 전단영역의 특성을 파악하기 위하여, 아크릴 재질로 직접전단상자를 제작하였으며, 직접전단상자의 벽면에는 전단파와 전기비저항의 측정을 위하여 벤더엘리먼트와 전기비저항 프로브를 설치하였다. 벤더엘리먼트와 전기비저항 프로브는 전단영역과 비전단영역에 각각 설치되어, 전단변형에 따른 조립토의 거동을 비교할 수 있도록 하였다. 또한, 콘 선단저항력을 측정할 수 있도록 개발한 마이크로 콘을 첨두강도상태와 잔류강도상태에서 관입하여 깊이에 따른 시료의 강도분포를 관찰하였다. 실험결과, 바닥부근과 하부전단영역에서는 전단변형에 따른 전단파 속도는 일정하였지만, 상부전단영역에서의 전단파 속도는 증가하였다. 또한, 바닥부근의 전기비저항은 변화가 없는 반면, 하부전단영역에서 전기비저항은 상대밀도에 따라 수직변형률과 반비례관계로 나타났다. 콘 선단저항력의 변화도 전단파 속도의 변화와 유사하게 상부전단영역에서 큰 변화가 관찰되었다. 본 논문에서 제시한 직접전단실험시 전단파와 전기비저항을 관찰하는 것과 실험완료 후 콘 관입실험은 조립토의 전단영역 특성을 파악하기 위한 매우 효과적인 방법이 될 수 있음을 보여준다.

콘크리트 표면처리와 가열조건에 따른 섬유쉬트와 콘크리트의 부착강도에 관한 연구 (A Study on Bond Strength between Fiber Sheet and Concrete for Concrete Surface Preparation and Heating Condition)

  • 안상호
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제6권4호
    • /
    • pp.201-207
    • /
    • 2002
  • An advanced fiber sheet has been widely used for strengthening of the concrete structures due to its excellent properties such as high strength and light weight. Bond strength is very important in strengthening the concrete structures using an advanced fiber sheet. This research examines the bond behavior between fiber sheet and concrete, investigates the bond strength by the direct pull-out test and the tensile-shear test. To obtain the tensile-shear strength a double-face shear type bond test is conducted. The primary test variables are the types of concrete surface roughness (disk-grinding/chipping) and retrofitting methods (bonding/injection). Thirty specimens were tested to evaluate the bond strength. It is shown that the average bond strength between fiber sheet and concrete by the direct pull-out test and the tensile-shear test is $22.3{\sim}23.1kgf/cm^2$ $17.92{\sim}19.75kgf/cm^2$, respectively.

대형전단시험에 의한 국내 도시폐기물의 전단특성 분석 (Analysis of Shear Strength of Domestic Municipal Wastes by Large Shear Test)

  • 정하익;이용수;정길수;홍승서
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 1999년도 봄 학술발표회 논문집
    • /
    • pp.529-532
    • /
    • 1999
  • This paper presented the characteristics of shear strength of domestic municipal wastes including S landfill wastes. A series of large direct shear tests were peformed with waste specimens sampled from S landfill located in middle area of domestic land. Investigated items were cohesion and internal friction angle of shear strength parameter. The test result was compared with existing test data. The research results showed that cohesion 0.1296∼0.1340kg/$\textrm{cm}^2$ and angle of friction 22.1$^{\circ}$∼25.3$^{\circ}$for S landfill wastes, cohesion 0∼0.381kg/$\textrm{cm}^2$ and friction angle 22.1$^{\circ}$∼41.3$^{\circ}$ for domestic landfill wastes.

  • PDF

직접전단시험에 의한 폐타이어 혼합경량토의 전단특성 연구 (Shearing Properties of Waste Tire Powder-Added Lightweight Soil by Direct Shear Test)

  • 김윤태;강효섭
    • 한국해양공학회지
    • /
    • 제23권3호
    • /
    • pp.20-29
    • /
    • 2009
  • This study investigated the shear strength characteristics of waste tire powder-added lightweight soil (WTLS), which were developed to recycle dredged soil, bottom ash, and waste tires. The WTLS used in this experiment consisted of dredged soil, bottom ash, waste tire powder, and cement. Test specimens were prepared with various contents of waste tire powder ranging from 0% to 100% at 25% intervals and bottom ash contents of 0% or 100% by the weight of the dry dredged soil. In this study several series of direct shear tests were carried out, which indicated that the shear properties of WTLS were strongly influenced by the mixing conditions, such as the waste tire powder content and bottom ash content. The unit weight, as well as the shear strength of the WTLS, decreased with an increase in waste tire powder content. The shear strength of WTLS with bottom ash was 1.34 times greater than that of WTLS without bottom ash. An average increase in cohesion of 30 kPa was obtained in WTLS with the inclusion of bottom ash due to the bond strength induced from the pozzolanic reaction of the bottom ash. In this test, the maximum value of the internal friction angle was obtained with a 25% content of waste tire powder.

직접전단실험을 이용한 세립토의 전단강도 및 유변학적 정수 산정 (Estimation of Shear Strength and Rheological Parameters of Fine-Grained Soil Using Direct Shear Test)

  • 박근우;홍원택;이종섭
    • 한국지반환경공학회 논문집
    • /
    • 제18권2호
    • /
    • pp.29-37
    • /
    • 2017
  • 집중호우로 인하여 산악지반에 발생하는 토석류의 거동은 대상지반 세립분의 전단강도 및 유변학적 특성들에 의하여 영향을 받기 때문에, 두 특성에 대한 정수는 토석류 거동을 파악하는데 매우 중요한 요소이다. 본 연구에서는 직접전단 실험을 통하여 세립분의 전단강도 및 유변학적 정수를 평가하고자 하였다. 건조상태와 액성한계상태로 조성된 두 가지 세립분 시료에 대하여 직접 전단실험을 수행하였으며, 연직응력에 따른 전단강도를 측정하여 점착력과 내부마찰각을 산정하였다. 또한 액성한계로 조성된 시료의 잔류전단강도를 획득하기 위하여 전단변형률속도와 전단방향을 변화시켜 반복전단실험을 수행하였다. 실험 결과, 액성한계상태의 시료는 건조 상태 시료에 비해 내부마찰각은 작지만 점착력은 더 큰 것으로 나타났으며, 잔류전단강도를 통해 산정한 내부마찰각과 점착력은 첨두전단강도에 의해 산정된 결과보다 작은 것으로 나타났다. 반복전단 결과, 전단변형률속도와 잔류전단강도는 선형적인 관계를 보였으며, 전단변형률속도-잔류전단강도 관계의 기울기로써 결정되는 점성은 약 $73.60Pa{\cdot}s$로 산정되었다. 본 연구는 직접전단 장비가 산악지반 토석류 거동과 관련된 세립분의 전단강도 및 유변학적 정수 산정에 효과적으로 활용될 수 있음을 보여준다.

3DEC을 이용한 일정수직하중 조건에서의 전단강도에 관한 연구 (A Study on Shear Strength under Constant Normal Load Conditions by Using 3DEC)

  • 노영목;문홍주;김기호;장원일
    • 터널과지하공간
    • /
    • 제24권1호
    • /
    • pp.46-54
    • /
    • 2014
  • 암반 구조물의 안정성에 결정적인 영향을 미치는 절리의 특성을 파악하기 위해서는 일반적으로 직접전단시험을 통한 연구가 수행되고 있으나, 본 연구에서는 3차원 개별요소법에 근거한 3DEC을 사용하여 직접전단시험을 수치해석적으로 수행하였다. 톱니각과 강도가 상이한 인공 절리시험편에 대해 수직하중을 4단계로 변화시켜가며 일정수직하중 조건에서 실험실 직접전단시험으로 최대전단강도를 측정하였다. 그리고 실내시험을 통해 얻은 시험편의 역학적 물성으로 수치해석 모델링을 수행하였고, 획득한 전단강도를 실험실 직접전단시험으로 수행한 전단강도와 비교 분석하였다. 그 결과 개별요소법에 의한 수치해석은 암반의 전단거동을 잘 모사할 수 있을 것으로 사료된다.