• 제목/요약/키워드: Direct resin bonding

검색결과 42건 처리시간 0.023초

TETRACYCLINE에 의한 변색치의 심미적 치료

  • 황병각;이철원;김석균
    • 대한심미치과학회지
    • /
    • 제1권1호
    • /
    • pp.50-57
    • /
    • 1992
  • Intrinsic discoloration of permanent anterior teeth is a continuing esthetic problem. Tetracycline ingested during amelogenesis has long been recognized as predisposing factor in intrinsic staining. Methods for restoring original tooth color have included (1) complete PFM crown coverage (2) porcelain laminate veneers (3) direct bonding of composite resin, and (4) bleaching. In the case of tetracycline-stained upper anterior teeth, We authors, obtained the satisfactory results by means of gingivectomy, preliminary bleaching and porcelain laminate veneer restoration.

  • PDF

직접 부착법과 간접 부착법이 열순환 후 부착강도와 미세누출에 미치는 영향에 대한 연구 (Effects of direct and indirect bonding techniques on bond strength and microleakage after thermocycling)

  • Ozturk, Firat;Babacan, Hasan;Nalcaci, Ruhi;Kustarci, Alper
    • 대한치과교정학회지
    • /
    • 제39권6호
    • /
    • pp.393-401
    • /
    • 2009
  • 본 연구는 직접 또는 간접 부착법으로 부착한 교정용 브라켓을 열순환 처리 후에 전단 결합 강도(shear bond strength, SBS)와 치아-접착제-브라켓 복합체의 미세 누출을 비교하기 위하여 시행하였다. 50개의 치아우식증이 없는 사람 소구치를 구하여 동등한 2개의 군으로 나누었다. 직접 부착군에서는 광중합 접착제 및 primer (Transbond XT)를 사용하였고 간접 부착군에서는 광중합 접착제와(Transbond XT) 화학중합 primer (Sondhi Rapid Set)를 사용하였다. 중합 후에 치아는 24시간 동안 증류수에 보관하였고 이후 500회 열순환 처리를 하였다. 미세누출의 평가를 위해 각 군에서 10개의 치아에 nail varnish로 추가 봉연을 실시하고 0.5% basic fuchsin에 24시간 동안 염색한 후 입체현미경으로 검경하였다. 만능시험기를 이용하여 각 군의 치아 15개로 SBS를 계측하였고 adhesive remnant index (ARI)를 평가하였다. 결과 자료는 Mann-Whitney U test, Chi-square test, Fisher's exact test로 통계 분석하였다. 직접 부착군과 간접 부착군 사이에 SBS 및 미세누출의 통계적으로 유의한 차이는 보이지 않았으며 간접 부착군에서 통계적으로 유의하게 ARI 점수가 낮았다. 브라켓의 탈락은 법랑질-레진 계면에서 발생하였다. 이상의 결과로 보아 부착법의 차이는 미세누출의 양과 SBS에 유의한 영향을 미치지 않는다.

Crystal growth에 의한 법랑질 표면처리가 교정용 브라켓 접착제의 전단결합강도에 미치는 영향 (THE EFFECTS OF CRYSTAL GROWTH ON SHEAR BOND STRENGTH OF ORTHODONTIC BRACKET ADHESIVES TO ENAMEL SURFACE)

  • 이영준;박영국
    • 대한치과교정학회지
    • /
    • 제27권5호
    • /
    • pp.839-852
    • /
    • 1997
  • Crystal growth 용액인 황화이온을 함유한 폴리아크릴산 용액에 의한 법랑질 표면처리는 법랑질 표면에 crystal growth를 유도함으로써 통상적인 산부식법을 대체하여 교정용 브라켓을 접착하기 위한 법랑질 전처치의 방법으로 사용될 수 있음이 제안된 바 있다. 이 연구는 crystal growth후 교정용 브라켓 접착제로 브라켓을 접착하는 방법의 임상적용 가능성을 구명하기 위하여 시행되었다. 발거된 사람소구치의 법랑질 표면을 $25\%$ 폴리아크릴산과 0.3M 황산을 함유한 기본 crystal growth 용액, 각각 0.3M lithium sulfate, 0.3M magnesium sulfate, 0.3M potassium sulfate를 첨가한 crystal growth 용액, $37\%$ 인산용액, 퍼미스로 각각 처리한 후, 교정용 광중합형 글래스아이오노머 시멘트와 교정용 레진접착제로 금속브라켓을 접착하였다. $37^{\circ}C$의 증류수에 24시간 침지시킨 후, 브라켓 전단결합강도를 측정하고 접착 파절양태를 관찰하였으며 표면처리된 법랑질 표면과 브라켓 제거후의 법랑질 표면을 주사전자현미경으로 관찰하여 다음과 같은 결과를 얻었다. Crystal growth후 광중합형 글래스아이오노머 시멘트로 브라켓 접착시 0.3M magnesium sulfate를 함유한 군의 브라켓 전단결합강도가 가장 높았다(p<0.01). Crystal growth후 광중합형 글래스아이오노머 시멘트로 접착한 군의 브라켓 전단결합강도는 crystal growth 후 레진접착제로 접착한 군보다 높았다(p<0.001). Magnesium sulfate, 또는 potassium sulfate를 함유한 crystal growth 용액으로 법랑질 표면을 처리한 후 글래스아이오노머시멘트로 접착한 군의 브라켓 전단결합강도는 산부식 후 레진 접착제로 접착한 군과 유의한 차이를 보이지 않았다. 브라켓 제거시 잔류접착제의 양은 글래스아이오노머 시멘트로 접착한 것이 가장 적었다. 이상의 결과는 magnesium sulfate나 potassium sulfate를 함유한 crystal growth 용액으로 법랑질 표면처리 후 교정용 광중합형 글래스 아이오노머 시멘트로 브라켓을 접착하는 방법이 통상적으로 사용되는 산부식 후 교정용 레진접착제에 의한 브라켓 접착법을 대체할 수 있음을 시사한다.

  • PDF

영구자석을 이용한 고양이 구치부 intrusion에 관한 초기 조직학적 연구 (AN INITIAL HISTOLOGIC STUDY ON MOLAR INTRUSION OF CAT WITH THE USAGE OF PERMANENT MAGNET)

  • 김승철;유영규
    • 대한치과교정학회지
    • /
    • 제20권1호
    • /
    • pp.169-179
    • /
    • 1990
  • Utilizing the repelling force of permanent magnet of find out weather it shows the findings of molar intrusion histologically and compares the result with the resin bite plane. As for the experimental animals, 10 cats of completion of permanent dentition with mean weight of 2.2kg which have flat occlusal plane of molar areas were used. I raised the cats under the condition of their being attached with manufactured appliance by direct bonding system and of their wearing vertical chin strap anesthetized for 12-14 hours per day through 5 days. Then, observing the root apex areas with lightmicroscope. The results were as follows; 1. In the group with resin bite plane, osteoblasts and osteoclasts could not find out but could find out periodontal ligment fiber obliquely angulated in the apical and lingual direction. 2. In the group with the permanent magnet, not only the obliquely angulated periodontal ligament fiber but also the osteoclasts at the apical areas were observed.

  • PDF

즉시 상아질 봉쇄와 지연 상아질 봉쇄에 따른 상아질 접착의 미세인장 결합강도 비교 (The comparison of microtensile bond strength with immediate and delayed dentin sealing)

  • 이흥배;한종현;심준성;김선재
    • 대한치과보철학회지
    • /
    • 제46권4호
    • /
    • pp.372-380
    • /
    • 2008
  • 연구목적: 본 연구의 목적은 즉시 상아질 봉쇄 (immediate dentin sealing; IDS)을 시행한 경우와 지연 상아질 봉쇄 (delayed dentin sealing ; DDS)를 시행한 경우를 비교하고, 지연 상아질 봉쇄 시 상아질 접착제를 먼저 중합한 경우와 복합레진과 함께 중합한 경우에 있어서 상아질과 복합레진의 결합강도를 비교하는 것이다. 재료 및 방법: 사람의 건전한 대구치 20개의 치관부를 삭제하여 상아질 표면을 노출시켰다. 상아질 접착 후 바로 복합레진을 축조하는 과정에서 군을 4 가지로 나누었다. 대조군은 주수 하에 model trimmer를 이용하여 치관부 삭제 후 바로 2-step etch-and-rinse dentin bonding agent (ONE-STEP, Bisco, USA)를 이용하여 상아질 접착을 시행하고 복합레진 (RENEW, Bisco, USA)을 수복하였다. 실험군 A는 치아 삭제 후, Fermit을 이용한 임시수복 상태로 5일간 생리식염수에 보관하였다. 임시수복 제거 후 상아질 접착제를 도포하고 별도의 중합없이 레진을 축조하고 함께 중합하였다. 실험군 B는 치아 삭제 후, 상아질 접착제 도포 및 중합하고 임시수복을 시행하여 5일간 생리식염수에 보관하였다. 임시수복 제거 후 상아질 접착제를 도포하고 별도의 중합없이 레진을 축조하고 함께 중합하였다. 실험군 C는 치아 삭제 후, 임시수복 상태로 5일간 생리식염수에 보관하였다. 임시수복 제거 후, 상아질 접착제를 도포 및 중합하고, 레진을 축조 및 중합하였다. 각 치아를 단면적 1 $mm^2$, 길이 10-12 mm의 막대형 시편으로 절단하여, 미세인장 결합강도를 측정하였다. 측정된 결합강도는 one-way ANOVA를 이용하여 비교 분석하였으며, 사후 검증은 Scheffe test를 이용하여 분석하였다. 연구결과: 본 실험의 결과는 다음과 같다. 1. 치아 삭제 후 별도의 상아질 접착 시행 없이 임시수복하고, 레진 축조 전 상아질 접착을 도포 후 별도의 중합과정 없이 레진과 함께 중합할 경우, 상아질과의 미세인장 결합강도는 유의하게 낮은 값을 보였다 (P < .01). 2. 치아 삭제 및 임시 수복 기간 후, 상아질 접착제를 먼저 중합하고 복합 레진을 수복하는 경우와 치아 삭제 후 상아질 접착을 시행하고 수복물 장착 시 상아질 접착을 재시행하는 경우 간의 상아질에 대한 결합강도의 차이는 없었다 (P > .05).

임상가를 위한 특집 3 - Minimally Invasive Approach with Composite Resin

  • 장희선
    • 대한치과의사협회지
    • /
    • 제51권11호
    • /
    • pp.604-609
    • /
    • 2013
  • Crown fractures are relatively common trauma to anterior teeth, and should be restored immediately in most cases. For those who suffer from unfortunate traumatic episode, the best treatment option should be minimally invasive approach. In the presence of fractured tooth fragment, reattachment procedure creates positive emotional response in the patient and simplifies the procedure and maintenance of the patient's original tooth anatomy and occlusion. Without fractured tooth fragment, next conservative option could be direct composite restoration which is based on minimal invasion concept. This article proposes simple and very conservative techniques that anyone can do in daily practice.

Plasma arc light를 이용한 bracket 부착시의 전단결합강도와 파절양상의 유형 (Shear bond strength and adhesive failure pattern in bracket bonding with plasma arc light)

  • 유형석;오영근;이승연;박영철
    • 대한치과교정학회지
    • /
    • 제31권2호통권85호
    • /
    • pp.261-270
    • /
    • 2001
  • 본 연구의 목적은 bracket 부착시 광조사시간을 획기적으로 감소시킬 수 있는 plasma arc light의 임상적 유용성을 visible light 중합시의 전단결합강도와 접착파절양상과 비교해 봄으로써 평가해 보는데 있다. 사람의 상하악 소구치를 포매하여 만든 레진블럭시편에 광중합 접착제인 Transbond$^{\circledR}$를 사용하여 수종의 bracket을 각각의 조건에 따라 부착한 후 만능 물성시험기를 이용하여 전단결합강도를 측정하고, 접착파절양상을 stereoscope을 이용하여 관찰하여 다음과 같은 결과를 얻었다. 1. Plasma arc light를 이용한 수종의 bracket 접착시 metal bracket과 ceramic bracket의 전단결합강도는 임상적으로 사용하기에 충분한 값을 나타내었으며, resin bracket 경우 다른 bracket 비해 전단결합강도가 현저히 작은 값을 나타내었지만 임상적으로 사용이 가능한 값을 나타내었다. 2. Visible light를 이용한 metal bracket의 광중합시 광조사시간에 따른 전단결합강도는 광조사 시간에 따른 유의한 차이를 보이지 않았으며, 임상적으로 사용하기에 충분한 강도를 나타내었다. 3. Plasma arc light를 이용한 수종의 bracket 접착시 접착제 잔류지수를 통해 접착파절양상을 관찰한 결과, metal bracket과 resin bracket 경우 bracket기저면에 접착제가 반 이상 남아 있지 않은 경우가 많았으며, ceramic bracket의 경우 bracket기저면에 접착제가 반 이상 남아 있는 경우가 많았다. 4. Metal bracket의 부착시 plasma arc light를 2초간 광조사한 군과 visible light를 10초간 광조사한 군의 전단결합강도와 접착파절양상을 비교시 유의한 차이를 보이지 않았다. 6. Plasma arc light를 이용한 광중합시 광조사 거리에 따른 전단결합강도는 거리가 증가할수록 감소하였다. 이상의 실험 결과는 plasma arc light를 이용한 bracket의 접착시 전단결합강도 저하의 우려 없이 임상적으로 사용 가능함을 시사한다.

  • PDF

간접 레진수복시 상아질 접착제의 중합 여부에 따른 결합 효능 (Bonding efficacy of cured or uncured dentin adhesives in indirect resin)

  • 장지현;이빈나;장훈상;황윤찬;오원만;황인남
    • Restorative Dentistry and Endodontics
    • /
    • 제36권6호
    • /
    • pp.490-497
    • /
    • 2011
  • 연구목적: 본 연구는 간접 레진수복시 상아질 접착제의 중합 여부가 레진인레이와 상아질간의 미세인장결합강도와 결합계면의 형태에 미치는 영향을 공초점 현미경 관찰을 통하여 평가하고자 하였다. 연구 재료 및 방법: 24개의 발거된 대구치를 절단하여 교합면 상아질을 노출시켰다. 수복 방법에 따라 크게 간접 레진수복과 직접 레진수복의 두 군으로 나누었다. 간접 레진수복군은 임시 수복하여 1주일 후, 상아질 접착 과정에 따라 4군(OB-C와 OB-NC군, OS-C와 OS-NC군)으로 나누었다. 간접 레진수복군은 산부식 처리된 상아질면에 OptiBond FL (Kerr) 또는 One-Step (Bisco) 상아질 접착제를 중합 여부에 따라 나누어 적용하였다. 처리된 상아질면에 제작된 3 mm 높이의 레진 인레이(Tescera, Bisco)를 Variolink II (Ivoclar Vivadent)를 사용하여 제조사의 지시에 따라 합착하였다. 직접 레진수복군은 산부식 처리된 상아질면에 상아질 접착 후, 복합레진 (Estelite${\Sigma}$, Tokuyama)으로 즉시 수복하였다(OB-D군, OS-D군). 수복을 마친 모든 치아는 24시간 후, 미세인장 결합 강도 평가와 공초점 레이저 주사 현미경 관찰(CLSM)을 시행하였다. 결과: 간접 레진수복군은 직접 레진수복군에 비하여 낮은 미세인장결합강도를 나타내었으며, 상아질 접착제를 광중합한 군(OB-C군, OS-C군)이 광중합을 시행하지 않은 군(OB-NC군, OS-NC군)에 비하여 높은 미세인장결합강도를 나타내었다. 접착 계면에 대한 CLSM 관찰에서 상아질 접착제를 광중합한 군에서 더 분명하고 균일한 혼성층이 관찰되었다. 상아질 접착제를 광중합하지 않은 군에서는 혼성층이 불분명하거나 거의 관찰되지 않았다. 결론: 간접 레진수복물의 합착시 레진시멘트의 적용 전에 상아질 접착제의 광중합은 분명하고 균일한 혼성층의 형성하며, 이는 결합강도의 향상에 기여한다.

브라켓 접착시 광중합방식에 따른 전단결합강도와 파절양상 비교 (The shear bond strength and adhesive failure pattern in bracket bonding with different light-curing methods)

  • 신재호;임용규;이동렬
    • 대한치과교정학회지
    • /
    • 제34권4호
    • /
    • pp.333-342
    • /
    • 2004
  • 기존의 가시광선 중합기와 비교해서 plasma are light와 LED) 방식의 중합기를 이용해 브라켓을 치아표면에 접착한 후 탈락시키는 실험을 시행해 각각의 중합방식별로 전단결합강도와 접착파절양상을 비교함으로써 임상에서의 유용성을 평가하고자 하였다. 교정치료를 위해 발거한 상, 하악 소구치 60개를 윈통형의 레진블록에 매몰하여 시편을 제작하였다. 광중합형 접착레진인 Transbond XT를 이용하여 광중합 방식별로 조건(가시광선 중합기는 40초, LED방식의 중합기는 20춘, 그리고 plasma arc light 방식의 중합기는 3초)에 따라 브라켓을 접착한 후 만능물성실험기로 전단결합강도를 측정하고 브라켓 기저면을 광학현미경으로 관찰해 접착파절양상을 관찰하여 다음과 같은 결과를 얻었다. 1. 가시광선 중합방식과 LED 중합방식으로 중합시킨 군간에 전단결합강도의 유의성 있는 차이는 없지만 plasma arc Light방식으로 중합시킨 군은 앞의 두 군에 비해 유의성이 있게 작은 간을 나타내었다(p>0.05). 2. 가시광선 중합방식으로 중합한 군과 LED방식을 이용한 군에서는 파절양상이 거의 유사하게 나타났다. 두 군 모두 잔류접착제가 치아면에만 있는 경우가 제일 적은 비율을 도였으며 브라켓 기저면에 50% 이상의 집착제가 남아 있는 양상이 더 큰 비율을 보였다. 3. Plasma arc light 로 중합시킨 경우에는 접착제가 브라켓 기저면에 50% 이하로 남아있는 양상이 큰 비율로 나타났으며 잔류 접착제 전체가 치아면에 남아 있는 경우는 15%였다. 이상의 실험결과 plasma arc light를 이용한 중합 방식이 가시광선이나 LED 방식을 이용한 중합 방식에 비해 유의성 있게(p>0.05) 낮은 전단결합강도를 보였으나 세 방식 모두 인상적으로 사용하기에 충분한 전단결합강도를 보여 유용하게 사용할 수 있음을 알 수 있었다.

금속의치상과 의치이장재료 간의 결합력에 관한 연구 (A study on the shear bond strength between Co-Cr denture base and relining materials)

  • 이나영;김두용;이영수;박원희
    • 대한치과보철학회지
    • /
    • 제49권1호
    • /
    • pp.8-15
    • /
    • 2011
  • 연구 목적: 본 연구의 목적은 금속 의치상 재료에 직접법으로 이장을 시행했을 때 표면처리와 시간에 따른 결합강도의 변화를 비교하는 것이다. 연구 재료 및 방법: Co-Cr 시편을 최대직경 9 mm의 육각기둥 형태로 절삭하여 제작하였으며, $110\;{\mu}m$$Al_2O_3$로 1분간 sandblasting 하였다. 시편을 18개씩 3군으로 나누어 A군은 화학적 처리 없이, B, C군은 금속표면처리제 (MR $bond^{(R)}$, Alloy $primer^{(R)}$)를 도포한 후 7 mm직경의 자가 중합형 이장용 레진 (Vertex $SC^{(R)}$) 기둥을 부착하였다. 각각의 그룹을 다시3군으로 나누어 수분 하에서 다른 기간 (0주, 1주, 2주)동안 저장한 다음 만능역학 실험기계 (Instron)를 이용하여 시편을 분리하였고, 분리되는 시점의 전단결합강도를 측정하였다. 통계처리는 two-way ANOVA와 Tukey 방법을 이용하여 5% 유의수준에서 분석하였다. 결과: 시편을 sandblasting한 실험에서는, 1분 동안 sandblasting 한 시편의 표면 거칠기가 가장 크게 나타났다. 전단결합강도 실험에서 결합강도는 B, C, A군의 순서로 낮아졌으며, 이 세 군 사이에 유의성 있는 차이를 보였다. 기간별로 봤을 때 결합강도는 수분에 저장하지 않은 군에서 가장 높았으며 2주 동안 수분에 저장한 군에서 가장 낮았으나 기간별로 유의성 있는 차이는 보이지 않았다. 기간과 군을 함께 고려했을 때 모든 군에서 침수 시간이 길어짐에 따라 결합강도가 낮아졌으나B군과C군에서 임상적인 유의성은 보이지 않았고, A군에서만 유의성 있게 결합강도가 낮아졌다. 결론:Co-Cr 금속 의치상에 진료실에서 직접법으로 이장을 할 경우 적절한 기계적 처리 (Sandblasting) 후 금속 표면 처리제를 도포하는 것이 유리할 것으로 사료된다.