• 제목/요약/키워드: Direct leakage current

검색결과 86건 처리시간 0.025초

직류와 60 Hz 교류가 중첩된 전압에 대한 산화아연 피뢰기 소자의 누설전류 특성 (Characteristics of ZnO Arrester Blocks Leakage Currents under Mixed Direct and 60 Hz Alternating Voltages)

  • 이복희;강성만;박건영
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제54권1호
    • /
    • pp.23-29
    • /
    • 2005
  • This paper presents the characteristics of leakage currents flowing through ZinC Oxide(ZnO) surge arrester blocks under mixed direct and 60 Hz alternating voltages. A mixed voltage, in which an alternating voltage is superimposed upon a direct voltage, appears on the HVDC system network. The mixed direct and alternating voltage generator with a peak open-circuit of 10 kV was designed and fabricated. The leakage currents and V-I curves for the fine and used ZnO surge arrester blocks were measured as a function of the voltage ratio k, where the voltage ratio k is defined as the ratio of the peak of alternating voltage to the peak of the mixed voltages. The resistive component in the leakage current in the low conduction region is significantly increased with increasing the voltage ratio k. The V-I characteristic curves for the mixed voltages lies between the direct and alternating characteristics, and the cross-over phenomenon in the high conduction region was appeared.

열화 진단 평가를 위한 직류 누설법의 활용 (APPLICATION OF DIRECT LEAKAGE CURRENT METHOD FOR AGING DIAGNOSIS EVALUATION)

  • 이관우;박대희
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2001년도 추계학술대회 논문집 Vol.14 No.1
    • /
    • pp.149-152
    • /
    • 2001
  • In this paper, aging diagnosis method of CV cable was investigated. CV cable was designed for the sake of using during 30 years. Therefore it was important to evaluate the cable's remaining life because CV cable used for power transmission line since 1970's. CV cable was mainly installed at the underground owing to the environmental condition. If the cable accident occurred, it needs the much time for the accident recovery and the much damage at the industrial activity. therefore, this paper should study the direct leakage current method, a sort of the cables' aging test method

  • PDF

열화 진단 평가를 위한 직류 누설법의 활용 (APPLICATION OF DIRECT LEAKAGE CURRENT METHOD FOR AGING DIAGNOSIS EVALUAT10N)

  • 이관우;박대희
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2001년도 추계학술대회 논문집
    • /
    • pp.149-152
    • /
    • 2001
  • In this paper, aging diagnosis method of CV cable was investigated. CV cable was designed for the sake of using during 30 years. Therefore it was important to evaluate the cable's remaining life because CV cable used for power transmission line since 1970's. CV cable was mainly installed at the underground owing to the environmental condition. If the cable accident occurred, it needs the much time for the accident recovery and the much damage at the industrial activity. therefore, this paper should study the direct leakage current method, a sort of the cables'aging test method.

  • PDF

Suppression of Leakage Current and Distortion in Variable Capacitance Devices and their Application to AC Power Regulators

  • Katsuki, Akihiko;Oki, Takuya
    • Journal of Power Electronics
    • /
    • 제16권1호
    • /
    • pp.66-73
    • /
    • 2016
  • The quantity of alternating current (AC) leakage and the value of distortion factor in capacitor currents are discussed with regard to a new power component called variable capacitance device (VCD). This component has terminals for controlling its capacitance. Nonlinear dielectric characteristics are utilized in this device to vary the capacitance. When VCD operates in an AC circuit, the AC leakage from this device through direct current (DC) control voltage source increases according to the conditions of DC control voltage and so on. To solve this problem, we propose techniques for suppressing AC leakage. Although VCD has strong nonlinear characteristics, the current through the capacitor is not distorted significantly. The relations between AC leakage and the distortion in current waveforms are investigated. An application example for an AC power regulator is also introduced to evaluate the distortion in waveforms.

전력간선에서의 전자파 장애를 고려한 원칩형 누설전류 원격 검출단말기의 개발 (An Development of Leakage Current Sensing Module of the System on Chip Type Under Consideration of Electromagnetic Interface in Power Trunk Line)

  • 김동완;박지호;박성원
    • 전기학회논문지P
    • /
    • 제58권4호
    • /
    • pp.377-384
    • /
    • 2009
  • In this paper, leakage current sensing module of SoC(System on Chip)type and real time monitoring system under consideration of electromagnetic interface in power trunk line are developed. The first, leakage current sensing module of SoC type under consideration of electromagnetic interface is developed, and the developed sensing module of SoC type is composed of leakage sensing part, power supply part, interface part, communication part, AD(Alternating current to Direct current)convert part and amplification part. And also the electromagnetic compatibility is evaluated by conduction and radiation of EMI(Electromagnetic Interference) for developed sensing module. The developed system can have confidence, stability and do energy saving under mixed electric circumstance of the low voltage communication device and high voltage equipment. The second, the real time remote monitoring system is developed using designed wire and wireless communication module with leakage current sensing module of SoC type. The developed real time remote monitoring system can monitor sensing state, occurrence state of leakage current and alarm for each step etc.. And the device configuration, PCB layout for leakage current sensing module of system on chip type and the experiment configuration in consideration of EMI are presented. Also the measurement results of conduction and radiation for EMI are presented.

자기장학 누설자속법을 응용한 직류전류계측법에 관한 연구 (A Study on Direct Current Measurement Using Magneto-Optical LMF Method)

  • 이진이
    • 비파괴검사학회지
    • /
    • 제24권6호
    • /
    • pp.566-572
    • /
    • 2004
  • 금속성 도선 뿐 아니라 기상 또는 액상의 직류전류를 계측하기 위해서는 비접촉으로 전류를 측정할 필요가 있다. 본 논문은 직류전류를 비접촉으로 계측하기 위한 방법 중 하나로써 패러데이효과와 누설자속을 이용하는 방법을 제안하고, 이론적 고찰 및 실험적 검증결과를 보고한다. 공극을 가진 강자성체 코어를 1차 코일에 의하여 자화하면, 공극 주위에는 누설자속이 발생한다. 이러한 누설자속의 수직성분에 의하여 자기광학소자의 자구는 자화되어, 공극의 중심과 자벽은 평행하게 된다. 한편, 2차 코일에 의하여 자기광학소자에 수직한 방향으로 자장을 인가하면, 누설자속분포는 공극의 중심을 기준으로 좌우 대칭이었던 자구의 분포에 편향이 발생한다. 이때 금속, 기체 또는 액체상태의 전류가 코어를 통과하면 자기광학소자의 자벽이 이동하게 된다. 이러한 원리에 의하여 자구 또는 자벽의 이동량을 측정하면, 코어를 통과하는 직류전류의 세기를 알 수 있다.

XLPE의 수트리와 절연파괴 현상에 관한 연구 (A Study on Phenomena of Watertree and Dielectric Breakdown in XLPE)

  • 이성일
    • 대한안전경영과학회지
    • /
    • 제3권4호
    • /
    • pp.45-52
    • /
    • 2001
  • In order to Investigate water tree degradation behavior on XLPE cable, direct voltage of 200 to 800V has been applied to the material at 5$0^{\circ}C$~10$0^{\circ}C$, and the water tree property has been correlated with voltage and temperature. The leakage current was increase as temperature increased and the Ohm's law was generally satisfied in this experiment though some experimental errors were found. The leakage current was decreased and reached to the stable state with time. It was also shown that the time for the stabilization of leakage current was lessened as voltage increased

  • PDF

Experimental Study for Gate Trap and Generation Current using DCIV Method

  • Kim, Young Kwon;Lee, Dong Bin;Choi, Won Hyeok;Park, Taesik;Lee, Myoung Jin
    • KEPCO Journal on Electric Power and Energy
    • /
    • 제2권2호
    • /
    • pp.223-225
    • /
    • 2016
  • The newly proposed analysis method using a direct-current current-voltage (DCIV) simulation is introduced for investigating leakage current composing MOS transistor. From comparing the density and location of traps using DCIV method and investigating the leakage current of gate channel transistor, we proposed the graphical analysis method to correlate the DCIV current and leakage mechanism by the traps. And, our graphical method intuitively explains that leakage current in MOS transistor is well correlated with the DCIV current of the MOS transistor arrays due to two kinds of traps created by Fowler-Nordheim (F-N) stress and Hot carrier stress, respectively.

반도체 레이저의 전류 차단층 구조들이 정적 및 동적특성에 미치는 영향 (The structural dependence of current blocking layers on the static and dynamic performances in a direct modulated semiconductor laser)

  • 김동철;심종인;박문규;강중구;방동수;장동훈;어영선
    • 한국광학회지
    • /
    • 제14권4호
    • /
    • pp.423-428
    • /
    • 2003
  • 직접 변조형 반도체 레이저 다이오드에서 전류차단층의 구조들이 누설전류 및 대역폭에 미치는 영향을 조사하였다. 전류차단층을 통한 누설전류는 전류-전압미분특성 곡선을 통하여, 전류차단층의 기생성분들이 대역폭에 미치는 영향은 차감법(Subtraction method)을 사용하여 분석하였다. 실험결과로부터 정적 및 동적특성에 동시에 우수한 특성을 보이는 전류차단층 구조로서‘inin’형 차단구조가 매우 효과적임을 밝혔다.

Electrical Behaviors of ZnO Elements under Combined Direct and Alternating Voltages

  • Yang, Soon-Man;Lee, Bok-Hee;Paek, Seung-Kwon
    • Journal of Electrical Engineering and Technology
    • /
    • 제4권1호
    • /
    • pp.111-117
    • /
    • 2009
  • This paper presents the characteristics of leakage currents flowing through zinc oxide (ZnO) surge arrester elements under the combined direct-current (DC) and 60 Hz alternating-current (AC) voltages. The current-voltage characteristic curves (I-V curves) of the commercial ZnO surge arrester elements were obtained as a function of the voltage ratio a. At constant peak value of the combined DC and AC voltage, the resistive leakage current of the ZnO blocks was significantly increased as the voltage ratio $\alpha$ increased. The I-V curves under the combined DC and AC voltages were placed between the pure DC and AC characteristics, and the cross-over phenomenon in both the I-V curves and R-V curves was observed at the low current region. The ZnO power dissipation for DC voltages was less than that for AC voltage in the pre-breakdown region and reversed at higher voltages.