• 제목/요약/키워드: Direct extraction

검색결과 342건 처리시간 0.03초

Sensitive determination of pendimethalin and dinoseb in environmental water by ultra performance liquid chromatography-tandem mass spectrometry

  • Lim, Hyun-Hee;Park, Tae-Jin;Lee, Soo-Hyung;Shin, Ho-Sang
    • 분석과학
    • /
    • 제30권4호
    • /
    • pp.194-204
    • /
    • 2017
  • Direct injection (DI) and solid phase extraction (SPE) methods for the simultaneous determination of pendimethalin (PDM) and dinoseb (DNS) in environmental water have been optimized using the ultra performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS) method. The limits of quantification (LOQs) of PDM and DNS were $0.01{\mu}g/L$ using the DI method and $0.0001-0.0002{\mu}g/L$ using the SPE method. The precision by SPE UPLC-MS/MS was less than 11 % for intra-day and inter-day analyses. When the proposed SPE method was used to analyze two analytes in environmental water, PDM was detected in a concentration range of $0.0002-0.011{\mu}g/L$ in 31 samples of the 114 surface water samples, and DNS was detected in a concentration range of $0.0005-0.045{\mu}g/L$ in 17 samples of the 114 surface water samples analyzed. When the DI method was used to analyze target compounds in the same samples, the detected concentrations of the two analytes were within 21% in samples with concentrations above $0.01{\mu}g/L$. The DI UPLC-MS/MS method can thus be used for the routine monitoring of PDM and DNS in environmental water, and the SPE LC-MS/MS method can be used for the determination of the ultra-trace PDM and DNS residues in environmental water.

PCA-optimized 필터뱅크 기반의 MFCC 특징파라미터 추출 및 한국어 4연숫자 전화음성에 대한 인식실험 (Extraction of MFCC feature parameters based on the PCA-optimized filter bank and Korean connected 4-digit telephone speech recognition)

  • 정성윤;김민성;손종목;배건성
    • 대한전자공학회논문지SP
    • /
    • 제41권6호
    • /
    • pp.279-283
    • /
    • 2004
  • 음성신호의 스펙트럼으로부터 MFCC를 추출할 때, 일반적으로 필터뱅크의 처리과정에서 삼각형 형태의 필터를 사용한다. 그러나 더 나은 인식성능을 위해, 훈련 음성데이터의 스펙트럼에 PCA를 적용하여 필터뱅크의 필터형태를 최적화하는 PCA-optimized 필터뱅크 방법이 Lee et al. 에 의해 제안되었다. 본 논문에서는 대용량의 4연숫자 전화음성 DB를 사용하여PCA-optimized 필터뱅크 기반의 MFCC 특징파라미터를 추출하고 인식실험을 수행한 후, 기존의 삼각형 형태의 필터를 사용하는 MFCC와 각 대역별 로그에너지로 가중시켜서 얻어지는 MFCC와의 인식성능을 비교하였다. 실험결과, PCA-optimized 필터뱅크 기반의 MFCC 특징파라미터가 기존의 삼각형 형태의 필터뱅크 기반 MFCC에 비해 조금 향상된 인식률을 나타내었지만, 각 대역별 로그에너지로 가중치를 주어 얻어지는 MFCC보다는 인식률이 떨어졌다.

Production of Group Specific Monoclonal Antibody to Aflatoxins and its Application to Enzyme-linked Immunosorbent Assay

  • Kim, Sung-Hee;Cha, Sang-Ho;Karyn, Bischoff;Park, Sung-Won;Son, Seong-Wan;Kang, Hwan-Goo
    • Toxicological Research
    • /
    • 제27권2호
    • /
    • pp.125-131
    • /
    • 2011
  • Through the present study, we produced a monoclonal antibody against aflatoxin B1 (AFB1) using AFB1-carboxymethoxylamine BSA conjugates. One clone showing high binding ability was selected and it was applied to develop a direct competitive ELISA system. The epitope densities of AFB1-CMO against BSA and KLH were about 1 : 6 and 1 : 545, respectively. The monoclonal antibody (mAb) from cloned hybridoma cell was the IgG1 subclass with ${\lambda}$-type light chains. The $IC_{50}s$ of the monoclonal antibody developed for AFB1, AFB2, AFG1 and AFG2 were 4.36, 7.22, 6.61 and 29.41 ng/ml, respectively, based on the AFB1-KLH coated ELISA system and 15.28, 26.62, 32.75 and 56.67 ng/ml, respectively, based on the mAb coated ELISA. Cross-relativities of mAb to AFB1 for AFB2, AFG1 and AFG2 were 60.47, 65.97 and 14.83% in the AFB1-KLH coated ELISA, and 59.41, 46.66 and 26.97% in the mAb coated ELISA, respectively. Quantitative calculations for AFB1 from the AFB1-Ab ELISA and AFB1-Ag ELISA ranged from 0.25 to 25 ng/ml ($R^2$ > 0.99) and from 1 to 100 ng/ml ($R^2$ > 0.99), respectively. The intra- and inter-assay precision CVs were < 10% in both ELISA assay, representing good reproducibility of developed assay. Recoveries ranged from 79.18 to 91.27%, CVs ranged from 3.21 to 7.97% after spiking AFB1 at concentrations ranging from 5 to 50 ng/ml and following by extraction with 70% methanol solution in the Ab-coated ELISA. In conclusion, we produced a group specific mAb against aflatoxins and developed two direct competitive ELISAs for the detection of AFB1 in feeds based on a monoclonal antibody developed.

막 증발법을 이용한 셰일가스 폐수 처리 가능성 평가 (Feasibility study on shale gas wastewater treatment using membrane distillation)

  • 조형락;최용준;이상호
    • 상하수도학회지
    • /
    • 제30권4호
    • /
    • pp.441-447
    • /
    • 2016
  • Development of shale gas has drawn increasing attention since it is one of promising alternative energy resources. However, contamination of groundwater and surface water during the extraction of shale gas is becoming a serious environmental issues, which brings the needs to treat wastewater generated from hydraulic fracking. In this study, the feasibility of membrane distillation (MD) for the treatment of shale gas wastewater was investigated using a laboratory scale experimental setup. Flat-sheet MD membranes were used to treat produced water from a shale gas well in the United States. Different configurations such as direct contact MD (DCMD) and air gap MD (AGMD) were compared in terms of flux and fouling propensity. The foulants on the surface of the membranes were examined. The results suggest that MD can treat the shale gas produced water containing more than 200,000 mg/L of total dissolved solids, which is impossible by other technologies such as reverse osmosis (RO) and forward osmosis (FO). In this study, we investigated the possibility of processing and characterization of shale gas produce wastewater using membrane distillation. Laboratory scale membrane distillation experimental device was developed. It was compared the flat-sheet direct contact membrane distillation and flat-sheet air gap membrane distillation. AGMD flux in lower than the flux of DCMD, it was expected that the contamination caused by organic matters.

직접파를 이용한 배경매질 유속정보 도출과 유속을 고려한 파형역산의 적용 (Extraction of Flow Velocity Information using Direct Wave and Application of Waveform Inversion Considering Flow Velocity)

  • 이다운;정우근;신성렬;배호석
    • 지구물리와물리탐사
    • /
    • 제20권4호
    • /
    • pp.199-206
    • /
    • 2017
  • 해상탐사에서 얻어지는 현장자료는 바람, 파도, 조류, 배경매질의 유속 등 다양한 환경요소에 영향을 받는다. 배경매질의 유속을 제외한 대부분의 환경요소는 자료처리 단계에서 적절한 보정이 이루어지고 있다. 본 연구에서는 배경매질의 유속정보가 파형역산에 미치는 영향을 분석하기 위해 배경매질의 유속정보를 고려하는 파동 방정식 모델링을 활용하여 관측자료를 생성하고, 생성된 자료를 통해 수치 실험을 진행하였다. 수치예제에는 다소 비현실적인 유속이 적용된 결과도 포함되어 있다. 이와 더불어, 탐사자료의 유속정보를 수치적 기법으로 도출하여 역산을 수행하는 알고리즘을 제안하였다. 제안된 알고리즘은 수정된 Marmousi2 모델에 적용하여 유속에 따른 결과를 얻고자 하였다. 기존의 유속을 고려하지 않은 역산 결과와 제안된 알고리즘으로 수행한 역산 결과 비교를 통해 유속의 세기가 갱신되는 물성정보에 미치는 영향을 확인하였다.

Efficiency Improvement in InGaN-Based Solar Cells by Indium Tin Oxide Nano Dots Covered with ITO Films

  • Seo, Dong-Ju;Choi, Sang-Bae;Kang, Chang-Mo;Seo, Tae Hoon;Suh, Eun-Kyung;Lee, Dong-Seon
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2013년도 제44회 동계 정기학술대회 초록집
    • /
    • pp.345-346
    • /
    • 2013
  • InGaN material is being studied increasingly as a prospective material for solar cells. One of the merits for solar cell applications is that the band gap energy can be engineered from 0.7 eV for InN to 3.4 eV for GaN by varying of indium composition, which covers almost of solar spectrum from UV to IR. It is essential for better cell efficiency to improve not only the crystalline quality of the epitaxial layers but also fabrication of the solar cells. Fabrication includes transparent top electrodes and surface texturing which will improve the carrier extraction. Surface texturing is one of the most employed methods to enhance the extraction efficiency in LED fabrication and can be formed on a p-GaN surface, on an N-face of GaN, and even on an indium tin oxide (ITO) layer. Surface texturing method has also been adopted in InGaN-based solar cells and proved to enhance the efficiency. Since the texturing by direct etching of p-GaN, however, was known to induce the damage and result in degraded electrical properties, texturing has been studied widely on ITO layers. However, it is important to optimize the ITO thickness in Solar Cells applications since the reflectance is fluctuated by ITO thickness variation resulting in reduced light extraction at target wavelength. ITO texturing made by wet etching or dry etching was also revealed to increased series resistance in ITO film. In this work, we report a new way of texturing by deposition of thickness-optimized ITO films on ITO nano dots, which can further reduce the reflectance as well as electrical degradation originated from the ITO etching process.

  • PDF

PCR을 이용한 육류 내 Salmonella sp. 및 Salmonella Typhimurium 분리 검출 (Selective Detection of Salmonella sp. and Salmonella Typhimurium in Meat by Polymerase Chain Reaction)

  • 주종원;홍경표;김용휘;조상범
    • 동아시아식생활학회지
    • /
    • 제19권2호
    • /
    • pp.295-300
    • /
    • 2009
  • 본 연구에서는 육류 식품 시료에서 단시간 내에 살모넬라를 검출하기 위하여 PCR을 이용한 검출용 프라이머들의 특이성과 민감성을 평가하였다. 실험에 사용된 프라이머들은 Salmonella Typhimurium의 mdh와 invA 유전자의 염기서열에 기초하여 제작되었다. 각각의 primer들의 검출 감도를 평가하여 최종적으로 broad spectrum primer SLM1과 S. Typhimurium specific primer SLT4를 선발하였다. 또한, 시료에 오염된 병원균의 최소 검출량이 어느 정도인지를 확인하기 위하여 살모넬라 균수를 reaction tube당 $10^0{\sim}10^3$ cell까지 다양하게 하여 검출 감도를 측정한 결과, 최소 1 cell에서도 PCR 산물을 나타내어 검출 감도가 매우 우수한 것으로 나타났다. 살모넬라 균주를 혼합한 소고기와 돼지고기 시료에서 각각 프라이머들의 검출 감도를 평가한 결과, 증균하지 않은 시료 자체와 세균학적 방법으로 증균 배양한 시료 그리고 증균 배양된 시료로부터 세균의 DNA를 추출한 시료 간에 큰 차이를 나타내지 않았다. 이에 육류 식품에서 살모넬라 혹은 S. Typhimurium의 검출을 위한 프라이머로서 효율적으로 사용이 가능할 것으로 판단된다.

  • PDF

LC-MS/MS를 이용한 콘돔에 함유된 니트로사민류 농도 분석 (Analysis of Nitrosamines Concentration in Condom by using LC-MS/MS)

  • 박나연;김성민;정웅;고영림
    • 대한화학회지
    • /
    • 제62권3호
    • /
    • pp.181-186
    • /
    • 2018
  • 니트로사민류는 이차아민과 아질산이 니트로소화 반응을 통해 생성되는 화합물이며, 고무의 가공시 가황과정을 거치면서 생성되는 것으로 밝혀졌다. 최근 고무제품 중에서 니트로사민류가 검출되면서 큰 이슈가 되고 있다. 콘돔은 인체에 삽입되는 일회용 의료기기로써 피부 및 점막에 직접 접촉하므로 안전성이 매우 중요하다. 이에 본 연구에서는 ISO 29941 방법을 준용하여 콘돔 중 니트로사민류의 분석법을 개발하였다. 콘돔 시료를 증류수에 넣어 용출시키고, 용출액에서 분석대상 물질을 추출하기 위해 디클로로메탄으로 액체-액체 추출을 실시하였으며, 농축 후 LC-MS/MS에서 정량분석하였다. 분석법의 정확도는 85.8~108.7%, 정밀도는 11.5% 이하, 검출한계는 0.11(NDPA, NDBA) ~ 0.48(NPYR) ng/mL이었다. 31건의 콘돔시료 중에서 증류수 용출에 의해 검출된 물질은 NDBA 2건이었고, 인공타액(pH 4.5) 용출로 검출된 물질은 NDMA 1건, NDEA 4건, NDBA 26건이었다. 니트로사민류의 총량은 모든 시료에서 $500{\mu}g/kg$을 초과하지 않았다.

New Methods for Correcting the Atmospheric Effects in Landsat Imagery over Turbid (Case-2) Waters

  • Ahn Yu-Hwan;Shanmugam P.
    • 대한원격탐사학회지
    • /
    • 제20권5호
    • /
    • pp.289-305
    • /
    • 2004
  • Atmospheric correction of Landsat Visible and Near Infrared imagery (VIS/NIR) over aquatic environment is more demanding than over land because the signal from the water column is small and it carries immense information about biogeochemical variables in the ocean. This paper introduces two methods, a modified dark-pixel substraction technique (path--extraction) and our spectral shape matching method (SSMM), for the correction of the atmospheric effects in the Landsat VIS/NIR imagery in relation to the retrieval of meaningful information about the ocean color, especially from Case-2 waters (Morel and Prieur, 1977) around Korean peninsula. The results of these methods are compared with the classical atmospheric correction approaches based on the 6S radiative transfer model and standard SeaWiFS atmospheric algorithm. The atmospheric correction scheme using 6S radiative transfer code assumes a standard atmosphere with constant aerosol loading and a uniform, Lambertian surface, while the path-extraction assumes that the total radiance (L/sub TOA/) of a pixel of the black ocean (referred by Antoine and Morel, 1999) in a given image is considered as the path signal, which remains constant over, at least, the sub scene of Landsat VIS/NIR imagery. The assumption of SSMM is nearly similar, but it extracts the path signal from the L/sub TOA/ by matching-up the in-situ data of water-leaving radiance, for typical clear and turbid waters, and extrapolate it to be the spatially homogeneous contribution of the scattered signal after complex interaction of light with atmospheric aerosols and Raleigh particles, and direct reflection of light on the sea surface. The overall shape and magnitude of radiance or reflectance spectra of the atmospherically corrected Landsat VIS/NIR imagery by SSMM appears to have good agreement with the in-situ spectra collected for clear and turbid waters, while path-extraction over turbid waters though often reproduces in-situ spectra, but yields significant errors for clear waters due to the invalid assumption of zero water-leaving radiance for the black ocean pixels. Because of the standard atmosphere with constant aerosols and models adopted in 6S radiative transfer code, a large error is possible between the retrieved and in-situ spectra. The efficiency of spectral shape matching has also been explored, using SeaWiFS imagery for turbid waters and compared with that of the standard SeaWiFS atmospheric correction algorithm, which falls in highly turbid waters, due to the assumption that values of water-leaving radiance in the two NIR bands are negligible to enable retrieval of aerosol reflectance in the correction of ocean color imagery. Validation suggests that accurate the retrieval of water-leaving radiance is not feasible with the invalid assumption of the classical algorithms, but is feasible with SSMM.

치과에서 디지털 x-선 영상의 이용 (Digital X-ray Imaging in Dentistry)

  • 김은경
    • 치과방사선
    • /
    • 제29권2호
    • /
    • pp.387-396
    • /
    • 1999
  • In dentistry. RadioVisioGraphy was introduced as a first electronic dental x-ray imaging modality in 1989. Thereafter. many types of direct digital radiographic system have been produced in the last decade. They are based either on charge-coupled device(CCD) or on storage phosphor technology. In addition. new types of digital radiographic system using amorphous selenium. image intensifier etc. are under development. Advantages of digital radiographic system are elimination of chemical processing, reduction in radiation dose. image processing, computer storage. electronic transfer of images and so on. Image processing includes image enhancement. image reconstruction. digital subtraction, etc. Especially digital subtraction and reconstruction can be applied in many aspects of clinical practice and research. Electronic transfer of images enables filmless dental hospital and teleradiology/teledentistry system. Since the first image management and communications system(IMACS) for dentomaxillofacial radiology was reported in 1992. IMACS in dental hospital has been increasing. Meanwhile. researches about computer-assisted diagnosis, such as structural analysis of bone trabecular patterns of mandible. feature extraction, automated identification of normal landmarks on cephalometric radiograph and automated image analysis for caries or periodontitis. have been performed actively in the last decade. Further developments in digital radiographic imaging modalities. image transmission system. imaging processing and automated analysis software will change the traditional clinical dental practice in the 21st century.

  • PDF