• 제목/요약/키워드: Direct detection

검색결과 930건 처리시간 0.031초

CRC8 Implementation using Direct Table Algorithm (테이블 기반 알고리즘을 이용한 CRC8의 구현)

  • Seo, Seok-Bae;Kim, Young-Sun;Park, Jong-Euk;Kong, Jong-Phil;Yong, Sang-Soon;Lee, Seung-Hoon
    • Aerospace Engineering and Technology
    • /
    • 제13권2호
    • /
    • pp.38-46
    • /
    • 2014
  • CRC (Cyclic Redundancy Codes) is a error detection method for the date transmission, which is applied to the GRDDP (GOES-R Reliable Data Delivery Protocol) between satellite and GEMS (Geostationary Environmental Monitoring Sensor) on the GEO-KOMPSAT 2B development. This paper introduces a principle of the table based CRC, and explains software implementation results of the CRC8 applied to GEMS.

Introduction to IEC Standardization for Superconducting Sensors and Detectors

  • Ohkubo, M.
    • Progress in Superconductivity
    • /
    • 제14권2호
    • /
    • pp.106-109
    • /
    • 2012
  • Superconducting sensors and detectors have been applied to many fields or beginning to enter the maturing stage. The applications spread over a wide range of fields such as radio telescope, medical examination, quantum information, contamination inspection, materials analysis, etc. For users of the superconducting devices as well as developers, we have to avoid confusion of naming, graphical circuit symbols, and measurement methods for device performance. We are trying to formulate international standards under the International Electrotechnical Commission - Technical Committee 90 (IEC-TC90), which is responsible for superconductivity. The sensors and detectors to be considered are divided into two groups: coherent sensors (SQUID, SIS mixers, etc.) and direct detectors (TES, STJ, MKID, SSPD, etc.).

An Efficient Code Acquisition Scheme for DSSS-based Real-Time Locating Systems

  • Lim, Jong-Tae;Park, Hyung-Rae
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • 제36권1A호
    • /
    • pp.41-48
    • /
    • 2011
  • This paper proposes an efficient code acquisition scheme for direct-sequence spread spectrum (DSSS) based real-time locating systems (RTLS). The proposed scheme employs multiple bit integration to significantly decrease false alarms when no packet signal is transmitted and increase the detection probability when the RTLS tags are excited. The performance of the proposed code acquisition scheme is analyzed and numerically evaluated, and compared with those of single-dwell and traditional double-dwell code acquisition schemes. The simulation results show that the proposed multiple-bit integration scheme outperforms single-dwell and double-dwell schemes.

Real-time Voltammetric Assay of Cadmium Ions in Plant Tissue and Fish Brain Core

  • Ly, Suw-Young
    • Bulletin of the Korean Chemical Society
    • /
    • 제27권10호
    • /
    • pp.1613-1617
    • /
    • 2006
  • Optimum analytical conditions for cyclic voltammetry (CV) and square wave (SW) stripping voltammetry were determined using mercury-mixed carbon nanotube paste electrode (PE). The results approached the microgram working ranges of SW: 10.0-80.0 $ugL^{-1}$ and CV: 100-700 $ugL^{-1}$ Cd (II); working conditions of 300-Hz frequency, 100 mV amplitude, 1.6 V accumulation potential, 400 sec accumulation time, and 40 mV increment potential. First, analysis was performed through direct assay of cadmium ions deep into the fishs brain core and plant tissue in real time with a preconcentration time of 400 sec. The relative standard deviation of 10.0 $mgL^{-1}$ Cd (II) observed was 0.064 (n = 12) at optimum conditions. The low detection limit (S/N) was set at 0.6 $ugL^{-1}$ ($5.33{\times}10^{-9}$ M). The methods can be used in direct analysis in vivo or in real-time monitoring of plant tissue.

Analytical Techniques Using ICP-MS for Clinical and Biological Analysis

  • Ko, Jungaa;Lim, H. B.
    • Mass Spectrometry Letters
    • /
    • 제6권4호
    • /
    • pp.85-90
    • /
    • 2015
  • This article reviews recent analytical techniques using inductively coupled plasma-mass spectrometry (ICP-MS) immunoassay for clinical and bio analysis. We classified the techniques into two categories, direct and indirect analysis, which depend upon a guideline of whether tagging materials are used or not. Direct analysis is well known, and generally used in conjunction with various other techniques, such as laser ablation, chromatographic separations, etc. Recently, indirect analysis using tagging elements has intensively been discussed because of its importance in future applications to bio and clinical analysis, including environmental and food industries. The method has shown advantages of multiplex detection, excellent sensitivity, and short analysis time owing to signal amplification and magnetic separation. Now, it expands the application field from small biomolecules to large cells.

Acquisition performance of a direct-sequence spread-specturm multiple-access system in a multipath fading channel (다중경로 페이딩 전송로에서 직접시퀀스 확산대역 다원접속 시스템의 포착성능)

  • 김진영;이재홍
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • 제21권5호
    • /
    • pp.1230-1239
    • /
    • 1996
  • This paper analyzes matched-filter acquistion performance of a direct-sequence spread-specturm multiple-access system in a Rayleigh fading channel. For an application of multiple access system, multiple access interference is considered in the performance analysis. A signal flow graph technique is used to derive mean acquisition time in terms of detection and false alarm probabilities. As aresult of performance analysis, it is shown that mean acquisition time increases as fading rate becomes faster andthe numbre of users increases, and it decreases as a matched-filter length becomes logner. The variation of parameter values hs much influence on acquisition performance as SNR/chip becomes smaller.

  • PDF

Development of Direct Analysis of Metal and Non-metal Ions in Aqueous Samples with the Moderate Power Helium Microwave Induced Plasma (중급 출력 마이크로파 유도 플라즈마를 이용한 금속 및 비금속 수용액시료의 직접 분석법의 개발)

  • Park, Yong-Nam
    • Journal of the Korean Chemical Society
    • /
    • 제35권6호
    • /
    • pp.699-706
    • /
    • 1991
  • The moderate power (500 W) Microwave Induced Plasma was generated with helium gas and was used for the direct analysis of aqueous samples. Usually, the helium plasma obtained with a modified Beenakker type cavity forms a cylindrical one. Though, by the careful controls of gas flows, a "toroidal" shape plasma could be made but its analytical performances were found to be worse. Using the glass frit nebuliser, the detection limits for metal ions obtained were around 10~100 ppb and that for chloride was about 50ppm.

  • PDF

Detection of Rifampin Resistance Mutation and Its Altered Nucleotide Sequences in Mycobacterium leprae Isolated from Korean Patients with Leprosy

  • Kim, Soon-Ok;Kim, Min-Joo;Tae, Chae-Gue;Suh, Joo-Won
    • Journal of Microbiology
    • /
    • 제34권3호
    • /
    • pp.236-240
    • /
    • 1996
  • Rifampin is the most powerful drug for treating leprosy and tuberculosis today. It inhibits initiation and elongation of RNA transcription by binding to $\beta$-subunit of RNA polymerase, leading to kill mycobacteria. We isolated one variant strain of Mycobacterium leprae from 24 Korean leprosy patients who are less susceptible to rifampin or have suffered from relapse by polymerase chain reaction and single strand conformation polymorphism (PCR-SSCP) of the rpoB gene. Direct sequencing of the rpoB region of M. leprae variant revealed missense mutations which altered the amino acids sequenceof RpoB to Ser-464, Arg-465, Arg-467 and Ala-468. This is the first finding on rpoB gene mutation of M. leprae from Korean patients ; moreover the mutant type was found to be different from the previously reported cases in other countries.

  • PDF

The Principles and Metrical Applications of Immunocsensors (면역센서의 원리와 의학적 응용)

  • 김의락;백세환
    • KSBB Journal
    • /
    • 제17권2호
    • /
    • pp.121-136
    • /
    • 2002
  • Immunosensors are of great interest because of their potential utility as specific, simple, label-free, direct detection means and provision of reduction in size, cost and time of analysis comparing with conventional immunoassay. In the last two decades, many reports have been published on the use of immunosensors for a wide range of applications to clinical diagnostics, pharmaceutical chemistry, environmental monitoring, biotechnology and food industries. There are also numerous transduction techniques developed such as electrochemical techniques, piezoelectric crystal, and surface plasmon resonance receiving much attention for the direct monitoring of immune reactions at solid surfaces. In this article, the principles, characteristics, structures, fonctions and clinical applications of immunosensors were reviewed

Comparison and Analysis of the MC DS-CDMA/MPSK and DS-CDMA/MPSK Systems in Nakagami Fading (나카가미 감쇄에서 MC DS-CDMA/MPSK와 DS-CDMA/MPSK 시스템 비교 분석)

  • 이정도;강희조
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • 제10권6호
    • /
    • pp.951-958
    • /
    • 1999
  • Multicarrier modulation or orthogonal frequency division multiplexing(OFDM) is a promising technique for mobile communications systems, since it has a strong immunity to multipath fading without employing complicated adaptive equalization. In this paper, performance of MC DS-CDMA/MPSK(multi-carrier direct sequence-code division multiple access/mary phase shift keying) and DS-CDMA/MPSK(direct sequence-code division multiple access/mary phase shift keying) with coherent detection for a CDMA system over Nakagami fading channel analysis. For a given bandwidth, it is shown that MC DS-CDMA/MPSK eventually outperforms DS-CDMA MPSK with random sequences.

  • PDF