• 제목/요약/키워드: Direct cooling

검색결과 308건 처리시간 0.023초

INVESTIGATIONS ON THE RESOLUTION OF SEVERE ACCIDENT ISSUES FOR KOREAN NUCLEAR POWER PLANTS

  • Kim, Hee-Dong;Kim, Dong-Ha;Kim, Jong-Tae;Kim, Sang-Baik;Song, Jin-Ho;Hong, Seong-Wan
    • Nuclear Engineering and Technology
    • /
    • 제41권5호
    • /
    • pp.617-648
    • /
    • 2009
  • Under the government supported long-term nuclear R&D program, the severe accident research program at KAERI is directed to investigate unresolved severe accident issues such as core debris coolability, steam explosions, and hydrogen combustion both experimentally and numerically. Extensive studies have been performed to evaluate the in-vessel retention of core debris through external reactor vessel cooling concept for APR1400 as a severe accident management strategy. Additionally, an improvement of the insulator design outside the vessel was investigated. To address steam explosions, a series of experiments using a prototypic material was performed in the TROI facility. Major parameters such as material composition and void fraction as well as the relevant physics affecting the energetics of steam explosions were investigated. For hydrogen control in Korean nuclear power plants, evaluation of the hydrogen concentration and the possibility of deflagration-to-detonation transition occurrence in the containment using three-dimensional analysis code, GASFLOW, were performed. Finally, the integrated severe accident analysis code, MIDAS, has been developed for domestication based on MELCOR. The data transfer scheme using pointers was restructured with the modules and the derived-type direct variables using FORTRAN90. New models were implemented to extend the capability of MIDAS.

아이스슬러리형 빙축열 시스템을 이용한 냉각 시스템의 성능에 관한 실험적 연구 (Characteristic Analysis of the Cooling System Using Ice Slurry Type Heat Storage System)

  • 이동원;김정배
    • 에너지공학
    • /
    • 제20권1호
    • /
    • pp.30-35
    • /
    • 2011
  • 2중관형과 판형 열교환기에 에틸렌 클리콜-물 수용액으로 만들어진 아이스슬러리를 적용하는 경우의 유동 및 열적 특성을 규명하기 위하여 실험을 수행하였다. 아이스슬러리의 질량유속과 얼음 분율은 각각 800에서 3500 kg/$m^2s$과 0에서 25%이었다. 실험을 통해, 압력강하와 열전달율은 질량유속과 얼음 분율에 따라 증가하였다. 그러나 얼음 분율의 효과는 높은 질량유속 영역에서는 크지 않은 것으로 나타났다. 낮은 질량유속에서는 압력강하와 열전달율의 급속한 증가가 질량 유속에 관계되는 것으로 나타났다.

Growth of GaAs Crystal by an Improved VGF Apparatus

  • Chul-Won Han;Kwang-Bo Shim;Young-Ju Park;Seung-Chul Park;Suk-Ki Min
    • 한국결정성장학회지
    • /
    • 제1권1호
    • /
    • pp.17-25
    • /
    • 1991
  • The construction details of VGF apparatus with a DM(direct monitoring) furnace for the growth of low defect crystal and characteristics of GaAs crystal grown by this apparatus are described. The average dislocation densities and EL2 concentration of as-grown undoped GaAs along the different solidified fractions exhibit $4{\times}10^{2}-7{\times}10^{3}cm^{-2}$ and $6{\times}10^{14}-4{\times}10^{15}cm^{-3}$, which are less than those observed for liquid encapsulated Czochralski(LEC) or high-pressure vertical gradient freeze(VGF) crystals. These remarkable reduction of the dislocation densities and EL2 concentrations were explained by the lower temperature gradient ($dT/dx-10^{\circ}/cm$) and slower rates of post - growth cooling ($20^{\circ}C/hr:1240-1000^{\circ}C,\;30^{\circ}C/hr:1000-700^{\circ}C$). Also, The Hall mobilities, carrier concentrations show uniform distribution throughtout 80% of the ingot length.

  • PDF

Performance Evaluation of a Crank-driven Compressor and Linear Compressor for a Household Refrigerator

  • Park, Minchan;Jung, Yoongho;Lee, Jaeyeol;Lee, Jaekeun;Ahn, Youngchull
    • 동력기계공학회지
    • /
    • 제21권5호
    • /
    • pp.5-12
    • /
    • 2017
  • With the difficulties in increasing the efficiency of conventional crank-driven compressors due to mechanical loss, compressor manufacturers have investigated new kinds of compressor such as a free piston compressor mechanism. This study investigates the energy efficiency of two different types of compressor for a household refrigerator. One is the conventional crank-driven compressor, and the other one is a linear compressor. The energy efficiencies of these compressors are evaluated. Experimental results show that the linear compressor has 10% lower power consumption than the brushless direct-current (BLDC) reciprocating compressor. The linear compressor demonstrates excellent energy efficiency by reducing the friction loss. Furthermore, a motor efficiency exceeding 90% is achieved by using a linear oscillating mechanism with a moving magnet. Additionally, the compressor stroke to piston diameter ratio of the oscillating piston in the linear compressor can be adjusted in order to modulate the cooling capacity of the compressor for improved system efficiency.

우리나라-노르웨이 고등어산업의 유통 경쟁력 비교 연구 (Comparison of Distribution Competitiveness of the Mackerel Industry between Korea and Norway)

  • 김대영;강종호
    • 수산해양교육연구
    • /
    • 제27권6호
    • /
    • pp.1685-1692
    • /
    • 2015
  • This study examines the mackerel distribution systems in Norway which has a leading mackerel industry, and has the purpose of analyzing the effects of structural improvements for the development of Korea's mackerel industry. The landing and distribution status of Korea and Norway's mackerel industry was compared, and the effects of structural improvements was analyzed under the assumption that a number of factors would be improved after an analysis of competitiveness. Special features of the landing and distribution systems of mackerel in Norway are Reduction of transportation costs and transportation time through E-auctions, fish Pumps, freshness management using state-of-the-art equipment and technology such as sea water cooling systems, direct landing at processing factories and Automation through fully automated sorting & packaging systems. The distribution competitiveness of Korea and Norway's mackerel industry was compared through the qualitative review of landing time and the length of distribution channel, distribution costs due to differences in trading method, quality and hygiene management and merchandising. For Korea's mackerel industry to have international competitiveness, they must have efficiency throughout the phases of landing, processing and distribution systems as observed in case of Norway.

Interrupting characteristics of the transformer superconducting fault current limiter

  • Hwang, S.H.;Choi, H.W.;Jeong, I.S.;Choi, H.S.
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제19권4호
    • /
    • pp.40-44
    • /
    • 2017
  • This paper analyzed the fault current limiting characteristics of the previously proposed transformer superconducting fault current limiter (TSFCL) interruption system according to its transformer type. The TSFCL interruption system is an interruption technology that combines a TSFCL, which uses a transformer and a superconductor, and a mechanical DC circuit breaker. This technology first limits the fault current using the inductance of the transformer winding and the quench characteristics of the superconductor. The limited fault current is then interrupted by a mechanical DC circuit breaker. The magnitude of the limited fault current can be controlled by the quench resistance of the superconductor in the TSFCL and the turns ratio of the transformer. When the fault current is controlled using a superconductor, additional costs are incurred due to the cooling vessel and the length of the superconductor. When the fault current is controlled using step-up and step-down transformers, however, it is possible to control the fault current more economically than using the superconductor. The TSFCL interruption system was designed using PSCAD/EMTDC-based analysis software, and the fault current limiting characteristics according to the type of the transformer were analyzed. The turns ratios of the step-up and step-down transformers were set to 1:2 and 2:1. The results were compared with those of a transformer with a 1:1 turns ratio.

경사기능성 세라믹/금속 복합재료의 열응력 해석(1)-플라즈마 용사재- (Thermal Stress Analysis of Functuonally Graded Ceramic/Metal Composites(I)-Plasma Spraying Material-)

  • 송준희;임재규;정세희
    • 대한기계학회논문집A
    • /
    • 제21권3호
    • /
    • pp.439-446
    • /
    • 1997
  • A traditional notion of composites has been composed as a uniform dispersoid, but now it is proposed without regard to such rule with process development. Functionally Graded Material(FGM) consists of a new material design that is to make intentionally irregular dispersion state. In this study, thermal stress analysis of plasma spraying PSZ/NiCrAlY gradient material was conducted theoretically using a finite-element program. A formations of the model are direct bonding material(NFGM) and FGM with PSZ and NiCrAlY component element. The temperature conditions were $700^{\circ}C$ to 1100.deg. C assuming a cooling-down precess up to room temperature. Fracture damage mechanism was analyzed by the parameters of residual stress.

태양열 발전용 스크롤 방식 스털링 엔진의 특성 (Characteristics of Scroll-type Stirling Engine for Solar Power)

  • 김영민;신동길;김우영;김현진;이상태
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2008년도 춘계학술대회 논문집
    • /
    • pp.169-173
    • /
    • 2008
  • Stirling engine is a promising heat engine with a high efficiency, muti-fuel capability, low emission, quiet operation, very low maintenance and long life. As one of the promising applications, solar power system based on the Stirling dish, providing net solar-to-electric conversion efficiencies reaching 30%, can operate as stand-alone units in remote locations or can be linked together in groups to provide utility-scale power. This paper introduced a new Scroll-type Stirling engine, being developed for solar power, superior to conventional Stirling engines. The Scroll-type Stirling engine is characterized as traits of continuous and wholly separated compression and expansion; one-way flow system; direct cooling and heating the fluid in the working spaces through the extensive inner surfaces of scroll wraps. All theses traits contribute to achieving thermodynamic cycle closer to the ideal Stirling cycle (exactly speaking, Ericsson cycle).

  • PDF

마우스 핵이식란의 동결에 관한 연구 (Studies on cryopreservation of nuclear transplanted mouse embryos)

  • 이병천;조충호;황우석
    • 대한수의학회지
    • /
    • 제33권1호
    • /
    • pp.171-178
    • /
    • 1993
  • The present study was carried out to investigate the developmental potency to blastocyst after freezing and thawing of nuclear transplanted 2-cell embryos. The nuclei from 2-, 4- and 8-cell mouse embryos were transferred into enucleated 2-cell embryos, and the reconstituted embryos were submitted to direct current(DC) pulse at output voltage of 2.0 kV/cm for $100{\mu}$ sec to induce cell fusion. The recovery rate and developmental potency to blastocyst after freezing and thawing of nuclear transplanted 2-cell embryos was investigated. 1. The recovery rate of nuclear transplanted 2-cell embryos in normal morphology after freezing and thawing was significantly higher in rapid freezing(DMSO 4.5M) than in slow cooling(p<0.01). 2. When the recovered embryos in normal morphology were cultured in vitro, there were no significant differences in the developmental potency to blastocyst between the freezing methods and the concentrations of cryoprotectant. In summary, these experiments have proved that rapid freezing method(DMSO 4.5M) is effective in nuclear transplanted 2-cell mouse embryos. If improved micromanipulation techniques and freezing are combined, nuclear transplantation technique will contribute to the improvement of productivity in livestock animals.

  • PDF

순행성 관관류법과 역행성 관관류법의 임상적 비교연구 (A Comparative Study of Antegrade Cardioplegia Versus Retrograde Cardioplegia for Myocardial Protection during the Open Heart Surgery)

  • 조완재
    • Journal of Chest Surgery
    • /
    • 제22권4호
    • /
    • pp.609-619
    • /
    • 1989
  • During aortic valve surgery, cardioplegic solution is delivered through direct cannulation of both coronary ostia. Since this approach may cause an intimal injury leading to acute dissection or late ostial stenosis, this study was undertaken to evaluate myocardial protective effect of retrograde perfusion of cardioplegia [RCSP <% RRAP] in 18 clinical cases, which were compared with antegrade perfusion of cardioplegia in 27 clinical cases. This study were investigated 1] cease and return of electromechanical activity after cardioplegia infusion 2] the myocardial temperature during operation 3] the aortic cross clamping time and total bypass time 4] frequency of DC shock for defibrillation 5] need for inotropic drugs after operation 6] electrocardiographic evidence of myocardial infarction or ventricular arrhythmia after operation 7] the enzymes activity during preoperative and postoperative period as an evaluation of myocardial ischemic injury and 8] operative mortality rate The combination of retrograde cardioplegia and topical cooling with ice slush yielded promptly hypothermia of myocardium and shorter aortic cross-clamping time compared with antegrade cardioplegia [P < 0.05]. The temperature of the interventricular septum was maintained below 20oC by continuous perfusion or intermittent perfusion of cold blood cardioplegia and other results were no statistically significant difference between the two methods [P >0.05]. This technique provides clear operative field and avoids some serious complications which are caused by coronary ostial cannulation. These results suggested that the retrograde perfusion of cardioplegia is a simple, safe, and effective means of myocardial protection during open heart surgery.

  • PDF