• 제목/요약/키워드: Direct contact

검색결과 996건 처리시간 0.029초

미세노즐을 통해 수직분사된 수증기의 직접접촉응축 영역도 (The regime map for the direct contact condensation of steam vertically injected through a mini nozzle)

  • 이수관;배성효;김무환
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2004년도 추계학술대회
    • /
    • pp.1075-1079
    • /
    • 2004
  • Steam was vertically discharged into water through mini nozzles of various diameters (d=0.115, 0.520, 1.55mm). The condensation was observed and categorized into several types of condensation regimes for each of the nozzles. Compared with the regimes in the previous researches, the regimes of 'internal necking with attached bubble' and 'internal chug with detached bubble' were newly observed. Depending on a nozzle, some regimes expanded, shrank, or moved in the regime map. For the nozzle of 1.55mm, the regime map was similar to Chan and Lee (1982) except that the regime of 'internal chug' was not observed. For the nozzle of 0.115mm, the regime of 'internal chug' appeared even at high pool temperature.

  • PDF

동방향 성층이상유동에서의 직접접촉 응축현상에 대한 해석 (An Analysis on Direct-Contact Condensation in Horizontal Cocurrent Stratified How of Steam and Cold Water)

  • Lee, Sukho;Kim, Hho-Jung
    • Nuclear Engineering and Technology
    • /
    • 제24권2호
    • /
    • pp.130-140
    • /
    • 1992
  • 동방향 성층이상유동에서의 직접적촉 응축현상을 일차원 모델인 RELAP5/MOD2와 /MOD3를 이용하여 해석하였으며, 해석결과를 Northwestern의 실험결과와 비교·검토하였다. 해석결과 RELAP5의 공유열전달 모델은 동방향 성층이상유동에서 응축율을 비교적 잘 예측하고 있다. 그러나 공유접촉면에 파형이 생기는 경우는 물경계두께 및 국부 열전달계수는 유사한 범위로 일치할분 현상을 예측하는데 상당한 차이가 있다.

  • PDF

2차원 관내 유동에서 불활성 기체 제거과정의 직접 수치 해석 (DIRECT NUMERICAL SIMULATION OF IMMISCIBLE GAS BUBBLE DISPLACEMENT IN 2D CHANNEL)

  • 신승원
    • 한국전산유체공학회지
    • /
    • 제12권3호
    • /
    • pp.41-46
    • /
    • 2007
  • Dynamic behavior of immiscible gas bubble attached to the wall in channel flow plays very important role in many engineering applications. Special attention has been paid to micro direct methanol fuel cell(${\mu}$DMFC) where surface tension becomes dominant factor with minor gravitational effect due to its reduced size. Therefore, displacement of $CO_2$ bubble generating on a cathode side in ${\mu}$DMFC can be very difficult and efficient removal of $CO_2$ bubbles will affect the overall machine performance considerably. We have focused our efforts on studying the dynamic behavior of immiscible bubble attached to the one side of the wall on 2D rectangular channel subject to external shear flow. We used Level Contour Reconstruction Method(LCRM) which is the simplified version of front tracking method to track the bubble interface motion. Effects of Reynolds number, Weber number, advancing/receding contact angle and property ratio on bubble detachment characteristic has been numerically identified.

비접촉식 센서를 사용한 형상 측정 연구 (A Study of Form Measurement using Noncontact Sensor)

  • 송정섭;황윤호;배종일;이만형
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 1995년도 추계학술대회 논문집
    • /
    • pp.407-410
    • /
    • 1995
  • Many researches on measurement technology has been made and developed by various methods. Considering the measurement environment with cutting fluid, coolant and the like, contact type measurement methods are mostly used. But contact measurement method has measuring force and so the sensing head becomes worn. By these reasons, we considered sensors not influenced by the former fluid and so can acquire accrate measured values using error compensation due to temperature and vibration. For this purpose, eddy current sensors and Extended kalman Filter Algorithm for processing measured data has been used. In this paper, we present new technology that can be used for measuring workpiece with previous bad environment using direct method and comparison measurement method. We used cylindrical workpieces which were produced by grinding machine for the target.

  • PDF

증기제트 방출시 과냉각수조 내의 열혼합 현상 CFD 해석 (CFD Analysis for Thermal Mixing in a Subcooled Water during Steam Jet Discharge)

  • 강형석;송철화
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 2006년 제4회 한국유체공학학술대회 논문집
    • /
    • pp.513-514
    • /
    • 2006
  • A CFD analysis for a thermal mixing experiment during steam jet discharge was performed to develop the analysis methodology for the thermal mixing between steam and subcooled water and to find the optimized numerical method. In the CFD analysis, the steam condensation phenomena by a direct contact was modelled by the so-called condensation region model. The comparison of the CFD results with the test data showed a good agreement as a whole, but a small temperature difference was locally found at some locations. However, the commercial CFD code of CFX4.4 together with the condensation region model can simulate the thermal mixing behaviour reasonably well when a sufficient number of mesh distribution and a proper numerical method are adopted

  • PDF

급속 열처리 시스템을 위한 물/공기 액적류 충돌 제트의 냉각 특성에 관한 연구 (Cooling Performance of Air/Water Mist Jet Impinging for a Rapid Thermal Annealing System)

  • 이준경
    • 한국기계가공학회지
    • /
    • 제14권5호
    • /
    • pp.68-74
    • /
    • 2015
  • In the present work, a series of numerical calculations have been conducted on the cooling of a hot surface using an air/water mist jet. In some cooling processes, such as in the glass-tempering process, direct contact between the cold water drops and the hot surface should be avoided, because this may cause surface cracks due to the sharp temperature gradients. Thus, the main focus of this study is finding the appropriate operating conditions for maximum cooling without direct contact between the drops and the surface. A series of numerical experiments have been performed, and, at the same time, those results were compared with those of the previous experiments for verification purposes. The effects of droplet impinging velocity, hot plate temperature, and liquid loading ratio for mono-dispersed drops of various sizes were studied in detail.

Improvement of Direct Contact Condensation Model of RELAP5/MOD3.1 for Passive High-Pressure Injection System

  • Lee, Sang-Il;No, Hee-Cheon
    • 한국원자력학회:학술대회논문집
    • /
    • 한국원자력학회 1996년도 춘계학술발표회논문집(2)
    • /
    • pp.368-373
    • /
    • 1996
  • A simple set of the transition criterion of the condensation regimes and the heat transfer coefficients on the direct contact condensation of the core makeup tank is developed, and implemented in RELAP5/MOD3.1 The condensation regimes are divided into two regimes: supply limit and condensation limit. In mode]ing the transition criterion between two regimes, a large-eddy model developed by Theofanous is used, and the empirical coefficient of the present large-eddy model is close to that of the large-eddy model. It turns out that the modified code better predicts the experimental data, especially the injection flow rate and the water level trend than the original code does.

  • PDF

The southeastern region of the Vela SNR

  • Kim, Il-Joong;Seon, Kwang-Il;Min, Kyoung-Wook
    • 천문학회보
    • /
    • 제35권2호
    • /
    • pp.69.2-69.2
    • /
    • 2010
  • We investigate the southeastern region of the Vela supernova remnant (SNR) in the multi-wavelength domains. This region is quite interesting because it includes the bullet feature D/D´ and another SNR (the Vela Jr.). The C IV $\lambda\lambda1548$, 1551 emission-line morphologies obtained from the FIMS/SPEAR data show that there are several local peaks of C IV on the bullet D/D´ and the Vela Jr. SNR. This may provide clues to direct interaction between both SNRs. Also, we found that the southeastern side of the Vela is in direct contact with an H-alpha ring feature whose central source seems to be a B-type star, HD 76161. The C IV emission peaks along this contact boundary. We investigate this interacting region in detail.

  • PDF

Image Reconstruction of Dispersed Phases in DCHXs

  • Wongee Chun;Kim, Min-Chan;Lee, Heon-Ju;Lee, Yoon-Joon;Kang, Yong-Heack;Kim, Hyung-Taek
    • 에너지공학
    • /
    • 제10권2호
    • /
    • pp.83-89
    • /
    • 2001
  • This paper studies the possibility of applying the EIT(Electrical Impedance Tomography) technique for investigating the formation and movement of dispersed phase droplets as they stream through a Direct Contact Heat Exchanger(DCHX). In most direct contact liquid-liquid heat exchangers, oil or hydro-carbon with a density different (lighter or heavier) from water is normally used as dispersed working fluid. The main difficulty that arises with arrangement lies in the extraction of performance parameters and visualization of dispersed phase fluids if required. In order to delve into these problems, this paper introduces a number of cases regarding the operation and principle of DCHXs and investigates the possibility of applying the EIT technique whose results are given for several examples.

  • PDF

분사칼럼식 직접접촉 열교환기의 최적 모델링을 위한 연구 (On the Optimum Modelization for a Spray Column Direct Contact Heat Exchanger)

  • 윤석만;강용혁;김종보
    • 설비공학논문집
    • /
    • 제3권1호
    • /
    • pp.1-10
    • /
    • 1991
  • The purpose of this study is to lay groundwork for a complete analysis of two component flow by analyzing a single component flow made of continuous fluid without dispersed phase. In order to achieve uniform velocity distributions which are desirable in designing an optimum spray column direct contact heat exchanger, the influence of injection nozzle orientation has been investigated for axial and radial injections. The results that radial injection ensures more uniform velocity distributions compared to the axial case. The flow characteristics in a spray column have been investigated with various L/D values and inlet velocities, the most uniform internal velocity distributions have been obtained for the case of L/D=10 and 0.1m/sec. In the present investigation, it is shown that radial injection method for the continuous flow is advantageous in obtaining desirable uniform velocity distributions in a spray column. It is also found that as the value of L/D increases and the inlet velocity decreases, the flow improves to be better uniform velocity distributions.

  • PDF