• Title/Summary/Keyword: Direct Sun

Search Result 1,459, Processing Time 0.029 seconds

Theoretical analysis of power requirement of a four-row tractor-mounted radish collector

  • Khine Myat Swe;Mohammod Ali;Milon Chowdhury;Md Nasim Reza;Md Ashrafuzzaman Gulandaz;Sang-Hee Lee;Sun-Ok Chung;Soon Jung Hong
    • Korean Journal of Agricultural Science
    • /
    • v.49 no.4
    • /
    • pp.729-748
    • /
    • 2022
  • Development of radish collectors may enhance radish production and promote upland crop mechanization in the Republic of Korea. Theoretical analysis of power is crucial to ensure the optimum design of agricultural machinery. The aim of the present study is to analyze theoretically the power requirement of a tractor-mounted radish collector under development and to propose design guidelines. The important components of the radish collector were belt-type conveyors, three hydraulic motors, and a direct current (DC) winch motor to operate the total radish collecting process. Theoretical equations were used to calculate the hydraulic motor's power, winch motor power, and draft power at loaded and unloaded conditions. A variety of tractors (44 - 74 kW) and different soil characteristics (hard, firm, tilted, and sandy) were considered to investigate the appropriate drawbar power. Variations of the power requirement of the tractor-mounted radish collector were observed due to modifications of the design parameters. The required hydraulic power of the stem cutting conveyor, stem cutting blade, and transfer conveyor of the radish collector were 0.23 and 0.24, 0.18 and 0.19, and 0.19 and 0.22 kW under unloaded and loaded conditions, respectively. The maximum draft power was calculated as 0.89, 1.07, 1.25, and 1.61 kW at a 30° tilted angle for hard, firm, tilted, and sandy soil, respectively. The calculation showed 2.07 kW DC power was required for unfolding or folding the stem-cutting conveyor. A maximum power of 4.78 kW was prescribed for conducting the whole process of the tractor-mounted radish collector. The analysis of power introduced in this study will be helpful to select the appropriate design parameters for the successful development of a tractor-mounted radish collector.

Cupping Therapy for the Treatment of Migraine Headache: a systematic review and meta-analysis of clinical trials

  • Bushra Mohandes;Fatma Elsayed Ahmed Bayoumi;Aisha Abdulkarim AllahDiwaya;Maryam Salah Falah;Leen Hesham Alhamd;Razan Abid Alsawadi;Yipeng Sun;Aidi Ma;Idris Sula;Muhammad Candragupta Jihwaprani
    • Journal of Pharmacopuncture
    • /
    • v.27 no.3
    • /
    • pp.177-189
    • /
    • 2024
  • Objectives: Cupping therapy is a widely used complementary medicine for the treatment of migraine headaches globally. However, conflicting evidence exists on its effectiveness. To evaluate the safety and efficacy of cupping therapy in treating migraine headache disorder. Methods: Seven databases were systematically searched: PubMed/MEDLINE, Clinicaltrials.gov, Cochrane CENTRAL, ScienceDirect, ProQuest, SinoMed, and the National Science and Technology Library. The primary endpoints are the treatment success and the pain intensity reduction. The secondary endpoints were adverse events (AEs) risk and improvement in quality of life (QoL), which was based on the Migraine Disability Scale (MIDAS). Subgroup analyses were performed based on the cupping techniques (wet and dry cupping) and adjunctive complementary treatments (i.e. acupuncture and/or collateral pricking). Results: Eighteen trials out of 348 records were included, pooling 1,446 participants (n = 797 received cupping therapy). Treatment success was significantly higher among those with cupping therapy (risk ratio [RR] [95% CI] = 1.83 [1.52-2.21]); with significant improvement observed only with wet cupping (RR [95% CI] = 1.88 [1.53-2.30]). The adjunctive complementary therapy did not achieve a greater amplitude of treatment success compared to cupping therapy alone. Furthermore, cupping therapy showed significant pain reduction compared to baseline (standardized mean difference [SMD] [95% CI] = 0.55 [0.39-0.70]) and achieved fewer risks of AEs (RR [95% CI] = 1.88 [1.53-2.30]). However, cupping did not improve the overall QoL (MIDAS SMD [95% CI] = -0.79 [-3.55-1.98]). Conclusion: Cupping therapy was an effective complementary modality to treat migraine headaches. However, it did not demonstrate improvement in QoL (PROSPERO: CRD42024514509).

A Study on The Status of Health Examination and Health Management of Industrial Companies in the Taegu and Kyungbook Areas (일부 경북지역 산업장의 제특성에 따른 건강진단과 보건관리 실태)

  • Kim, Sang-Soon;Kim, Jung-Nam;Park, Jung;Kim, Ok-Ran;Cha, Kyung-Mi;Kwak, Ou-Ke;Park, Kyung-Min;Choi, Yoon-Hee;Bak, Kyung-Shin
    • Research in Community and Public Health Nursing
    • /
    • v.4 no.1
    • /
    • pp.67-76
    • /
    • 1993
  • The purpose of this study was to find the status of health examination and health management of industrial companies located in Taegu and Kyung book areas. It will provide basic information for the provision of effective health management of industrial workers. 49 companies were selected as a study sample group, and data was collected by using a structured Questionnaire which was developed by the members of the Community Health Nursing Academy of Korean Nursing. The health managers of the companies filled out the Questionnaire. The data was gathered from Dec 20, 1992 to Jan 20. The results of the study was as follows : 1. The Study sample showed 85.7% manufacturing companies having 300 or more workers. 2. All the companies had health managers, and companies which had 1,000 or more workers had industrial physicians and nurses. Only 12.2% of the industrial physicians were full time employees, and almost all industrial nurses were full time employees. Except for industrial physicians and nurses, the proportion of hygienists (6.1%), nurses aids (4.1%), and environmental engineers (22.4%) with full time employment statuss was very low. The mean age of industrial physicians was 49.2 while that of industrial nurses was 27.2. The length of work experiences currently ranges for 1 to 3 years for all health workers: physicians, nurses, hygienists, and environmental engineers. 3. Health examination and follow up care 94.31% took general health examinations. Of those, the proportion of the workers, who were determined as C grade(in need of close examination) was 43.86%. The proportion of the workers who were determined as D grade was 22.19%. 13.28% of the workers evaluated at the D grade were taken as a gauge for temporary leave from work. While 8.7% and .09% of them were taken as gauge for a change in job, and or shortening work hours respectively. The proportion of workers who must have taken special examination was 65.04% and of those the proportion of the workers who actually took, the examination was 98.55%. 75% of the workers who were recommended for follow up care were given follow up care. The special examinations were done the most frequently to detect the effects of physical agents (59.2%). Direct notice to individual workers was used the most frequently as a method of notification after a special examination (61.2%). The length of time taken to receive the result of a special examination was less than 1 month (38.9%) and 36.7% had taken up to two months (36.7%.). Most results of special examination were obtained within 2 months. The referral rate of consulting special examination by health managers was estimated at 95.9%. 4. 89.8% of the companies had. their own company dispensaries and 75.5% of those. had separate dispensaries. 32.7% of the companies designated local clinics for health management of workers. Industrial nurses performed health examination the most frequently(1.4 points). Health appraisal for work places were. done the least(0.83 points).

  • PDF

Total Arterial Revascularization Using Y-composite Graft for Isolated Left Main Coronary Artery Disease (단독 좌주간 관동맥 협착병변에서 Y-도관을 이용한 완전 동맥도관 관상동맥우회로 조성술)

  • Ahn, Byong-Hee;Yu, Ung;Chun, Joon-Kyung;Ryu, Sang-Wan;Choi, Yong-Sun;Kim, Byong-Pyo;Hong, Sung-Bum;Bum, Min-Sun;Na, Kook-Ju;Jung, Myung-Ho;Kim, Sang-Hyung
    • Journal of Chest Surgery
    • /
    • v.37 no.1
    • /
    • pp.35-42
    • /
    • 2004
  • Background: For the treatment of isolated left main coronary artery disease, twelve arterial revascularizations with Y-composite grafts using left internal thoracic artery and radial artery or right gastroepiploic artery were peformed. This study was performed to investigate whether V-composite graft can satisfy the blood flow required to make myocardium act properly or not. Borderline stenotic lesions on the left main coronary artery, which are very prone to remodel the bypassed vessels due to competitive flows, were also considered. Material and Method: Among 247 patients who underwent coronary artery bypass grafting from March 2000 to April 2003, 12 patients (4.7%) who had received total arterial revascularizations for the isolated left main coronary artery disease were studied retrospectively. Result: left anterior descending arteries were bypassed with left internal thoracic artery by off-pump technique in all patients, however, 2 cases of left obtuse marginal branches were bypassed under on-pump beating heart. Except for one patient, who did not have an obtuse marginal branch more than 1 mm in diameter, 11 patients had gone through complete arterial revascularizations by use of the Y shape arterial graft. Among five patients who had less than 75% stenosis, one patient showed string sign on left internal thoracic artery grafted to left anterior descending artery. However, two grafts to obtuse marginal blanches were completely obstructed and one showed slender sign. There were no graft-dominant flow in patients with stenotic lesion less than 75%. On the contrary to the result of patients with stenotic lesions less than 75%, all the patients with stenotic lesions more than 90% showed graft-dominant blood flow. Conclusion: In conclusion, it is assumed that, when stenotic lesions are over 90%, coronary artery bypass grafting with an Y shape arterial graft could possibly give enough help to the obstructed coronary arteries in blood supplying to myocardium, which needs massive quantity of blood to act well. However, when patients have borderline stenoses, through scrupulous examinations, more prudent and flexible decisions are required in choosing the treatment methods, such as, direct anastomosis of vein or artery to aorta, or adding supplementary treatment methods like percutaneous coronary intervention, rather than choosing a fixed treatment methods.

Detection of Point Mutations in the rpoB Gene Related to Drug Susceptibility in Mycobacterium Tuberculosis using an Oligonucleotide Chip (올리고뉴클레오티드 칩(Oligonucleotide Chip)을 이용한 항결핵제 감수성과 관련된 Mycobacterium tuberculosis rpoB 유전자의 점돌연변이 판별 방법)

  • Kim, Hyun-Jung;Kim, Seong-Keun;Shim, Tae-Sun;Park, Yong-Doo;Park, Mi-Sun
    • Tuberculosis and Respiratory Diseases
    • /
    • v.50 no.1
    • /
    • pp.29-41
    • /
    • 2001
  • Background : The appearance of multiple-drug-resistant Mycobacterium tuberculosis strains has been seriously compromising successful control of tuberculosis. Rifampin-resistance, caused by mutations in the rpoB gene, can be indicative of multiple-drug-resistance, and its detection is of great importance. The present study aimed to develop an oligonucleotide chip for accurate and convenient screening of drug-resistance. Methods : In order to detect point mutations in the rpoB gene, an oligonucleotide chip was prepared by immobilizing specific probe DNA to a microscopic slide glass by a chemical reaction. The probe DNA that was selected from the 81 bp core region of the rpoB gene was designed to have mutation sites at the center. A total of 17 mutant probes related to rifampin-resistance including 8 rifabutin-sensitive mutant probes were used in this study. For accurate determination, wild type probes were prepared for each mutation position with an equal length, which enabled a direct comparison of the hybridization intensities between the mutant and wild type. Results : Mycobacterial genomic DNA from clinical samples was tested with the oligonucleotide chip and the results were compared with those of the drug-susceptibility test in addition to sequencing and INNO-LiPA Rif. TB kit test in some cases. Out of 15 samples, the oligonucleotide chip results of 13 samples showed good agreement with the rifabutin-sensitivity results. The two samples with conflicting result also showed a discrepancy between the other tests, suggesting such possibilities as existence of mixed strains and difference in drug-sensitivity. Further verification of these samples in addition to more case studies are required before the final evaluation of the oligonucleotide chip can be made. Conlcusion : An oligonucleotide chip was developed for the detection of rpoB gene mutations related to drugsusceptibility. The results to date show the potential for using the oligonucleotide chip for accurate and convenient screening of drug-resistance to provide useful information in antituberculosis drug therapy.

  • PDF

Early and Mid-term Results of Operation for Infective Endocarditis on Mitral Valve (감염성 승모판 심내막염의 중단기 수술 성적)

  • Ahn, Byong-Hee;Chun, Joon-Kyung;Yu, Ung;Ryu, Sang-Wan;Choi, Yong-Sun;Kim, Byong-Pyo;Hong, Sung-Bum;Bum, Min-Sun;Na, Kook-Ju;Park, Jong-Chun;Kim, Sang-Hyung
    • Journal of Chest Surgery
    • /
    • v.37 no.1
    • /
    • pp.27-34
    • /
    • 2004
  • Background: Infective endocarditis shows higher operative morbidity and mortality rates than other cardiac diseases. The vast majority of studies on infective endocarditis have been made on aortic endocarditis, with little attention having been paid to infective endocarditis on the mitral valve. This study attempts to investigate the clinical aspects and operative results of infective endocarditis on the mitral valve. Meterial and Method: The subjects of this study consist of 23 patients who underwent operations for infective endocariditis on the mitral valve from June 1995 to May 2003. Among them, 2 patients suffered from prosthetic valvular endocarditis and the other 21 from native valvular endocarditis. The subjects were evenly distributed age-wise with an average age of 44.8$\pm$15.7 (11∼66) years. Emergency operations were performed on seventeen patients (73.9%) due to large vegetation or instable hemodynamic status. In preoperative examinations, twelve patients exhibited congestive heart failure, four patients renal failure, two patients spleen and renal infarction, and two patients temporary neurological defects, while one patient had a brain abscess. Based on the NYHA functional classification, seven patients were determined to be at Grade II, 9 patients at Grade III, and 6 patients at Grade IV. Vegetations were detected in 20 patients while mitral regurgitation was dominant in 19 patients with 4 patients showing up as mitral stenosis dominant on the preoperative echocardiogram. Blood cultures for causative organisms were performed on all patients, and positive results were obtained from ten patients, with five cases of Streptococcus viridance, two cases of methicillin-sensitive Staphylococcus aureus, and one case each of Corynebacteriurn, Haemophillis, and Gernella. Operations were decided according to the AA/AHA guidelines (1988). The mean follow-up period was 27.6 $\pm$23.3 (1 ∼ 97) months. Result: Mitral valve replacements were performed on 43 patients, with mechanical valves being used on 9 patients and tissue valves on the other 4. Several kinds of mitral valve repair or mitral valvuloplasty were carried out on the remaining 10 patients. Associated procedures included six aortic valve replacements, two tricuspid annuloplasty, one modified Maze operation, and one direct closure of a ventricular septal defect. Postoperative complications included two cases of bleeding and one case each of mediastinitis, low cardiac output syndrome, and pneumonia. There were no cases of early deaths, or death within 30 days following the operation. No patient died in the hospital or experienced valve related complications. One patient, however, underwent mitral valvuloplasty 3 months after the operation. Another patient died from intra-cranial hemorrhage in the 31st month after the operation. Therefore, the valve-related death rate was 4.3%, and the valve-related complication rate 8.6% on mid-term follow-up. 1, 3-, and 5-year valve- related event free rates were 90.8%, 79.5%, and 79.5%, respectively, while 1, follow-up. 1, 3-, and 5-year valve- related event free rates were 90.8%, 79.5%, and 79.5%, respectively, while 1, 3-, and 5-year survival rates were 100%, 88.8%, and 88.8%, respectively. Conclusion: The findings suggest that a complete removal of infected tissues is essential in the operative treatment of infectious endocarditis of the mitral valve. It is also suggested that when infected tissues are completely removed, neither type of material nor method of operation has a significant effect on the operation result. The postoperative results also suggest the need for a close follow-up observation of the patients suspected of having brain damage, which is caused by preoperative blood contamination or emboli from vegetation, for a possible cerebral vascular injury such as mycotic aneurysm.

The comparison of microtensile bond strength with immediate and delayed dentin sealing (즉시 상아질 봉쇄와 지연 상아질 봉쇄에 따른 상아질 접착의 미세인장 결합강도 비교)

  • Lee, Heung-Bae;Han, Chong-Hyun;Shim, Jun-Sung;Kim, Sun-Jai
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.46 no.4
    • /
    • pp.372-380
    • /
    • 2008
  • Purpose: The purpose of this study was to evaluate the effect of various methods of dentin bonding agent application on microtensile bond strength between dentin and resin, using a 2-step etch-and-rinse dentin bonding agent. Material and methods: Twenty freshly extracted human molars were obtained and divided into 4 groups of 5 teeth. 2-step etch-and-rinse dentin bonding agent was used for all groups. The control specimens were prepared using a direct immediate bonding technique. The delayed dentin sealing (A, C) specimens were prepared using an indirect approach with delayed dentin sealing. For group A, resin was built-up on uncured dentin bonding agent, and for group C, resin was built-up on pre-cured dentin bonding agent. Preparation of the immediate dentin sealing (B) specimens also used an indirect approach with immediate dentin sealing immediately following preparation. All teeth were prepared for a microtensile bond strength test. Specimens were stored in water for 24 hours. Ten beams (1.0 ${\times}$ 1.0 ${\times}$ 11 mm) from each tooth were selected for testing. Bond strength data (MPa) were analyzed with a one-way ANOVA test, and post hoc comparison was done using the Scheffe's test. Results: The mean microtensile bond strengths of control group, B and C (DDS with pre-cure) were not statisticaaly different from each other at 32.7, 33.3, 34.2 MPa. the bond strength for group A (DDS without pre-cure), 19.5 MPa, was statistically different (P < .01) from the other 3 groups. Conclusion: When preparing teeth for indirect bonded restorations, DDS with pre-curing dentin bonding agent and IDS results in the same bond strength between dentin and resin. On the contrast, the bond strength was decreased when DDS without pre-curing dentin bonding agent was used.

Effect of Non-Agricultural Facilities on Water Quality and Contamination in Rural Area (농촌용수 수질관리를 위한 비농업시설의 영향 연구)

  • Lee, Byung-Sun;Um, Jae-Yeon;Kim, Yang-Bin;Woo, Nam-Chil;Nam, Kyoung-Phile;Lee, Jong-Min
    • Journal of Soil and Groundwater Environment
    • /
    • v.14 no.2
    • /
    • pp.1-9
    • /
    • 2009
  • This study was objected to identify the effect on water quality and contamination by non-agricultural facilities in 'A' reservoir watershed located in OO city, Kyounggi-do, Korea. Ground- and stream water samples showed (Na+K)-Cl, Ca(Cl, SO$_4$) and Ca-Cl type in an illegally discharging area of sewage and a densely industrial area indicating water contamination. Stream water of an illegally discharging area of sewage had high COD, T-N and T-P. In this area, direct incoming of sewage into stream water was induced ground water system by well pumping, and it made a progress of ground water contaminations with those components. Groundwater of a densely industrial area showed high concentrations of T-N, NO$_3$N. From a nitrogen isotope analysis, stream water of an illegally discharging area of sewage has ${\delta}^{15}N-NO_3$values of 0.7%0 was strongly affected by nitrogen originated from agrochemicals, and a densely industrial area of 19.7%0 from septic system. Ground- and stream water of a livestock fanning area were contaminated with NH$_3$-N and Mn, which was affected by intensive livestock facilities. SAR-conductivity plot indicates the water does not pose either alkalinity or salinity hazard for irrigation. COD, T-N, T-P, NO$3$-N, NH$_3$N and Mn concentrations from contaminated areas were diminished by mixing with 'A' reservoir water. There were no water contaminations in silver towns, vacationlands around reservoir and golf links. Consequently, it should be made a plan of systematic managements for past and- present possible contaminants and sewage systems in preventing water contamination by non-agricultural facilities.

Small-Scale Pond Effects on Reducing Pollutants Load from a Paddy Field (논의 양분유출 저감을 위한 저류지 효과)

  • Kim, Min-Kyeong;Kwon, Soon-Ik;Jung, Goo-Bok;Hong, Seong-Chang;Chae, Mi-Jin;Yun, Sun-Gang;So, Kyu-Ho
    • Korean Journal of Environmental Agriculture
    • /
    • v.32 no.4
    • /
    • pp.355-358
    • /
    • 2013
  • BACKGROUND: Water-born pollution loads by agricultural non-point source (NPS) pollution are expected to become intensified due to ongoing precipitation change. Therefore, it is essential to develop a best management practice (BMP) that is suitable to agricultural environments in Korea. This study aimed to develop an environmental-friendly BMP to reduce NPS pollution load by agricultural activities. An eco-friendly way, small drainage pond, was suggested in this study to avoid direct drainage of agricultural runoffs and eventually reduce the amount of pollutants discharged into the surrounding aqua-environment. METHODS AND RESULTS: A small pond ($12m^2$) was constructed at the corner of a rice paddy field ($1,715m^2$) located in Suwon, Korea. Water was allowed to drain only via a small drainage pond. Sampling was repeatedly made at two locations, one from an entrance and the other from an exit of a pond, during the rice cultivation period (May to October, 2012). Generally, sampling was made only when runoff water drained through a pond, such as during and/or after rain (irrigation). The water quality analysis showed that all quality parameters (SS, $COD_{Mn}$, T-N, and T-P) were improved as water passed through the pond. The amount of runoff water was reduced by 96~100%. Suspended solids and COD concentrations was reduced by 79.3% and 45.6%, respectively. In case of T-N and T-P concentrations, the reduction rates were 52.2% and 60.5%, respectively and the amount of T-N and T-P were reduced by 16.3~73.0% and 15.4~70.1%, respectively. CONCLUSION(S): Our data implies that agricultural NPS pollution from rice paddy fields can be effectively managed when an appropriate drainage water management practice is imposed. In this paper, it was suggested that an installation of a small drainage pond can be effective to prevent not only the nutrient loss from rice fields but also pollutant discharge to surrounding water environments.

Comparison Study of Water Tension and Content Characteristics in Differently Textured Soils under Automatic Drip Irrigation (자동점적관수에 의한 토성별 수분함량 및 장력 변화특성 비교 연구)

  • Kim, Hak-Jin;Ahn, Sung-Wuk;Han, Kyung-Hwa;Choi, Jin-Yong;Chung, Sun-Ok;Roh, Mi-Young;Hur, Seung-Oh
    • Journal of Bio-Environment Control
    • /
    • v.22 no.4
    • /
    • pp.341-348
    • /
    • 2013
  • Maintenance of adequate soil tension or content during the period of crop growth is necessary to support optimum plant growth and yields. A better understanding of soil tension and content for precision irrigation would allow optimal soil water condition to crops and minimize the adverse effects of water stress on crop growth and development. This research reports on a comparison of soil water tension and content variations in differently textured soils over time under drip irrigation using two different water management methods, i.e. pulse time and required water irrigation methods. The pulse time-based irrigation was performed by turning the solenoid valve on and off for preset times to allow the wetting front to disperse in root zone before additional water was applied. The required water estimation method was a new water control logic designed by Rural Development Administration that applies the amount of water required based on a conversion of the measured water tension into water content. The use of the pulse time irrigation method under drip irrigation at a high tension of -20 kPa and high temperatures over $30^{\circ}C$ was not successful at maintaining moisture tensions within an appropriate range of 5 kPa because the preset irrigation times used for water control could not compensate for the change in evapotranspiration during day and night. The response time and pattern of water contents for all of the tested soils measured with capacitance-based sensor probes were faster and more direct than those of water tensions measured with porous and ceramic cup-based tensiometers when water was applied, indicating water content would be a better control variable for automatic irrigation. The required water estimation-based irrigation method provided relatively stable control of moisture tension, even though somewhat lower tension values were obtained as compared to the target tension of -20 kPa, indicating that growers could expect to be effective in controlling low tensions ranging from -10 to -20 kPa with the required water estimation system.