• Title/Summary/Keyword: Direct Radiography

Search Result 88, Processing Time 0.029 seconds

The Study on Characteristic Composition of As in a-Se with X-ray Detection Sensor using $CaWO_4/a-Se$ (다층구조($CaWO_4/a-Se$) 기반의 X선 검출센서에서 a-Se에 첨가된 As의 특성비 연구)

  • Choe, Jang-Yong;Lee, Dong-Gil;Sin, Jeong-Uk;Kim, Jae-Hyeong;Nam, Sang-Hee;Park, Ji-Koon;Kang, Sang-Sik;Jang, Gi-Won;Lee, Hung-Won
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.11a
    • /
    • pp.432-435
    • /
    • 2002
  • The ultimate study of this research is to improve the properties of digital X-ray receptor based on amorphous selenium. There are being two prominent studying for Digital Radiography. Direct and Indirect method of Digital Radiography are announced for producing high quality digital image. But each two systems have strength and weakness. This is a basic research for developing of Hybrid digital radiography which is a new type X-ray detector. ln this study, we investigated the electrical characteristic of multi-layer$(CaWO_4+a-Se)$ as a photoconductor according to the changing iodine composition ratio. The iodine composition ratio of a-Se compound is classified into 5 different kinds which have 30ppm, 100ppm, 300ppm, 500ppm, 700ppm and were made test sample throught thermo-evaporation. The phosphor layer of $CaWO_4$ was overlapped on a-Se using EFIRON optical adhesives. We measured the dark and photo current about the test sample and compared the electrical characteristic of the net charge and signal-to-noise ratio. Among other things, test sample of compound material of 700ppm iodine showed good characteristic of $2.53nA/cm^2$ dark current and $479nC/cm^2{\cdot}mR$ net charge at $3V/{\mu}m$.

  • PDF

Entrance Surface Dose according to Dose Calculation : Head and Wrist (피폭선량 산출을 통한 피부입사선량 계산: 머리 및 손목을 중심으로)

  • Sung, Ho-Jin;Han, Jae-Bok;Song, Jong-Nam;Choi, Nam-Gil
    • Journal of radiological science and technology
    • /
    • v.39 no.3
    • /
    • pp.305-312
    • /
    • 2016
  • This study were compared with the direct measurement and indirect dose methods through various dose calculation in head and wrist. And, the modified equation was proposed considering equipment type, setting conditions, tube voltage, inherent filter, added filter and its accompanied back scatter factor. As a result, it decreased the error of the direct measurement than the existing dose calculation. Accordingly, diagnostic radiography patient dose comparison would become easier and radiogrphic exposure control and evaluation will become more efficient. The study findings are expected to be useful in patients' effective dose rate evaluation and dose reduction.

The Study on Composition ratio of Iodine in Hybrid X-ray Sensor (혼합형 X선 센서에서 a-Se 의 Iodine 첨가비 연구)

  • Gong, Hyung-Gi;Park, Ji-Koon;Choi, Jang-Yong;Moon, Chi-Wung;Nam, Sang-Hee
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.11a
    • /
    • pp.366-369
    • /
    • 2002
  • At present, the study of direct digital X-ray detector and indirect digital X-ray detector proceed actively. But it needs high thickness and high voltage in selenium for high ionization rate. Therefore, we carried out the study of electric characteristics of a-Se with additive ratio of Iodine in drafting study for developing Hybrid X -ray Sensor for complementing direct digital X -ray detector and indirect digital X-ray detector in this paper. On this, there are formed Amorphous selenium multi-layers by sticking phosphor layer$(Gd_{2}O_{2}S(Eu^{2+}))$ using optical adhesives of EFIRON Co. Amorphous selenium multi-layers having dielectric layer(parylene) has characteristics of low dark-current, high X-ray sensitivity. So we can acquired a enhanced signal to noise ratio. We make Amorphous selenium multi-layers with $30{\mu}m$ thickness on glass.

  • PDF

Assessment of Lumbar Spine Kinematics by Posterior-to-Anterior Mobilization

  • Oh, Kang O;Lee, Sang-Yeol
    • Physical Therapy Rehabilitation Science
    • /
    • v.10 no.4
    • /
    • pp.450-456
    • /
    • 2021
  • Objective: Studies confirming the lumber spine kinematics of direct or indirect segmental mobility under the application of joint mobilization, which induces passive force on the spine, are insufficient.Therefore, this study aims to obtain the underlying clinical data by identifying direct or indirect segmental mobility produced by Maitland's PA mobilization technique. Design: Randomized controlled trial design. Methods: Thirty subjects with no back pain participated in this study. X-ray testing equipment (SIG-40-525, Ecoray Inc., Korea) was used to verify the segmented movement of their lumbar. Joint mobilization was performed by physiotherapists with more than 10 years of experience in prescription therapy, and radiography was performed once without PA joint mobilization and once without the mobilization for comparing the lumbar vertebrae before and after the mobilization. The radiographs taken were analyzed using the picture archiving and communication system (PACS) program to measure the spinal displacement, intervertebral height, intervertebral angle, and lumbar lordosis angle. Results: Significant differences were observed in the lumbar displacement, intervertebral angle, and lumbar lordosis angle in all lumbar vertebrae before and after the mobilization. The intervertebral height indicated significant differences in all ventral vertebrae and only in L3-L4 and L4-L5 in dorsal vertebrae. Conclusions: This study suggests that the segmental mobility produced through indirect approaches plays an important role in inducing therapeutic effects in patients with back pain.

EXPERIMENTAL STUDY OF ALVEOLAR BONE WALL DEFECTS USING DIRECT DIGITAL RADIOGRAPHY (디지털방사선촬영법을 이용한 치조골벽 소실에 관한 실험적 연구)

  • Song Nam-Kyu;Koh Kwang-Joon
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.27 no.2
    • /
    • pp.49-61
    • /
    • 1997
  • The purpose of this study was to compare E-speed film, CDR, and modified CDR images by means of observing some artificial defects of alveolar bone wall in the sound human dried mandibles. High diagnostic accuracy was shown in 1 wall and 4 wall defects by all 5 observers (2 Radiologists, 2 Periodontists, 1 General practitioner), but the diagnosis in 2 wall and 3 wall defects was inaccurate. Modified CDR images had the more diagnostic accuracy than E-speed film and CDR images, but there was no statistical difference among them. Finally, radiologist used modified CDR images more than others and used equalization effect more than the change in contrast and/or brightness.

  • PDF

A Case of Mediastinal Cavernous Hemangioma

  • Lee, Seock-Yeol;Park, Kyung-Bae;Oh, Mee-Hye;Lee, Seung-Jin;Lee, Cheol-Sae
    • Advances in pediatric surgery
    • /
    • v.15 no.2
    • /
    • pp.161-165
    • /
    • 2009
  • We report a case of cavernous hemangioma of the anterior mediastinum that was incidentally detected by chest radiography taken at a routine health check-up. A mass lesion was seen in the anterior mediastinum on computed tomography and magnetic resonance imaging. Direct surgical removal was performed for diagnosis and treatment through right thoracotomy. Histopathology confirmed the mass as a cavernous haemangioma. Post-operative course was uneventful.

  • PDF

Cholelithiasis and Choledolithiasis in a Dog (개의 담석증)

  • 윤정희;허진영;황국진;장동우;이영원;윤화영;권오경;최민철
    • Journal of Veterinary Clinics
    • /
    • v.17 no.1
    • /
    • pp.163-167
    • /
    • 2000
  • Cholelithiasis and choledolithiasis were diagnosed with serum chemistry, abdominal radiography and ultrasonography in a 2.0 kg, 10 year-old Yorkshire Terrier dog showing signs of anorexia, vomiting, iceterus and depression. In serum chemistry, the level of alanine transferase, alkaline phosphatase, aspartate transferase, total bilitrubin and direct bilirubin were elevated. On abdominal radiographs, focal lesions with increased radiopacity were seen in the hepatic region and the size of liver was increased. In ultrasonographic examination, it were seen that distension of gall bladder, hypercehoic change of liver, obstruction of cystic duct by calcult and calculi in the gall bladder. Cholecystectomy was undertaken and there were no complications after the operation.

  • PDF

Time-Phased Implementation of a Large-Scale PACS at Samsung Medical Center

  • Ro, Duk-Woo;Choi, Hyung-Sik;Lim, Jae-Hoon;Kim, Won-Ki
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1994 no.12
    • /
    • pp.26-27
    • /
    • 1994
  • The first step implementation of a hospital-wide Picture Archiving Communications System (PACS) at a newly built hospital Samsung Medical Center (SMC), is described. Current clinical operation encompasses the fiber optics delivery of direct-interfaced magnetic resonance imager (LRI), X-ray computed tomography (CT). digital subtraction angiography (DSA) and computed radiography (CR) digital images via high performance file server to the departments of radiology, neurosurgery, orthopedics surgery, neurology, emergency room and the surgical intensive care unit.

  • PDF

A Case of Pleural Effusion Associated with Acute Hepatits A (A형 간염에 동반된 흉막 삼출 1예)

  • Kim, Dong Il;Park, Jae Ock;Kim, Chang Hwi
    • Pediatric Gastroenterology, Hepatology & Nutrition
    • /
    • v.8 no.2
    • /
    • pp.243-246
    • /
    • 2005
  • Pleural effusion represents a rare complication of acute hepatitis A infection. Twelve year-old girl was admitted with complaints of general weakness, nausea and icteric sclerae. She also complained of right chest pain. Right decubitus view of chest radiograph showed pleural fluid accumulation. Laboratory findings were as follows: AST/ALT 1692/1970 IU/L, total/direct bilirubin 4.48/3.66 mg/dL and HA IgM Ab (+). On the seventh day of hospitalization, her general condition was much improved and chest radiography showed resolved pleural effusion.

  • PDF

Investigation of Radiation Effects on the Signal and Noise Characteristics in Digital Radiography (디지털 래디오그라피의 신호 및 잡음 특성에 대한 방사선 영향에 관한 연구)

  • Kim, Ho-Kyung;Cho, Min-Kook;Graeve, Thorsten
    • Journal of Biomedical Engineering Research
    • /
    • v.28 no.6
    • /
    • pp.756-767
    • /
    • 2007
  • For the combination of phosphor screens having various thicknesses and a photodiode array manufactured by complementary metal-oxide-semiconductor (CMOS) process, we report the observation of image-quality degradation under the irradiation of 45-kVp spectrum x rays. The image quality was assessed in terms of dark pixel signal, dynamic range, modulation-transfer function (MTF), noise-power spectrum (NPS), and detective quantum efficiency (DQE). For the accumulation of the absorbed dose, the radiation-induced increase both in dark signal and noise resulted in the gradual reduction in dynamic range. While the MTF was only slightly affected by the total ionizing dose, the noise power in the case of $Min-R^{TM}$ screen, which is the thinnest one among the considered screens in this study, became larger as the total dose was increased. This is caused by incomplete correction of the dark current fixed-pattern noise. In addition, the increase tendency in NPS was independent of the spatial frequency. For the cascaded model analysis, the additional noise source is from direct absorption of x-ray photons. The change in NPS with respect to the total dose degrades the DQE. However, with carefully updated and applied correction, we can overcome the detrimental effects of increased dark current on NPS and DQE. This study gives an initial motivation that the periodic monitoring of the image-quality degradation is an important issue for the long-term and healthy use of digital x-ray imaging detectors.