• Title/Summary/Keyword: Direct Power Control

Search Result 743, Processing Time 0.024 seconds

A Study on Induction Motor Drives by the Direct Torque Control Technique (직접토크 제어방식을 이용한 유도전동기 구동에 관한 연구)

  • 안용상;김연충;이정호;원충연;송호범
    • Proceedings of the KIPE Conference
    • /
    • 1999.07a
    • /
    • pp.394-398
    • /
    • 1999
  • Direct Torque Control method for an Induction Motor is presented which is quite different from field-oriented control. It carries out a precise and quick control of the stator flux and electromagnetic torque of an IM without calling for coordinate transformation, speed measurement, and stator current control. In principle, moreover, DTC operation requires only the knowledge of the stator resistance.

  • PDF

A Novel Direct Instantaneous Pressure Control of Hydraulic Pump System with SR Drive

  • Liang, Jianing;Kim, Tae-Hyoung;Lee, Dong-Hee;Ahn, Jin-Woo
    • Proceedings of the KIPE Conference
    • /
    • 2007.07a
    • /
    • pp.208-210
    • /
    • 2007
  • This paper proposes a novel direct instantaneous pressure control(DIPC) of hydraulic pump system with SR drive. And it has very simple control structure, because it doesn’t use any speed and torque control for adjusting pump pressure. The hysteresis band of pressure and proper switching rules can make the actual pump pressure to be constant with fast dynamic response. Therefore, the proposed DIPC method can control of hydraulic pump pressure steadily with fast dynamic response.

  • PDF

Demand Response Impact on Market Operator's Revenue and Load Profile of a Grid Connected with Wind Power Plants

  • Tahmasebi, Mehrdad;Pasupuleti, Jagadeesh
    • Journal of Electrical Engineering and Technology
    • /
    • v.8 no.1
    • /
    • pp.46-52
    • /
    • 2013
  • Economic properties of an integrated wind power plant (WPP) and the demand response (DR) programs in the sample electricity market are studied. Time of use (TOU) and direct load control (DLC) are two of the DR programs that are applied in the system. The influences of these methods and the incentive payments by market operator's (MOs) with variable elasticity are studied. It is observed that DR with TOU and DLC programs together yields better revenue and energy saving for MOs.

Grid Voltage Estimation Method for Modular Plug-in Active Power Decoupling Circuits (모듈형 플러그인 능동전력디커플링 회로를 위한 계통전압 추종 방법)

  • Kim, Dong-Hee;Kim, Jeong-Tae;Park, Sung-Min;Chung, Gyo-Bum
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.26 no.4
    • /
    • pp.294-297
    • /
    • 2021
  • A grid voltage estimation method for modular plug-in active power decoupling (APD) circuits is proposed in this study as direct replacements of electrolytic capacitors. Since modular plug-in APD circuits cannot have additional grid voltage sensors and should be operated independently without information exchange with the front-end converter, it is impossible to obtain the phase information of the grid directly. Therefore, the proposed method uses the second-order harmonic component of the DC-link voltage to estimate the grid voltage necessary to control the APD circuit. By employing the proposed method, the concept of modular plug-in APD circuits can be realized and implemented without direct detection of the grid voltage. The experimental results based on hardware-in-the-loop simulation (HILS) validate the effectiveness of the proposed control method.

A Study on Applying the Direct Control Method for Small Forklift Transmission System (직접 제어 방식을 적용한 소형 지게차 변속 시스템에 관한 연구)

  • Jeong, Y.M.;Lim, K.;Yang, S.Y.
    • Journal of Drive and Control
    • /
    • v.10 no.4
    • /
    • pp.34-40
    • /
    • 2013
  • The transmission control method of small forklift is classified into pilot control method and direct control method. In pilot control method, the hydraulic circuit which consists a lot of components is very complex so the production process is too costly and time consuming. The direct control method contains fewer components that can be configured to simple hydraulic circuit. It has more advantages because the shift sensitivity of transmission is changed easily via the input profile. In this paper, the controller design and the input profile for system are studied to apply to the direct control method. The input profile consists of Fill section, Hold section and Ramp section. The characteristic of each section is obtained through experiment. As the result, the shift sensitivity and starting performance are effected by Fill section and Hold section.

Harmonics Control of Electric Propulsion System using Direct Torque Control (직접벡터제어방식을 사용하는 전기추진시스템의 고조파 제어)

  • Kim, Jong-Su;Oh, Sae-Gin
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.13 no.12
    • /
    • pp.2618-2624
    • /
    • 2009
  • Harmonics (or distortion in wave form) has always existed in electrical power systems. It is harmless as long as its level is not substantial. However, with the recent rapid advancement of power electronics technology, so-called nonlinear loads, such as variable frequency drives for motor power/speed control, are increasingly finding their way to shipboard or offshore applications. In this paper a new approach to direct torque control (DTC) of induction motor drive is presented. In comparison with the conventional DTC methods the inverter switching frequency is constant and is dramatically increased, requiring neither any increase of the sampling frequency, nor any high frequency dither signal. The well-developed space vector modulation technique is applied to inverter control in the proposed DTC-based induction motor drive system, thereby dramatically reducing the current harmonics. As compared to the existing DTC approach with constant inverter switching frequency, the presented new approach does not invoke any concept of deadbeat control, thereby dramatically reducing the computations.

A Frequency-Tracking Method Based on a SOGI-PLL for Wireless Power Transfer Systems to Assure Operation in the Resonant State

  • Tan, Ping-an;He, Haibing;Gao, Xieping
    • Journal of Power Electronics
    • /
    • v.16 no.3
    • /
    • pp.1056-1066
    • /
    • 2016
  • Wireless power transfer (WPT) technology is now recognized as an efficient means of transferring power without physical contact. However, frequency detuning will greatly reduce the transmission power and efficiency of a WPT system. To overcome the difficulties associated with the traditional frequency-tracking methods, this paper proposes a Direct Phase Control (DPC) approach, based on the Second-Order Generalized Integrator Phase-Locked Loop (SOGI-PLL), to provide accurate frequency-tracking for WPT systems. The DPC determines the phase difference between the output voltage and current of the inverter in WPT systems, and the SOGI-PLL provides the phase of the resonant current for dynamically adjusting the output voltage frequency of the inverter. Further, the stability of this control method is analyzed using the linear system theory. The performance of the proposed frequency-tracking method is investigated under various operating conditions. Simulation and experimental results convincingly demonstrate that the proposed technique will track the quasi-resonant frequency automatically, and that the ZVS operation can be achieved.

Improved Direct Torque Control for Sensorless Matrix Converter Drives with Constant Switching Frequency and Torque Ripple Reduction

  • Lee Kyo-Beum;Blaabjerg Frede
    • International Journal of Control, Automation, and Systems
    • /
    • v.4 no.1
    • /
    • pp.113-123
    • /
    • 2006
  • In this paper, an improved direct torque control (DTC) method for sensorless matrix converter drives is proposed which enables to minimize torque ripple, to obtain unity input power factor, and to achieve good sensorless speed-control performance in the low speed operation, while maintaining constant switching frequency and fast torque dynamics. It is possible to combine the advantages of matrix converters with the advantages of the DTC strategy using space vector modulation and a flux deadbeat controller. To overcome the phase current distortion by the non-linearity of a matrix converter drive, the simple non-linearity compensation method using PQR power theory are presented in the proposed scheme. Experimental results are shown to illustrate the feasibility of the proposed strategy.

Optimal Design of the Hoist Hydraulic System Including the Counter Balance Valve and Differential Cylinder Circuit (카운터밸런스밸브와 차동실린더회로를 포함한 호이스트 유압장치의 최적설계)

  • Lee, S.R.
    • Transactions of The Korea Fluid Power Systems Society
    • /
    • v.5 no.1
    • /
    • pp.13-19
    • /
    • 2008
  • The typical hydraulic system of hoist is composed of a hydraulic supply unit, a directional control valve, counter balance valve, and flow control valves. The flow capacity coefficients of flow control valves should be adjusted so that the hoist is operated at moderate speed and the hydraulic energy loss is minimized. However, it is difficult to adjust the flow coefficients of flow control valves by trial and error for optimal operation. Here, the steady state model of the hoist hydraulic system including the differential cylinder circuit is derived and the optimal flow capacity coefficients of flow control valves are obtained using the complex method that is one kind of constrained direct search method.

  • PDF

A development of simulator for satellite power system (인공위성용 전력시스템 시뮬레이텨 개발)

  • 김영태;김희준
    • Journal of the Korean Institute of Telematics and Electronics B
    • /
    • v.33B no.3
    • /
    • pp.193-201
    • /
    • 1996
  • The space power system for communication satellite which employs the direct energy transfer (DET) method consists of solar array, battry, shunt regulator, charger/discharger and power control unit (PCU). In this paper, the development of the DET power system charger/discharger unit and a microprocessor based PCU is developed for simplicity and flexiblity in the modificatin of control algorithm. A 28V bus voltage, 400W power rting power simulator is built and tested to verify the operation of the simulator at each mode and the stability of mode transition is analyzed.

  • PDF