• Title/Summary/Keyword: Direct Normal Insolation

Search Result 19, Processing Time 0.022 seconds

Performance Validation of Five Direct/Diffuse Decomposition Models Using Measured Direct Normal Insolation of Seoul (서울지역 실측일사량을 이용한 일사량 직산분리 모델의 정밀성 검증 연구)

  • Yoon, J.H.
    • Solar Energy
    • /
    • v.20 no.1
    • /
    • pp.45-54
    • /
    • 2000
  • Five direct/diffuse decomposition models were validated using the eight years data set of direct normal beam insolation measured in Seoul. The comparison has been performed In terms of the widely used statistical indicators such as MBE, RMSE, CV(RMSE), t-Statistic and Degree of Agreement. Result indicates that most of the correlations exhibit a tendency to underestimate the direct normal beam insolation except Bouguer's model. Most of big discrepancies between the measured and the predicted values was mainly shown in near the sunrising and the sunset period. Even though the investigated five models showed fairly large disagreement for the measured values by 34%$\sim$48% of CV(RMSE), Udagawa's correlation which includes the effect of solar altitude variation appears to performs always better in every statistical error tests.

  • PDF

A Revaluation of Solar Energy Resources in Korea (국내 태양에너지 자원의 재평가)

  • Jo, D.K.;Chun, I.S.;Jeon, M.S.;Kang, Y.H.;Auh, C.M.
    • Journal of the Korean Solar Energy Society
    • /
    • v.21 no.4
    • /
    • pp.73-83
    • /
    • 2001
  • Since the solar radiation is the main input for sizing any solar system, it will be necessary to understand and evaluate the insolation data. The horizontal global insolation data have been measured since May, 1982 and direct normal solar insolation data since December 1990 at 16 different sites all over the country and considerable effort has been made for constructing a standard value from measured data at each station. In the results, the average global total solar radiation of the nation is $3,055kcal/m^2.day(12.79MJ/m^2.day)$ and the average clear day direct normal solar beam radiation was $4,600kcal/m^2.day(19.26MJ/m^2.day)$, which indicates possible solar energy application of medium and high temperature technologies with high concentration.

  • PDF

A Study on Characteristics of Fluid Flow on Direct Absorption Receiver from Solar Energy (태양(太陽)에너지의 직접흡수식(直接吸收式) 수열판상(受熱板上)의 유체유동특성(流體流動特性)에 관(關)한 연구(硏究))

  • Pak, Ee-Tong
    • Solar Energy
    • /
    • v.4 no.2
    • /
    • pp.13-28
    • /
    • 1984
  • Direct Absorption Receiver and Thermal Storage System is a complex problem. This paper describes only characteristic of fluid flow on the receiver. The fluid thicknesses of Molten Salts (Melting Point : $397^{\circ}C$) flowing on the receiver of modified protopype ($10m{\times}10m$) were calculated theorectically, changing the receiver slope from 60 degree to 85 degree (5 steps). The receiver temperatures were $430^{\circ}C$ at the top part and $950^{\circ}C$ at the low part. The flow thickness of the Molten Salts at the top part of the receiver are around 1.9mm in the case of maximum insolution ($50{\times}10^6$juoule/sec; 58.898kg/sec of flow rate) and 2.0mm at the low part. In the case of 3/10 of maximum insolation (flow rate = 17.669kg/sec) the flow thickness at the top part are around 0.9mm and 0.4mm at the low part, and in the case of 1/10 of maximum insolation (flow rate = 5.889 kg/see) the flow thickness at the top part are around 0.6mm and 0.3mm at the low part. From experimental measurements of a normal fresh water thickness flowing on the model plate ($12.7cm{\times}111.76cm$), around 0.8mm at the top part of the plate and around 0.7mm at the low part were obtained in the case of maximum insolation (flow rate = 0.12496 kg/see). In the case of 3/10 (flow rate = 0.03748 kg/see) and 1/10 (flow rate = 0.012496 kg/see) of maximum insolation, around 0.5mm and 0.4mm at the top part, and around 0.3mm and 0.2mm at the low part were obtained respectively. The reason why the thickness of the Molten Salts increase at the low part of the receiver only in case of maximum insolation is that decreasing rate of the viscosity of the Molten Salts is larger than decreasing rate of the density of the Molten Salts during temperature increase from the top to the low receiver plate and decrease of the fluid velocity in accordance with continuity principle. In all cases without the above maximum insolation, the thickness of the Molten Salts and the fresh water decreased at the low part of the plate because of gravity force effects rather than friction effects and of continuity principle. All simillar flow patterns were obtained through all cases of the insolation making an exception of only maximum insolation.

  • PDF

Revaluation of Solar Radiation Resources in Korea (국내 태양에너지 자원의 재평가)

  • Jo, Dok-Ki;Kang, Yong-Heack
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2006.11a
    • /
    • pp.153-156
    • /
    • 2006
  • The domestic solar radial ion data have been measured at 16 different sites all over the country since the beginning of 1980. It is very important that the fundamental data for the estimation and assessment of local solar radiation can be secured this project. In order to estimate available energy resource from solar radiation, it is necessary to have enough data, more than 30 years In any country. However since we have collected solar radiation(global radial ion including direct normal radiation) data only for 10 years we still need to measure insolation to secure the reliability and standardization of measured local solar radial ion data. In brief, the major activities on this R&D include rout me maintenance of the national network for insolation data measurement, evaluation of the collected data, and reliability enhancement for assessing the quality of solar radiation data as well.

  • PDF

Development of 10 kW Dish-Stirling System for Commercialization and Analysis of Operating Characteristics (10 kW급 접시형 태양열발전시스템 사업모델 개발 및 운전특성 분석)

  • Kim, Jong-Kyu;Lee, Sang-Nam;Kang, Yong-Heack
    • Journal of the Korean Solar Energy Society
    • /
    • v.30 no.6
    • /
    • pp.118-124
    • /
    • 2010
  • In order to develop commercial model of 10kW dish-Stirling solar thermal power system, modification for the exiting facility was taken for a year as a Leading Project in KIER. During the project, solar tracking system, control and monitoring system and high durability reflector were developed and long term operation were performed. The solar tracking system was tested for four months to investigate the degree of precision and adapted to the control system for an actual operation from October in 2009. The sun tracking accuracy of ${\pm}4$ mrad using modified control system was obtained and the system operated successfully during the experimental period. The monitoring system displays engine pressure, electric generation amounts, generator RPM, receiver temperatures, and etc. from Stirling engine and weather data of Direct Normal Irradiation, Horizontal Global Insolation, wind speed & direction, and atmosphere temperature from weather station. According to the operating results in a clear sky day, electric power of 6,890 W was generated at the DNI value of 850 W/$m^2$ and the averaged solar-to-electricity efficiency during a whole day reached to 18.99%. From the overall operating results, linear power generation trend could be observed with increasing DNI value. The solar-to-electricity efficiency achieved to 19% around the DNI value of 700 W/$m^2$ and increased to 20% when the DNI value goes up to 900 W/$m^2$.

Economic Assessment of Solar Thermal Power System (태양열 발전시스템 경제성 분석)

  • Kim, Jin-Soo;Kang, Yong-Heack;Kim, Jong-Kyu
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2008.11a
    • /
    • pp.25-29
    • /
    • 2008
  • Economic assessment of solar thermal power generation systems was carried out by calculating the levelized electricity cost. Four different commercial (or near commercial) solar thermal power systems (parabolic trough system, power tower system with saturated steam, power tower system with molten salts, and dish-stilting system) were considered for assessment. The assessment also included sensitivity analysis covering the effects of system capacity, direct normal insolation, and the system efficiency.

  • PDF

A Study on the Analysis of Solar Radiation Components (일사량의 성분 분석에 관한 연구)

  • Jo, D.K.;Chun, I.S.;Lee, T.K.;Kang, Y.H.;Auh, C.M.
    • Journal of the Korean Solar Energy Society
    • /
    • v.21 no.1
    • /
    • pp.43-49
    • /
    • 2001
  • Informations of the solar radiation component are essential for modeling various solar energy systems. These Informations are particularly used for middle and high temperature applications, those need concentrating direct normal insolation. In order to estimate the performance of concentrating systems, it is necessary to know the intensity of the beam radiation, as only this component can be concentrated. The Korea Institute of Energy Research(KIER) has began collecting solar radiation component data since August, 1996. KIER's component data will be extensively used by concentrating system users or designers as well as by research institutes.

  • PDF

Characteristic of the Radiation Heat Flux Distribution for the KIER Solar Furnace (KIER 태양로의 열유속 분포 특성)

  • Chai, Kwan-Kyo;Lee, Hyun-Jin;Kim, Jong-Kyu;Yoon, Hwan-Ki;Lee, Sang-Nam;Kang, Yong-Heack;Seo, Tae-Beom
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2011.11a
    • /
    • pp.74-79
    • /
    • 2011
  • Concentration characteristics of the KIER solar furnace are analyzed with a heat flux measurement technique. Total heat capacity of 40kW was confirmed within 1.04% average error, and the normalized maximum heat flux of 3,452 $kW/m^2$ was proved. Non-Gaussian flux distribution in the vertical direction implies that reflectors should not be random rather inclined downwards. Moreover, we characterized flux distribution variations with furnace blind opening ratio, distance from the focal plane, and misalignment of the measurement system. Based on the results, the heat flux distribution can be simply estimated once reflectivity and direct normal insolation values are known. This study will be helpful to the design and the performance evaluation of receivers or chemical reactors.

  • PDF

Basic Design and Dynamic Simulation of Large Scale Solar Thermal Power Plant (대규모 태양열발전 기본설계 및 동특성 계산)

  • Kim, Jong-Kyu;Kang, Yong-Heack;Kim, Jin-Soo;Yoon, Hwan-Ki;Yu, Chang-Kyun;Lee, Sang-Nam
    • Journal of the Korean Solar Energy Society
    • /
    • v.27 no.1
    • /
    • pp.55-61
    • /
    • 2007
  • This paper describes the procedure and calculation results of basic design and transient variation of performance of 1 MWe large scale solar thermal power plant (STPP) by using the commercial software of THERMOFLEX and TRNSYS, respectively. In order to simulate the transient variation of STPP, the results of basic design are necessary. The design standard of the STPP is 1 MWe generation with solar only at high DNI condition and then 0.6 MWe output power for 1 hour using stored energy when the DNI becomes lower unable to operate normally. The results of basic design show the important design data of flow rates, water/steam conditions at each equipments and the estimated efficiency of STPP. In addition, dynamic simulation results of STPP are predicted and plotted for one year and three different days weather data of Daejeon.