• 제목/요약/키워드: Direct Measurement

검색결과 1,571건 처리시간 0.025초

회절광학소자 제작을 위한 레이저 직접 노광기의 공정실험 (Parametric Study for a Diffraction Optics Fabrication by Using a Direct Laser Lithographic System)

  • 김영광;이혁교;김영식;이윤우
    • 한국정밀공학회지
    • /
    • 제33권10호
    • /
    • pp.845-850
    • /
    • 2016
  • A direct laser lithography system is widely used to fabricate various types of DOEs (Diffractive Optical Elements) including lenses made as CGH (Computer Generated Hologram). However, a parametric study that uniformly and precisely fabricates the diffractive patterns on a large area (up to $200mm{\times}200mm$) has not yet been reported. In this paper, four parameters (Focal Position Error, Intensity Variation of the Lithographic Beam, Patterning Speed, and Etching Time) were considered for stabilization of the direct laser lithography system, and the experimental results were presented.

조명제어시스템 경제적인 실적확인 기법 연구 (Study on Economical M&V Methoodology for the Lighting Control System)

  • 최경식;한승호
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2009년도 추계학술대회 논문집
    • /
    • pp.163-167
    • /
    • 2009
  • Although the domestic electric power consumption of lighting have shared 20${\sim}$30 % of the national electric power consumption, the spread of lighting control system which can reduce the electric power consumption have been insignificant. The government have set the demonstration project and given the incentive to promote the spread of lighting control system since 2008. The M&V (Measurement and Verification) methodology for lighting control system have not been set yet in our country, but the direct measurement was suggested in US. The direct measurement methodology can increase the accuracy of measurement, but it cost much money to burden a customer. This study have suggested a new M&V methodology which cost low and is simple relatively. I had measured the amount of electric consumption through both the direct measurement and the new M&V program computation, and have analyzed the deviation. The amount of electric consumption measured by the new M&V program computation have agreed with one by the direct measurement within the error range of the instrumentation in case of lab scale test, and the 4${\sim}$8 % deviation have existed in case of field evaluation.

  • PDF

UHF RFID 태그 칩의 임피던스 산출 불확실성 제거를 위한 모델링 방법 (Modelling Method for Removing Measurement Uncertainty in Chip Impedance Characterization of UHF RFID Tag IC)

  • 양진모
    • 한국전자파학회논문지
    • /
    • 제25권12호
    • /
    • pp.1228-1235
    • /
    • 2014
  • UHF RFID 태그를 설계하기 위해서는 태그 칩의 입력 임피던스 값이 필요하다. 입력 임피던스 산출에는 직접측정 방법이 보편적으로 사용되고 있다. 본 연구에서는 이 방법을 사용할 경우, 칩을 측정장치에 연결하기 위해 도입되는 픽스쳐에서 발생되는 문제점을 분석하고, 그 결과를 확인하였다. 이 문제를 근본적으로 피해갈 수 있는 대안으로 모델링 방법을 제안하고, 실험을 통해 타당성과 정확도를 확인하였다.

How Total Quality Management Mediates Antecedent Variables of Employee Performance?

  • KUSTONO, Alwan Sri
    • The Journal of Asian Finance, Economics and Business
    • /
    • 제7권12호
    • /
    • pp.523-534
    • /
    • 2020
  • The research objective was to find out how Total Quality Management (TQM) mediates antecedents of employee performance variables? The research was conducted with a quantitative approach while the research design was cross sectional. The research model was tested using the structural equation modeling approach with partial least square analysis tools to test the influence among research variables. The research sample consisted of 315 respondents who answered a questionnaire in August-September 2019 at manufacturing companies in East Java. The results showed that situational leadership did not affect employee performance, but did affect the successful implementation of TQM. The performance measurement system has no direct effect on employee performance. The performance measurement system has a direct effect on employee performance. Organizational culture has a direct effect on both employee performance and the application of TQM, so that the application of TQM can improve employee performance. TQM implementation variable acts as a mediation between situational leadership and organizational culture on employee performance. The relationship that was originally a direct influence turned into an indirect effect through TQM. The TQM variable is not proven to be an intervening variable between the performance measurement system and employee performance. There is a direct relationship between these two variables.

50-60대 중장년 남성의 상반신 체형 분석 - 사이즈 코리아 제 8차 직접측정자료를 중심으로 - (Analysis of the 50s and 60s Middle-Aged Men's Upper Body Type - Using on the 8th Size Korea's Direct Measurement Data -)

  • 이진희
    • 한국의상디자인학회지
    • /
    • 제25권4호
    • /
    • pp.1-11
    • /
    • 2023
  • The purpose of this study was to characterize the upper body shape of men in their 50s and 60s by analyzing direct measurement data. Sixty one direct measurement items were analyzed. Subjects (n = 752) were classified based on 5 factors into 4 body types. In order to acquire accurate upper body shape information by analyzing body type using the 8th Size Korea direct measurement data, body shapes were classified through factor and cluster analysis. As a result of the comparative analysis of the upper body measurements from the 5th to the 8th Size Korea measurement, it was found that waist circumference item tended to increase significantly from the 5th Size Korea measurements. The upper body type of middle aged males were classified using five factors: the trunk obesity factor, the trunk vertical factor, the width of the back shoulder, the vertical factor behind the back, and the length factor of the upper body. Middle-aged men were classified into four body types through cluster analysis. Type 1 is relatively short with big arms, Type 2 has wide shoulders and thin arms, and in Type 3, the upper body is relatively long. Type 4 is the most obese upper body.

유방이 큰 여성을 위한 브래지어 패턴 설계 -3차원 유방 형상 자료를 중심으로- (Design of Brassiere Pattern for Big Size Breast Women -Based on 3D Breast Scanning Data-)

  • 한초희;이경화
    • 한국의류학회지
    • /
    • 제43권2호
    • /
    • pp.204-214
    • /
    • 2019
  • A CAD program has recently been introduced that can be directly developed into a three-dimensional human body shape and made into a pattern. It is possible to fabricate a bra that reflects the volume and surface area of the breast; however, it still needs to be verified. This study investigates the average size and shape of 20 big-breasted women and designs a brassiere pattern for women with large breasts using a 3D Flattening function of OptiTex PDS v15.6. In addition, the study verifies the reliability of the proposed method compared to a conventional brassiere pattern. The study results are as follows. First, the three dimensional measurement values were smaller than the direct measurement dimensions when the three dimension measurement dimensions of the subjects were compared with the direct measurement dimensions, the replica measurement dimensions and the three dimensional measurement dimensions. Second, the 3D flattening pattern reflects the actual shape, length, and area of the actual breast when comparing a brassiere pattern using a 3D shape and pattern reflecting the direct measurement.

비접촉식 센서를 사용한 형상 측정 연구 (A Study of Form Measurement using Noncontact Sensor)

  • 송정섭;황윤호;배종일;이만형
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 1995년도 추계학술대회 논문집
    • /
    • pp.407-410
    • /
    • 1995
  • Many researches on measurement technology has been made and developed by various methods. Considering the measurement environment with cutting fluid, coolant and the like, contact type measurement methods are mostly used. But contact measurement method has measuring force and so the sensing head becomes worn. By these reasons, we considered sensors not influenced by the former fluid and so can acquire accrate measured values using error compensation due to temperature and vibration. For this purpose, eddy current sensors and Extended kalman Filter Algorithm for processing measured data has been used. In this paper, we present new technology that can be used for measuring workpiece with previous bad environment using direct method and comparison measurement method. We used cylindrical workpieces which were produced by grinding machine for the target.

  • PDF

페이저 측정 시스템의 측정기 최적배치 (Meter Optimal Placement in Measurement System with Phasor Measurement Unit)

  • 김재훈;조기선;김회철;신중린
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 C
    • /
    • pp.1195-1198
    • /
    • 1999
  • This paper presents optimal placement of minimal set of phasor measurement units(PMU's) and observability of measurement system with PMU. By using the incidence matrix symbolic method which directly assigns measurement and pseudo-measurement to incidence matrix, it is much simpler and easier to analyze observability. The optimal PMU set is found through the simulated-annealing(SA) and the direct combinational method. The cooling schedule parameter which is suitable to the property of problem to solve is specified and optimal placement is proven by presented direct combinational method. Search spaces are limited within reasonable feasible solution region to reduce a unnecessary one in the SA implementation based on global search. The proposed method presents to save CPU time and estimate state vectors based on optimal PMU set.

  • PDF

초소형 3축 가속도계를 이용한 수전달 진동 측정에 관한 연구 (Measurement of the hand-transmitted vibration using a miniature 3-axes accelerometer)

  • 송치문;장한기;김승한;채장범
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2003년도 추계학술대회논문집
    • /
    • pp.1043-1047
    • /
    • 2003
  • Most of the measurement and the evaluation of hand-transmitted vibration have been performed by using a small size single axis accelerometer between the handle and the hand palm or a three axis accelerometer attached on an adapter outside the hand(indirect measurement). It is most desirable for the correct evaluation of hand-transmitted vibration form the power tool handle to measure the acceleration between the handle surface and the hand palm in the three axis(direct measurement) as recommended in ISO 5349-1. In the study three axes acceleration measurement device was developed of which the thickness was less than 7mm so that it can be placed between the handle and the palm without any inconvenience during the measurement. To verify the performance of the developed device, measured acceleration by the two methods, direct and indirect, were compared in the study.

  • PDF

전력계통의 페이저 측정기 최적배치 (Optimal Placement of the Phasor Measurement Units in Power System)

  • 김재훈;조기선;김회철;신중린
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제49권7호
    • /
    • pp.313-322
    • /
    • 2000
  • This paper presents optimal placement of minimal set of Phasor Measurement Units (PMU's) and observability analysis of the network with PMU's. In order to find a observable system, a symbolic method which directly assigns an appropriate symbol for measurement or pseudo-measurement to every entry of node-branch incidence matrix is proposed. It is much simpler and easier to analyze the observability of the network with PMU's than the conventional ones. For the optimal PMU placement problem, two approaches which are based on a modified Simulated-Annealing (SA) method and a Direct Combination method are proposed. Some case studies with IEEE sample system are made to show the performance of the proposed methods are almost alike and more effective than the conventional simulated-annealing method. It is also shown that the Direct Combination method is more effective than the modified simulated-annealing one in the sense of computation burden. The results of this study showed also that the accuracy of power system estimation and system observability can be improved the proposed PMU placements.

  • PDF