• 제목/요약/키워드: Direct Loss

검색결과 900건 처리시간 0.025초

레이저 직접묘화기법에 의한 광도파로 제작에 관한 연구 (A Study on Fabrication of Optical Waveguide using Laser Direct Writing Method)

  • 신보성;김정민;김재구;조성학;장원석;양성빈
    • 한국소성가공학회:학술대회논문집
    • /
    • 한국소성가공학회 2003년도 추계학술대회논문집
    • /
    • pp.391-394
    • /
    • 2003
  • Laser direct writing process is developed 3rd harmonic Diode Pumped Solid State Laser with the near visible wavelength of 355 m sensitive polymer is irradiated by UV laser and developed using polymer solvent to obtain quasi-3D. It is important to reduce line width for image mode waveguides, so some investigations will be carried out in various conditions of process parameters such as laser power, writing speed, laser focus and optical properties of polymer. This process could be to fabricate a single mode waveguide without expensive mask projection method. Experimentally, the patterns of trapezoidal shape were manufactured into dimension of 8.4 mm width and 7.5 mm height. Propagation loss of straight waveguide measured 3 dB/cm at 1,550 nm.

  • PDF

비선형 모델기반 SRM의 고효율 직접 순시토크 제어 (A High Efficiency Direct Instantaneous Torque Control of SRM based on the Nonlinear Model)

  • 안진우
    • 전기학회논문지
    • /
    • 제56권6호
    • /
    • pp.1047-1054
    • /
    • 2007
  • This paper presents a high efficiency direct instantaneous torque control (DITC) of Switched Reluctance Motor(SRM) based on the nonlinear model. The DITC method can reduce the high inherent torque ripple of SRM drive system, but drive efficiency is somewhat low due to the high current and switching loss during commutations. In order to reduce a torque ripple, a fast torque reference trajectory is selected at every instantaneous rotor position. Based on the nonlinear model of SRM, the developing torque by one phase is fixed and the other phase is regulated for minimum switchings of phase switch and variation of torque. The switching during commutation can be reduced and fast commutation can be obtained in the proposed method. As a result, drive efficiency could be improved as well as torque ripple reduction. The validity of proposed method is verified by computer simulations and comparative experiments.

A 3~5 GHz UWB Up-Mixer Block Using 0.18-μm CMOS Technology

  • Kim, Chang-Wan
    • Journal of electromagnetic engineering and science
    • /
    • 제8권3호
    • /
    • pp.91-95
    • /
    • 2008
  • This paper presents a direct-conversion I/Q up-mixer block, which supports $3{\sim}5$ GHz ultra-wideband(UWB) applications. It consists of a VI converter, a double-balanced mixer, a RF amplifier, and a differential-to-single signal converter. To achieve wideband characteristics over $3{\sim}5$ GHz frequency range, the double-balanced mixer adopts a shunt-peaking load. The proposed RF amplifier can suppress unwanted common-mode input signals with high linearity. The proposed direct-conversion I/Q up-mixer block is implemented using $0.18-{\mu}m$ CMOS technology. The measured results for three channels show a power gain of $-2{\sim}-9$ dB with a gain flatness of 1dB, a maximum output power level of $-7{\sim}-14.5$ dBm, and a output return loss of more than - 8.8 dB. The current consumption of the fabricated chip is 25.2 mA from a 1.8 V power supply.

촉매량 변화에 따른 직접 메탄올 연료전지의 성능 특성에 관한 연구 (A Study on the Performance Characteristics of Direct Methanol Fuel Cell with Changing of Catalyst Loading)

  • 서상헌;이창식
    • 한국수소및신에너지학회논문집
    • /
    • 제19권6호
    • /
    • pp.467-473
    • /
    • 2008
  • This study is to investigate the influence of catalyst loading quantity on the direct methanol fuel cell (DMFC) performance. In this paper, Pt-Ru and Pt-black loading as the catalyst were varied from 1 to $4mg/cm^2$ at the anode and cathode, respectively. The experiment was conducted with single fuel cell consisted of $5cm^2$ effective electrode area, serpentine type flow pattern and Nafion 117 membrane. Also, AC impedance and methanol crossover current were measured to investigate the performance loss precisely. As a result, the performance of fuel cell was significantly increased with the increase of cathode catalyst loading. However, the performance did not increase further above a certain Pt-Ru catalyst loading as the increase of anode catalyst loading.

Even Harmonic Mixer를 이용한 2.4GHz ISM band용 Direct Conversion방식의 RF Module 설계 및 제작 (Design and Fabrication of Direct Conversion RF Module using Even Harmonic Mixer for 2-4GHz ISM band)

  • 이주갑;윤영섭;최현철
    • 한국전자파학회:학술대회논문집
    • /
    • 한국전자파학회 2001년도 종합학술발표회 논문집 Vol.11 No.1
    • /
    • pp.222-226
    • /
    • 2001
  • In this paper, 2.4GHz RF Module using Even Harmonic Mixer(EHM) was designed and fabricated for Direct conversion(DC) system. By minimizing performance degradation of DC system with DC offset and LO radiation, the capability of minimization and one chip solution in wireless system was proposed. The designed EHM using anti-parallel diode pair represented 9dB conversion loss and about -60dBm 2LO leakage radiation in RF port, and output reflection and reverse transmission characteristic of low noise amplifier was improved. So superior DC offset suppression characteristic is expected. RF Module which consists of EHM, LNA, RF amplifier, Frequency synthesizer and Duplexer was designed and fabricated.

  • PDF

Corrosion of rebar in carbon fiber reinforced polymer bonded reinforced concrete

  • Bahekar, Prasad V.;Gadve, Sangeeta S.
    • Advances in concrete construction
    • /
    • 제8권4호
    • /
    • pp.247-255
    • /
    • 2019
  • Several reinforced concrete structures that get deteriorated by rebar corrosion are retrofitted using Carbon Fiber Reinforced Polymer (CFRP). When rebar comes in direct contact with CFRP, rebar may corrode, as iron is more active than carbon. Progression of corrosion of rebar in strengthened RC structures has been carried out when rebar comes in direct contact with CFRP. The experimentation is carried out in two phases. In phase I, corrosion of bare steel bar is monitored by making its contact with CFRP. In phase II, concrete specimens with surface bonded CFRP were casted and subjected to the realistic exposure conditions keeping direct contact between rebar and CFRP. Progression of corrosion has been monitored by various parameters: Half-cell potential, Tafel extrapolation and Linear Polarisation Resistance. On termination of exposure, to find residual bond stress between rebar and concrete, pull-out test was performed. Rebar in contact with CFRP has shown substantially higher corrosion. The level of corrosion will be more with more area of contact.

직접 토크 제어를 이용한 리럭턴스 동기 전동기의 최대 효율제어 (An Optimal Efficiency Control of Reluctance Synchronous Motor using Direct Torque Control)

  • 박홍일;김남훈;최경호;김동희;김민회
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2002년도 전력전자학술대회 논문집
    • /
    • pp.431-434
    • /
    • 2002
  • This paper presents an implementation of direct torque control(DTC) of Reluctance Synchronous Motor(RSM) with an efficiency optimization using the 32bit DSP TMS320C31. The influence of iron loss can not neglected as high speed and precision torque control of RSM, so the optimal current ration between torque current and exiting current analytically derived to drive RSM at maximum efficiency For RSM, torque dynamics can be maintained even with controlling the flux level because the generated torque is direct]y proportional to the stator current. The experimental results for an RSM are presented to validate the applicability of the proposed method. The developed control system is shown high efficiency features with 1.0Kw RSM having 2.57 ratio of d/q reluctance.

  • PDF

유한요소-전달강성계수법을 이용한 골조 구조물의 과도응답해석 (Transient Response Analysis of Frame Structures Using the Finite Element-transfer Stiffness Coefficient Method (FE-TSCM))

  • 최명수;문덕홍;김성진
    • 한국소음진동공학회논문집
    • /
    • 제12권9호
    • /
    • pp.674-684
    • /
    • 2002
  • In order to decrease remarkably the computation time and storage used in the direct integration method without the loss of accuracy, authors suggest a new transient analysis algorithm. This algorithm is derived from the combination of three techniques, that is, the transfer technique of the transfer stiffness coefficient method, the modeling technique of the finite element method, and the numerical integration technique of the Newmark method. In this paper, the transient analysis algorithm of a frame structure is formulated by the proposed method. The accuracy and computation efficiency of the proposed method are demonstrated through the comparing with the computation results by the direct integration method for three computation models under various excitations.

이동통신 기지국 직접대기냉각용 에어필터의 성능평가실험 (An Experiment on Performance Evaluation of a Direct Ambient Cooling Air Filter for Wireless Telecommunication Base Transceiver Stations)

  • 여국현;유경훈;차호진;김용우;최동규;이홍규
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2006년도 하계학술발표대회 논문집
    • /
    • pp.436-441
    • /
    • 2006
  • In recent European telecommunication base transceiver stations(BTS) a membrane laminated air filter is reported to replace a heat exchanger in order to cool internal digital units of BTS. The concept of using the air filter is for the direct ambient cooling(DAC) of BTSs without heat loss generally found ill the heat exchanger type BTS. In the present study, a performance evaluation experiment was conducted to investigate the pressure drop characteristics with dust loading and the particle collection efficiency of the air filter for the DAC of BTS.

  • PDF

Parent artery occlusion of a giant internal carotid artery pseudoaneurysm-related direct carotid cavernous fistula: A case report

  • Alexander Andreev;Nadia McMillan;Kelli Money;Max Shutran;Christopher Ogilvy
    • Journal of Cerebrovascular and Endovascular Neurosurgery
    • /
    • 제25권3호
    • /
    • pp.306-310
    • /
    • 2023
  • Traumatic internal carotid artery injuries can produce direct carotid-cavernous fistulas as well as giant internal carotid artery pseudoaneurysms. Clinical sequelae can include headaches, cranial nerves palsies, proptosis, chemosis and optic neuropathy with visual loss as the most dangerous complication. Herein, we present a case of one of the largest reported internal carotid artery pseudoaneurysms associated with a direct carotid cavernous fistula. We describe the techniques and pitfalls of treatment with parent vessel occlusion.