• Title/Summary/Keyword: Direct Frequency Analysis

Search Result 667, Processing Time 0.024 seconds

Design and Experiment of an Electromagnetic Vibration Exciter for the Rapping of an Electrostatic Precipitator

  • Kim, Je-Hoon;Kim, Jin-Ho;Jeong, Sang-Hyun;Han, Bang-Woo
    • Journal of Magnetics
    • /
    • v.17 no.1
    • /
    • pp.61-67
    • /
    • 2012
  • The miniaturization of an electrostatic precipitator has become a key element in successfully constructing an efficient electrostatic precipitator because of the limited space allowed for installation in a subway tunnel. Therefore, the miniaturization of the rapping system of the electrostatic precipitator has also become important. This research proposes a resonant-type electromagnetic vibration exciter as a vibrating rapper for an electrostatic precipitator. The compact vibrating rapper removes collected dust from the collecting plates without direct impact on those collecting plates. To characterize the dynamic performance of the electromagnetic vibration exciter, finite element analysis was performed using a commercial electromagnetic analysis program, MAXEWLL. Moreover, we analyzed the resonant frequency of an electrostatic precipitator, to which the electromagnetic vibration exciter was applied, by ANSYS. Also, to measure the acceleration generated by the electromagnetic vibration exciter, we manufactured a prototype of the ESP and electromagnetic vibration exciter and measured its acceleration at the resonant frequency.

Comparisons between Analysis and Experiment for Leakage Flowrate and Stability depending on the Effect of the Height and the Length of Floating Ring Seal (플로팅 링 실의 길이와 높이 효과에 따른 누수 및 안정성에 대한 해석과 실험의 비교)

  • An, Kyoung-Min;Lee, Yong-Bok;Kim, Chang-Ho;Ha, Tae-Woong
    • 유체기계공업학회:학술대회논문집
    • /
    • 2004.12a
    • /
    • pp.329-336
    • /
    • 2004
  • The lock-up position of the floating ring seal affects the leakage flowrate and the stability. And it is changed depending on the operating and geometry condition. In this paper, the leakage flowrate and stability with change of the height and length were investigated by theoretical analysis and experiment. The parameter of the height and length is expressed to the b and L. The decreasing of the b resulted in the increasing of equivalent whirl frequency ratio in the experimental result at the low speed and high pressure not such as theoretical analysis. As the L increased the leakage flowrate decreased and stiffness and direct damping coefficient increased in the experimental result. That was similar to the theoretical analysis.

  • PDF

Seismic Fragility Analysis of NPP Components for High Frequency Ground Motions (고진동수 지진동에 대한 원전 기기의 지진취약도 분석)

  • 최인길;서정문;전영선
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 2003.03a
    • /
    • pp.110-117
    • /
    • 2003
  • The result of recent seismic hazard analysis indicates that the ground motion response spectra for Korean nuclear power plant site have relatively large high frequency acceleration contents. In the ordinary seismic fragility analysis of nuclear power plant structures and equipments, the safety margin of design ground response spectrum is directly used as a response spectrum shape factor. The effects of input response spectrum shape on the floor response spectrum were investigated by performing the direct generation of floor response spectrum from the ground response spectrum. The safety margin included in the design ground response spectrum should be considered as a floor response spectrum shape factor for the seismic fragility analysis of the equipments located in a building.

  • PDF

A study on applying the direct estimation method to determining maximum acceptable weight in symmetric lifting task (직접추정법의 대칭적인 들기 작업의 최대허용하중 결정에의 적용에 관한 연구)

  • 이관석;박희석
    • Journal of the Ergonomics Society of Korea
    • /
    • v.14 no.1
    • /
    • pp.1-7
    • /
    • 1995
  • In this paper, the effectiveness and accuracy of using the direct estimation method were investigated in determining a worker's lifting capacity or the maximum acceptable weight of lifting (MAWOL) of symmetrical fifting tasks in the workplace were investigated. Six lifting tasks involving two vertical fifting start-end points (0-80cm, 47-102cm) and three lifting frequencies (1, 2, and 4 lifts/minute) were studied. Ten young, male subjects performed the six lifting tasks to predict the MAWOL using the psychophysical method and the direct estimation method. The main results indicated that there were no significant differences between the MAWOLs determined by the two methods except for the lifting frequency of 4 lifts/minute. Analysis of variance was performed on the task rating data to check the consistency of the task rating across subjects, which revealed no significant difference.

  • PDF

Comparison of Performance of Brushless DC Drives under Direct Torque Control and PWM Current Control

  • Zhu Z. Q.;Liu Yong;Howe David
    • KIEE International Transaction on Electrical Machinery and Energy Conversion Systems
    • /
    • v.5B no.4
    • /
    • pp.337-342
    • /
    • 2005
  • Direct torque control (DTC) was originally developed for induction machine drives, and, more recently has been applied to permanent magnet brushless AC (BLAC) drives. In this paper, the performance of DTC controlled brushless DC (BLDC) drives is compared with that of PWM current controlled BLDC drives, both with and without current shaping. Both simulation and experimental results are presented, as well as the analysis of the resulting torque waveforms. It is shown that, in addition to exhibiting a fast torque response, a DTC controlled BLDC drive has a significantly lower low-frequency torque ripple than the PWM current controlled BLDC drive without current shaping, and that it is easier to implement than PWM current control with current shaping.

Direct Power Control of PMa-SynRG with Back-to-back PWM Voltage-fed Drive

  • Baek, Jeihoon;Kwak, Sangshin
    • Journal of Electrical Engineering and Technology
    • /
    • v.13 no.2
    • /
    • pp.761-768
    • /
    • 2018
  • In this paper, the performance analysis of a control topology based on the direct output power control (DPC) for robust and inexpensive permanent magnet-assisted synchronous reluctance generator (PMa-SynRG) system is presented. The PMa-SynRG might be coupled to an internal combustion engine running at variable speed. A three-phase PWM rectifier rectifies the generator output and supplies the dc link. A single-phase PWM inverter supplies constant ac voltage at constant frequency to the grid. The overall control algorithm is implemented on a TMS320F2812 digital signal processor board. Simulations results and experimental results verify the operation of the proposed system.

Fatigue performance evaluation of reinforced concrete element: Efficient numerical and SWOT analysis

  • Saiful Islam, A.B.M.
    • Computers and Concrete
    • /
    • v.30 no.4
    • /
    • pp.277-287
    • /
    • 2022
  • Due to the scarcity of extortionate experimental data, fatigue failure of the reinforced concrete (RC) element might be achieved economically adopting nonlinear finite element (FE) analysis as an alternative approach. However, conventional implicit dynamic analysis is expensive, quasi-static method overlooks interaction effects and inertia, direct cyclic analysis computes stabilized responses. Apart from this, explicit dynamic analysis may provide a numerical operating system for factual long-term responses. The study explores the fatigue behavior based on a simplified explicit dynamic solution employing nonlinear time domain analysis. Among fourteen RC beams, one beam is selected to validate under static loading, one under fatigue with the experimental study and other twelve to check the detail fatigue behavior. The SWOT (Strength, Weakness, Opportunities, Threats) analysis has been carried out to pinpoint the detail scenario in the adoption of numerical approach as an alternative to the experimental study. Excellent agreement of FE and experimental results is seen. The 3D nonlinear RC beam model at service fatigue limits is truthful to be used as an expedient contrivance to envisage the precise fatigue behavior. The simplified analysis approach for RC beam under fatigue offers savings in computation to predict responses providing acceptable accuracy rather than the complicated laboratory investigation. At higher frequency, the flexural failure occurs a bit earlier gradually compared to the repeated loading case of lower frequency. The deflection increases by 6%-10% at the end of first cycle for beams with increasing frequency of cyclic loading. However, at the end of fatigue loading, greater deflection occur earlier for higher load range because of more rapid stiffness degradation. For higher frequency, a slight boost in concrete compressive strains at an initial stage of loading has been seen indicating somewhat stepper increment. Stiffness degradation in larger loading cycle at same duration escalates the upsurge of the rate of strain in case of higher frequency.

Dynamic Stability Analysis of an Axially Accelerating Beam Structure (축 방향 가속을 받는 보 구조물의 동적 안정성 해석)

  • Eun, Sung-Jin;Yoo, Hong-Hee
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2005.05a
    • /
    • pp.877-882
    • /
    • 2005
  • Dynamic stability of an axially accelerating beam stucture is investigated in this paper. The equations of motion of a fixed-free beam are derived using the hybrid deformation variable method and the assumed mode method. Unstable regions due to periodical acceleration are obtained by using the Floquet's theory. Stability diagrams are presented to illustrate the influence of the dimensionless acceleration, amplitude, and frequency. Also, buckling occurs when the acceleration exceeds a certain value. It is found that relatively targe unstable regions exist around the first bending natural frequency, twice the first bending natural frequency, and twice the second bending natural frequency. The validity of the stability diagram is confirmed by direct numerical integration of the equations of motion.

  • PDF

Design of a Digital PWM Controller for a Soft Switching SEPIC Converter

  • Nashed, Maged N.F.
    • Journal of Power Electronics
    • /
    • v.4 no.3
    • /
    • pp.152-160
    • /
    • 2004
  • This paper presents analysis, modeling, and design of a low-harmonic, isolated, active-clamped SEPIC for future avionics applications. Simpler converter dynamics, high switching frequency, zero voltage-Transition-PWM switching, and a single-layer transformer construction result. This paper describes complete design of a digital controller for a high-frequency switching power supply. Guidelines for the minimum required resolution of the analog-to-digital converter, the pulse-width modulator, and the fixed-point computational unit is derived. A design example based on a SEPIC converter operating at the high switching frequency is presented. The controller design is based on direct digital design approach and standard root-locus techniques.

Dynamic Stability Analysis of an Axially Accelerating Beam Structure (축 방향 가속을 받는 보 구조물의 동적 안정성 해석)

  • Eun, Sung-Jin;Yoo, Hong-Hee
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.15 no.9 s.102
    • /
    • pp.1053-1059
    • /
    • 2005
  • Dynamic stability of an axially accelerating beam structure is investigated in this paper. The equations of motion of a fixed-free beam are derived using the hybrid deformation variable method and the assumed mode method. Unstable regions due to periodical acceleration are obtained by using the Floquet's theory. Stability diagrams are presented to illustrate the influence of the dimensionless acceleration, amplitude, and frequency. Also, buckling occurs when the acceleration exceeds a certain value. It is found that relatively large unstable regions exist around the first bending natural frequency, twice the first bending natural frequency, and twice the second bending natural frequency. The validity of the stability diagram is confirmed by direct numerical integration of the equations of motion.