• Title/Summary/Keyword: Direct Current (DC)

Search Result 435, Processing Time 0.03 seconds

Microstructural evolution of tantalum nitride thin films synthesized by inductively coupled plasma sputtering

  • Sung-Il Baik;Young-Woon Kim
    • Applied Microscopy
    • /
    • v.50
    • /
    • pp.7.1-7.10
    • /
    • 2020
  • Tantalum nitride (TaNx) thin films were grown utilizing an inductively coupled plasma (ICP) assisted direct current (DC) sputtering, and 20-100% improved microhardness values were obtained. The detailed microstructural changes of the TaNx films were characterized utilizing transmission electron microscopy (TEM), as a function of nitrogen gas fraction and ICP power. As nitrogen gas fraction increases from 0.05 to 0.15, the TaNx phase evolves from body-centered-cubic (b.c.c.) TaN0.1, to face-centered-cubic (f.c.c.) δ-TaN, to hexagonal-close-packing (h.c.p.) ε-TaN phase. By increasing ICP power from 100 W to 400 W, the f.c.c. δ- TaN phase becomes the main phase in all nitrogen fractions investigated. The higher ICP power enhances the mobility of Ta and N ions, which stabilizes the δ-TaN phase like a high-temperature regime and removes the micro-voids between the columnar grains in the TaNx film. The dense δ-TaN structure with reduced columnar grains and micro-voids increases the strength of the TaNx film.

Non-invasive Brain Stimulation and its Legal Regulation - Devices using Techniques of TMS and tDCS - (비침습적 뇌자극기술과 법적 규제 - TMS와 tDCS기술을 이용한 기기를 중심으로 -)

  • Choi, Min-Young
    • The Korean Society of Law and Medicine
    • /
    • v.21 no.2
    • /
    • pp.209-244
    • /
    • 2020
  • TMS and tDCS are non-invasive devices that treat the diseases of patients or individual users, and manage or improve their health by applying stimulation to a brain through magnetism and electricity. The effect and safety of these devices have proved to be valid in several diseases, but research in this area is still much going on. Despite increasing cases of their application, legislations directly regulating TMS and tDCS are hard to find. Legal regulation regarding TMS and tDCS in the United States, Germany and Japan reveals that while TMS has been approved as a medical device with a moderate risk, tDCS has not yet earned approval as a medical device. However, the recent FDA guidance, European MDR changes, recalls in the US, and relevant legal provisions of Germany and Japan, as well as recommendations from expert groups all show signs of tDCS growing closer to getting approved as a medical device. Of course, safety and efficacy of tDCS can still be regulated as a general product instead of as a medical device. Considering multiple potential impacts on a human brain, however, the need for independent regulation is urgent. South Korea also lacks legal provisions explicitly regulating TMS and tDCS, but they fall into the category of the grade 3 medical devices according to the notifications of the Korean Ministry of Food and Drug Safety. And safety and efficacy of TMS are to be evaluated in compliance with the US FDA guidance. But no specific guidelines exist for tDCS yet. Given that tDCS devices are used in some hospitals in reality, and also at home by individual buyers, such a regulatory gap must quickly be addressed. In a longer term, legal system needs to be in place capable of independently regulating non-invasive brain stimulating devices.

The Development of the ±80kV 60MW HVDC System in Korea

  • Park, Kyoung-Ho;Baek, Seung-Taek;Chung, Yong-Ho;Jang, Gil-Soo
    • Journal of Electrical Engineering and Technology
    • /
    • v.12 no.2
    • /
    • pp.594-600
    • /
    • 2017
  • HVDC transmission systems can be configured in many ways to take into account cost, flexibility and operational requirements. [1] For long-distance transmission, HVDC systems may be less expensive and suffer lower electrical losses. For underwater power cables, HVDC avoids the heavy currents required to charge and discharge the cable capacitance of each cycle. For shorter distances, the higher cost of DC conversion equipment compared to an AC system may still be warranted, due to other benefits of direct current links. HVDC allows power transmission between unsynchronized AC transmission systems. Since the power flow through an HVDC link can be controlled independently of the phase angle between the source and the load, it can stabilize a network against disturbances due to rapid changes in power. HVDC also allows the transfer of power between grid systems running at different frequencies, such as 50 Hz and 60 Hz. This improves the stability and economy of each grid, by allowing the exchange of power between incompatible networks. This paper proposed to establish Korean HVDC technology through a cooperative agreement between KEPCO and LSIS in 2010. During the first stage (2012), a design of the ${\pm}80kV$ 60MW HVDC bipole system was created by both KEPCO and LSIS. The HVDC system was constructed and an operation test was completed in December 2012. During the second stage, the pole#2 system was fully replaced with components that LSIS had recently developed. LSIS also successfully completed the operation test. (2014.3)

Synthesis and characterization of the two-fold interpenetrated Tb(III)-based metal-organic framework (이중 상호 침투 구조를 갖는 신규 터븀(III) 기반 금속-유기 골격체의 합성 및 특성연구)

  • Song, Jeong Hwa
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.32 no.6
    • /
    • pp.225-230
    • /
    • 2022
  • A new two-fold interpenetrating two-dimensional (2D) Tb(III) metal-organic framework (MOF), [Tb(p-XBP4)2.5(H2O)2]·W(CN)8 (1), was prepared using a p-XBP4 (N,N'-p-phenylenedimethylenbis(pyridin-4-one)), Cs3[W(CN)8], and Tb(NO3)3·6H2O. The single crystal X-ray diffraction indicated that Tb-MOF exhibits a unique two-fold interpenetrating 2-D framework. It was also characterized through Fourier transform infrared spectroscopy (FTIR), and single and powder X-ray diffraction. To probe the molecular magnetic behavior, the magnetic properties of Tb-MOF were investigated by direct-current (DC) and alternating-current (AC) magnetic susceptibilities measurements and discussed.

A Wireless Video Streaming System for TV White Space Applications (TV 유휴대역 응용을 위한 무선 영상전송 시스템)

  • Park, Hyeongyeol;Ko, Inchang;Park, Hyungchul;Shin, Hyunchol
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.26 no.4
    • /
    • pp.381-388
    • /
    • 2015
  • In this paper, a wireless video streaming system is designed and implemented for TV white space applications. It consists of a RF transceiver module, a digital modem, a camera, and a LCD screen. A VGA resolution video is captured by a camera, modulated by modem, and transmitted by RF transceiver module, and finally displayed at a destination 2.6-inch LCD screen. The RF transceiver is based on direct-conversion architecture. Image leakage is improved by low pass filtering LO, which successfully covers the TVWS. Also, DC offset problem is solved by current steering techniques which control common mode level at DAC output node. The output power of the transmitter and the minimum sensitivity of the receiver is +10 dBm and -82 dBm, respectively. The channel bandwidth is tunable among 6, 7 and 8 MHz according to regulations and standards. Digital modem is realized in Kintex-7 FPGA. Data rate is 9 Mbps based on QPSK and 512ch OFDM. A VGA video is successfully streamed through the air by using the developed TV white-space RF communication module.

Development of Passive Millimeter-wave Security Screening System (수동 밀리미터파 보안 검색 시스템 개발)

  • Yoon, Jin-Seob;Jung, Kyung Kwon;Chae, Yeon-Sik
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.53 no.7
    • /
    • pp.138-143
    • /
    • 2016
  • The designed and fabricated millimeter-wave security screening system receives radiation energy from an object and a human body. The imaging system consist of sixteen array antennas, sixteen four-stage LNAs, sixteen detectors, an infrared camera, a CCD camera, reflector, and a focusing lens. This system requires high sensitivity and wide bandwidth to detect the input thermal noise. The LNA module of the system has been measured to have 65.8 dB in average linear gain and 82 GHz~102 GHz in bandwidth to enhance the sensitivity for thermal noise, and to receive it over a wide bandwidth. The detector is used for direct current (DC) output translation of millimeter-wave signals with a zero bias Schottky diode. The lens and front-end of the millimeter-wave sensor are important in the system to detect the input thermal noise signal. The frequency range in the receiving sensitivity of the detectors was 350 to 400 mV/mW at 0 dBm (1 mW) input power. The developed W-band imaging system is effective for detecting and identifying concealed objects such as metal or plastic.

DC Resistivity Survey Design for Deep Magma in Mt. Baekdu Using Distributed Acquisition System (백두산 심부 마그마 탐사를 위한 분산계측 시스템을 이용한 전기비저항탐사 설계)

  • Lee, Hyosun;Jung, Hyun-Key;Cho, Sung-Ho;Kim, Yesol;Lee, Youn Soo;Min, Dong-Joo
    • Journal of the Korean earth science society
    • /
    • v.40 no.2
    • /
    • pp.177-187
    • /
    • 2019
  • Several volcanic activities have continued in Mt. Baekdu since the Millennium eruption, and these phenomena have increased the need for volcanic activity surveillance. Various geophysical approaches are needed to obtain the depth and size of magma chamber that lie several kilometers below the surface. We examined the applicability of direct-current resistivity survey in this study. In order to explore the deep magma chamber of Mt. Baekdu, which has a spatial limitation due to the borderline, a large-scale survey with a length of tens of kilometers should be conducted. This type of survey requires a distributed measurement system and optimized exploration designs. Therefore, we propose survey designs taking advantage of our developed distributed acquisition system and analyze the applicability using numerical simulation. We confirmed that our designs that use single survey line with offline transmitting points show comparable results to the conventional 3D survey. It is expected that our research result can contribute to the deep geophysical exploration in Mt. Baekdu.

Effect of tDCS on Cognitive Function of Patients With Stroke: A Systematic Review and Meta-Analysis (뇌졸중 후 인지장애에 대한 경두개 직류 자극: 체계적 고찰 및 메타분석)

  • Yang, Min Ah;Won, Kyung-A;Park, Hae Yean;Park, Ji-Hyuk
    • Therapeutic Science for Rehabilitation
    • /
    • v.10 no.2
    • /
    • pp.7-22
    • /
    • 2021
  • Objective : This study aimed to analyze the effect of transcranial direct current stimulation (tDCS) on cognitive function recovery in patients with stroke. Methods : Data published in Korean and foreign academic journals from 2009 to 2019 were searched using the NDSL, RISS, PubMed, and CINAHL databases. A total of 11 experimental research articles were selected based on the inclusion and exclusion criteria. A qualitative assessment was conducted, and a meta-analysis of nine results from seven of the stuides was performed using the Comprehensive Meta-Analysis 3.0 program. Results : Based on the results of the meta-analysis, the attention and memory effect sizes were 0.725 and 0.796, respectively, which were both considered a "medium effect size". Statistically significant changes were observed in both the areas (p<0.05). Conclusion : The results of this study confirmed that tDCS can be useful in the rehabilitation of patients with stroke with limited cognitive function. In addition, the application methods differed, indicating that a formalized tDCS protocol is required.

Effects of Atmospheric Pressure Microwave Plasma on Surface of SUS304 Stainless Steel

  • Shin, H.K.;Kwon, H.C.;Kang, S.K.;Kim, H.Y.;Lee, J.K.
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2012.08a
    • /
    • pp.268-268
    • /
    • 2012
  • Atmospheric pressure microwave induced plasmas are used to excite and ionize chemical species for elemental analysis, for plasma reforming, and for plasma surface treatment. Microwave plasma differs significantly from other plasmas and has several interesting properties. For example, the electron density is higher in microwave plasma than in radio-frequency (RF) or direct current (DC) plasma. Several types of radical species with high density are generated under high electron density, so the reactivity of microwave plasma is expected to be very high [1]. Therefore, useful applications of atmospheric pressure microwave plasmas are expected. The surface characteristics of SUS304 stainless steel are investigated before and after surface modification by microwave plasma under atmospheric pressure conditions. The plasma device was operated by power sources with microwave frequency. We used a device based on a coaxial transmission line resonator (CTLR). The atmospheric pressure plasma jet (APPJ) in the case of microwave frequency (880 MHz) used Ar as plasma gas [2]. Typical microwave Pw was 3-10 W. To determine the optimal processing conditions, the surface treatment experiments were performed using various values of Pw (3-10 W), treatment time (5-120 s), and ratios of mixture gas (hydrogen peroxide). Torch-to-sample distance was fixed at the plasma edge point. Plasma treatment of a stainless steel plate significantly affected the wettability, contact angle (CA), and free energy (mJ/$m^2$) of the SUS304 surface. CA and ${\gamma}$ were analyzed. The optimal surface modification parameters to modify were a power of 10 W, a treatment time of 45 s, and a hydrogen peroxide content of 0.6 wt% [3]. Under these processing conditions, a CA of just $9.8^{\circ}$ was obtained. As CA decreased, wettability increased; i.e. the surface changed from hydrophobic to hydrophilic. From these results, 10 W power and 45 s treatment time are the best values to minimize CA and maximize ${\gamma}$.

  • PDF

Design and Analysis of Sub-10 nm Junctionless Fin-Shaped Field-Effect Transistors

  • Kim, Sung Yoon;Seo, Jae Hwa;Yoon, Young Jun;Yoo, Gwan Min;Kim, Young Jae;Eun, Hye Rim;Kang, Hye Su;Kim, Jungjoon;Cho, Seongjae;Lee, Jung-Hee;Kang, In Man
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.14 no.5
    • /
    • pp.508-517
    • /
    • 2014
  • We design and analyze the n-channel junctionless fin-shaped field-effect transistor (JL FinFET) with 10-nm gate length and compare its performances with those of the conventional bulk-type fin-shaped FET (conventional bulk FinFET). A three-dimensional (3-D) device simulations were performed to optimize the device design parameters including the width ($W_{fin}$) and height ($H_{fin}$) of the fin as well as the channel doping concentration ($N_{ch}$). Based on the design optimization, the two devices were compared in terms of direct-current (DC) and radio-frequency (RF) characteristics. The results reveal that the JL FinFET has better subthreshold swing, and more effectively suppresses short-channel effects (SCEs) than the conventional bulk FinFET.