• 제목/요약/키워드: Direct Current (DC)

검색결과 435건 처리시간 0.036초

HBT의 전류원 모델을 위한 최적 열 저항값 추출 방법 (Optimal Thermal Resistance Extraction Method for the Current Source Model of HBT)

  • 서영석;김인성;송재성;남효덕
    • 한국전기전자재료학회논문지
    • /
    • 제17권4호
    • /
    • pp.367-372
    • /
    • 2004
  • Two new extraction methods for the thermal Resistance of HBT(Heterojunction Bipolar Transistors) are proposed. First, the analytical expression, based on the thermal characteristics that the base to emitter junction voltage drops with the increase of junction temperature, is derived. Second, the thermal resistance equation that can predict the measured DC(Direct Current) data optimally is derived. These optimal thermal resistance expression is applied to the 2 finger 2${\times}$20${\mu}{\textrm}{m}$-AlGaAs/GaAs HBT and shows the good agreement with the measured data.

고출력 브러시레스 직류전동기 개발에 관한 연구 (A Study on the Development of BLDC Motor with High Power Density)

  • 김현철;공영경;최태인;송종환
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제49권5호
    • /
    • pp.297-304
    • /
    • 2000
  • The motor for torpedo propulsion is needed the compact and short rating high power characteristics. This paper describes the development of the motor through the theory and Finite Element Method(FEM) analysis for Brushless Direct Current Motor(BLDCM) of 7 phase 6 poles. Back EMF, inductance and eddy current loss were analyzed. The proposed methods like magnetic wedge acquired by these FEM analysis were introduced. Phase-leading angle using encoder was used. Test results on the motor of 7 phase 6 poles were showed the validity of proposed methods and phase-leading angle.

  • PDF

HID 램프 디지털 안정기의 제작 (Implementation of a Digital Ballast for HID Lamps)

  • 이치환
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2003년도 학술대회논문집
    • /
    • pp.31-35
    • /
    • 2003
  • This paper presents a microprocessor controlled digital ballast for HID lamps, which gives intelligent features such as a precise power control, optimum ignition voltage and detection of end of life. Average current mode PFC is employed for reducing EMI and a universal input. Direct spread spectrum is done by applying 1 KHz triangular wave for removing acoustic resonance. This frequency modulation of 1 KHz gives also low EMI level and no ripple on lamp current. The microprocessor controls the voltage of DC-bus, the voltage of ignition pulses, the power of output and the bandwidth of spread spectrum. A 250W digital ballast is implemented with an efficiency of 93% and a maximum EMI level of 55 ㏈${\mu}$V.

  • PDF

HVDC 케이블 평가방법 연구 (Study on the Evaluation Methode of HVDC Cable)

  • 안용호;장태인;정길조;유희영;김정년;전승익;한병성
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2005년도 하계학술대회 논문집 Vol.6
    • /
    • pp.229-231
    • /
    • 2005
  • HVDC(High Voltage Direct Current) is an underwater cable between Jeju Island and Haenam in main land and supplies approximately 50% of electrical usage in Jeju Island. If there is any power failure due to HVDC, it will cost approximately 50,000 US dollars per day including Thermal Electrical Generation. Therefore it is absolutely necessary to recover the problem in rapid timely basis. In conclusion, evaluation methode of HVDC cable is needed urgently to upgrade current HVDC underwater cable repair technique in Korea to minimize the cost and time factors.

  • PDF

대형 RSFQ 회로의 구성 (Issues in Building Large RSFQ Circuits)

  • 강준희
    • Progress in Superconductivity
    • /
    • 제3권1호
    • /
    • pp.17-22
    • /
    • 2001
  • Practical implementation of the SFQ technology in most application requires more than single-chip-level circuit complexity. Multiple chips have to be integrated with a technology that is reliable at cryogenic temperatures and supports an inter-chip data transmission speed of tens of GHz. In this work, we have studied two basic issues in building large RSFQ circuits. The first is the reliable inter-chip SFQ pulse transfer technique using Multi-Chip-Module (MCM) technology. By noting that the energy contained in an SFQ pulse is less than an attojoule, it is not very surprising that the direct transmission of a single SFQ pulse through MCM solder bump connectors can be difficult and an innovative technique is needed. The second is the recycling of the bias currents. Since RSFQ circuits are dc current biased the large RSFQ circuits need serial biasing to reduce the total amount of current input to the circuit.

  • PDF

인덕션 방식을 이용한 평면 스테이지의 동특성 개선 (Improvement of Dynamic Characteristic of Large-Areal Planar Stage Using Induction Principle)

  • 정광석;박준규;김효준
    • 제어로봇시스템학회논문지
    • /
    • 제15권7호
    • /
    • pp.675-682
    • /
    • 2009
  • Instead of direct driving like BLDC, the induction principle is adopted as a driving one for planar stage. The stage composed of four linear induction motors put in square type is activated by two-axial forces; low-frequency attractive force and thrust force of the linear induction motors. Here, the modified vector control whose new inputs are q-axis current and dc current biased to three phase current instead of d-axis current or flux current is applied extensively to overall motion of the stage. For the developed system, the precision step test and the constant velocity test are tried to guarantee its feasibility for TFT-LCD pattern inspection. However, to exclude a discontinuity due to phase shift and minimize a force ripple synchronized with the command frequency, the initial system is revised to the antagonistic structure over the full degree of freedom. Concretely describing, the porous air bearings guide an air-gapping of the stage up and down and a pair of liner induction motors instead of single motor are activated in the opposite direction each other. The performances of the above systems are compared from trapezoid tracking test and sinusoidal test.

HVDC 시스템의 SCR 사이리스터 밸브 시험을 위한 Full-Bridge Converter 방식의 개선된 전류원 회로 (Improved Current Source using Full-Bridge Converter Type for Thyristor Valve Test of HVDC System)

  • 정재헌;조한제;구법진;노의철;정용호;백승택
    • 전력전자학회논문지
    • /
    • 제20권4호
    • /
    • pp.363-368
    • /
    • 2015
  • This paper deals with an improved current source using full-bridge converter type for thyristor valve test of HVDC system. The conventional high-current and low-voltage source of synthetic test circuit requires additional auxiliary power supply to provide the reverse voltage for the auxiliary thyristor valve during turn-off process. The proposed circuit diagram to provide the reverse voltage is extremely simple because no additional component is required. The reverse voltage can be obtained from the input DC voltage of the high-current and low-voltage power supply. The operation principle and design method of the proposed system are described. Simulation and experimental results in scaled down STC of 200 V, 30 A demonstrate the validity of the proposed scheme.

영구 자석 스테퍼 모터의 속도 추종과 외란 제거를 위한 비선형 제어기 (Nonlinear Controller for the Velocity Tracking and Rejection of Sinusoidal Disturbances in Permanent Magnet Stepper Motors)

  • 김원희;강동규;한종표;정정주
    • 전기학회논문지
    • /
    • 제60권3호
    • /
    • pp.632-638
    • /
    • 2011
  • In this paper, a nonlinear controller is proposed to track the desired velocity and to cancel sinusoidal disturbances. The proposed method consists of a velocity tracking controller and internal model principles (IMPs). For the design of the velocity tracking controller, mechanical and electrical dynamic controllers are independently designed. For the mechanical dynamics, the velocity tracking controller generates the desired quadrature current to track the desired velocity. The current tracking controller is designed to guarantee the desired quadrature current and to regulate the direct current. Therefore, the proposed velocity tracking controller has a field-oriented control. Since the controllers of the mechanical and electrical dynamics are independently designed, the stability of the closed-loop system is demonstrated using passivity. Since both the cogging torque and DC current errors act as sinusoidal disturbances in PMSM, we use four add-on type IMPs that preserve the merits and performance of the pre-designed controller without sacrificing the closed-loop stability. The performance of the proposed method is validated via simulations.

점화 신호 종류에 따른 PDE 점화회로의 작동 안정성 연구 (Reviewing of Operating Stability about Pulse Detonation Engine's Ignition Circuit to the Type of Power Sources)

  • 김정민;한형석;오세종;최정열
    • 한국추진공학회지
    • /
    • 제22권6호
    • /
    • pp.11-18
    • /
    • 2018
  • 펄스 데토네이션 엔진 (PDE는) 추진기관으로서 의미 있는 추력을 얻기 위해 100 Hz 이상의 높은 작동 주파수를 요구한다. 따라서 PDE는 높은 작동 주파수에서 정확하게 작동하는 점화 회로 필요로 한다. 이번 논문에서는 교류와 직류 전원을 이용하는 두 종류의 점화 회로를 설계하여 비교하였다. 두 회로는 16.66 에서 100.00 Hz 작동 주파수에서 입력 신호와 변압기의 1 차 코일에 인가되는 전압 변화를 측정하여 시험하였다. 실험 결과 직류 전원의 회로의 경우 증가된 작동 주파수에서 최대 5.15%의 작동 주파수 오차를 보였으나 교류 전원의 회로의 경우 33.33 Hz 이상부터는 거의 맞지 않는 결과를 보였다. 이를 통해 고주파 작동의 PDE에서는 직류 전원의 점화 회로가 선호됨을 확인하였다.

경두개직류전류자극 및 시지각 훈련 프로그램 적용이 치매환자의 시지각 기능 및 일상생활활동에 미치는 영향 (Does the Application Transcranial Direct Current Stimulation and Visual Perception Program Enhance the Visual Perception Function and ADL Performance of Dementia Patients)

  • 김고운;김보라;안태규
    • 대한통합의학회지
    • /
    • 제8권4호
    • /
    • pp.213-221
    • /
    • 2020
  • Purpose : This study aimed to evaluate the changes in visual perception and daily life activities after simultaneously applying the visual perception training program and transcranial DC stimulation. Particularly, this study tried to understand what changes in abilities among daily life activities influenced cognition. Methods : This study selected 50 dementia patients to achieve the objective. This study applied transcranial DC stimulation and a visual perception training program to a treatment group (n=25) and a visual perception training program to a control group (n=25). The intervention was applied five times per week and 30 minutes per session (total of 30 intervention sessions). This study measured visual perception functions and daily life activities using MVPT and FIM before and after applying the intervention. Results : The visual perception, mobility of daily life activities, cognition, and total score of the treatment group (n=25), which received the visual perception training program and transcranial DC at the same time, were significantly (p<.05) different between before and after the intervention. Moreover, when the visual perception and daily life activities of the treatment group and those of the control group after implementing the intervention were compared, they were significantly (p<.05) different between the two groups. Conclusion : The results of this study showed that the simultaneous application of the visual perception training program and transcranial DC stimulation was an effective means to enhance the visual perception and daily life activities of dementia patients. The results implied that transcranial DC stimulation, as well as the application of visual perception training program, as well as a visual perception training program, was effective for improving the visual perception functions and daily life activities dementia patients and simultaneous application of the two interventions would increase the effect even further.