• Title/Summary/Keyword: Direct Control

Search Result 4,179, Processing Time 0.045 seconds

A Study on Simulation of Shift Sensitivity of Small Forklift Transmission using Direct Control Method (직접제어 방식을 이용한 소형 지게차 변속감도 시뮬레이션에 관한 연구)

  • Jeong, Y.M.;Yang, S.Y.
    • Journal of Drive and Control
    • /
    • v.11 no.4
    • /
    • pp.8-14
    • /
    • 2014
  • The transmission control method of a small forklift is classified into a pilot control method and a direct control method. In the pilot control method, the complex hydraulic circuit consists of many components, making the production process too costly and time consuming. The direct control method contains fewer components that can be configured to simple hydraulic circuits. As another advantage, the input profile easily changes the shift sensitivity of the transmission. Therefore, this research considers the characteristics of the direct control method in the development of hydraulic system design. This paper will present a simulation of the direct control transmission using AMESim. First, modeling of the direct control method is obtained and simulated with real parameters. The simulation results then are carried out and compared with the experimental results to verify and analyze the characteristics of the direct control method.

A study on the intelligent control of chaotic nonlinear systems using neural networks (신경 회로망을 이용한 혼돈 비선형 시스템의 지능 제어에 관한 연구)

  • 오기훈;주진만;박진배;최윤호
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1996.10b
    • /
    • pp.453-456
    • /
    • 1996
  • In this paper, the direct adaptive control using neural networks is presented for the control of chaotic nonlinear systems. The direct adaptive control method has an advantage that the additional system identification procedure is not necessary. In order to evaluate the performance of our controller design method, two direct adaptive control methods are applied to a Duffing's equation and a Lorenz equation which are continuous-time chaotic systems. Our simulation results show the effectiveness of the controllers.

  • PDF

Predictive Direct Torque Control Algorithm for Induction Motors and its Digital Implementation

  • Mutschler, Peter;Flach, Erich
    • Proceedings of the KIPE Conference
    • /
    • 1998.10a
    • /
    • pp.1-6
    • /
    • 1998
  • To achieve fast control action, direct control methods should be used. "Direct Mean Torque Control" (DMTC) combines the good dynamic performance of Direct Torque Control (DTC) with the advantages of inherently constant switching frequency and time equidistant control for implementation in a digital signal processor. Since DMTC is a predictive control algorithm, the model and its correction deserves special investigations. This paper proposes a steady-state Kalman filter which is well suited for fast computation.mputation.

  • PDF

Seismic test of modal control with direct output feedback for building structures

  • Lu, Lyan-Ywan
    • Structural Engineering and Mechanics
    • /
    • v.12 no.6
    • /
    • pp.633-656
    • /
    • 2001
  • In this paper, modal control with direct output feedback is formulated in a systematic manner for easy implementation. Its application to the seismic protection of structural systems is verified by a shaking table test, which involves a full-scale building model and an active bracing system as the control device. Two modal control cases, namely, one full-state feedback and one direct output feedback control were tested and compared. The experimental result shows that in mitigating the seismic response of building structures, modal control with direct output feedback can be as effective and efficient as that with full-state feedback control. For practical concerns, the control performance of the proposed method in the presence of sensor noise and stiffness modeling error was also investigated. The numerical result shows that although the control force may be increased, the maximum floor displacements of the controlled structure are very insensitive to sensor noise and modeling error.

Predictive Direct Power Control in MMC-HVDC System (MMC-HVDC 시스템의 예측 기반 직접전력제어)

  • Lee, Kui-Jun
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.23 no.6
    • /
    • pp.403-407
    • /
    • 2018
  • This study proposes a predictive direct power control method in a modular multilevel converter (MMC) high-voltage direct-current (HVDC) system. The conventional proportional integral (PI)-based control method uses a cascaded connection and requires an optimal gain selection procedure and additional decoupling scheme. However, the proposed control method has a simple structure for active/reactive power control due to the direct power control scheme and exhibits a fast dynamic response by predicting the future status of system variables and considering time delay. The effectiveness of the proposed method is verified by simulation results.

Control software development for direct drive arm robot using 32bit(MC68020) CPU with WHILE language (WHILE 언어를 사용한 32비트(MC 68020) CPU제어기에 대한 직접구동방식 로보트의 제어소프트웨어 개발)

  • 이주장;신은주;곽윤근
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1989.10a
    • /
    • pp.239-243
    • /
    • 1989
  • This paper represents the control software development for Direct Drive Arm Robot with the WHILE language composed the 68000 assembly language and high level language modula-2. Direct Drive Ann Robot needs the control program which is fast step and exactly position moving because Direct Drive Arm Robt depends on accuracy. We found that the self-tuning algorithm for this robot control is very good for the real time control and the floating point operation using the 32 bit CPU(MC 68020) controller.

  • PDF

Indications and Estimations of the Needs for Direct Medical Control in the Patients Transported by 119 Rescuers (119 구급대에 의해 이송된 환자들 중 직접적 의료지도가 필요한 범위와 그에 따른 수요 추정)

  • Park, Jae-Young;Jung, Koo-Young;Bae, Hyun-A
    • Fire Science and Engineering
    • /
    • v.20 no.3 s.63
    • /
    • pp.42-47
    • /
    • 2006
  • Direct medical control by medical doctors is an essential part of emergency medical services system (EMSS). However, the indications are not specifically defined, even in 119 system with their own medical control team. The Seoul Metropolitan Fire and Disaster Management Department has operated internal medical consultation services on its own since January 2004. Based on the experiences from these services, we reviewed the cases of the direct medical consultation and establish the indications for direct medical control. And we presumed the demand of direct medical control with the established indications. The crews of 119 in Seoul made 793 calls to Medical Control Team during November 2004. We reviewed all of the calls according to the level of consciousness (AVPU), the kinds of emergency care done by crews during transport (10 categories), and the mechanisms of injuries (9 categories). The need for direct medical control was judged by authors with reviewing the records reported by the crews and control teams. Among 23 items, 14 items assigned as the indications, which were abnormal level of consciousness (VPU), 6 kinds of emergency care, and 5 mechanisms of injures. The sum of the three of them, 7,782 cases (45.9%), was in need of direct medical control. In conclusion, about half of the patients transported by 119 crews in Seoul require direct medical control. The need for the direct medical control in Seoul was estimated as many as 260 calls per day. To fulfill the need for direct medical control and to provide a effective medical control, the direct medical control should be accomplished through the communications between the crews and the medical staffs in the local hospitals.

Force control of the direct-drive robot using learning controller (학습제어기를 이용한 직접구동형 로봇의 힘제어)

  • Hwang, Yeong-Yeun
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.21 no.11
    • /
    • pp.1819-1826
    • /
    • 1997
  • Direct-drive robots are suitable to the position and force control with high accuracy, but it is difficult to design a controller because of the system's nonlinearity and link-interactions. This paper is concerned with the study of the force control of direct-drive robots. The proposed algorithm consists of feedback controllers and a neural network. After the completion of learning, the output of feedback controller is nearly equal to zero, and the neural network controller plays an important role in the control system. Therefore, the optimum retuning of parameters of feedback controllers is unnecessary. In other words, the proposed algorithm does not require any knowledge of the controlled system in advance. The effectiveness of the proposed algorithm is demonstrated by the experiment on the force control of the parallelogram link-type direct-drive robot.

Performance Improvement of a Grid-Connected Inverter System using a Sliding-Mode Based Direct Power Control with a Variable Gain (슬라이딩 모드 기반의 가변이득을 가지는 직접전력제어를 이용한 계통연계형 인버터의 성능개선)

  • Lee, Byoung-Seoup;Lee, June-Seok;Lee, Kyo-Beum
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.17 no.1
    • /
    • pp.57-66
    • /
    • 2012
  • This paper proposes a performance improvement of grid-connected inverter system using sliding-mode based direct power control with a variable gain. The proposed control method determine variable gain of PI controller by using modeling at direct power control (DPC) applied to space vector modulation method. Also, this method use sliding-mode control to maintain excellent dynamic response of character of direct power control (DPC). The validity of the proposed algorithm are verified by simulations and experiments.

Direct Thrust Control of Permanent Magnet Type Linear Synchronous Motor by using Digital Signal Processor (DSP를 이용한 영구 자석형 선형 동기전동기의 직접 추력 제어)

  • U, Gyeong-Il;Kim, Deok-Jin;Gwon, Byeong-Il
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.49 no.8
    • /
    • pp.514-521
    • /
    • 2000
  • This paper presents a direct thrust control scheme for permanent magnet linear synchronous motor(PMLSM) by using digital signal processor(DSP). And a simulation method for the direct thrust control of a permanent magnet linear synchronous motor using the equivalent circuit is presented. The detent force that was obtained by cubic spline method is considered in the simulation. Thrust correction coefficient is utilized to estimate actual thrust on the direct thrust control, which considers the longitudinal end effect due to the finite core length of the permanent magnet linear synchronous motor. The motor self inductance, the initial flux linkage by the permanent magnet is calculated in advance by the finite element analysis, and then the direct control simulation is carried out. As the results, thrust, current and speed are shwon.

  • PDF