• Title/Summary/Keyword: Direct/indirect methods

Search Result 769, Processing Time 0.028 seconds

An Ergonomic Analysis on Working Posture Associated with Dental Treatment Using Indirect Viewing Method (간접보기 도구를 이용한 치과 진료 관련 작업자세에 대한 인간공학적 분석)

  • Son, Chang-Won;Choi, Soon-Young;Park, Dong-Hyun
    • Journal of the Korea Safety Management & Science
    • /
    • v.12 no.2
    • /
    • pp.55-64
    • /
    • 2010
  • This study tried to focus on nontraditional job that has not been studied in terms of the subjects associated with MSDs(Musculoskeletal Disorders). Specifically, dental procedure was the job to be analyzed in this study. An alternative method as well as a traditional method for viewing teeth while performing simulated dental procedures. Four graduated students did both methods(direct view and indirect view) as the subjects in this study. The method based on indirect view used a video camera and monitor to view the teeth. The experiment was conducted five times for each subject. The major findings in this study were as follows; 1) Job speed was increased with the repetitions for both methods, 2) Difference of Neck flexion between direct and indirect methods was statistically siginificant(Neck flexion for indirect method was dramatically decreased), 3) Difference of job speed between direct and indirect methods was statistically significant(Job speed for direct method was faster than that of indirect method), 4) Difference of error rate between direct and indirect methods was statistically significant(error rate for direct method was lower than that of indirect method), 5) Even though indirect method did not provide better performance in terms of job speed and error rate yet, it seemed to need a trade-off between two methods in the future since indirect method provided better working postures than that of direct method.

Accuracy Comparison of Blood Pressure among the Direct Measurement Method and Two Automatic Indirect Measurement Methods in the Patients with Various Blood Pressure (다양한 혈압상태에서 직접혈압을 기준으로 HP 자동혈압기와 국산자동혈압기의 정확도 비교)

  • Song Hyo-Sook;Jun Tae-Gook;Choi Eun-Jung;Kim Mi-Jung
    • Journal of Korean Academy of Fundamentals of Nursing
    • /
    • v.8 no.3
    • /
    • pp.366-378
    • /
    • 2001
  • Objective: The purpose of this study was to identify differences in measurement methods for blood pressure (Direct measurement, HP automatic indirect measurement, and SE 7000 Korean made indirect measurement), and to evaluate the clinical trial of the Korean made automatic indirect blood pressure measurement. Material & Methods: From June, 1999 to February, 2000, fifty five consecutive patients were randomized into hypertension group (n=20), normotension group (n=20), and hypotension group (n= 15). Measuring blood pressure by indirect methods (HP NIBP M 1008B and SE 7000 NIBP Korean made) was done simultaneously in the same arm with arterial line for direct blood pressure measurement (HP M1006A). The procedures were repeated ten times at intervals of 2 minutes. Statistical analysis was Performed using SPSS (version 8.0 for windows) software package. Values were expressed as means and standard deviation and means were compared using t-test. Statistical significance was considered present with a p value less than 0.05. Results: In the hypertension group and noromotension group, the disparity between HP direct measurement and indirect SE 7000 NIBP did not show any differences compared to the disparity between HP direct measurement and indirect HP NIBP. In the hypotension group, the disparity in the diastolic pressure between HP direct measurement and indirect SE 7000 NIBP was significantly different compared to the disparity between HP direct measurement and indirect HP NIBP (p<0.001), however, disparities in systolic pressure did not showed any differences. Conclusion: Direct blood pressure measurement (HP M1006A) can be replaced with indirect blood pressure measurements (HP NIBP M 1008B & SE 7000 NIBP) in normotension and hypertension patients. Korean made indirect measurement was found to be more accurate compared to HP indirect measurement in hypotension Patients, but more study is needed.

  • PDF

Direct and indirect methods for determination of mode I fracture toughness using PFC2D

  • Sarfarazi, Vahab;Haeri, Hadi;Shemirani, Alireza Bagher
    • Computers and Concrete
    • /
    • v.20 no.1
    • /
    • pp.39-47
    • /
    • 2017
  • In this paper, mode I fracture toughness of rock was determined by direct and indirect methods using Particle Flow Code simulation. Direct methods are compaction tension (CT) test and hollow centre cracked quadratic sample (HCCQS). Indirect methods are notched Brazilian disk (NBD) specimen, the semi-circular bend (SCB) specimen, hollow centre cracked disc (HCCD), the single edge-notched round bar in bending (SENRBB) specimen and edge notched disk (END). It was determined that which one of indirect fracture toughness values is close to direct one. For this purpose, initially calibration of PFC was undertaken with respect to data obtained from Brazilian laboratory tests to ensure the conformity of the simulated numerical models response. Furthermore, the simulated models in five introduced indirect tests were cross checked with the results from direct tests. By using numerical testing, the failure process was visually observed. Discrete element simulations demonstrated that the macro fractures in models are caused by microscopic tensile breakages on large numbers of bonded discs. Mode I fracture toughness of rock in direct test was less than other tests results. Fracture toughness resulted from semi-circular bend specimen test was close to direct test results. Therefore semi-circular bend specimen can be a proper test for determination of Mode I fracture toughness of rock in absence of direct test.

Comparison of Ultrasonic Velocities between Direct and Indirect Methods on 30 mm × 30 mm Spruce Lumber

  • OH, Sei Chang
    • Journal of the Korean Wood Science and Technology
    • /
    • v.48 no.4
    • /
    • pp.562-568
    • /
    • 2020
  • This study investigates the relationship between ultrasonic velocity and density in the direct method, the effect of distance between transducers in the indirect method, and the difference between the direct and indirect methods with transducers placed at a distance of 200 mm in nondestructive ultrasonic testing of spruce lumber. The direct method using 54 kHz ultrasonic transducers was applied to two planes, namely, radial section (LR) and tangential section (LT) of samples. The indirect method measurements were taken using the same transducers. Two velocities were measured at the top and bottom of the LT plane and at the two sides of the LR plane; the two values for each plane were averaged. The relationship between density and ultrasound velocity in the direct method demonstrated a positive correlation between the two variables. The difference between the two planes, LT and LR, was not statistically significant. Moreover, the distance between the transducers in the indirect method affected ultrasound velocity, with the ultrasonic velocity increasing as the distance between the transducers became larger. A transducer distance of 200 mm yielded a close approximation of the direct method results with a ratio of 0.87. Finally, no statistical evidence of a difference between the two planes in the indirect method was found. If the direct method, which requires access to two surfaces, is impractical, the indirect method can be applied.

The Impact of Methods of Presenting Cash Flow Statement on Loan Decision: Evidence from Vietnam

  • NGUYEN, Dung Duc
    • The Journal of Asian Finance, Economics and Business
    • /
    • v.7 no.8
    • /
    • pp.87-94
    • /
    • 2020
  • The paper aims to investigate the impact of presenting statements of cash flow using the direct method and the indirect method on loan decision by credit officers at Vietnamese banks. The data was collected from 150 credit officers of commercial banks in Vietnam based on the questionnaire about making loan decision when the cash flow statement is presented in different methods, namely, direct and indirect methods. This research uses T-tests to check whether using the direct or indirect method affects the accurate calculation of loan criteria, affects the loan decision by credit officers, and compare these two methods in the aspects of information provision. The research has pointed out that: 1) the direct method helps the calculation of indicators related to loans more accurately; 2) credit officers say that, while the direct method of presenting cash flow statement provides clearer information, the use of either the direct method or the indirect method does not affect the banks' loan decision. Since then, the author recommends that cash flow statements should be provided with information in a direct method to present the information needed for loan decision more accurately so as to improve the quality of cash flow statement.

Accurate Chiral Discrimination of Acidic- and Amino acidic-Chiral Drugs by Indirect GC and Direct CE Enantiomeric Separation Methods

  • Kim, Kyoung-Rae
    • Proceedings of the PSK Conference
    • /
    • 2002.10a
    • /
    • pp.167-168
    • /
    • 2002
  • Because of the differences between biological and pharmacological properties of chiral drugs in human body, accurate determinations of their optical purities have been in great need. There are two major approaches in chiral separation: indirect method performed under achiral condition, and direct method under the chiral environment. We have been conducting chiral separation of acidic chiral compounds and also amino acidic chiral compounds employing indirect GC methods and direct CE enantiomeric separation methods. (omitted)

  • PDF

A Study on Efficient Management of Bicycle Traffic Flow at Four-Legged Intersections (4지 신호교차로에서 효율적 자전거 교통류 처리방안 연구)

  • Mok, Sueng Joon;Kim, Eung Cheol;Heo, Hee Bum
    • International Journal of Highway Engineering
    • /
    • v.15 no.3
    • /
    • pp.177-189
    • /
    • 2013
  • PURPOSES: This study aims to suggest a proper left-turn treatment method for the bicycle traffic flow at four-legged intersections. METHODS: Four types of crossing methods are proposed and analyzed : (1) indirect left turn, (2) direct left turn, (3) direct left turn on a Bike Box, and (4) direct left turn on bike left turn lane. The VISSIM simulation tests were conducted based on forty-eight operation scenarios prepared by varying vehicle and bicycle traffic volumes. RESULTS : The results from the four-legged signalized intersections suggest that (1) the indirect left turn is appropriate when vehicle demand is high, (2) the direct left turn is efficient on most traffic situation but the safety is a concern, (3) the direct left turn on a Bike Box is appropriate when bicycle demand is high while vehicle demand is not, and (4) the direct left turn on a bike left turn lane is appropriate when both vehicle and bicycle demand are low. CONCLUSIONS : The direct left turn of bicycle provides more efficiency than the indirect left turn at the four-legged intersections but to apply the methods and to study more, advanced evaluation methods, related law, and insurance programs are needed.

A Comparision of a Direct and Three Indirect Methods of Measuring Blood Pressure (직접혈압측정치와 3가지 간접혈압측정치의 비교)

  • Lee Myung-Hwa;Park Hyo-Kyung;Shon Soo-Kyung
    • Journal of Korean Academy of Fundamentals of Nursing
    • /
    • v.5 no.1
    • /
    • pp.95-106
    • /
    • 1998
  • The purpose of this study was to compare direct and three indirect blood pressure measurements in adults and to compare among three indirect blood pressure measurements in adults. One direct(intraarterial) and three indirect(using a mecury sphygmomanometer, a aneroid type sphygmomanometer and an automatic auscultatory device) methods of blood pressure measurement were compared in adult patients who had an arterial line. The subjects for this study consisted of 29 patients in K medical center, B medical center, B hospital and M hospital in Pusan. The data was collected from October 1, 1992 to June 30, 1993. The collected data was analysed with the SPSS program, frequency, percentage, mean, S.D., t-test, ANOVA. The results of this study were as follows : 1) There was a significant difference in the systolic BP when using the direct and three indirect measurements(P<0.05). 2) There was no overall significant difference in the diastolic BP when using the direct and three indirect measurements. 3) There was no significant difference in the SBP and DBP among the three indirect measurements.

  • PDF

Direct and indirect bonding of wire retainers to bovine enamel using three resin systems: shear bond strength comparisons (부착 유지장치의 직, 간접 부착법에 따른 전단 접착력 비교)

  • Kwon, Tae-Yub;Meina, Hu;Antoszewska, Joana;Park, Hyo-Sang
    • The korean journal of orthodontics
    • /
    • v.41 no.6
    • /
    • pp.447-453
    • /
    • 2011
  • Objective: We compared the shear bond strength (SBS) of lingual retainers bonded to bovine enamel with three different resins using direct and indirect methods. Methods: Both ends of pre-fabricated twisted ligature wires were bonded to bovine enamel surfaces using Light-Core, Tetric N-Flow, or Transbond XT. Phosphoric acid-etched enamel surfaces were primed with One-Step prior to bonding with Light-Core or Tetric N-Flow. Transbond XT primer was used prior to bonding with Transbond XT. After 24 hours in water at $37^{\circ}C$, we performed SBS tests on the samples. We also assigned adhesive remnant index (ARI) scores after debonding and predicted the clinical performance of materials and bonding techniques from Weibull analyses. Results: Direct bonding produced significantly higher SBS values than indirect bonding for all materials. The SBS for Light-Core was significantly higher than that for Tetric N-Flow, and there was no significant difference between the direct bonding SBS of Transbond XT and that of Light-Core. Weibull analysis indicated Light-Core performed better than other indirectly bonded resins. Conclusions: When the SBS of a wire retainer is of primary concern, direct bonding methods are superior to indirect bonding methods. Light-Core may perform better than Transbond XT or Tetric N-Flow when bonded indirectly.

The discrete element method simulation and experimental study of determining the mode I stress-intensity factor

  • Shemirani, Alireza Bagher;Haeri, Hadi;Sarfarazi, Vahab;Akbarpour, Abbas;Babanouri, Nima
    • Structural Engineering and Mechanics
    • /
    • v.66 no.3
    • /
    • pp.379-386
    • /
    • 2018
  • The present study addresses the direct and indirect methods of determining the mode-I fracture toughness of concrete using experimental tests and particle flow code. The direct method used is compaction tensile test and the indirect methods are notched Brazilian disc test, semi-circular bend specimen test, and hollow center cracked disc. The experiments were carried out to determine which indirect method yields the fracture toughness closer to the one obtained by the direct method. In the numerical analysis, the PFC model was first calibrated with respect to the data obtained from the Brazilian laboratory test. The crack paths observed in the simulated tests were in reasonable accordance with experimental results. The discrete element simulations demonstrated that the macro fractures in the models are caused by microscopic tensile breakages on large numbers of bonded particles. The mode-I fracture toughness in the direct tensile test was smaller than the indirect testing results. The fracture toughness obtained from the SCB test was closer to the direct test results. Hence, the semi-circular bend test is recommended as a proper experiment for determination of mode-I fracture toughness of concrete in the absence of direct tests.