• Title/Summary/Keyword: Dips

Search Result 153, Processing Time 0.027 seconds

A Case Study on Stability Evaluation of Road Slope based on Geological Condition (지질조건에 따른 도로사면 안정검토에 대한 사례연구)

  • Park, Chal-Sook;Kim, Jae-Hong
    • The Journal of Engineering Geology
    • /
    • v.17 no.4
    • /
    • pp.577-587
    • /
    • 2007
  • The length of study area was about 450m, and it was shown the geological condition of distinguished change of rock by cutting slope. In order to establish a slope stability, we carried out an engineering geological investigations about rock constituent, rock structure and a direction of discontinuous plane. The study area was divided into six section considered by direction of cutting slope, height of slope and geological condition. Analysis of cutting slope stability was carried out with stereo-graphic projection method by DIPS program which was feasible of stability analysis with geometrical correlation for a direction of discontinuous plane and direction of cutting slope. From analysis of cutting slope stability considered by construction, stability and economical efficiency, the slope stability countermeasures such as a high tensile wire net, slope protection method and enhanced retaining wall were established and operated which minimized effect caused by lower end of road on a relaxation of huge rock.

A Robust PLL of PCS for Fuel Cell System under Unbalanced Grid Voltages (불평형 계통전압에 강인한 연료전지용 전력변환시스템의 PLL 방법)

  • Kim, Yun-Hyun;Kim, Wang-Rae;Lim, Chang-Jin;Kim, Kwang-Seob;Kwon, Byung-Ki;Choi, Chang-Ho
    • Proceedings of the KIPE Conference
    • /
    • 2008.06a
    • /
    • pp.103-105
    • /
    • 2008
  • In grid-interconnection system, a fast, robust and precise phase angle detector is most important to grid synchronization and the active power control. The phase angle can be easily estimated by synchronous dq PLL system. On the other hand under unbalanced voltage condition, synchronous dq PLL system has problem that harmonics occur to phase angle or magnitude of grid voltage because of the effect of the negative sequence components. So, To eliminate the negative sequence components, the PLL method using APF (All Pass Filter) in a stationery reference frame to extract positive sequence components under unbalanced voltage condition is researched. In this paper, we propose a new PLL method with decoupling network using APF in a synchronous reference frame to extract the positive sequence components of the grid voltage under unbalanced grid. The cut-off frequency of APF in a synchronous reference frame can be set to twice of the fundamental frequency comparing with that of APF in a stationery reference frame which is the fundamental frequency. The proposed PLL strategy can detect the phase angle quickly and accurately under unbalanced gird voltages. Simulation and experimental results are presented to verify the proposed strategy under different kind of voltage dips.

  • PDF

Analysis on Momentary Voltage Dips with the Interconnection Operation of Utility-interactive Cogneration Systems Considering Their Generator Type (발전기 형태를 고려한 열병합발전시스템의 배전계통 연계운전시의 순시전압변동 해석)

  • 최준호;김재철
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.14 no.4
    • /
    • pp.23-30
    • /
    • 2000
  • Cogeneration systems are seen as a significant innovation for dispersed energy generation since they are both environmentally friendly and has comparatively high degrees of efficiency. It is especially suited for the decentralized provision of electricity and heat. However, it causes operational problems such as voltage regulation, voltage variation, protection and safety. Especially, it is expected that the interconnection/disconnection operation of cogeneration system has an effect on distribution voltage regulation and variation. Recently, with the increased use of customer-owned computers and other sensitive electronic equipment, electric power quality has become an important concerns. Therefore, the voltage quality problems with cogeneration system should be investigated because the voltage quality is an important part of electrical power quality. In this paper, the momentary voltage dips associated with the interconnection/disconnection operation of cogeneration system are analyzed, including restraint solutions at the customer level. In addition, the unit capacity of cogeneration systems per feeder are evaluated from the view point of momentary voltage variations. The results of this paper are useful analysis data for interconnection standards/guidelines of cogeneration systems and dispersed generation (DG)

  • PDF

Failure Characteristics of Cut Slopes in Sedimentary Rock of Kyongsang Basin (경상분지 퇴적암 절취사면의 붕괴특성)

  • 유병옥;황영철;정형식
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 1999.03a
    • /
    • pp.339-346
    • /
    • 1999
  • The stability of rock slope is considered to have a deep relation with types of rocks because types of rocks have their own typical weathering profiles, geological structures and characteristics of failures. Therefore it is essential for the evaluation of rock slope stability to analyze geological and engineering characteristics in rock mass. The data which collected from investigated slopes in sedimentary rock of Kyengsang Basin along highways were analyzed. Primary factors affecting slope stability in rock mass are: dips and strikes of slopes and discontinuities, shear strength of discontinuities, slope geometry and geological structures etc.

  • PDF

Response Time Optimization of DVR for 3-Phase Phase-Controlled Rectifier (3상 위상제어 정류기를 위한 DVR의 반응시간 최적화)

  • Park, Chul-Woo;Joung, Sookyoung;Ryu, Jee-Youl;Lee, Dae-Seup
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.19 no.3
    • /
    • pp.195-201
    • /
    • 2013
  • In this paper, we present optimization technique for the response time of DVR (Dynamic Voltage Restorer) and the possible compensation range of voltage dip by the DVR system. To protect 3-phase phase-controlled rectifier from voltage dip, DVR system needs to have optimum response time as an important design factor. Although the fast response time of DVR ensures wider range of voltage dip, DVR controller has so high cost and poor stability. This paper proposes DVR system with optimum response time required for certain intensity of voltage dips and good stability to support possible compensation range of voltage dip. Proposed technique showed optimum response time and good stability for overall system. We believe that proposed technique is reliable and useful in DVR design.

Correction of Coordinate Discontinuities Caused by GPS Antenna Replacements

  • Kim, Dusik;Park, Kwan-Dong;Won, Jihye
    • Journal of Positioning, Navigation, and Timing
    • /
    • v.4 no.3
    • /
    • pp.131-140
    • /
    • 2015
  • Antennas at permanent GPS stations operated by the former Ministry of Government Administration and Home Affairs (MOGAHA) in Korea were replaced in years 2008 and 2009, and these changes caused abrupt discontinuities in precise coordinate time series. In this study, an algorithm that eliminates those breaks was developed based on 15-year-long coordinate time series for the purpose of creating clean and continuous coordinate time series. The newly developed algorithm to correct for sudden jumps and dips in the GPS time series due to the antenna change was designed to consider all the linear and annual signals observed before and after the event. The accuracy of the new algorithm was confirmed to be at the Root Mean Square Error (RMSE) level of 2.3-2.6 mm. The new algorithm was also found to be capable of reflect site-specific characteristics at each station.

EDFA Gain Stabilization via Disturbance Observer Techniques

  • Im, Yoon-Tae;Seo, Kwang-Bok;Song, Seong-Ho
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2003.10a
    • /
    • pp.2143-2146
    • /
    • 2003
  • We propose, for the first time to our knowledge, a novel gain-clamping method for EDFA in WDM Add/Drop networks by introducing a disturbance observer technique. The proposed gain-clamping control input consists of the nominal gain-clamping control such as PI(Proportional and Integral) control and the additional control input for the compensation of the effects caused by channel add/drops. The additional control input is designed using the wellknown disturbance observer technique and can be implemented very easily with general electric elements. We proved the superiority of the new technique over the previous methods by showing simulation result of minimized dips and spikes that appear in power profile of EDFA output.

  • PDF

Geology and Ore Deposit of Pocheon Iron Mine (포천광산(抱川鑛山)의 지질광상(地質鑛床))

  • Kanda, Yomoo
    • Economic and Environmental Geology
    • /
    • v.2 no.2
    • /
    • pp.53-67
    • /
    • 1969
  • Magnetite deposit of Pocheon Iron Mine is a contact replacement skarn deposit embedded in the carbonate rocks (limestone and dolomite) which are intruded by granite porphyry. The shape of ore bodies is sweet potato-like and/or irregular massive form; D-ore body, the biggest one is of $180m{\times}40m{\times}200m$ in size. The ore is in general of high grade. The location of the ore bodies is controlled by the fault which strikes north south and dips $60^{\circ}$ to $70^{\circ}$ to the west. A regular distribution of mineralized zones is recognized in order of outward (hanging wall side) from granite porphyry as follows: compact fine-grained skarn, limesilicates, magnetite ore body, marble, limesilicates, pyritized meta-sediments.

  • PDF

Current-Controlled Wavelength-Tunable Fiber Comb Filter based on Polarization-Diversity Loop Configuration (전류 조절로 파장 튜닝 가능한 편광상이 배치구조 기반 광섬유 빗살 필터)

  • Choi, Dae-Ho;Lee, Yong-Wook
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.24 no.12
    • /
    • pp.33-37
    • /
    • 2010
  • In this paper, we have demonstrated absolute wavelength tuning in an optical fiber comb filter based on a polarization-diversity loop configuration by controlling the current injected into enameled wires wound on polarization-maintaining fibers (PMF's), that is, adjusting Joule heat generated from enameled wires. The proposed fiber comb filter consists of a polarization beam splitter, a half-wave plate, a quarter-wave plate, and PMF's. And we observed wavelength change of spectral dips in transmission spectra of the fabricated filter by varying an input current applied to enameled wires. The absolute wavelength of the filter could be controlled in proportional to the square of the input current with good linearity, and the rate of the wavelength shift with respect to the input current was measured as 36.79[nm/$A^2$].

A Design for Dynamic Line Rating System to increase Overhead Transmission Line Capacities (가공송전선의 송전용량을 증가시키기 위한 동적송전용량 시스템의 설계)

  • Kim, Sung-Duck
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.25 no.7
    • /
    • pp.72-77
    • /
    • 2011
  • Dynamic Line Rating (DLR) techniques have been greatly worthy of notice for efficiently increasing transmission capacity as well as controlling load-flow in overhead transmission lines, in comparison with the existing power system operating with Static Line Rating (SLR). This paper describes an utilization method to implement DLR control system for old transmission lines built in the first stage using the ground clearance design standard with lower dips. The suggested DLR system is focused on designing as temperature control system rather than current/load control system. Based on several performance for conductor temperatures, it is shown that DLR system with efficiency can be implemented.