• Title/Summary/Keyword: Dipole-dipole Array

Search Result 163, Processing Time 0.03 seconds

Application of geophysical exploration for gold in the YongJang mine, Masan (마산 용장광산에서 금광에 대한 물리탐사의 적용)

  • Park, Jong-Oh;Song, Moo-Young;Park, Chung-Hwa;You, Young-June
    • 한국지구물리탐사학회:학술대회논문집
    • /
    • 2006.06a
    • /
    • pp.213-219
    • /
    • 2006
  • The Yongjang mine is located in Masan City, Gyeongsangnamdo, which consists of a black shale possessing quartzite veins with othercompositions such as gold, silver, and sublimated sulfur. The average width of the veins is $9{\sim}17cm$ and the average degrees of the gold and silver are 3.6 g/t and 113.6 g/t respectively. A regional and a detailed scale electrical resistivity surveys are conducted to determine the existence of the mineralization zones and the linear structures in the study area. In addition, surveys of a several different array methods are conducted such as dipole-dipole array in the surface and borehole-to-surface array, surface-to-borehole array, and dipole-dipole array in the borehole. The method of element division can be applied to the region in which the borehole is curved, inclined or the distance between the electrodes is shorter than that of nodal points, because the coordinate of each electrode cannot be assigned directly to the nodal point if several electrodes are in an element. Yongjang vein is extended longer under the subsurface than on the surface in the images reconstructed from the 3D inversion. Therefore, it is recognized that the 3-D interpretation of the electrical resistivity survey is a very useful method to figure out the existence of strike and extension direction because the mineralization zones and the linear structures are shown in each depth.

  • PDF

Detection of Sea-water Intrusion Caused by Tidal Action Using DC Resistivity Monitoring (전기비저항 모니터링을 이용한 해수침투 파악)

  • Hwang, Hak-Soo;Lee, Sang-Kyu;Ko, Dong-Chan;Kim, Yang-Soo;Park, In-Hwa
    • Geophysics and Geophysical Exploration
    • /
    • v.3 no.1
    • /
    • pp.1-6
    • /
    • 2000
  • The 1 $km^2$ area studied is located in Sukchun-ri, Hwasung-koon, the southern part of Kyeonggi-do. Even though this site has been known as a contaminated area caused by seawater intrusions, geophysical and geochemical surveys have never been carried out at the site to determine the extent of the seawater contamination and to investigate whether the seawater intrusion is in progress. The purpose of this study is to determine the extent of seawater contamination and a preferred channel of the seawater intrusion using geophysical methods such as DC resistivity surveys with Schlumberger array and a dipole-dipole array. In order to determine whether the seawater intrusion is in progress in the area, DC resistivity monitoring with Schlumberger array was performed. According to the resistivity map obtained from the inversion of the resistivity data measured with Schlumberger array, the study area is divided into two districts as relatively lowly resistive (less than 30 ohm-m) and highly resistive (more than 30 ohm-m) areas. The distribution of the lowly resistive area is consistent with the distribution of the layer composed of clay minerals, and the resistivity of this layer decreases slowly as approaching to the old seashore. Hydrogeological analysis shows that the clay layer within a distance of about 200 m from the seashore has been already contaminated by sea-water and its electric conductivity is 8 times higher than that of the sand layer covered by the clay layer. According to the results of the 2-dimensional DC resistivity surveys with a dipole-dipole array, there are two preferred channels of the seawater intrusion in the site, and both the channels are in the NW-SE direction from the old seashore. The lowly resistive zone in the southern channel extends to a depth of 80 m. The DC resistivity monitoring with Schlumberger array was carried out along the preferred channel which has the low resistivity Bone (fracture zone) that extended to a depth of 80 m. The time series of apparent resistivity, measured at a distance of 260 m from the old coast line, fluctuates with a period of 12 hours. From these observations, it can be concluded that the seawater intrusion caused by tidal action is still in progress along the fractured zone interpreted by the DC resistivity surveys with a dipole-dipole array.

  • PDF

A Study on Radiator of VHF-Band Active Electronically Scanned Array with the Trapezoidal Dipole Structure Using Meander-Line (미엔더 라인을 이용한 사다리꼴 다이폴 구조의 VHF 대역 능동 위상 배열안테나 복사소자 연구)

  • Park, Dae-Sung;Ko, Young-Kwan;Choi, Jae-Hoon
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.27 no.12
    • /
    • pp.1027-1035
    • /
    • 2016
  • In this paper, the method to miniaturize the radiating element of a VHF-band active electronically scanned array is proposed. The length of the proposed dipole having trapezoidal shape structure is miniaturized using meander line while the performance degradation is minimized. The grid reflector is used to improve the antenna directivity and insensitivity due to the outer environment. In addition, the antenna is designed to take into account for array application. The fabricated antenna has a 9.1 % fractional bandwidth for the voltage standing wave ratio(VSWR) 2:1 and the maximum gain of 4.24 dBi. The front-to-back ratio(FBR) is larger than 15 dB.

Resistivity Survey on Stylobate of Five-story Stone Pagoda in Tamni-ri, Uiseong (의성 탑리리 오층석탑 기단부 전기비저항 탐사)

  • Oh, Hyundok;Kwon, Moonhee
    • Geophysics and Geophysical Exploration
    • /
    • v.23 no.4
    • /
    • pp.253-260
    • /
    • 2020
  • The five-story stone pagoda in Tamni-ri located in Uiseong County in Gyeongsangbuk-do had an unstable upper structure, and the structural deformation of the foundation stone and the stylobate was severe. In order to repair the base of the pagoda, it must be confirmed if there are support stones inside the base. Resistivity survey was performed to study the inner base stone structure during the repair work. The stylobate was exposed soil and broken stones after removing the walls and the cover of the stylobate. Modified pole-dipole array II was used for the resistivity survey, and compared with the typical pole-dipole array method. And in this study, a physical scale-down model experiment was performed to compare and analyze distortions caused by severe topographical undulations such as right-angled lines. The results show that the stylobate of Five-story Stone Pagoda in Tamni-ri Uiseong has base stones inside the reinforced filling soil and are located beneath the pillar of the body and supporting the pagoda.

A Study on Miniaturization of a Log-Periodic Dipole Array Antenna (대수주기 다이폴 배열 안테나의 소형화 연구)

  • Ham, Hyung-Jun;Ryu, Hong-Kyun;Park, Beom-Jun;Park, Young-Ju;Lee, Kyu-Song;Woo, Jong-Myoung
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.25 no.7
    • /
    • pp.709-720
    • /
    • 2014
  • In this paper, we studied miniaturization of LPDA(Log-Periodic Dipole Array) antenna used for VHF and UHF bands. To miniaturize the LPDA antenna, in this study, the radiation elements in a low frequency were changed into a triangular meander structure which has small current cancelation effect at feed part. For the triangular meander structure, an isosceles triangular and right triangular meander structures were proposed and the LPDA antennas were miniaturized by using the two meander structures. Also, the simulated and measured results were compared for the two miniaturized LPDA antennas. As a result, the isosceles triangular meander and right angle triangular meander structure applied LPDA antennas were reduced up to 60.5 % and 72.4 % compared a basic LPDA antenna, respectively. Consequently, we confirmed that the triangular meander structure is suitable for miniaturization of a LPDA antenna.

Investigations of Faults using array CSAMT Method (단층조사를 위한 array CSAMT 적용사례)

  • Lee Sang Kyu;Hwang Se Ho;Lee Dong Young;Lee Jin-Soo;Hwang Hak Soo;Park In Hwa
    • Geophysics and Geophysical Exploration
    • /
    • v.1 no.2
    • /
    • pp.92-100
    • /
    • 1998
  • Array CSAMT surveys were conducted in two areas where it was not easy to identify the presence of faults only with geological survey because of thick overburden. The purpose of these surveys were to locate the faults and to delineate the deep resistivity structures around the faults. The steep dip lineaments having high contrast in resistivity laterally and the low resistive zones having some width in the resistivity sections were interpreted as faults and fracture zones associated with faults, respectively, The good applicability of array CSAMT to the investigation of fault was recognized owing to the agreement between the interpretation results of array CSAMT and the conclusive evidences collected by the following geological survey. The evidences includes the recent exposure of fault and the trajectory of fault evidences of the survey line. A comparison of the applicabilities of array CSAMT method and the resistivity method using dipole-dipole array was presented with the results of both methods along a same traverse line.

  • PDF

Design for Linearly Polarized Microstrip Antenna using Electromagnetic-Coupled Dipoles (전자기결합 다이폴을 이용한 직선편파 마이크로스트립 안테나의 설계)

  • 민경식;장철순
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.12 no.7
    • /
    • pp.1057-1066
    • /
    • 2001
  • This paper describes a design for linear polarization antenna using the EMCD (electromagnetically coupled dipole). The analysis and the design of model antennas are conducted by FDTD method. Vertical and horizontal linear polarizations are easily obtained by variation of dipole position. In 1-element antenna design, mutual coupling between microstrip feed line and radiator is considered. Design parameters of each 1-element antenna with vertical and horizontal polarization are used for array design. Radiation power and main beam tilting angle can be controlled by the offset and the distance between radiating elements in an array, respectively. 5-element array antennas are fabricated and measured to prove the design validity. The results of FDTD simulation and measurement show the reasonable agreement.

  • PDF

Design of L-Band Cylindrical Active Phase Array Antenna Using Bent Dipoles (접힌 다이폴 구조를 적용한 L-Band 원통형 능동 위상배열 안테나 설계)

  • Lee, Man-Gyu;Kwon, Ickjin
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.50 no.6
    • /
    • pp.43-55
    • /
    • 2013
  • In this paper, we propose a cylindrical active phased array antenna of Beam Steering Characteristics in the horizontal plane(H-plane) and vertical plane(E-Plane) on the cylinder form array structure. We design the bent dipole antenna of the cylindrical array structure adapted excellent mutual-coupling characteristics, designed and manufactured the cylindrical array antennas and power combiner/divider unit for power dividing and combining on the antenna. The radiating elements array spacing of Cylindrical array antenna were determined to avoid grating lobes at half power beam steering. Beam steering of the antenna was implemented with 6-bit phase shifter in the transceiver and have been designed based on the characteristics the antenna beam steering at -24 degrees to 24 degrees horizontal, vertical 0 degrees to 36 degrees beam steering. A cylindrical active phased array antenna that produced for verification the performance of the antenna are measured radiation characteristics in accordance with beam steering at L-Band.

Characteristics of Distribution and Potential Route of Contaminants at Waste Disposal Site (폐기물매립지 주변의 오염물질 분포 및 이동 특성)

  • 박성원;황세호;이평구;박인화;신성천;이상규
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2001.04a
    • /
    • pp.144-148
    • /
    • 2001
  • A geophysical and geochemical study was performed to verify the depth of landfill as well as the horizontal/vertical distribution of leachate at the landfill site located in Gongju. The electrical resistivity, with dipole-dipole array and dipole spacing of 5m, was applied along the nine survey lines and electromagnetic induction survey was conducted along the perimeter traverse surrounding the landfill. Cations, anions and stable isotope ($\delta$D and $\delta$$^{18}$ O) analyses were performed on about 63 water and leachate samples collected in dry and rainy seasons at 31 sites. The result of electromagnetic induction survey make it possible to derive the potential route of leachate in the past or present. The imaging of processed resistivity field data show that the possible route of leachate doesn't exist except the survey line 7. The weak zone traversing the landfill, however, is revealed by the electrical resistivity imaging, which may be the potential route of leachate toward the deep ground. The geochemical data agree well with geophysical data for deducing possible route of leachate of the site.

  • PDF